Duxe POWER GOMPANY P.O. Box 33180 CIIARLOTTE. N.O. 28242 HAI. II. TI1CKER TELEPHONE vion enemment (704) 373-4531 wuotmAn reuputmon August 21, 1987 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. C. 20555
Subject:
Catawba Nuclear Station Docket Nos. 50-413 and 50-414 McGuire Nuclear Station Docket Nos. 50-369 and 50-370 Generic Letter 83-28, Item 4.2.2
Dear Sir:
In response to your letter of July 23, 1987, we wish to state our intention to implement a trendi'g program per your requirement for reactor trip breaker n
parameters at McGuire and Catawba Stations.
This program will consist of an annual trending analysis of data recorded during regular periodic maintenance for trip force, undervoltage trip attachment dropout voltage and breaker response time. An evaluation will be performed by Duke
}
Power's Design Engineering Electrical Division personnel, who will look for possible trends which might predict degradation of the breaker.
At McGuire, we are in the midst of replacing the reactor trip breakers.
For each new breaker installed, we will initiate the program at the first maintenance interval. At Catawba, we will initiate the program at the next maintenance interval.
Very truly yours,
/4 1/wL -
Hal B. Tucker LTP/84/sbn Attachment xc:
Mr. P. K. Van Doorn Mr. W. T. Orders NRC Resident Inspector NRC Resident Inspector Catawba Nuclear Station McGuire Nuclear Station Dr. J. Nelson Grace, Regional Administrator U. S. Nuclear Regulatory Commission I
Region II 101 Marietta Street, NW, Suite 2900 g
Atlanta, Georgia 30323 0