Monthly Operating Rept for June 1987
ML20237K810
Person / Time
Site: Maine Yankee
Issue date: 06/30/1987
From: Taylor J, Whittier G
Maine Yankee
To:
NRC
References
GDW-87-162, MN-87-82, NUDOCS 8708190413
Download: ML20237K810 (7)


Text

- _ _ - _ _ _ _ - _ - _ _

OPERATING DATA REPORT Docket No.:

50-309 Data 07/Jul/87 Completed By:

J.M.

TAYLOR Telephone:

207-892-6321 1.

Unit Name.......................................

Maine Yankee 2.

R: porting Period................................

June 1987

3. Licensed Thermal Power (MWt)....................

2630 4.

Ntmeplate Rating (Gross MWe)....................

864 5.

Dasign Electrical Rating (Net MWe)..............

825 l

l l

6. M ximum Dependable Capacity (Gross MWe).........

850 l

7.

Mmximum Dependable Capacity (Net MWe)...........

810 O.

If Changes in Capacity Ratings (Items Number 3-7)

Since Last Report, Give Reasons:

NO CHANGES l

9.

Power Level to Which Restricted, if Any (Net MWe)

10. Recsons f or Restrictions, if Any:

THIS MONTH YEAR-TO-DATE dUMULATIVE

11. Hours In Reporting Period 720.00 4.343.00
12. Number of Hours Reactor Was Critical...........

336.10 2.400.53 102.529.42

13. Reactor Reserve Shutdown Hours..................

0.00 0.00 0.00

14. Hours Generator On-line..

214.11 2.277.56 99.617.25

15. Unit Reserve Shutdown Hours..................

0.00 0.00 0.00

16. Grous Thermal Energy Generated (MWH)........

252.562.00 5.084.803.00 226.342.115.00

17. Gross Electrical Energy Generated (MWH)........

73.290.00 1.651.180.00 74.352.190.00

18. Net Electrical Energy Generated (MWH)........

67.568.00 1.589.549.00_

71.017.620.00

19. Unit Service Factor......

29.74 52.44 77.62

20. Unit Availability Factor..

29.74 52.44 78.35

21. Unit Capacity Factor (Using MDC Net)........

11.59 45.19 69.99

22. Unit Capacity Facto-(Using DER Net)........

11.38 44.36 68.18

23. Unit Forced Outage Rate..

26.63 3.30 6.42

24. Shutdowns Scheduled Over Next 6 Months:

NONE

25. If Shutdown at End of Report Period, Estimated Date of Startup:

N/A R

\\

\\

f..

Docket.No:

50-309 Unit Names Maine Yankee Date:

01/Jul/87 Completed By: J.~ M. Taylor Telephone:

207-882-6321-I i

. Report Month: June, 1987-i i

NARRATIVE

SUMMARY

OF OPERATING EXPERIENCES 3

At the beginning of the month the plant was in a refueling outage.

On June 9 and 10 low power physics testing was conducted.

On June 18 the unit was phased to the grid but later removed for turbine testing.

-On' June 19 the unit was phased to the grid.

i On June 22 power was reduced to-37% due to main turbine vibration.

j On-June 23 the unit was taken of fline f or adjustments to reduce H

main turbine vibration.

On June 25 the unit was phased to the grid. Power was held at 19%

i L

due to main turbine vibration.

(;

On June 26 power was increased to 33% but the unit was later E

taken:offline for adjustments to reduce main turbine vibration.

On June 26 the unit was phased to the grid.

j On June 27 power was held at 48% for repairs to the #3 mainfeedwater regul ating valve controller. During repairs an increase in steam l

generator water level occured and the unit was manually tripped.

L On June 28 the unit was phased to the grid. Power was held at 61%

due to main turbine vibration.

On June 29 loading continued to 66%.

On June 30 power was reduced to 34% to evaluate main turbine vibration.

At the end of the month power was 34%.

l l

l l

l b

AVERAGE. DAILY UNIT POWER LEVEL FOR JUNE 1987 Docket No.:

50-309 Unit:

Maine Yankee l

Date:

04/Jul/87 l

l Completed By:

J.M.

TAYLOR I

Telephone:

207-882-6321 i

Day Avg. Daily Power Level Day Avg. Daily Power Level (MWe-Net)

(MWe-Net) 1 O

16 O

2 0

17 O

3 0

18 18 4

0 19 124 5

0 20 293 6

0 21 363 7

0 22 457 8

0 23 108

)

9 0

24 0

10 0

25 8

11 0

26 102 j

i 12 O

27 187 l

13 0

28 344 14 0

29 481 15 0

c.0 i

cu I,

P

)

i i

i "I

e 5

I

'h

/ UNIT SHUTDOWNS AND POWER REDUCTIONS' Docket No.:

50-309 FOR JUNE 1987 Unit:

Maine Yankee Date:

07/Jul/87 Completed By:

J.M.

TAYLOR Telephene:

207-882-6321 Page:

1 of 3 Number 16-87-9 17-87-10 load reduction Date 870327 870618 870622 Type (1)

S S

F i

DLirati cn (Hours) 417.3 10.9 21.8 Reason (2)

C B

B Method (3) 1 1

1 LER #

N/A N/A N/A System Code (4)

ZZ HA HA Component Code -(5)

N/-A turbin turbin plant shutdown main turbine main turbine for refueling testing vibration outage i

Cause and Corrective Action 1.

TYPE:

2.

REASON: (cont) 4.

SYSTEM CODE:

(F)orced F-Administrative Exhibit G-Instructions (S)cheduled G-Operational Error for Preparation of Data H-Other (Explain)

Entry Sheets for 2.

REASON Licensee Event Report A-Equipment Failure 3.

METHOD:

(LER) File (NUREG.0161)

B-Maintenance or Test 1-Manual C-Refueling 2-Manual Scram 5.

COMPONENT CODE:

D-Regulatory Restriction 3-Automatic Scram Exhibit I-Same source E-Operator Training 24 4-Other (Explain) as above.

License Examination

UNIT SHUTDOWNS AND POWER REDUCTIONS Docket No.:

50-309 FOR JUNE 1987 Unit Maine Yankee Date:

07/Jul/87 Completed By:

J.M.

TAYLOR Telephone:

207-882-6321 Page:

2 of 3 Number 18-87-10 19-87-10 20-87-10 Date 870623 870626 870627 Typa (1)

F F

F Duration (Hours) 59 7.4 11.3 Reason (2)

B B

B Msthod (3) 1 1

2 LER #

N/A N/A 87-007 System Code (4)

HA HA HB Component Code (5) turbin turbin HTEXCH main turbine main turbine manual trip due vibration, vibration, to high steam balanced turbine balanced turbine generator water level Cause and Corrective Action 1.

TYPE:

2.

REASON: (cont) 4.

SYSTEM CODE:

(F)orced F-Administrative Exhibit G-Instructions (S)cheduled G-Operational Error for Preparation of Data H-Other (Explain)

Entry Sheets for 2.

REASON Licensee Event Report j

A-Equipment Failure 3.

METHOD:

(LER) File (NUREG.0161) l B-Maintenance or Test 1-Manual I

C-Refueling 2-Manual Scram 5.

COMPONENT CODE:

D-Regulatory Restriction 3-Automatic Scram Exhibit I-Same source E-Operator Training &

4-Other (Explain) as above.

l License Examination

],

FOR JUNE 1987 Unit Maine Yankee Date:

07/Jul/87 Ccmpleted By:

J.M.

TAYLOR Telephone:

207-882-6321 Page:

3 of 3 Number load redaction Date 870630 Type (1)

F Durption (Hours) 22.6 Reason (2)

B Method (3) 1 LER #

N/A System Code (4)

HA Component Code (5) turbin main turbine vibration Cause and Corrective Action 1.

TYPE:

2.

REASON: (cont) 4.

SYSTEM CODE:

(F)orced F-Administrative Exhibit G-Instructions (S)cheduled G-Op erati on al Error for Preparation of Data H-Other (Explain)

Entry Sheets for i

2.

REASON Licensee Event Repcrt A-Equipment Failure 3.

METHOD:

(LER) File (NUREG.0161)

B-Maintenance or Test 1-Manual C-Refueling 2-Manual Scram 5.

COMPONENT CODE:

D-Regulatory Restriction 3-Automatic Scram Exhibit I-Same source E-Operator Training &

4-Other (Explain) as above.

License Examination I

i l

l l

(If 3

MAIRE ShRHEE ATOMICPOWERCOMPARUe

,uaug,,Ja?n"gC2s h

(207) 623-3521 e

July 10, 1987 MN-87-82 GDH-87-162 Office of Resource Management United States Nuclear Regulatory Commission Washington, D. C.

20555 Attention:

Mr. Richard A. Hartfield, Chief Management Information Branch

References:

(a)

License No. DPR-36.(Docket No. 50-309)

(b) NUREG-0020, Licensed Operating Reactors Status Summary Report

Subject:

Maine Yankee Monthly Statistical Report Gentlemen:

Enclosed you will find the Monthly Statistical Report for the Maine Yankee Atomic Power Station for July, 1987.

Very truly yours, MAINE YANKEE ATOMIC POWER COMPANY MI G. D. Whittier, Manager Nuclear Engineering and Licensing G0H/bjp Enclosure cc: Mr. Victor Nerses Mr. William T. Russell Mr. Pat Sears Mr. Cornelius F. Holden

\\'

_ _ _ _ _ - _ - _ _ - _ _ _