ML20237K574

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for Mar 1987
ML20237K574
Person / Time
Site: Ginna 
Issue date: 03/31/1987
From: Kober R, Mcnamara A
ROCHESTER GAS & ELECTRIC CORP.
To:
NRC
References
NUDOCS 8708190316
Download: ML20237K574 (6)


Text

]

.y

.l.

OPERATlHG DATA REPORT

~

DOCKET NO.

50 244 DATE April 10, 1987 COMPLETED BY [MS MD-Andrew E. McNarNira TELEPHONE 315-524--444 6 I: Set. 4n1 OPERATING STATUS Ginna Station

1. Unit Name:

R.E. GINNA NUCLEAR POWER PLANT Notes The unit was mstored to

2. Reporting Period:

March, 1987 service on 3/10/87 after com--

1520 pletion of the AI&O which 3.1.icensed Thermal Power (MW:):

4gn lasted 31.92 days.

Full

_l

- 4. Nameplate Rating (Gross MWe):

47n reactor power was reached on I

5. Dess,gn Electracal Rating (Net MWe):

3/15/87.

6. Maximum Dependable Capacity (Gross MWe):

490 470 l

7. Maximum Dependable Capacity (Net MWe):

H. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reasons:

. 9. Power Level to Which Restricted, If Any (Net MWe):

10. Reasons For Restrictions, If Any:

This Month Yr. to-Date Cumulative 744 2,160 152,040.00

11. Ilours in Reporting Period
12. Number of Ilours Reactor Was Critical 533.00 1,414.50 117,418.47 0

0 1,687.55*

13. Reactor Reserve Shutdown flours 513 1.394 115.078.38
14. Ilours Generator On Line 0

0 8.5 *

15. Unit Reserve Shutdown llours 708,461 1,967,765 161,017,814
16. Gross Thermal Energy Generated (MWil)
17. Gross Electrical Energy Generated (MWil) 240,373 659,771 52,748,383,
18. Net Electrical Energy Generated (MWil) 228,048 626.273 50.039.856 68.95%

64.54%

75.69%

19. Unit Service Factor
20. Un:t Availability Factor 75.70%

68.95%

64.54%

65.22%

61.69%

71.54%

21. Unit Capacity Factor (Using MDC Net) 65.22%

61.69%

71.54%

22. Unit Capacity Factor (Using DER Net) 0%

0%

6.86%

23. Unit Forced Outage Rate
24. Shutdowns Scheduled Over Next 6 Months (Type, Date and Duration of Each):
25. If Shut Down At End Of Report Period, Estimated Date of Startup:
26. Units in Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY j

1 COMMERCIAL OPERATION ab j

'l

  • Cmmulative Total Ccamencing January 1,1975 ory...,

8708190316 B70331 PDR ADOCK 05000244 R

PDR

s

.. AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.

50-244 UNIT R.E. Ginna Nuclear Power Plant DATE ADril, 10, 1987 COMPLETED BY 8mJ u 2 % 41 e Andrew E. McNamara TELEPHONE 1 (315) 524-4446 Ext. 301 at Ginna

-MONTH-March, 1987 DAY AVERAGE DAILY POWER LEVEL DAY AVFRAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1.

17.

493 2.

18.

492 3.

19.

492 4.

20.

493 5.

21.

493 6.

22, 494 7.

23.

494 8.

24.

494 9.

25.

493 10.

89 26.

493 11.

131 27.

493 1

12.

204 28.

493 13.

340 29.

493 14.

437 30.

494 15, 473 31, 494 16.

494 i

INSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in the reporting month.

Compute to the nearest whole megawatt.

1 lI j

e TN

- A

,u*

h' LP R

E W

1 0

O G

O a3 n&

E W

P d

oI R

a A

U R

ma +x e

N A 7 ce E

e(

NE n

ih 8

L e e C 9 c

o vt s s

sl e

U 2 M6 i

r y

n a 1

n i c

t o

eF t

4 efa itDiR r

a N

4 a

e e

sod c) u

~

0 J E4 t

v c

o c

- S L

S A

1 w4 i

n on2 uf E

b t

r o 4

N c

e t o9 r

e oL t

4 r

2 IN l e7 a

eo r i

sn m

f (

0 G rdd i

r5 n

r t u dt1 no a

r Ii s r S

t c

n on ee3 t

9 t

o e

- a e p p

n5 i

Co E. A A1 G

i R nl r

r pf Ga e e 1

t 1

&ct u n. o ieS i

ph R R

eA n t

t e

teun iP b r ytn )1 ib E EW E

s v

r u

e r

o h

t OMTI N

e6 h

a r

O ri xr nv1 x

NA A o

E l

C P

D set Ef EE0 E

T ND at a i

P ET T

wfr 4

5 E

I K N E

au L

XU L

t d

E i7 P

M T

n8a M

u/

I O

0h C

e1t h/i T3w S

NO IT mju C

g!U m) 7 U

8 a n r

D 9

mc ia E

1 aSl r

p R

c c x H

Si E

t R

CR

,4d l l a(

W M

ej#

a ams E

A du u oe on nt h O

h a aut tM M A O P

e-l D

T M1 234 I

N 3

N e

O e

A M

st n nt n

N T

e e o i

r o

W R

c v p

iE e a

t O

O L

R n

D P

i T

E m

U R

ax H

E S

m

  • gcgO

)

e T

n s

)

I Is@

1 i

n in a

N e

1 ]o % 2 p

c a

l U

l x

ni p

E oL x

t C

s ic&

E

(

t e e

(

"e2,y B

uT r

ig r

rt n o

r si r) l ia o e ne r n b

ivEi 7

F e Rai a

q l:I c

r t l l n ngryT a a p 3

t r nx 7

a or t Ejf e nn os oE 6,

m t

i i(

el at t

pt el a n ar 1

ni n u ur r e i

ouif gemeh s q a e e pd pt

{F S

e MRROAOO aE RABCDEFGI l

2 7

e t

8 a

D 6

de 2

l dued s

ce a

rh s

o a

c 1

FS s

.o s

N 7

a 8

FS

.v u

1 e'

l

-s L.

NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE DOCKET NO.

50-244 UNIT R.E.

Ginna Nuclear Power Plant DATE Anril 10. 1987 COMPLETED BY W 2. W h A n d r e w E. M c N'a m a r a TELEPHONE 1 (315) 524-4446 EXT. 301 at Ginna MONTH March, 1987 The unit was returned to service on 3/10/87 after completion of

'the Annual Refueling and Maintenance overhaul that lasted 31.92 days.

The reactor power level was gradually increased, in stages, reaching full power on 3/15/87.

The reactor power remained at this level through the end of the report period.

l

s.

GINNA STATION

~

MAINTENANCE REPORT

SUMMARY

4 MARCH, 1987 During the month of March, routine maintenance and inspections were completed.

Major safety related work included:

a.

Clean Strainers on.1-A Aux. F.W.

Pump b.

' Test Charging Pump Relief Valve - 283 c.

Repair Turbine Drain Union on Stm. Dr. Aux. F.W. Pump Turbine

'd.

Fabricate Special Tools for Rad. Monitors l

l 1

l i

l l

l

/

,Jf ~ i, D

/

7-9; ;. 4,qg

,g ql? ' '

e '""" j<j 9,,7'~

^a. 4, a

y I

,L.i aa nla.

fwe}

_ jg; gL w <; 3

- ROCHESTER GAS AND ELECTRIC CORPORATION e 89 EAST AVENUE, ROCHESTER N.Y. 14649-0001 f40Gt'.M W MOElER isirenour vice eme.siorni a nta cone 7)t. 546 2700 nitcTmc rmonucTiou GINNA STATION April 10, 1987 Director, Office of Management Information and Program Analysis U.S. NUCLEAR REGTJLATORY COMMISSION Washington, DC 205SS

Subject:

Monthly Report for March, 1987 Operating Status Information R. E. Ginna Nuclear Power Plant Docket No. 50-244

Dear Sir:

1 Pursuant to our Technical Specification 6.9.1, attached i

herewith is the monthly operating status report for Ginna Station l

for the month of March, 1987.

Vr truly yours, I

  1. f Y

~

Roger W. Kober

~~

RWK/eeh Attachments cc:

Dr. Thomas E. Murley NRC (1) l 1

Y y

_ _ _ _ _ _ _ _ _ _ _ _ _