i g m to SEP 1W E. Davis 306-SS SGTB: RHO 71-9176 Westinghouse Hittman Nuclear Incorporation ATTN: Mr. Bryan A. Roy 1256 North Church Street Moorestown, NJ 08057 Gentlemen:

l This refers to your application dated July 31, 1987, as amended July 28, 1987, requesting an amendment for the Model No. HN 14-215H package.

In connection with our review, we need the information identified in the enclosure to this letter.

Please advise us within 30 days from the date of this letter when this information will be provided. Additional information requested by this letter should be submitted in the form of revised pages.

If you have any questions regarding this matter, we would be pleased to meet with you and your staff.

Sincerely, W W hy Charles E. MacDonald, Chief Transportation Branch Division of Safeguards and Transportation, NMSS

Enclosure:

As stated Distribution: w/ encl Docket File NRC PDR 7 l

Region (I)

'RH0degaarden(2) l CEWilliams HWLee CRChappell HMSS R/F SGTB R/F

.L M

OFC :5' gp

5GTB jlkp:5GT
5GTB 5GTB NAME:RH0degaarden:kd HWLee
CEWiliiams: CRC 5appell cDonald:

BATE bhkhbh bh k hbh bhh[hbh [ 1 hbh : k/

hbh 0FFICIAL REC 0FD COPY kD[0hCK0710917s 00 070901 C

PDR

o 1

Westinghouse Hittman Nuclear Incorporated Model No. HN 14-215H Package

)

Docket No. 71-9176 1

l SEP 1 MT Encl to ltr dtd:

7 DRAWING - STD-02-077, Sheets 1 and 2 of 2, Rev. 1.

1.

The drawing should specify, by appropriate weld symbol, the requirements for the longitudinal weld joints in the inner and outer shells of the packaging.

2.

The material (malleable iron) for the pipe plugs appears inconsistent with the requirements of 10 CFR 971.43(d). The plugs may rust in j

place resulting in damage to the packaging.

4 3.

Drawing note on material finish requirements does not seem to be associated with a particular drawing note number.

4.

Item 5 Detail - The 1/4" diameter hole in the ratchet binder handle (Item 36)doesnotseemtobecompatiblewithItem38(1/4"dia.

bolt).

5.

Item 3 Detail - location of vent line needs clarification (8 7/8" from corner?).

OPERATING PROCEDURES-SECTION 7.0 1.

The procedures should contain a statement regarding the need to make a determination that closure seal replacement is current with the seal replacement schedule.

2.

A check of the cavity drain line and vent line should be required to l

determine that the pipe plugs have been properly installed using an appropriate pipe thread sealant.

3.

Prior to release for shipment, a radiation survey should be performed including a determination of surface contamination to assure compliance with 10 CFR 99 71.47 and 71.87.

ACCEPTANCE TESTS, SECTION 8.1 The test for shielding integrity should specify the grid size.

MAINTENANCE PROGRAM, SECTION 8.2 The program should address the maintenance of painted surfaces such as identification markings and match marks used for cover orientation.

l