Summary of 870624 Meeting W/Eqe,Inc to Discuss Lll Seismic Design Audit of Plant.Viewgraphs Encl
ML20237K046
Person / Time
Site: Hatch  
Issue date: 08/18/1987
From: Tan C
Office of Nuclear Reactor Regulation
To: Crocker L
Office of Nuclear Reactor Regulation
References
NUDOCS 8708270029
Download: ML20237K046 (71)


Text

_ -.

cz-nt i

[ Distribution *w/o enclosure Central FileMLReiter

  • Local /NRC PDR CPTan
  • ESGB Rdg File
  • GBagchi
  • MEMORANDUM FOR:

L. Crocker, Project Manager Project Directorate II-3 Division of Reactor Projects I/II FROM:

C. P. Tan, Civil Engineer Structural and Geosciences Branch Division of Engineering and Systems Technology

SUBJECT:

SUMMARY

OF MEETINGS WITH DR. JAMES JOHNSON OF EQE CONSULTANT TO LLNL A meeting with Dr. James Johnson of EQE consultant to LLNL was held in Room P1114-8 on June 24, 1987 to discuss the status of the LLNL technical assistance project on Hatch Units 1 and 2 seismic design audit. Dr. Johnson described the status of-the project and presented the findings to date in his independent review of Hatch 1 and 2 seismic analysis and design.

The meeting was attended by myself, L. Reiter, Chief of the Geosciences Section and G.

Bagchi, Acting Chief of ESGB. A copy of the viewgraphs used in the presentation is enclosed.

4. f. Y C. P. Tan, Civil Engineer Qs2Joh29s p

- [

Structural and Geosciences Branch n0 Division of Engineering and Systems Technology

Enclosure:

As stated cc:

J. Richardson w/o enclosure B. Youngblood w/o enclosure CONTACT:

C. P. Tan, X29444 l

Y hb ESGB: DEST 4['T ESGB: EST ESGB: DEST CPTan:jch LR 1-r GBagchi 8//(/87 8/ g 87 8/tV/87

)..

s

}.

}

l i

REVIEW OF SEISMIC ANALYSIS AND DESIGN OF HATCH UNITS 1 AND 2:

STATUS REPORT Presented to US NRC Nuclear Reactor Regulation Presented by James J. Johnson June 24,1987

& 'se_,

i y

y O

/

L THIS PRESENTATION WILL DISCUSS THE FOLLOWING k

'r

  • BACKGROUND
  • REVIEW OF HATCH DESIGN 1-e HATCH STRUCTURES e SEISMIC ANALYSIS PROCEDURES e UNITS 1 AND 2
  • ORIGINAL AND REANALYSIS
  • HATCH SITE CHARACTERISTICS
  • INDEPENDENT SEISMIC ANALYSES e REACTOR BUILDING
  • CONTROL BUILDING l-e RESULTS AND CONCLUSIONS e NEXT STEPS

=;;~ 5

. :a=

t~-

(

i

[

I THE HATCH REVIEW ENCOMPASSES SEVERAL ISSUES f

e UNITS 1 AND 2 SEISMIC DESIGN CRITERIA e IN - STRUCTURE SPECTRA PEAK BROADENING

{

(

15% VS 10%)

e UTILITY REANALYSIS e UPGRADE MODELS e REMOVE EXCESS CONSERVATISM

  • GENERATE FLOOR RESPONSE SPECTRA e COMPARE WITH ORIGINAL DESIGN SPECTRA e EVALUATION e DVRC DAMP!NG FOR PIPING e UNIT 1 DESIGN GROUND RESPONSE SPECTRA

..i v.'AE.

/

)'

s.

g INFORMATION FOR THIS EVALUATION WAS PROVIDED AS FOLLOWS:

""3 1

l

  • INITIAL REQUEST SEPTEMBER 11,1986
  • SOIL PROFILE, FOUNDATION DATA
  • DAMPING -- PROCEDURES, VALUES
  • FLOOR RESPONSE SPECTRA COMPkRISON
  • DYNAMIC MODEL -- DG BLDG
  • SEISMIC ANALYSIS METHODS COMPARISON
  • NOVEMBER 13,1986
  • FOLLOW - UP REQUEST DECEMBER 15,1986
  • SOIL PROFILE
  • DYNAMIC MODELS -- RB UNIT 1, CONTROL

\\

BLDG, INTAKE STRUCTURE

  • ARTIFICIAL ACCELERATION TIME HISTORIES -- UNITS 1 AND 2
  • MARCH 4,1987 i

=qa

~~

R 0

G 0

0 0

0 8 0 8 1 0 0 g

4 4 F 4 1

1 4 9 c.

MV 2

2 2

4 8 2 8 y

0 0

0 0

D 5

5 5

5 6

frO 0

0 0

0 0

0 0

8 1 0

4 4

4 1

1 4

C V

a.

2 2

2 4 8 2

L s

5 5

5 5

i sy D

5 5

5 5

l n

a a n e

/

A R 0

0 0

0 0,

0 0

8 1 9

1 1

4 4

1 1

3 b V 2

2 4 8 2 8 y

1 5

5 5

5 D

5 5

5 5

g N

ir

/ s O

0 0

0 s IS 0

0 0 7 0

1 4

4 9 1 4 o S

U V 2

2 1

6 2 N Y

LANA 1

5 5

e e

2 ru D

d t N

e c X

X X

X A

r u a r 1

h t

s s S

T I

NU HC

~

T o

A c

G 2 H

i 1 2 1

t t

s ei t

t i d v i it i un o e n n n

M R U U U

L o.

y tu t

r s

u-la B

s 8

s s

s n

A g

n 6

ip

+

n 2

n f

o a

oi D

t ni d

t s

o a

)

A n

o t

n f 5

5 e

5 5

7 i

t u

(

7 7

il 0

2 2

o o 1

1 5

3 ta B F P

e i

l d

b a

a R

T f

f o

o e

% % 0 r

5 0 0 u

7 2 1 t

s c

d u

k i

r 1

2 c

B t

~

a s

t t

l g

it i

s o

l k

d e

n n

r U

U n

t B

a n

t B

B i

o G

n a

R R

M c

D I

~

2 0

1 A

\\

s R

N T

\\

C s

E

\\

- b 5

\\

\\

G P

\\

. C

. s I

\\

N S

\\

1

\\

\\

e P E

\\

t M

\\

S o A N D

)z O

H

(

P y

S c

E ne R

u J-q l

D

/

e

/ I r

N

/

5

/

U

/

/

/

O

//

0

/[/

0 R

1 G

/ 'i/

i/

H C

's /

TA

's /

H

's

's

's i 2 T T 0 N N I I 5 U U 8 6

d 9

C.

0 5

0 5

0 n H H 0 1

03 2

2 1

1 e C C 0 1

g T T -

e A A R X

L H H C 5*#me%uM j

i II

)

1lIll!l11ll1l1la TL P.

C PS F

F 0

1 2-ce 2

g s.

t n/~

i i t n

pf m

U N

a n d

D i n

N 7 s a

\\

5 n 3

o

\\

t i at t

\\

i a

\\(

a r n

g t

0 r e U

\\

1 s

t l T

e c e r

\\

t e c o

I f

o p c

\\

N S A

\\

a

)z r

H t

t3 c

(

e c

S y

p

\\

f q

i ne n

u g

r/

e s

i r

e l

/

F D

/l 1

\\

d 4

l

/

0

/

1 e

J /

i F

{

e

/

e

~

rF a a

/

M M f

s o

d d j

l 3 n

ee o

i i s

/

F F i

r e e a

e e p

r r m

F F o

C i 2

~

0 d

G.

0 0

0 D.

0

c. 1 ne t t 02 0

e 5

4 2

g i i CO mtc,r* O 4 e

n n 11 1

L U U X

58

/50/

7OV 2

TLPSR tl'\\

\\

[

r p

u

\\

v

\\

'\\

I

~I

\\'n

\\

\\

g N

N I t I E I #

'~-

I I I I

ll

/

t I

s ;

/

l

/

h

)?

/,

's, 6

C 8

F

/

T O

I N

H 01 T

A U

L O

E E T T S

A A P

D D A

H R R ET KR ATC AO uM E

UN E

P Q

g L S

.H 5

N To T O CGE 0

2 T

F I

NS 2 RT AC0 K UIN

.0.E E O C DOO 4 RI NLIPN0 SIT Y Y IDA B B UST2S E

HB NNAER RI D D OOBSG E E CR C NN R W O IPTN I

TT MS AGOI A

E P

AC S VIP P

I AIS E SSM E V HEE A LEEA R E kSMEDRD P

R

-j m

.N N

O.

gd

~

1 1

[

n u

\\'

\\

O N

1 1

\\

~

l

/ j 1

1 /

~

/

'y 68 %

3 T

7 7 N

H o

T

^

t A

U e

L O

E E T T S

A A P

D D A

H R R ET T

KR AC AO s-E UN E

c P

Q N

L S H 5

.TTO CGE9FRTI0

~

N S1 y@

ACO UIN 0.E E C

DOO O

NLIPN SIT Y Y 6

RI 4

UST1 SIDA B B E

HB NNAER RI D D

_ CR C I

NN R

W OOBSG E E O

TT I PTN AGOI A E M S P

AC S VIP P

AIS SSM E

VI E

HEE A LEEA R E RSMEDRD P R

m

  • N N

o

uJli T

.ve w

0 S

0 5

I

+

2 S

Y n

L g

i A

se N

D A

.n.

r o

f I

0 S

0 d

0 e

S 2

s U

T a

t N

a D

E t

D s

)

e N

T ce d

E s

t

/

0 n

S o 1

t 0

P f

5 nt x.

i E

(

1 oa kL y

r D

t dt e e i

N c

s n o

ae I

le BP E

V e

H e

e v

c T

a W

N 0

r 0

^

I a

0 e

1 D

h S

E R

E D

n I

o S

i t

N 0

a 0

d O

5 n

C u

o E

F f

R o

E e

W saB S

E 0

L I

0 0

F 0

0 5

0 1

O 3

0 7

1 1

R P

L I

O O b

=. E y S

O W

T

f THE DIFFERENCES IN CALCULATED RESPONSE FOR l

UNITS 1 AND 2 DUE TO GROUND MOTION DEFINITION AND ANALYSIS PROCEDURES LED TO THE NECESSITY OF ESTABLISHING A BASIS OF COMPARISON, AN ASSESSMENT OF CONSERVATISM, AND SENSITIVITY OF RESULTS.

  • REACTOR BUILDING
  • SURFACE - FOUNDED
  • EMBEDDED

>^

I

  • TWO SOIL PROFILES
  • UNITS 1 AND 2 GROUND MOTIONS
  • CONTROL BUILDING
  • SURFACE - FOUNDED
  • TWO SOIL PR~OFILES a UNITS 1 AND 2 GROUND MOTIONS

}

}

v,

. = = =

1 lllll m

m n

o d

i e

t d a d d X

X e n b u m

m o E F e

l i

for P

no t

i i

o et s

c a u

a d X

X X

X t

f n f

r u o

u o S

S S F E

S Y

LAKA I

SS TN EDN EPE DN I

n 2

o d

i D

e t M

$ a dd X

X m

)

b m e

1 S

s m c T

p E F I

f NU 00 H

4 m

C 2

T

(

AH ecap S

M 2

/

n 1

o i

m e t r

c a o

a d X

X X

X m

f f

i r

n u o M

U S F n

n n

n o

o o

o i

i i

i t

t t

t o

o o

o M

M M

M d

d d

d m

n n

u u

o o

o o

e r

r r

r r

G G

G G

u t

t 2

c 1

2 g

2 U U

d u U

ur t

e e

t

/

e e

8 1

S g

l it e

d o

n r

k l

a B

U tn t

B o

n G

I D

R C

1 llIl I,

1l l

l' ll1 f

I t

1

Q l

SEVERAL INITIAL RESPONSE COMPARISONS HAVE BEEN MADE' REACTOR BUILDING o CASE 1 SURFACE - FND VS. DESIGN eTWO SOIL PROFILES

~

  • UNIT 1 GROUND MOTION l

e CASE 2 EMBBDDED - FND VS. DESIGN eTWO SOIL PROFILES l

  • UNIT 1 GROUND MOTION
  • CASE 3 SURFACE - FND VS. DESIGN l

l eTWO SOIL PROFILES

~

e UNIT 2 GROUND MOTION

  • CASE 4 EMBEDDED - FND VS. DESIGN eTWO SOIL PROFILES j

eUNIT 2 GROUND MOTION i

9(3

l i

CONTROL BUILDING f

CASE 5 SURFACE - FND VS. DESIGN

}.

  • TWO SOIL PROFILES
  • UNIT 1 GROUND MOTION CASE 6 SURFACE - FND VS. DESIGN

)

l

  • TWO SOIL PROFILES l

eUNIT,2 GROUND MOTION l

2:' 3

~.2 J;

THE UTILITY'S DYNAMIC MODEL FOR THE UNIT 1 REACTOR BUILDING WAS USED IN THE ANALYSES

.ltG txD :

L l '* 0 "

  • I0lMT YWdbfLMMO &$

A Josur Mr.our Mass i

late (i).

I, D = Muuss Meuus h

b 'M45SLES$ bMNC, yam M (?,)

@ Cune.

k, g

q ::

.g S

mh Oa kY ca

(

h 8

E o

a o

em e

M' s) t 22 k1CdG' 5 9

O

'E A

@A E

Y, Lab-

</'

g g@

g O

)

a E

5 s._e $is)

$to) m m@

5 8

a

  • @I g

a amY) sk(If.,

m bd

)

m d

s e

(2) e

A,8 A rnir*

il g

j e

s s 4

~

0 E

g

,:o-g i

Am

x. i..,

4A n

. f.. @

t-o*

s' o*

A

~'@

nto* l l_

pc. \\ _

N ATHEM ATICAL NODEL _

=;

-,----.-,-.---._.-m.-.

l CASE 1 REACTOR BUILDING SURFACE FOUNDATION VS. DESIGN UNIT 1 GROUND MOTION i

l-

):

I 1

I

}/

1 i

i l

i,\\

l l!$

n.

1 B

R.

E DC T

LP 2

10 n

ao ri g

tt n2 cc i c ee p e pr ms Si a/

D D t n

f gW s,

S n sE E

i -

i e

g D

t 's a

)

~

n Ct

~

ao Pf ri G

\\

s t t 7

^g c a h8 e r t

N

0 p e i

N

s sl wv N'

1 e

e e

l

~

s t

l c s3 s.

o l c eE s'

N A

A_

sI y'.

)

s z

s H

l1

\\s a

tI

(

n At

/-

y n p' c

n Ii n

=

So

/

e SP

'vL' uq ns

\\

/

e ds r

Fa

,/

/

F M

li

/

i e

c f, /

a1 0

0

'j ui f

2 rt Sn U

E Gg En s

s i

m e

e fd u gi g3 ol r nt nt t i rir i

nu c sese oB p

o o

eUpUp sir S srsr ro iP iP at n s s

pc D yl yl ma i li li oe I

s aoao CR 0

d e nS nS 0

C.

0 0

0 e

0 0

D.

c. 1 n

D A A

08 4

2 o

e s

4 2

e C

E g

C E P ED 11 1

1 gw

  • eb?u4 e

P DGGE x

L G E E

5 8/

5 0/

7o V

2 TLP SR i

ll

2 0

a e

1 e

g n2 e

i c e

p e m s a/

a D t f

3 e

75 n s

i t

d, a

a sn

\\ -

a o r i s

t t c a f

e 1

e r

\\

a 0

p e 1

s sl z

t l c a

e e

o l c

\\

a N A A

\\

f

)

g

\\'

a z

A H

\\

D n

a

(

\\

/

y

/

a c

p s '

n

\\'

/

e I

\\

u f

a q

\\

\\

e

't

/

r s/,i F

t }

e 0

a 2

a a

e a

s s

s m

e e

u gi gi a

r nt nt t irir c se se eUpUp a

p o

o S sr sr i P iP n s s

D yl yl i li l i s ao ao

e nS nS 0

d C.

0 0

0 0

0 g 1 n D A A

00 5

0 5

0 5

e C

E 1 3 2

2 1

g C EP EG C0ee

, e O#

e P GG GE

-r I

L G E E

llll l4 jl

~

4

. S

- R.

.EM OC TLP 0

n 1

ao E

ri A

g tt n2 cc A

i c ee A

p e pr ms Si.

a/

D a

D t n

f gW a

i.

sE 5 n T,_

i e

t D

C_

- n Ct.

as 3

)

ao Pf 7

ri G

7 t t 5

c a h8-5 e r t1 0

p e i

N.-

E 1

s sl wv N

i S

e e

e t

l c sl

\\

N R

N A A s(

o l c eE

\\

)

\\

z y

\\

A H

l4 a

f E

(

(

n s

At.

l

/

,s S

c y

n Ii 1 \\'

n So e

t SP u

\\

/.

q

\\

t ns n

/

e ds-s)1 r

Fa l

F M-t e

/, /

c 1

0 a2

/

3 1

f rt.

A ui.

9 Sn i

U e

E Dg En s

s i

e m

e e

fd u gi gi ol

_3 r nt nt i

t 3 rir c sese nu oB eUpUp s

p o

o ir 3 srsr ro iP iP at n s s

pc D yl yl ma 1 li li oe s ao ao CR e nS nS 0

d 4

3, 1

1 n

D A A

e C

E 0

1 g

C E P ED CO o. eLeneuN e

P DGGE X

L G E E

58/5 0/

70V 2TLPSR

0 1

Dn2 i c p e ms a/

D t f

s _

p,__

5 n i

t as

.N n

a o w

v ri t t c a e r 0

sl p e

%.1 s

s e

e g

3 x

/'

t l

c o

l c

'v N A A

' \\

)

\\

z H

A

(

A

/

1'

/

y

/

s jv c

\\'

n

/(

e

\\ /.

u

\\

q

/

e t

)

r P

F

/-

/ r /)

1,

o t

s s

m e

e u gi gi r nt nt t irir c se se

^

eUpUp

^

p o

o S sr sr iP iP n s s

g yl yl i li li s ao ao

c. 1 n D A A

0 d:

e nS nS 2 :

5 t.

0 e

C E

1 g C EP EG C3o.ebmeE>#

e P GG GE s

X L G E E

1l

)ji1!ll' il l

,l 1

B R.

N MOC TLP 0

n 1

ao ri g

tt n2 cc i c ee p e pr ms Si a/

D D t n

f gS i -

5 n sN

\\ __

De~,

i t

N as

)

n Ct ao Pf ri G

t t 7

g\\

c a h8

'N e r t

f 0

p e i

s 1

s sl wv 5sN e

e e

t l c sl o

l c eE N

A A s(

1 L

s' H

)

y z

\\

lia

\\

\\

[

nAt

,t y

n l

c Ii

/y n

So e

SP

/

\\

gh uq ns

's

/

e ds r

Fa i( r/

F M

/

e c

a1, f

/

0 f

/'

1

/

ui rt Sn 1

U E

Gg

/

m e

e En s

s i

fd t irir u gi gi ol r nt nt i

nu c sese oB eUpUp s-p o

o ir S srsr ro iP iP at n s s

pc g yl yl ma i li li oe s aoao CR 0

d e nS nS c.

0 0

0 0

0

c. 2 n

D A A

e C

E 0s 4

2 o

B s

4 2

g C EP ED e

P GGGE 1i 1

1 g* %h m8X X

L G E E

5 8

/50/

OV 2

TLPSR

l l

.ii ll jj1 j,

!,ll!

l!l1; lII 28 R.

4WOC TLP s

2 0

n 1

ao ri tt g

n2 cc ee i c pr p e Si m s D

a/

n D t gS f

i-5 n sN

~

D i

e t

~

as

)

n Ct ao Pf G

s' ri t t 0

c a h3 e r t1 v

%s\\

1 s

sl wv i

0 p e e

e e

t l c s3 o

l c eE K,

N A A s(

y

)z l2 sN H

a b

At

(

n

  • ~

y n

7 c

Ii n

So I/ d e

SP o.

u

(.

q ns e

ds p

r Fa F

M e

c y

a1 O0 f

1 ui rt Sn

/ '

U E

Gg En s

s i

m e

e fd u g$ gi o3 r nt nt i

t irir nu c sese oB eUpUp s

p o

o 3 r S srsr ro iP i P at n s s

pc g y1 yl ma ill li oe s aoao CR 0

d e nS nS 0

C.

0 0

0 D.

0 C.

n DA A

2 e

C E

00 5

0 5

0 5

g C E P ED 1

e P GGGE CO*ee he3ou4 13 2

2 e

L G E E

r X

58

/50/

70V 2

TLP SR

E T

E 1

2 0

M g

n2 ic p e m s a/

D t f

<1 5 n i

t E

N*~

asn ao ri Q

t t K\\

e e

c a e r

' 0 p e E

1 N

s sl N

u t

l c o

l c N A A

)

\\

z E

e H

A

^s '

(

/.

c y

,4 n

fr E

q eu

,f e

r F

E

0 1

E-m e

s E

r nt nt u gi gi t irir c sese eUpUp E

p o

S srsr iP iP n s s

D y) yl i l i li

e nS nS s ac ao E

3 2

C.

n D A A

d d

s i

0 1

e C

E 8 w p Eo E84 g C EP EG CX e P GG GE L G E E

D E

20 1

g n2 i c

=

p e ms a/

=

D t f

\\,

J.

5 n 2

A_-

tas n

ao

0 p e ri t t c a e r x

1 s sl e

e f

t l c o

l c

\\X N A A

\\

)

z H

w v

(

/

/-

y f

cn f

eu s'-

q e

e,-

r F

00 1

s s

m e

e u gi gi r nt nt t irir c sese

~

eUpUp p

o o

S sr sr iP iP n s s

g yl yl i li li s ao ao

e nS nS 0

a

+

o 5

0 n D A A

1 0

e C

E 1

g C EP EG COwee b,u-euN e P DG GE X

L G E E

l L

)

l CASE 2 9

REACTOR BUILDING EMBEDDED FOUNDATION VS. DESIGN UNIT 1 GROUND MOTION i

2 0

1 g

n2 i c p e ms a/

D t f

5 n i

n ta s h

n ao

\\C ri t t c a N#

1

sl e r 0

p e g\\'

N A A s

e e

t l c o

l c

\\

)

z

\\

H N

\\

(

\\

y

[%

cneu q

r e

r g

F 0

1 y'

s s

m e

e d

u gi gi r nt nt t 3 rir c se se eUpUp p

o o

S sr sr iP iP n s s

g yl yl i li li

s ao ao 0

d e nS nS C.

0 0

0 D.

0 0

g C.

n D A A

1 05 4

2 0

B B

4 e

C E

g C EPEG 11 1

1 4Owee I me>u N e P DG GE X

L G E E

0

.1 g

n2 i c p e m s a/

D t f

5 n sQ i

t as n

N ~-

a o ri s

t t c a X

e r s,_

. 0

p e 1

s sl

\\

~

e e

t l c o

l c

\\

N A A g

)

\\

z

/

H

[

' /

s' y

N cn eu q

e r

F

/

0

/,.

1 s

s m

e e

u g3 gi r nt nt t irir c sese eUpUp p

o o

S sr sr iP i P n s s

g yl yl i li li s ao ao

e nS nS 0

d 1

C.

0 0

0 D.

0 c.

n D A A

e C

E 00 5

0 s

0 5

1 g C EP EG 13 2

2 t

e84 e P DG GE

)

8.ee !,r X

L G E E

lI

0 1

g n?

i c p e m s a/

D t f

s' 5 n i

t a s n

a o ri t t N

c a

- : 0 e r N

~

1 p e

~

s s l s

~

e e

\\

t l c

\\

o l c 1

N A A

\\

\\

z

)

/

s H

/

(

/ 4 c

y Y

ne

,sr u

q e

'7 r

F

0 s'1 s

s m

e e

u gi gi r nt nt t irir c se se p

o o

eUpUp S sr sr iP iP n s s

g yl yl i l i li s ao ao

~

e nS nS e.

3 2

c.

n D A A

0 d

2 1

0 e

C E

1 g C EP EG Co eeLO.ouy e P DG GE X

L G E E

20 1

D n2 i c p e m s a/

D t f

^

n,.

5 n a

r t

a s

\\

~_

n a o r i t t N

c a

,~.1 e r g

. 0

sl p e 1

s

\\

N e

e

\\

\\

\\

t l c o

l c

\\

N A A

~

z

)

/

/

H I

f

/

(

)^

c 7

y p,

ne u

q e

/,

r F

s s. '0 1

s s

m e

e u gi gi r nt nt t 2 rir c se se eUpUp p

o o

S sr sr iP iP n s s

Q yl yl i l l li 1

s ao ao 0

d e nS nS 6

+

2

c. 1 n D A A

0 e

C E

1 g C EP ED C0eEe2o#

e P DG GE X

L G E E

l.

l l

l l

1!

(}ll!

i ilil i

a R.

N MDC TLP 0

an 1

ro ti D

ct t

n2 ec i c pe p e Sr ms i

a/

nD D t g

S f

i

~

K s-5 n eN i

D t

as C) n Pt ao Gf ri t t h7

\\ '\\

c a t8

/ ~'

0 p e w

e r i

\\J 1

s sl v

e e

se g

g t

l c e3 o

l c sE

\\

N A A y(

)

\\

z l

H a1 N

,\\

(

n A

~

s' c

In y

t

/g\\"

n Si e

SoP u

j#

q n

e ds r

Fs a

dM F

/[

0 e

d2 d

/

U 1

e.

mi bt En EDD En s

s m

e e

i s

r nt nt fd u Dj gi ol i

t 3 rir c sese nu eUpUp oB s

p o

o ir S srsr ro iP ip at n s s

pc D yl yl ma i li li oe s aoao CR 0

d e nS nS 0

C.

0 0

0 0

0 0

0

c. 1 n

D A A

0s 4

2 0

s s

4 2

e C

E 2i 1

1 1

g C EPED C

eebme 4 e

P GGGE x

L G E E

58

/50

/

7 o

V 2

TLP SR

!JI' ll1l1l\\i v.

g g

2B R.

N MD C

TLP a ;_

2o an t

ro n-ti

. g ct n2 ec i c pe p e Sr ms-i a /e nD D t -

g 7

i S M.

s-5h eN i

D K.

t as C)

Y~

n Pt ao Gf ri la t t h0 c a t3

~.

~

1 e r i1 0

p e w

%~

e e

se 1

s sl v

Ny' N

A A y(

N t

l c e3 o

l c sE

)z l

g s

H a2 N

[

nA' y

t c

In 7"

q n

n Si e

SoP u

g#

ds e

r Fs a

dM F

r e

d1 d

J

. 0 0

1 s

- bt mi

/,

Gg En U

E En s

s i

m e

e r nt nt fd u gi 0i ol e

i t 3 rir c sese nu eUpUp oB s

p o

o S srsr ir ro iP iP at n s s

pc g yl yl ma ili li oe 1

s ao ao 5

d e nS nS CR

- C.

0 0

o.

0 e_ 2 n

D A A

00 3

0 5

a 5

e C

E 1

g C EPEG 13 2

2 Co4 e eb,,e u2 e

P D G GE X

L G E E

58/SO

/7OV 2

TLPSR lf1I

'I l

lll(ll[1I llt1 llll l

~

0 1

Dn2 i c p e m s a/

D t f

=

5 n i

t S,

a s s,-

- n

'a o NN r i t t s 'N c a 1

e r a

0

sl p e 1

s

=

e e

s,%

N A A t

l c o

l c I

A ~s-

=

(

)

=

z H

~_

a c

y r

n e

/'

u q

/..

re s.'

F f-

0 1

=

s s

m e

e u gi gi r nt nt t irir c sese eUpUp p

o o

S srsr iP iP n s s

D yl yl i l i l i s ao ao

e nS nS 0

d C.

n D A A

2 1

1 0

e C

E 1

g C EP EG COer e oh,e t I4 e P GGGE X

L G E E

l1!

.i' g

2 w

2 R.

N MOC

~

TLP m

0 an 1

ro ti g

ct n2 ec i c pe p e Sr ms i

a/

nD

~ ~ ~. '

D t g

f iS K

s-S n e N, D

~,-

t -

as C) n Pt y _,

ao Gf ri "s

t t h4 c a t0

~-

0 p e w

e r i2 1

s sl v

. k!.

\\

e e

se t

l c el o

l c sE s

N A A y(

z

)

l H

a2

/

n2

/ -

(

A t y

c In Si n

So e

P u

f_

q n

ds e

Fs r

a e

dM F

e d

di 0

0 e

1 mi bt En U

E Gg En s

s i

m e

e fd u gi gi ol r nt nt i

t i rir nu c sese oB eUpUp s

p o

o ir S srsr ro iP iP at n s s

pc g yl yl ma i li li oe s aoao CR 0

d e nS nS

+

5 2

C.

n D A A

1 e

C E

0 1

g C EPED C0 ee<eneoa4 e

P DGGE X

L D E E

58/5 0

/

7o v

2T L

P S

R llll I

i

P' s

L CASE 3 REACTOR BUILDING SURFACE FOUNDATION-VS. DESIGN UNIT 2 GROUND MOTION

0 1

g n2 n i c o p e i ms t a/ o D t m f

d 5 n3 i c t

i e

u a sfn a o e

\\m ri e

\\}

\\

t t r

\\

\\

c af

\\'

0 p e2 e r

(

\\

1 s sl -

/

r e

et

\\

l

\\

t l ci k

+

N A A U o

l c n t'

)

n' z

\\

H 1

l

}

~

(

l y

[

1'

~

c i y <

ne J

,,l u

'\\'

\\'

q

\\

e

%1*

l I

(i

/

r 1l, F

',8 l

N

\\-

i I'i

,f 0

o 0

f ]

1

'/

l f

  • }

l e

s s

J m

e e

u gi gi

/

r nt nt t irir c sese eUpUp p

o o

S srsr iP iP n s s

g yl yl i l i li

s ao ao 0

d e nS nS 0

C.

D.

0 o

0 0

0 0

e, n D A A

1 06 t

2 0

e s

A 2

e C

E g C EPEG 11 i

1 9 Uok;au4 i

e P DGGE X

L G E E

Il'

~

~

0 1

D n2 n i c o p ei m st a/ o D t m

. f N

d S n3 i e t

l g,

a sf n

s n

j ~,

aoe t'

i e

\\

h t r h

c af

. 1 e r' s

. 0 l

~

p e2 1

Vg:

t l ci s sl e

- et v

N A A U o

l c n

(

\\

\\

g, 1

k.

)

{

t \\

{

z H

/

g

(

I

\\

1 y

n\\

c

/

n e

\\,

t1 1 t I 'Y u

. [

q N'g I

i; 8

/

e r

/

F i

/es

i t

/

/

/

. 0 1 J' 0

1 j

j-

'a

/

s s

m e

e r.

u gi 0i r nt nt t i rir c sese eUpUp p

o o

S sr sr i P iP n s s

g yl yl i l i li 1

e nS nS 0

0 0

D.

0 o.

s ao ao 0

d g

1 00 5

0 5

0 5

e C

E n D A A

13 2

X 2 co;ehm&8a 1 g C EP ED e P GGGE L G E E

m 2

0 1

g n2 n i c o p e i m st a/ o D t m f

. d 5 n3 s-

.i c t

a s-asfn

, ~ -

a o e ri e N ~~

t t r c af s~

e e t

. i e r

. 0

p e2 1

v s sl

\\

,~

t l

c i

\\

}

o l c n

\\

N A A U

\\

- \\

s z

)

\\

}

N l

A H

i(

(

/

g l

\\-

y i

A c

\\

A n

f\\

e t

Y u

5 t

1

,iilI 4

q i

/

sta j

e J

t 1ij

/

Fr t

t i'

/

's e,/

. 0 i.

0

~,4 1

W

/..

s s

m e

e u g$ gi r nt nt

'c.

t irir c se se eUpUp p

o o

S sr sr iP iP n s s

g yl yl i l i li

~

e nS nS s ao ao

+

-3 2'

0 d

1 e_ 1 n D A A

0 1

e C

E co emL*r-1eu2 g C EP EG X

e P DGGE L G E E

0 a

1 e

a g

n2 n a

i c o a

p ei m s t a/ o a

D t m f

d L_a 5 nl i e Ae t

i a sf f

n s

y a o e y

r i e t t r J

c af

/

e r

\\

s a

0 p e2 y

\\

a 1

sl s

\\

[\\

e e

et e

t l ci

\\

i}f a

N A A U 0

l c n

\\

t a

z

)

\\

\\

H 0

\\

e

(

j I

J r

i tJ al y

A a

c I

\\

n

)t ),

e

\\

u

\\

t I

e q

(\\

,I I8 I J

e i.

r l t) f F

a s j.

a 1

a 0

ju e

/a a

a se s

s m

e e

u gi gi a

r nt nt t i rir c sese eUpUp p

o o

S sr sr i P iP n s s

D yl yl i

l i li

s ao ao 0

d e nS nS 6

+

2 g

3 n D A A

0 1

e C

E g C EP EG c b rem *uu4 e P GG GE X

L G E E

2 0

1 g

n2 n i c o p e i m st a/ o D t m f

w_

d 5 nl i e t

i a sf y~

n a o e

% ~

r i e

\\

\\

b t t r h

3

0
sl c a f e r

\\

p e2 s,

1 B

\\'s e

e t s

t l c i

\\

o l c n

/

i

)

N A A U t

s i

l

}k z

\\

H

}

g

~

(

It e'

s y

i c

y g}

n f

/ /

eu g

\\\\

i I '( t it f

q i sl

'g j

la er i l,

/

F I

/g

/

gt f

l 3

i t

)

0

- 1 j/

l,l 1

I7 s

s m

e e

u gi gi r nt nt t i rir c sese

/ '

p o

o eUpUp S sr sr i P iP n s s

g yl yl i l i li

s ao ao 0

d e nS nS 0

C.

0 0

0 0

0 o,

0 c.

1 n D A A

08 B

4 2

0 s

5 4

2 e

C E

11 1

1 1

g C EP ED co+ $Le"* o*

e P GG GE X

L G E E

0 1

g n2 n i c o p e i m s t a/ o D t m f

d 5 n3 i c t

i 3

asf g

n a oe N __

ri e t.

t r

'N r a f e r 0

p e 2 1

sl vT e

et s

t l c i o

l c n N A A U s

)

sb {

z s

H i

(

y c

l n

/

e u

/

q 1

1 s

e Y) f r

/f F

/

I k s5 1

0

.T

/

m e

e s

s u gi gi r nt nt t i rir c sese eUpUp p

o o

S srsr i P iP n s s

D yl yl 1

l ili

s aoao 0

d e nS nS 0

C.

0 0

D.

o.

0

c. 1 n D A A

00 5

0 5

o 5

e C

E g C EP EG 13 2

2 C3eeh,euu# n e P GG GE x

L G E E

ll

i

\\llji!

!l i l t3 w..

4 B

R.

4W C.

2T LP

~.

20 1

n ao g

ri tt n2 n cc i c o ee p ei pr m3 t Si.

a/ o D.

D t m n

f

.C gS 5 n ]d i -

sN

~

3 e t

e 3

D a^-

asf n

C )t aoe Pf s

ri e G

bN t t r 5

c af

\\

h8

.\\

0 e r t1

\\

p e2 s

b j 1

i s

sl wv e

et

\\

\\

\\

t l ci e

sl A

o l c n eE i

g b1 N

A A U

)

s(

\\

z y

H 5 f 34 1

\\'

(

a

,V n

y At tf c

w

/

n n

Ii e

So

/, '

qu SP

/

e w

l[,

ns r

ds F

Fa

[

1 M

e 0

c 0

a3 r

f rt Sn w

ui l

U E

Gg n.

s s

En a.

e e

i u g3 gi fd

~

r nt nt ol t 3 rir i

u c sese nu eUpUp oB p

o o

s S srsr ir iP iP ro n s s

at g yl yl pc il l li ma

~

c.

1 2

C_

n D A A

s aoao oe 2

~

0 d

e nS nS CR 1

'0 1

1 e

C E

Co4,s>m b 7 3 4 g

C E P ED x

a e P DGGE L

GE E

5 8

/

w 5

0

/

70V 2

TL P

tit fjl l1l i1l S

2 s

m a

a g

n2 n a

i c o s

p ei m s t a/ o a

D t m f

e K

d S nl i e a

a sf t

i n

a oe 1 -

r i e t t r 4

c af

^N e

1 e r 0

p e2 e

1

sl A..Os%

e t

l ci g

a e

et s

s o

l c n

\\

U a

N A A U

\\

)

,/

a z

\\

H

\\

f a~

a

(

/

l

/

y t

e c

/,

n e

/

u e )

a q

f e

r F

raa 1

0 0

a a

~'-a

~

a m

e e

a s

s u g3 gi r nt nt t i rir c sese

~

eUpUp p

o o

S sr sr iP iP n s s

g yl yl i li li s ao ao 0

d:

e nS nS 5

4 g 1 n D A A

0 e

C E

1 g C EP ED COeeo m*"X e P DG GE w

s I

L G E E

l

a~

i, U

11 i

l CASE 4 i

N.

REACTOR BUILDING EMBEDDED FOUNDATION g

VS DESIGN UNIT 2 GROUND MOTION u

e i

A i

N o

R R

,:lj) lI4 i

4:

n n

r e"

gs.

n'

=_

=

20 1

a-r-

g t4 ct n2 n e-i c o p-p ei mst Sr

_ 7 a/o a

nn D t m g

% e.

d s-f iv t

ss, 5 n3 eF 7

%y t

i ic D

asf m

CI

/

n PF

~

aoe GF

\\%#

0 i

ri e t t r i7

?

t c af ttR e r p e2 w

w1 e

et 1

s sl v

\\.

se

.\\

N A A U t

l ci 9

el

\\

o l c n sE

\\

\\

)

y(

\\

z l

T 1'

H a1 5

k

(

n N

\\

A n

y t

n c

In V

~

n Si

\\

e So

/

u

/

P bf q

n e

ds

/ '/

r

/

F Fs f

a dM 4

e

' 0 di.

d T

0 1

e bt En mi U

.~

E Gg

/

s s

En m

e e

i u gi gi fd

.~

r nt nt ol t 2 rir i

c sese nu

/ :

p o

o s

eOpUp oB S srsr ir iPiP ro y

n s s

at D yl yl pc ili li ma 0

C.

0 0

s aoao oe 0

0 0

0 0

c.

n D A A

r d

e nS nS CR 1

06 4

2 8

s 4

2 e

C E

g4 mS ee$S8<

11 1

1 3

X g

C E P EG e

P GGGE L

G E E

58

,1

/5 0

1L~

/7O 1

V 2

T 1

LP S

R l'

2 0

1 g

n2 n i c o p e i m s t a/ o D t m f

M_

d 5 n3 i e g.

t l

\\ s a sfn

/

a o 'e f-ri e t t r

\\

c af 0

p e 2 e

r' s

1 s sl e

e t

\\

^

N A A U t

l ci

\\

o l c n

\\

\\

\\

\\

s' z

)

J

\\

H I

\\

/

T

(

f f

y c

f','

q neu f

e

/

r "r

F

/

0 s

1

/.

/,.

r nt nt s

s m

e e

u gi gi t 2 rir c se se eUpUp p

o o

S sr sr i P iP n s s

g yl yl i l i li

s ao ao 0

d e nS nS 0

0 0

0 0

0 0

c. 1 n D A A

00 5

0 s

0 5

e C

E 13 2

2 C 3 e e h,,8 N 1

g C EP EG e P GG GE X

L G E E

0 e

1 a

e g

n2 n a

i c o a

p e i m s t a/ a a

D t m f

~

e d

5 nl i e t

i e

a sf n

a o e ri e N

t t r c af

~

e r N

~

a 0

p e2 s sl a

1 s

a e

et

\\

N e

t l ci o

l c n

\\'

a N A A U

)

4 a

z l

H I

/ s_

e

(

l

/

y l

a c

iv n

e u

'8 )

e q

e r

/

F a

0 e

e 1

e a

"a' a

m e

e s

s ys u gi gi r nt nt t i rir c sese eUpUp 2

p o

o S sr sr i P iP n s s

g yl yl i l i l i s aoao

e nS nS 0

d A.

3 e.

1 g 1 n D A A

0 e

C E

1 g C EP ED Co e?e~eoy e P GGGE X

L G E E

s 1

l

.)l 22 R.

E C

M E

T LP 2

0 a

1 an ro e

ti a

g ct r 2 n ec a

i c o pe a

p ei Sr mst i

a/o nD a

D t m g

f iN s

a d

s-a 5 nl eE i e D

t i

asf C) n Pt w

'a oe Gf N

ri e t t r h4

%a u

c af t0 e r i2 y

a 0

p e2 w

1

\\

s sl v

\\

s e

e

~

et se N'

\\

a t

l ci el

\\s' -

e N

A A U y(

o l c n sE

(

)

/

n' e

z l

/

H a2 l

as e

(

n2 l

I A

y t

f a

c In y

f n

Si e

So u

P

,y[

e q

'n e

ds r

Fs

/

F a

dM e

d1 a 0 d

a 0

1 a

e b't mi En e

U EGg En s

s i

m e

e u gi gi fd i

r nt nt ol i

t irir c sese nu eUpUp oB p

o o

s S srsr ir iP iP ro n s s

at D yl yl pc ma i li li s aoao oe 0

d e nS nS CR 2,.

5 4

2 g 1 n

D A A

0 e

C E

1 g

C E P ED c

vEeoo8'

-e e

P GGGE X

L G E E

58

/

5 0

~_

/

7 OV 2

TLPS R

n_

-g i

- 8 R.

N C

M E

T L

P

=

2 n

an g

ro ti D

ct n2 n ec i c o pe p ei Sr ms t i

a/ o nD Dt m g

f iS

, ~-

d s-5 n3

.eN i e D

t j

. C ).

asf

~, "

n Pt aoe Gf

~_

ri e t t r h7

\\ s ~.

c af t8 MA z

1 e r i

J 0

p e2 w

1 s

sl v

A w

e et se

\\

t l ci e]

N A A U y(

o l c n sE y\\

t' l

)

g\\

g't

=

z g

H ai n

u

=

(

\\

A y

t

\\

w

=

c In n

Si s\\s\\

e So u

P

[L g q

n-

/

ds e

r Fs a

~

dM F

e f

~

d1

,-0 0

e 2

~

mi bt En

/

U E

Gg En s

s m

e e

i fd u gi gi ol J

rnt nt i

t i rir c sese nu

/

eUpUp oB s

p o

o S srsr ir ro iP ip at n s s

pc g yl yl ma i li li oe s aoao t_0 CR d

e nS nS 0

C.

0 0

0 0

0 0

0

c. 1 n

D A A

0B 4

2 0

B S

4 2

e C

E 1i 1

1 1

g CEP ED co % Le"e u4 e

P GGGE X

L GE E

5 B

/50/7ov 2TLPSR ll{

[

2 0

a 1

a a

g n2 n e

i c o p e i A

m s t a/ o D t m f

E d

5 n3 i e

~ _

t 3

a sf t

A n

t t r a o e r i e s

c af

~ %

E 1

e r 0

p e 2 E

1

s l s

8 e

e t 9

t l ci

% ^

o l

c n

\\

9 N A A U

)

\\( \\

8 z

H 9

(

l s

y r

S cneu y<

R q

e

/,'f r

F E

0 B

1

/

B A

9 A

R s

s m

e e

u gi gi a

r nt nt t irir c sese eUpUp a

p o

o S sr sr iP iP n s s

D yl yl i l i li 1

s ao ao 0

d e nS nS C.

0 0

D.

0 0

n D A A

1 00 5

0 5

0 5

e C

E 1

g C EPEG 13 2

2 C 0 ee h,eeuN e P GGGE X

L G E E

M

i1jll

!l w

4 B

m R.

N C

M ET.

L 7

P 20 1

an ro ti D

ct n2 n ec.

i c o pe p ei Sr mst i

a/ o nD D t m

. g f

iS d

s-

~,

5 nl e N.

i e D

t i

b~

asf C) n Pt aoe Gf ri e

\\

t t r h5

\\ '\\

c af t8 1

e r i1 Q

0 p e2 w ~v 1

s sl N'-

e et se t

l ci el

\\ p_

N A A U y(

o l c n sE

\\

)

\\

~_

z l

H a4 I~

n l

(

~

. A s

y t

. \\

~

c In r

^/

n Si e

So

~

q n

u P

/

e ds r

Fs

/

F a

dM e

4 d

0 1

d3, 0

e mi bt En U

E Gg En s

s m

e e

i u gi gi fd r nt nt o3a t i rir c sese nu eUpUp oB p

o o

s S srsr

. ir i P ip ro at n s s

g yl yl pc

~

ma i li li 1

s aoao oe 0

d e nS nS CR 4

2

c. 1 n

D A A

s 0

e C

E 1'

g C E P EG COeohme b e

P GGGE X'

L G E E

5 8/

S O

/

7O V

=

~

2TL P

SR

~

(l

!ll l

2 0

a 1

a a

g n2 n e

i c o a

p ei m s t a/ o e

D t m f

q_

e d

5 n1 i c t

i c

a sf t

a n

a o e r i e

\\'

t t r I '

c af e r r"

e 0

p e2

}'

e 1

s sl -

s\\

a e

et y/

a t

l c i o

l c n

'\\

's e

N A A U

)

\\J I

a zH

/

/

h

(

I

~

y A

~,

e cn

/

eu e

q e

r F

a 0

e 1

e a

a t

- e m

e e

s s

- a r nt nt u gi gi t irir c sese eUpUp p

o o

S sr sr i P iP n s s

g yl yl i l i li

s ao ao 0

d e nS nS

+

7 6

1 n D A A

+

e C

E 0

g C EP EG 1

COee 0m4uo4 e P DGGE I

L G E E

,l

I l

OBSERVATIONS AND ' ONCLUSIONS C

g FOR THE REACTOR BUILDING CASE 1 SURFACE FND/ UNIT 1 GROUND MOTION

  • SUBSTANTIAL CONSERVATISM EXISTS IN DESIGN RESPONSE DUE.TO SSI/ STRUCTURE ANALYSIS PROCEDURES EVEN IGNORING EMBEDMENT
  • IN GENERAL, BOTH SOIL PROFILES SHOW CONSERVATISM. HOWE"ER, LOW FREQUENCY RESPONSE FOR THE SOFT PROFILE SHOWS SOME EXCEEDANCES.

l CASE 2 EMBEDDED FND/ UNIT 1 GROUND MOTION eVERY SUBSTANTIAL CONSERVATISM EXISTS IN DESIGN RESPONSE WHEN EMBEDMENT EFFECTS ARE INCLUDED FOR THE SOFT PROFILE: COMPARABLE RESPONSES FOR THE STIFF PROFILE l

i 2~ 2

'~ :ha

h

[e y

OBSERVATIONS AND CONCLUSIONS

\\'

FOR THE REACTOR BUILDING (CONTINUED) l

)!

CASE 3 SURFACE FND/ UNIT 2 GROUND MOTION

-)

  • N - S DIRECTION -- DESIGN RESPONSES ENVELOPE ABOVE FOUNDATION
  • E W DIRECTION -- EXCEEDANCES AT LOW FREQUENCIES CASE 4 EMBEDDED FND/ UNIT 2 GROUND MOTION l
  • DESIGN RESPONSES ENVELOPE EXCEPT FOR SLIGHT EXCEEDANCES AT LOW FREQUENCIES

, e d_=

W$

_.I THE UTILITY'S DYNAMIC MODEL FOR THE CONTROL g,.

ft BUILDING WAS USED IN THE ANALYSIS f,C 1

I 4

m. 141'. e*

3 I

g I

@g

  • g

~

,e... e.

s

m. _ e.Og e

g

_ i; A

IN*g m

m._ e.

im _

b 9

  • g m_ m.. e.

T i

l

@g m.

1,,.. e.

Mi x h

m. 1e,.. e.

A_

x (Baw Sieb)

A, 5

~ _.. _

-m.

J.

1 f

i I

CASE 5 i

CONTROL BUILDING SURFACE FOUNDATION VS. DESIGN UNIT 1 GROUND MOTION h

i

0 1

g n2 i c p e m s a/

D t f

~_

7 5 n N ~_

i t

s, a s

~

n a o s

r i t t n

~

c a

~

1 e r

~

- 0

sl N

p e 1

s l

N e

e N

t l c o

l c N

N A A

)

z

,\\

(H n

s y

cne A,

qu e

/

r

/

F

~

00 1

s s

m e

e u gi gi r nt nt t irir c se se p

o o

eUpUp S sr sr iP iP n s s

D yl yl i l i li

s ao ao 0

d e nS nS 0

C.

0 0

D.

0 0

c. 1 n D A A

00 5

0 D

0 5

e C

E 13 2

2 1

g C EP ED C0eremh oUN e P GG GE X

L G E E

w 2

0 1

g n2 i c p e m s a/

D t

~

e __

f 5 n i

t.

a s n

a o ri Ns : 0 p e t t c a e r N

e e

1 s sl f

N

=

t l c o

l c 1

N A A z

)

/

~

H

/ %

(

y s

c s

n e

e uq e

'e r

/

F s_

= 0

0 1

=

s s

m e

e u gi gi r nt nt t i rir c se se eUpUp p

o o

S sr sr iP iP n s s

Q yl yl i l i li s ao ao

e nS nS

+

0 d

-3 S,

c.

n D A A

1 1

0 e

C E

1 g C EP EG c3eeCemeuo e P DG GE X

L G E E

f.

l

w 20 1

g n2 i c p e m s a/

D t f

5 n

~

i t

a s n

~

a o ri t t c a

1 e r N

0 p e

_'1

sl s

s' e

e m

~

t l c o

l c

~

N A A

/

,N z

)

H

/

(

/\\

s y

cn q

eu f,

e r

/

F

00 1

s s

m e

e u gi gi r nt nt t i rir c sese

~'

p o

o eUpUp S srsr iP iP n s s

D yl yl 1 l i li s ao ao

e nS nS

}

4 1

o.

c. 1 n D A A

0 d

1

'0 e

C E

1 g C EP ED cOeoeb,,eu e P DGGE w

I L G E E

j; Ii(l

,(i

Q 0

1 g

n2 i c p e m s a /

D t f

\\

5 n i

~

t

\\

a s s

m n

a o u

r i

\\

t t s

c a s

e r N

0 p e

'\\

1

s s l

\\

e e

1

\\

\\

t l

c g

\\

o l

c s

\\

s N A A

)

\\

s' z

f H

J

,\\

[

/

c y

n J) q eu

, f e

~

r

/

I F

' /,/

/

g(

1 0

f

/r

/,

r nt nt s

s m

e e

u gi gi t i rir c se se eUpUp p

o o

S sr sr iP iP n s s

D yl yl i

l i l i

s ao ao 0

d e nS nS 0

0 0

0 0

0 0

0 0

n D A A

1 05 4

2 0

0 S

4 2

e C

E g C EP EG 1 1 1

1 32 e, O u4 e P DG DE X

L G E E

I

]l),

J W

3-7 B

C.

5 7:

lN 9

0C T

L J.

'v

~P

+

s,

- +

0

'W 1

n ao 2_

m ri g

tt n2 cc s'

i c ppr ee p e

.- u [;

Si m s a/

D

\\.

G t

.n

. % 'r,. _ s. g f

_i-N 5 n sN

~1 i

e t

wD as m,' 's C l i.

n Pf u

ao

~- G t

r i t t 7

1 t

c a h4 1'

c, 1

e r t1 0

p e i

,V.

wv 1

v s

sl

\\1 e

e

_1 e

t l c a

sl

\\

,',s ?

2

-.y a\\'

o l c eE N

A A s(

]

f H

,~l7 l

a -

s,

(

n

,\\

c n

y At g

/

n Ii e

.NEo

,b[

qu

.SP l

ns e

r ds Fa M

/

F f

y-e c

a3.

0 1

f rt ui Sn

(~

U 7,'.

E' O9 %

,r EQ #

s s

t -

m~

e

=-

u g2 g 2, -

(4_,

r n *.

nt~

J }*-

w i

t i rir c so nu eUPk6

~

p oB Sc s

e p

c il S sr sr ro iP iP ar n s s

pt r

S ao ao Q yl y1 mn i l l li oo 5

d e nS nS Cc 4

3 2

o, 1 n

O 'A A

,4 1

0 e

C E

1 g

C EP ED COwemLemouu4 e

P GG 0E X

L G E E

2 h

0 6

/

,5

,'~

'w 0/7o*

v 2

e.

s-7 1

~~

56

~

F i-

~-

~

,llIll l

l

.y C_

.N m

x_

7 p

b

~

C.

m_

a N

  • q.,.

-; ~

6O C

s T

P L

.p m.

s

,y; s.,

\\' -

^;,

u

- -g 3

4 w

'-g h

.s N

a qg ;,-

!2 l

0 1

n ao m

"?

ri g

tt 4

.,N.

9 i c ee n2 cc u

e s~

p e pr m s Si u

a/

D NN O t n

f gS 5 n sN i -

u a

e t

D s

a s l

4 n

Ct

~

ao Pf s-ri G

w t t 0

N -

n1 c a h8 e r t1

\\

0

p e i

i x',

1 s

sl wv

%q(.

e e

e I.

S x_

)(H t

l c

sl

,\\

9 ("

r o

l c

eE

\\

,[:f.

4 t

N A A s(

f f

z y

,t g'

x T,

f f

j l7

/

/

a f/'N

/

n 6

1 y

At a

f c

n y

n Ii c;

m.

e So b/

u SP

+4

. N y

q

~

\\

e ns x

r ds

}

.a Fa

/

F M

-u_

n

~

J'r e

c

. 0 f_..

1 a1.

~

0 f

rt m

ui Sn Y,:-

Dg c.

U

~

E m",

r En s

s m

e e

i s

f d u g3 gi ol e nS nS CC r nt nt i

t arir A

c sese nu A

eUpUp oB s

p o

o il S sr sr iP iP ro n s s

ar pt g yl yl mn

-t i

l l l i oo 1

s ao ao o

d 4

3 2

s o

t n

D A A

o~

e C

E t

g C EP EG co y,cO *vu4 e

P DG GE x

L G E E

A-5 0

A

/5 0

/

7o v

2 TLP S

R

. m_,

,s -

- '3 h

s

. NI ;

,e

,(,})

h 6

f.:

t b

t t

CASE 6 I

I CONTROL BUILDING SURFACE FOUNDATION VS. DESIGN r

P-

. UNIT 2 GROUND MOTION o

s.

I i

el' t

t i-e

~~

~ ' T TTE_'_ _____.__________

i B

C.

E OC TLP 0

n 1

ao ri g

tt n2 n cc i c o ee p ei pr m st Si a/ o D

D t M n

f gN d

i-5 n3 sE 2 c e

t i

D f -

a sF

)

n Ct r-aoe Pf ri e G

t t r 2

c aF h1 e r t1 0

p e2 i

\\

q 1

s sl wv

\\

\\

e et e

~

t l ci s3

\\

'g N

A A U s(

o l c n eE h

)

J z

y H

li a

d

(

n

\\'

s' At y

us c

n y

Ii

\\i n

So s'\\

ue SP I

/

q ns I

e ds i ' / [/

r Fa M

F e

2 a3 c

/

0 f,r 1

f rt ui Sn f

U E

Gg En J

s s

i r

r nt nt m

e e

fd u gi gi ol i

t irir nu c sese oB eUpUp s

p o

o il S sr sr ro iP iP ar n s s

pt g yl yl mn i li li oo 1

s aoao e nS nS CC 0

d c.

0 0

0 o.

w C.

n DA A

0 1

00 5

0 5

o s

e C

E s

g C EPED 13 2

2 C3echmO84 e

P GG GE X

L G E E

5 8/

5 0

/

7 0V 2TL PS R

1!

l

0 1

g n2 n i c o p ei mst a/ o D t M f

d 5 nl

$ e t

i

~

s ~~

asFn aoe ri e t t r c aF

~

e r p e2

\\

~

0
sl s

1 s

5

~

e et

\\

-\\

t l ci

\\

s o

l c n r

T A

N A A U

/

)

s z

H

/

(

s r4 r\\

y

\\sA cna u

P n

/.

t, e

I 1 '. j r

F l/

d

/

0 M

1

0 p

'~-

/., '-

r nt nt s

s m

e e

u gi gi t irir c se se eUpUp p

o o

S sr sr iP iP n s s

g yl yl i l l li

s ao ao 0

d e nS nS 0

4 3

a_

c.

n D A A

2 1

e C

E 0

g C EP EG 1

Co eel 0teuod e P GG GE r

X L G E E

fI

0 1

g n2 n i c o p ei m st 1

a/ o D t M f

5 nl d

a e t

i s

a sF n

4 a o e N

~

ri e

~

t t r Y-c aF e r s

0 p e2

\\

1 s sl

\\

e et

\\

R

\\

t l c i

\\

~

o l c n

/

N A A U l

s H

z

(

/

\\

s%

y

\\A cn

\\

e u

f, p

q e

j/

r

'l

/f F

v9 e

/1-

0 1

s#-'

/-

s s

m e

e u gi gi r nt nt t irir p

o o

c sese eUpUp S sr sr iP iP n s s

D yl yl i li li s ao ao

e nS nS 0

d

+

Y.

a.

c. 1 n D A A

f 5,

e C

E 0

g C EP EG 1

CO A v mbme8d e P DG GE

~

X L G E E

~

=

0 1

g n2 n i c o p ei m s t a/ o D t M f

s 7

d 5 n3a c N

t i

M.

asF

/.

n a o e r i e x

t t r c aF

\\

u

/

\\

e r r,

\\

. 0 p e2

(

s sl t

\\

,\\

1

\\

\\

e et

\\

i t

l c i

\\

\\

\\

o l c n 1

\\

N A A U

\\

\\

\\

)

t z

r H

T

(

)

n*

6 y

s 4L c

neu lt f, '

q

.s e

i'I I

I r

_ l F

l

}

t*I

}lI D

/

/ll 0

I 0

'pJ 1

//' )'

l j

e s

s

)

m e

e u gi gi

/

/.

r nt nt t irir c sese

/

p o

o eUpUp S sr sr i P ip n s s

g yl yl i l l li

s ao ao 0

d e nS nS C.

0 0

0 0

0 0

e, 1 n D A A

e C

E 05 4

2 0

e 5

2 g C EP EG g+

  • obm8o4 11 1

1 e P DG GE X

L G E E

0

'1 g

n2 n i c o p e i m s t O t M a/ o f

d 5 n3

~

i c t

i asFn aoe

/ -

r i e t t r c aF

~

V

~

I e r O

p e 2 4'

L s sl

\\

\\

e e t t

l ci

\\

o l c n

\\

{

N A A U h

O

)z H

/

(

h

/

gL y

s t

cn

~ 3 eu

'1t#h q

/

e s,a

/

r j

F

/

/

vl i

j '/

00 j'

2 4,

s s

m e

e u gi gi r nt nt t irir c sese eUpUp p

o o

S sr sr iP ip n s s

Q yl yl i li li

s ao ao 0

d e nS nS A

3 2

C.

n D A A

1 e

C E

0 g C EP ED E e e((i g o u4 e P DGGE 1

L G E E

X

0 1

g n2 n i c o p e i m s t a/ o D t M f

K d

S nl

$ e u

t i

a sF

.\\

d n

a o e ri e

~

t t r n

c aF e r y

0 p e 2

\\

1

sl s

I

\\

~'

e e t

)

\\

t l ci I

o l c n

\\

f

/

N A A U

)

z J

H j/j

\\

(

1

.I l){ r c

y n

n e

[\\

q u

c

\\

t'

'I

/

e l g}

j r

F i

l, a

0

/

1

/s t

t s'y' s

s m

e e

u gi gi r nt nt s'

t irir c sese eUpUp p

o o

S sr sr i P iP n s s

g yl yl i li li s ao ao

e nS nS 0

d 1

e.

0 n D A A

+

1 1

e C

E 0

g C EP EG 1

Co vE*E8#

e P DGGE X

L GE E

c OBSERVATIONS AND CONCLUSIONS FOR THE CONTROL BUILDING i

CASE 5 SURFACE FIND / UNIT 1 GROUND MOTION e SUBSTANTIAL CONSERVATISM EXISTS IN DESIGN RESPONSE DUE TO SSI/STRUCTUP.E ANALYSIS PROCEDURES e IN GENERAL, BOTH SOIL PROFILES SHOW CONSERVATISM. HOWEVER, LOW FREQUENCY RESPONSE FOR THE SOFT PROFILE SHOWS SOME EXCEEDANCES CASE 6 SURFACE FND/ UNIT 2 GROUND MOTION i

  • SPECTRAL PEAK ACCELERATIONS ARE LESS THAN DESIGN RESPONSE

{

  • SOME LOW FREQUENCY EXCEEDANCES OCCUR FOR I

BOTH SOIL PROFILES g

l k

1 l

t

(

TK R y

~=u

~

Q.,

p' NEXT STEPS

~

e SUPPLEMENT EXISTING COMPARISONS WITH UNIT 2 DESIGN RESULTS l

e COMPLETE SIMILAR ANALYSES FOR THE DIESEL GENERATOR BUILDING AND THE INTAKE

(

STRUCTURE

  • NRC TO PROVIDE SITE SPECIFIC GROUND MOTION DEFINITION FOR UNIT 1 EVALUATION l

e PERFORM EVALUATION OF REACTOR BUILDING, CONTROL BUILDING, DIESEL GENERATOR BUILDING, AND INTAKE STRUCTURE FOR NRC SPECIFIED SITE SPECIFIC SPECTRA e DOCUMENT RESULTS AND CONCLUSIONS i

l l

e

, x. _,