Amends 137 & 128 to Licenses DPR-42 & DPR-60,respectively, Revising TSs for Plant,Units 1 & 2 to Allow Use of Alternate SG Tube Repair Criteria in Tubesheet Region When Used with Repair Method of Addl Roll Expansion
ML20237D645
Person / Time
Site: Prairie Island  
(DPR-42-A-137, DPR-60-A-128)
Issue date: 08/13/1998
From: Kim T
NRC (Affiliation Not Assigned)
To:
Shared Package
ML20237D648 List:
References
NUDOCS 9808270106
Download: ML20237D645 (22)


Text

_ _ _ _ _ _ _ - _ _ _ - - _

l f

usu

'~

g 4

UNITED STATES g

j NUCLEAR REGULATORY COMMISSION o

WASHINGTON, D.C. 20666-0001 NORTHERN STATES POWER COMPANY DOCKET NO. 50-282 PRAIRIE ISLAND NUCLEAR GENERATING PLANT. UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE l

l Amendment No.

137 l

License No. DPR-42

]

1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Northern States Power Company (the licensee) dated September 24,1996, as supplemented October 17,1996, i

January 3, January 20, and November 10,1997, and January 9, June 8, and July 20,1998, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I;

)

l B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-42 is hereby amended to read as follows:

1 l

1 l

l l

l 9808270106 980813 PDR ADOCK 05000202 P

PDR f

)

e

\\

t-l l Technical Specifications l

The Technical Specifications contained in Appendix A, as revised through Amendment No. 137

, are hereby incorporated in the license. The licensee I

shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of issuance, with full implementation within 30 days.

)

l FOR THE NUCLEAR REGULATORY COMMISSION l

(2<

Tae Kim, Senior Project Manager Project Directorate 111-1 Division of Reactor Projects -lil/IV l

Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of issuance: August 13, 1998 l

l

l u

ATTACHMENT TO LICENSE AMENDMENT NO.137 FACILITY OPERATING LICENSE NO. DPR-42 DOCKET NO. 50-282 Revise Appendix A Technical Specifications by removing the pages identified below and inserting the attached pages. The revised pages are identified by amendment number and contain vertical lines indicating the area of change.

REMOVE INSERT TS.4.12-2 TS.4.12-2 TS.4.12-4 TS.4.12-4

' TS.4.12-5 TS.4.12-5 TS.4.12-6 TS.4.12-6 TS.4.12-7 TS.4.12-7 Table TS.4.12-1 Table TS.4.12-1 B.4.12-2 B.4.12-2 B.4.12-3 B.4.12-3 1

.l I

TS.4.12-2 v

2.

The first sample of tubes selected for each in-service inspection (subsequent to the preservice inspection) of each steam generator shall include:

(a) All tubes that previously had detectable wall penetrations

(>20%) that have not been plugged or sleeve repaired in the affected area.

(b) Tubes in those areas where experience has indicated potential problems.

(c) A tube inspection (pursuant to Specification 4.12.D.1.(h))

shall be performed on each selected tube.

If any selected tube does not permit the passage of the eddy current probe for a tube inspection, this shall be recorded and an adjacent tube shall be selected and subjected to a tube inspection.

3.

In addition to the sample required in Specification 4.12.B.2.a through c. all tubes which have had the F* or EF* criteria applied will be inspected in the F* and EF* regions of the roll expanded region. The region of these tubes below the F* and EF*

regions may be excluded from the requirements of 4.12.B.2.a.

4.

The tubes selected as the second and third samples (if required by Tables TS.4.12-1 or TS.4.12-2) during each inservice inspection may be subjected to a partial tube or sleeve inspection provided:

(a) The tubes selected for these samples include the tubes from those areas of the tube sheet array where tubes with imperfections were previously found.

(b) The inspections include those portions of the tubes or sleeves where imperfections were previously found.

The results of each sample inspection shall be classified into one of the following three categories:

Category Inspection Results C-1 Less than 5% of the total tubes inspected are degraded tubes and none of the inspected tubes are defective.

C-2 One or more tubes. but not more than 1% of the total tubes inseected are defective, or between 5% and 10%

L of the total tubes inspected are degraded tubes.

C-3 More than 10% of the total tubes inspected are degraded tubes or more than 1% of the inspected tubes are defective.

Note: In all inspections, previously degraded tubes must exhibit significant (>10%) further wall penetrations to be included in the above percentage calculations.

Prairie Island Unit 1 Amendment No. 118,132,137 Prairie Island Unit 2 Amendment No. fff, 124, 128 i

+'

TS.4.12-4 D.

Accentance Criteria 1.

As used in this Specification:

(a)

Imperfection means an exception to the dimensions, finish or contour of a tube from that required by fabrication drawings or specifications. Eddy-current testing indications below 20% of the nominal tube wall thickness, if detectable, may be considered as imperfections.

(b)

Degradation means a service-induced cracking, wastage, wear or general corrosion occurring on either inside or outside of a tube.

(c)

Derraded Tube means a tube containing imperfections 2 20% of the nominal wall thickness caused by degradation.

(d)

% Degradation means the percentage of the tube wall thickness affected or removed by degradation.

(e)

Defect means an imperfection of such severity that it exceeds the repair limit. A tube containing a defect is defective.

(f)

Renair Lim 4t means the imperfection depth at or beyond which the tube shall be removed from service by plugging or repaired by sleeving because it may become unserviceable prior to the next inspection and is equal to 50% of the nominal tube wall thickness.

If significant general tube thinning occurs, this criteria vill be reduced to 40% wall penetration. This definition does not apply to the portion of the tube in the tubesheet below the F* or EF* distance provided the tube is not degraded (i.e., no indications of cracks) within the F* or EF*

distance for F' or EF* tubes. The repair limit for the pressure boundary region of any sleeve is 31% of the nominal sleeve wall thickness. This definition does not apply to tube support plate intersections for which the voltage-based repair criteria are being applied. Refer to Specification 4.12.D.4 for the repair limit applicable to these intersections.

(g)

Unserviceable describes the condition of a tube if it leaks or contains a defect large enough to affect its structural integrity in the event of an Operating Basis Earthquake, a loss-of-coolant accident, or a steam line or feedwater line break.

l (h)

Tube Inseeetion means an inspection of the steam generator tube from the point of entry (hot leg side) completely around the U-bend to the too sunoort of the cold leg.

(i)

Sleevine is the repair of degraded tube regions using a new Alloy 690 tuting sleeve inserted inside the parent tube and sealed at each end by welding or by replacing the lower veld in a full depth tubesheet sleeve with a hard rolled joint. The new sleeve becomes the pressure boundary spanning the original degraded tube region.

Prairie Island Unit.1 Amendment No. f32, f21,137 Prairie Island Unit 2 Amendment No. 12#, 125, 128

TS.4.12-5 s

(j)

F* Distance is the distance from the bottom of the hardroll transition toward the bottom of the tubesheet that has been conservatively determined to be 1.07 inches (not including eddy current uncertainty). The F* distance applies to roll expanded regions below the midplane of the tubesheet.

(k)

F* Tube is a tube with degradation, below the F* distance.

equal to or greater than 40%, and not degraded (i.e., no indications of cracking) within the F* distance.

(1)

EF* Distance is the distance from the bottom of the upper hardroll transition toward the bottom of the tubesheet that has been conservatively determined to be 1.62 inches (not including eddy current uncertainty).

EF* distance applies to roll expanded regions when the top of the additional roll expansion is 2.0 inches or greater down from the top of the tubesheet.

(m)

EF* Tube is a tube with degradation, below the EF* distance, equal to or greater than 40%, and not degraded (i.e., no indications of cracking) within the EF" distance.

2.

The steam generator shall be determined OPERABLE after completing the corresponding actions (plug or repair by sleeving all tubes exceeding the repair limit and all tubes containing through-wall cracks or classify as F* or EF* tubes) required by Tables TS.4.12-1 and l

TS.4.12-2.

l 3.

Tube repair, after October 1, 1997, using Combustion Engineering welded sleeves shall be in accordance with the methods described in the following:

i l

CEN-629-P, Revision 2. " Repair of Westinghouse Series 44 and 51 Steam Generator Tubes Using Leak Tight Sleeves":

CEN-629 P, Addendum 1 Revision 1. " Repair of Westinghouse Series 44 and $1-Steam Generator Tubes Using Leak Tight Sleeves" 4.

Tube Suenort Plate Renair Limit is used for the disposition of a steam generator tube for continued service that is experiencing.

predominantly axially oriented outside diameter stress corrosion cracking confined within the thickness of the tube support plates.

At tube support plate intersections, the repair li'it is based on a

maintaining steam generator serviceability as described below:

a. Steam generator tubes, whose degradation is attributed to outside diameter stress corrosion cracking within the bounds of the tube support plate with bobbin voltages less than or equal to 2.0 volts j

will be allowed to remain in service.

b. Steam generator tubes, whose degradation is attributed to outside diameter stress corrosion cracking within the bounds of the tube support plate with a bobbin voltage greater than 2.0 volts, will be repaired or plugged, except as noted in Specification 4.12.D.4.c below.

Prairie Island Unit 1 Amendment NO. f 32,133,137 l

Prairie Island Unit 2 Amendment NO. 12#, 125, 128 j

)

TS.4.12-6 l'

Steam generator tubes. with indications of potential degradation c.

l attributed to outside diameter stress corrosion cracking within the bounds of the tube support plate with a bobbin voltage greater than 2.0 volts but less than or equal to the upper voltage repair limit, may remain in service if a rotating pancake coil (or comparable examination technique) inspection does not detect degradation.

Steam generator tubes. with indications of outside l

diameter stress corrosion cracking degradation with a bobbin voltage greater than the upper voltage repair limit will be l

plugged or repaired.

l

d. If an unscheduled mid-cycle inspection is performed, the following l

mid-cycle repair limits apply instead of the limits in Specifications 4.12.D.4.a. b and c.

The mid-cycle repair limits are determined from the following equations:

i V :n

~-

m

' CL - h t *

1. 0 + NDE + Gr CL g

V

= V,u - (V

- 2. 0) CL - h t*

1

}

an m

CL 1

I where:

Vuu = upper voltage repair limit Vuu. = lower voltage repair limit Van = mid-cycle upper voltage repair limit based on time into cycle Van = mid-cycle lower voltage repair limit based on Ven and time into cycle At = length of time since last scheduled inspection during which Vun and Vuu. were implemented CL = cycle length (time between two scheduled steam generator inspections)

Vn = structural limit voltage Gr = average growth rate per cycle length NDE = 95 percent cumulative probability allowance for l

nondestructive examination uncertainty (i.e., a value of j

20 percent has been approved by the NRC)

I Implementation of these mid-cycle rapair limits should follow the same approach as described in Specifications 4.12.D.4.a b and c.

l Note: The upper voltage repair limit is calculated according to the methodology in Generic Letter 95-05 as supplemented.

Prairie Island Unit 1 Amendment No. 133,137 Prairie Island Unit 2 Amendment No. 125, 128 l

l TS.4.12-7 1

E. Reeorts

1. Following each in-service inspection of steam generator tubes. if there are any tubes requiring plugging or sleeving, the number of tubes plugged or sleeved in each steam generator shall be reported to the Commission within 15 days.
2. The results of steam generator tube inservice inspections shall be included with the summary reports of ASME Code Section XI inspections submitted within 90 days of the end of each refueling outage. Results of steam generator tube inservice inspections not associated with a refueling outage shall be submitted within 90 days of the completion of the inspection. These reports shall include: (1) number and extent of tubes inspected. (2) location and percent of wall-thickness penetration for each indication of an imperfection and (3) identification of tubes plugged or sleeved.
3. Results of steam generator tube inspections which fall into Category C-3 require notification to the Commission prior to resumption of plant operation, and reporting as a special report to the Commission within 30 days.

This special report shall provide a description of investigations conducted to determine cause of the tube degradation and corrective measures taken to prevent recurrence.

4. The results of inspections performed under Specification 4.12.B for all tubes that have defects below the F* or EF* distance, and were not l

plugged. shall be reported to the Commission within 15 days following the inspection. The report shall include:

a.

Identification of F* and EF* tubes, and l

b.

Location and extent of degradation.

1

5. For implementation of the voltage-based repair criteria to tube support plate intersections, notify the NRC staff prior to returning the steam

]

generators to service should any of the following conditions arise:

a.

If estimated leakage based on the projected end-of-cycle (or if not practical, using the actual measured end-of-cycle) voltage distribution exceeds the leak limit (determined from the licensing basis dose calculation for the postulated main steamline break) for the next operating cycle, b.

If circumferential crack like indications are detected at the tube support plate intersections.

c.

If indications are identified that extend beyond the confines of the tube support plate.

[

d.

If indications are identified at the tube support plate elevations that are attributable to primary water stress corrosion cracking.

e.

If the calculated conditional burst probability based on the projected end-of-cycle (or if not practical, using the actual measured end-of-cycle) voltage distribution exceeds 1 x 10'*,

notify the NRC and provide an assessment of the safety significance of the occurrence.

Prairie Island Unit 1 Amendment No. f 32,133,137 Prairie Island Unit 2 Amendment No. 124, 125, 128

e fi d

v f

e i

n r

t of i

c i o u

e t

q f

ct N

e e

al O

R d

u I

ms T

n r

r e e C

o i s orl E

i e aef p

P t

A A npb r3 mA A

A A

S c

/

/ o e ue - a/

/

/

/

N A

N NNRt PC sN N

N N

I EL P

MA t

S lu D

s A

A 1 2 3

A A

A A

R e

/

/

/

/

/

/

3 R

N N

CC C

N N

N N

C C

nr s

ii n

N e

r rd a

o O

tb ot on s p

.i I

ecu f s f o e e t

T d

vet r

c b rs a C

e i p ni ne u

e c r

t sS of os tdbi E

P i

cn4 i

i nuf S

u ei G.

tf tf l ati 1

N q

f l

c o co l

t e

ed aS a

a a

eo I

2 N

R d nn t

t G. ivn 1

E O

aos ml ml t

I n

r ii r ue rue cS t tC B

4 U

T o

i sth osl osl e

cpR T

C i

e aeit f ep e

f ep ph e mN S

E t

A n

pbd r rm n

rrm s cf o T

R P

c

/

o eud n e

a o

e a

naer o O

S A

N N Rt ai P3 s N

P2 s I edP t E

T N

I L

A B

R 3

A E

E s ol l -

T N

L re

.na aC ne n

h E

P er G. t or os G

M h a A

t t

S uia ii o s.

b t t

M S

l A

u e

i.

i.

E D

s A

1 2

3 l G. 1 m2 d G. 3 d G.

T N

e

/

l

- o - d d

S 2

R N

C C

C ASCSC aSC AS d

n d

s i

d n n

e ni o

tb sra i

e cu ei s

t d

v et b as e.

a e

i p

u p e b G. ic t eb u r

t sS i

i c

n2 R utSf l

t i

G.

u e i q

f l

l,

S rt e

e d aS a

.e2 eo v

h n R

d nn G.i t aos t

t n

r ii cS t cotC o

i sth e

c e pR i

e a

eit ps eph mN t

n pbd sif s co c

o e ud n nh e nar o A

N Rt ai I tdi eP t N

t O

l I

u T

s 1

2 3

C e

E R

C C

C P

S f r N

oe I

p e

E z

m L

i u

P S

m s

M i

e A

e nbu S

l i

p mT T

m G.

S a

I S

ASS j

_ ~ - _ _ _ _ _ _ _ _ _ _ _

(

B.4.12-2 4.12 STZAM GEMPRATOR TUBE SURVEILLANCE Bases continued 0.025 inches will have adequate margins of safety against failure due to loads imposed by normal plant operation and design basis accidents (Reference 1).

Steam generator tube inspections of operating plants have demonstrated the capability to reliably detect vastage type defects that have penetrated 20% of the original 0.050-inch wall thickness (Reference 2).

Plugging or sleeving is not required for tubes meeting the F* or EF* criteria.

Due to the variable effect of tubeshcet bow with elevation, the F* criterion applies only below the tubesheet centerline and the EF* criterion is applied no higher than two inches down from the top of the tubesheet.

The F* and EF* distances will be controlled by a combination of eddy current l

inspection and/or process control. For a new additional roll expansion, the requirement will be at least 1.2 (1.8 inches for EF*) inches of new hard roll.

This is controlled by the 1.25 inch (two inches for EF*) effective length of the rollers.

The distance from the original roll transition zone is also controlled by the process in that the lower and of the new roll expansion is located one inch or greater above the original roll expansion.

In the case of l the new roll, eddy current examination will confirm there are no indications in the new roll region and that there is a new roll region with well defined upper and lower expansion transitions.

When eddy current examination, alone, must determine the F* or EF* distance.

l such as in the existing hard roll region, or when multiple lengths of additional hard rolls have been added, the addy current uncertainty is qualified by testing against known standards. That value is expected to be 0.18 inches. Therefore, the F* distance measured by addy current (sum of 1.07 and 0.18) will be conservatively set at 1.3 inches. The EF* distance measured by addy current (sum of 1.62 and 0.18) will be conservatively set at 1.9 inches.

q i

When more than one Alternate Repair Criteria are used, the summation of j

leakage from all tubes left in service by all repair criteria must be less than the allowable leakage for the most limiting of those Alternate Repair Criteria.

~

Whenever the results of any steam generator tubing in-service inspection fall into Category C-3, these results will be promptly reported to the Commission prior to resumption of plant operation.

Such cases will be considered by the

)

Commission on a case-by-case basis and may result in a requirement for

^

l analysis laboratory examinations, tests, additional eddy-current inspection, and revision of the Technical Specifications.if necessary.

Degraded steam generator tubes may be repaired by the installation of b

sleeves which span the section of degraded steam generator tubing. A steam generator tube with a sleeve installed meets the structural requirements of tubes which are not degraded.

The following sleeve designs have been found acceptable by the NRC Staff:

a. Westinghouse Mechanical Sleeves (WCAP 10757)
b. Westinghouse Brazed Sleeves (WCAP-10820)
c. Combustion Engineering Leak Tight Sleeves (CEN-294-P. for sleeves installed prior to October 1. 1997) i l

Prairie Island Unit 1 Amendment No. 132, 133, 137 Prairie Island Unit 2 Amendment No. 124, 125, 128

~

B.4.12-3 4.12 STEAM CENRRATOR TURE SURVEILLANCE Bases continued

d. Combustion Engineering Leak Tight Sleeves (CEN-629-P. for sleeves installed after October 1. 1997)

Descriptions of other future sleeve designs shall be submitted to the NRC for review and approval prior to their use in the repair of degraded steam generator tubes. The submittals related to other sleeve designs shall be made at least 90 days prior.to use.

Tube Sunnart Plate Renair L4m4t The voltage-based repair limits of Specification 4.12.D.4 implement the guidance in Generic Letter 95-05 and are applicable only to Westinghouse-designed steam generators with outside diameter stress corrosion cracking (ODSCC) located at the tube-to-tube support plate intersections. The l'

voltage-based repair limits are not applicable to other forms of steam generator tube degradation nor are they applicable to ODSCC that occurs at.

other locations within the steam generator. Additionally, the repair j

criteria apply only to indications where the degradation mechanism is l

dominantly axial ODSCC with no significant cracks extending outside the j

thickness of the support plate. Refer to Generic. Letter 95-05 for l

additional description of the degradation morrhology.

Implementation of Specification 4.12.D.4 requires a derivation of the l

voltage structural limit from the burst versus voltage empirical correlation and then the subsequent derivation of the voltage repair limit from the structural limit (which is then implemented by this surveillance).

The voltage structural limit is the voltage from the burst pressure / bobbin voltage correlation, at the 95 percent prediction interval curve reduced l

to account for the lower 95/95 percent tolerance bound for tubing material properties at 650*F (i.e., the 95 percent LTL curve). The voltage structural limit must be adjusted downward to account for potential flaw growth during an operating interval and to account for NDE uncertainty.

The upper voltage repair limit: Vma, is determined from the structural voltage limit by applying the following equation:

Ven, = Vn. - Vor Ves i

where Vor represents the allowance for flaw growth between inspections and

~

Vn represents the allowance for potential sources of error in the l

measurement of the bobbin coil voltage. Further discussion of the assumptions necessary to determine the voltage repair limit are discussed in Generic Letter 95-05.

The mid-cycle equation in Specification 4.12.D.4 should only be used during unplanned inspections in which eddy current data is acquired for indications at the tube support plates.

Prairie Island Unit 1 Amendment No. ff8, 133, 137 Prairie Island Unit 2 Amendment No. fff, 125, 128 I

4

=+a 4

~-

      • ew

p tuou p

UNITED STATES g

j NUCLEAR REGULATORY COMMISSION o

WASHINGTON, D.C. 30866 0001

<n NORTHERN STATES POWER COMPANY DOCKET NO. 50-306 PRAIRIE ISLAND NUCLEAR GENERATING PLANT. UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.128 License No. DPR-60 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Northern States Power Company (the licensee) dated September 24,1996, as supplemented October 17,1996, January 3, January 20, and November 10,1997, January 9, June 8, and July 20, 1998, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the l

Commission's regulations and all apphcable requirements have been satisfied.

l 2.

Accordingly, the license is amended by changes to the Technical Specifications as I

indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility i

Operating License No. DPR-60 is hereby amended to read as follows:

i

l *,

2-Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendment No. 128

, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of issuance, with full implementation within 30 days.

l i

i FOR THE NUCLEAR REGULATORY COMMISSION fcl-Tae Kim, Senior Project Manager Project Directorate ill-1 l

Division of Reactor Projects - lil/IV l

Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: August 13, 1998

~

ATTACHMENT TO LICENSE AMENDMENT NO.128 FACILITY OPERATING LICENSE NO. DPR-60 DOCKET NO. 50-306 Revise Appendix A Technical Specifications by removing the pages identified below and inserting the attached pages. The revised pages are identified by amendment number and contain vertical lines indicating the area of change.

REMOVE INSERT TS.4.12-2 TS.4.12-2 TS.4.12-4 TS.4.12-4 TS.4.12-5 TS.4.12-5 j

TS.4.12-6 TS.4.12-6 TS.4.12-7 TS.4.12-7 Table TS.4.12-1 Table TS.4.12-1 B.4.12-2 B.4.12-2 B.4.12-3 B.4.12-3 i

1 i

[

, 4 TS.4.13-2

+

2.

The first sample of tubes selected for each in-service inspection (subsequent to the preservice inspection) of each steam generator shall include:

(a) All tubes that previously had detectable wall penetrations

(>20%) that have not been plugged or sleeve repaired in the l

affected area.

(b) Tubes in those areas where experience has indicated potential problems.

(c) A tube inspection (pursuant to Specification 4.12.D.1.(h))

shall be performed on each selected tube.

If any selected tube does not permit the passage of the eddy current probe for a tube inspection, this shall be recorded and an adjacent tube shall be selected and subjected to a tube inspection.

3.

In addition to the sample required in Specification 4.12.B.2.a through c. all tubes which have had the F* or EF* criteria applied will be inspected in the F* and EF* regions of the roll expanded region. The region of these tubes below the F* and EF*

regions may be excluded from the requirements of 4.12.B.2.a.

4.

The tubes selected as the second and third samples (if required by Tables TS.4.12-1 or TS.4.12-2) during each inservice inspection may be subjected to a partial tube or sleeve inspection provided:

(a) The tubes selected for these samples include the tubes from those areas of the tube sheet array where tubes with imperfections were previously found.

(b) The inspections include those portions of the tties or sleeves where imperfections were previously found.

The results of each sample inspection shall be classified into one of the following three categories:

Category Inspection Results C-1 Less than 5% of the total tubes inspected are degraded tubes and none of the inspected tubes are defective.

C-2 One or more tubes. but not more than 1% of the total tubes inscected are defective, or between 5% and 10%

of the total tubes inspected are degraded tubes.

C-3 More than 10% of the total tubes inspecten are degraded tubes or more than 1% of the inspected tubes are defective.

l Note: In all inspections previously degraded tubes must exhibit significant (>10%) further wall penetrations to be included in the above percentage calculations.

Prairie Island Unit 1 Amendment No. 118,132,137 Prairie Island Unit 2 Amendment No. fif, 124, 128

4 TS.4.12-4 D.

Accentance Criteria 1.

As used in this Specification:

(a)

Imperfection means an exception to the dimensions, finish or contour of a tube from that required by fabrication drawings or specifications. Eddy-current testing indications below 20% of the nominal tube wall thickness, if detectable, may be i

considered as imperfections.

(b)

, Degradation means a service-induced cracking, wastage, wear or general corrosion occurring on either inside or outside of a tube.

(c)

Deeraded Tube means a tube containing imperfections k20% of the f

nominal wall thickness caused by degradation.

(d)

% Degradation means the percentage of the tube wall thickness affected or removed by degradation.

(e)

Defect means an imperfection of such severity that it exceeds the repair limit. A tube containing a defect is defective.

(f)

Reemir f_4m4t means the imperfection depth at or beyond which the tube shall be removed from service by plugging or repaired by sleeving because it may become unserviceable prior to the

]

next inspection and is equal to 50% of the nominal tube wall j

thickness.

If significant general tube thinning occurs, this I

criteria vill be reduced to 40% wall penetration. This definition does not apply to the portion of the tube in the tubasheet below the F* or EF* distance provided the tube is not degraded (i.e., no indications of cracks) within the F* or EP' distance for F* or EF* tubes. The repair limit for the pressure boundary region of any sleeve is 31% of the nominal sleeve wall thickness. This definition does not apply to tube support plate intersections for which the voltage-based repair criteria are being applied. Refer to Specification 4.12.D.4 for the repair limit applicable to these intersections.

(g)

Unserviceable describes the condition of a tube if it leaks or contains a defect large enough to affect its structural integrity in the event of an Operating Basis Earthquake, a loss-of-coolant accident. or a steam line or feedwater line break.

(h)

Tube Inseeetion means an inspection of the steam generator tube from the point of entry (hot leg side) completely around the U bend to the too succort of the cold len.

(i)

Sleav4ne is the repair of degraded tube regions using a new Alloy 690 tubing sleeve inserted inside the parent tube and sealed at each end by welding or by replacing the lower veld in a full depth tubesheet sleeve with a hard rolled joint. The new sleeve becomes the pressure. boundary spanning the original degraded tube region.

Prairie Island Unit'.1 Amendment No. f32, f31,137 Prairie Island Unit 2 Amendment No. TN, TU, 128 l

3

l 1

TS.4.12-5 (j)

F* Distance is the distance from the bottom of the hardroll transition toward the bottom of the tubesheet that has been conservatively determined to be 1.07 inches (not including eddy j

current uncertainty). The F* distance applies to roll expanded regions below the midplane of the tubesheet.

I (k)

F* Tube is a tube with degradation, below the F* distance.

l equal to or greater than 40%, and not degraded (i.e., ne i

indications of cracking) within the F* distance.

(1)

EF* Distance is the distance from the bottom of the upper hardroll transition toward the bottom of the tubasheet that has been conservatively determined to be 1.62 inches (not including eddy current uncertainty).

EF* distance applies to roll expanded regions when the top of the additional roll expansion is 2.0 inches or greater down from the top of the tubasheet.

(m)

EF* Tube is a tube with degradation, below the EF* distance, equal to or greater than 40%, and not degraded (i.e., no indications of cracking) within the EF* distance.

2.

The steam generator shall be determined OPERAELE after completing the corresponding actions (plug or repair by sleeving all tubes exceeding the repair limit and all tubes containing through-wall cracks or classify as F* or EF* tubes) required by Tables TS.4.12-1 and l

TS.4.12-2.

3.

Tube repair, after October 1. 1997. using Combustion Engineering welded sleeves shall be in accordance with the methods described in the following:

)

CEN-629-P. Revision 2. " Repair of Westinghouse Series 44 and 51 l

Steam Generator Tubes Using Leak Tight Sleeves":

CEN-629-P. Addendum 1. Revision 1. " Repair of Westinghouse Series 44 and 51 Steam Generator Tubes Using Leak Tight Sleeves" 4.

Tube Sunnert Plate Reemir L4m4t is used for the disposition of a steam generator tube for continued service that is experiencing predominantly axially oriented outside diameter stress corrosion cracking confined within the thickness of the tube support plates.

At tube support plate intersections, the repair limit is based on maintaining steam generator serviceability as described below:

a. Steam generator tubes, whose degradation is attributed to outside diameter stress corrosion cracking within the bounds of the tube support plate with bobbin voltages less than or equal to 2.0 volts vill be allowed to remain in service,
b. Steam generator tubes, whose degradation is attributed to outside diameter stress corrosion cracking within the bounds of the tube support plate with a bobbin voltage greater than 2.0 volts, will be repaired or plugged, except as noted in Specification 4.12.D.4.c below.

Prairie Island Unit 1 Amendment No. 132, 133, 137 Prairie Island Unit 2 Amendment No. 124, 125, 128 i

TS.4.12-6

+

Steam generator tubes. with indications of potential degradation c.

attributed to outside diameter stress corrosion cracking within the bounds of the tube support plate with a bobbin voltage greater than 2.0 volts but less than or equal to the upper voltage repair limit, may remain in service if a rotating pancake coil (or comparable examination technique) inspection does not detect degradation.

Steam generator tubes. with indications of outside diameter stress corrosion cracking degradation with a bobbin voltage greater than the upper voltage repair limit will be plugged or repaired.

d. If an unscheduled mid-cycle inspection is performed. the following mid-cycle repair limits apply instead of the limits in i

Specifications 4.12.D.4.a. b and c.

The mid-cycle repair limits

)

are determined from the following equations:

l l

V" V.y

=

m

_g

1. 0 + NDE + Gr CL s

V

=Vm - (V

- 2. 0) CL - ht*

yu CL where:

Vm = upper voltage repair limit Vm = lower voltage repair limit Vxuu. = mid-cycle upper voltage repair limit based on time into cycle

{

Vxuu. - mid-cycle lower voltage repair limit based on Vaun and time into cycle At = length of time since last scheduled inspection during j

which Vm and Vm were implemented l

1 CL = cycle length (time between two scheduled steam generator j

inspections)

Vn - structural limit voltage Gr = average growth rate per cycle length NDE = 95 percent cumulative probability allowance for l

nondestructive examination uncertainty (i.e.. a value of l

20 percent has been approved by the NRC)

Implementation of these mid-cycle repair limits should follow the same approach as described in Specifications 4.12.D.4.a. b and c.

l Note: The upper voltage repair limit is calculated according to l

the methodology in Generic Letter 95-05 as supplemented.

Prairie Island Unit 1 Amendment No. 133, 137 Prairie Island Unit 2 Amendment No. 125,128

l i

TS.4.12-7 E. Reports

1. Following each in-service inspection of steam generator tubes, if there are any tubes requiring plugging or sleeving, the number of tubes plugged or sleeved in each steam generator shall be reported to the Commission within 15 days.
2. The results of steam generator tube inservice inspections shall be l

included with the summary reports of ASME Code Section II inspections submitted within 90 days of the and of each refueling outage. Results of steam generator tube inservice inspections not associated with a refueling outage shall be submitted within 90 days of the completion of the inspection. These reports shall include: (1) number and estent of tubes inspected. (2) location and percent of wall-thickness penetration for each indication of an imperfection and (3) identification of tubes plugged or sleeved.

3. Results of steam generator tube inspections which fall into Category C-3 require notification to the Commission prior to resumption of plant operation, and reporting as a special report to the Commission within 30 days. This special report shall provide a description of investigations conducted to determine cause of the tube degradation and corrective measures taken to prevent recurrence.
4. The results of inspections performed under Specification 4.12.3 for all tubes that have defects below the F* or EF* distance, and were not l

plugged, shall be reported to the Commission within 15 days following the inspection. The report shall include:

a.

Identification of F* and EF* tubes, and l

b.

Location and extent of degradation.

5. For implementation of the voltage-based repair criteria to tube support plate intersections, notify the NRC staff prior to returning the steam generators to service should any of the following conditions arise:

l 1

l a.

If estimated leakage based on the projected end-of-cycle (or if not practical, using the actual measured end-of-cycle) voltage l

distribution exceeds the leak limit (determined from the licensing l

basis dose calculation for the postulated main steamline break)

I for the next operating cycle.

l l

b.

If circumferential crack-like indications are detected at the tube l-support plate intersections.

l c.

If indications are identified that extend beyond the confines of the tube support plate.

d.

If indications are identified at the tube support plate elevations that are attributable to primary water stress corrosion cracking.

e.'

If the calculated conditional burst probability based on the projected end of-cycle (or if not practical, using the actual measured end of-cycle) voltage distribution exceeds 1 x 10'*.

notify the NRC and provide an assessment of the safety

' significance of the occurrence.

Prairie Island Unit i Amendment No. 132, 133, 137 Frairie Island Unit 2 Amendment No. 124, 125, 128

or e

fi d

v f

e i

n r

t of i

c i o u

e t

q f

ct N

e e

al O

R d

u I

ms T

n r

r ee C

o i s orl E

i e aef p

P t

A A npb r3 mA A

A A

S c

/

/ oeue - a/

/

/

/

N A

N NNRt PC sN N

N N

I EL P

M A

t S

lu D

s A

A1 2 3

A A

A A

R e

/

/ - -

/

/

/

/

3 R

N NCC C

N N

N N

C C

nr s

ii n

N e

r rd a

o O

tb ot on s p

.i I

ecu f s f o ee t

T d

vet r

c b r sa C

e i p ni ne u

ec E

r t s5 of os tdbi P

i cn4 i

i nuf S

u ei G.

tf tf l ati 1

N q

f l

co co l

t I

e ed aS a

a a

eo 2

N R

d nn t

t G. ivn E

O aos ml ml t

1 B

I n

r ii rue rue cS ttC 4

U T

o i sth osl osl e

cpR T

C i

eaeit f ep e

f ep ph emN S

E t

A npbd rrm n

rrm s cf o T

R P

c

/

o eud n e

a o

e a

na er o O

S A

N NRt ai P3 s N

P2 s I edP t t

E T

N I

L A

B R

3 t

A E

E ol l -

s. n a aC T

N L

re ne n

h E

P er G. t or os t

G M

h a A

t t

S uia ii o s.

b t t

N S

l A

u e

i.

i i

E D

s A

1 2 3

l G.1 m 2 d G. 3 d G.

T N

e

/

l od

- d S

2 R

N CC C

ASCSC aS CAS d

n d

s i

d n n

e ni o

t tb sra i

ecu ei s

ta d

vet b ase e

i p u p e b G. ic t eb u r

t s5 R utSf i

i cn2.

i G.

u ei l

.t q

f l

5 rt l

e ed aS a. e2 eo v

h n R

d nn G.i t t aos t

n r

ii cS t cotC o

i sth e

ce pR i

e aeit psephmN t

n pbd sif s co c

o eud n nh enaro A

N Rt ai I tdi ePt N

t O

lu IT s

1 2

3 C

e E

R C

C C

P S

N f r oe I

p e

E z

m L

i u

P S

m h

se N

i W

b A

e n

u S

l i

p mT T

m G.

S a

I S

A5S

B.4.13-8 0

4.12 STEAM GENERATOR TUBE SURVEIL 7ANCE Bases continued 0.025 inches will have adequate margins of safety against failure due to loads imposed by normal plant operation and design basis accidents (Reference 1).

Steam generator tube inspections of operating plants have demonstrated the capability to reliably detect wastage type defects that have penetrated 20% of the original 0.050-inch wall thickness (Reference 2).

Plugging or sleeving is not required for tubes meeting the F* or EF* criteria.

-Due to the variable effect of tubesheet bow with elevation, the F* criterion applies only below the tubesheet centerline and the EF* criterion is applied no higher than two inches down from the top of the tubesheet.

The F* and EF* distances will be controlled by a combination of addy current l

inspection and/or process control. For a new additional roll expansion, the requirement will be at least 1.2 (1.8 inches for EF*) inches of new hard roll.

This is controlled by the 1.25 inch (two inches for EF*) effective length of the rollers. The distance from the original roll transition zone is also controlled by the process in that the lower and of the new roll expansion is located one inch or greater above the original roll expansion. In the case of l the new roll, eddy current examination will confirm there are no indications in the new roll region and that there is a new roll region with well defined upper and lower expansion transitions.

When eddy current examination, alone, must determine the F* or EF* distance.

l such as in the existing hard roll region, or when multiple lengths of additional hard rolls have been added, the eddy current uncertainty is

)

qualified by testing against known standards. That value is expected to be O.18 inches. Therefore, the F* distance measured by' eddy current (sum of 1.07 and 0.18) will be conservatively set at 1.3 inches. The EF* distance measured J

by addy current (sum of 1.62 and 0.18) will be conservatively set at 1.9 inches.

When more than one Alternate Repair Criteria are used, the summation of leakage from all tubes left in service by all repair criteria must be less than the allowable leakage for the most limiting of those Alternate Repair Criteria.

Whenever the results of any steam generator tubing in-service inspection fall l

into Category C-3, these results will be promptly reported to the Commission prior to resumption of plant operation. Such cases will be considered by the i

Commission on a case-by-case basis and may result in a requirement for analysis, laboratory examinations, tests, additional eddy-current inspection, and revision of the Technical Specifications if necessary.

Degraded steam generator tubes may be repaired by the installation of

?

sleeves which span the section of degraded steam generator tubing. A steam generator tube with a sleeve installed meets the structural requirements of tubes which are not degraded.

The following sleeve designs have been found acceptable by the NRC Staff:

a. Westinghouse Mechanical Sleeves (WCAP 10757)
b. Westinghouse Brazad Sleeves (WCAF-10820)
c. Combustion Engineering Leak Tight Sleeves (CEN-294-P for sleeves installed prior to October 1, 1997)

Prairie Island Unit 1 Amendment No. 132, 133, 137 Prairie Island Unit 2 Amendment No, 124, 125, 128

., ~ '

B.4.12-3

,e 4.12 STRAM GENERATOR TURE SURVEILLANCE r

Eases continued

d. Combustion Engineering Leak Tight sleeves (CEN-629-P. for sleeves installed after October 1. 1997) i Descriptions of other future sleeve designs shall be submitted to the NRC for review and approval prior to their use in the repair of degraded steam generator tubes. The submittals related to other sleeve designs shall be made at least 90 days prior,to use.

Tube Sunnert Plate Renair L4m4t The voltage-based repair limits of Specification 4.12.D.4 implement the guidance in Generic Letter 95-05 and are applicable only to Westinghouse-designed steam generators with outside diameter stress corrosion cracking (ODSCC) located at the tube-to-tube support plate intersections. The i

voltage-based repair limits are not applicable to other forms of steam generator tube degradation nor are they applicable to ODSCC that occurs at other locations within the steam generator. Additionally, the repair criteria apply only to indications where the degradation mechanism is dominantly axial ODSCC with no significant cracks extending outside the thickness of the support plate. Refer to Generic Letter 95-05 for additional description of the degradation morphology.

Implementation of Specification 4.12.D.4 requires a derivation of the voltage structural limit from the burst versus voltage empirical l

l correlation and then the subsequent derivation of the voltage repair limit I

from the structural limit (which is then implemented by this surveillance).

l The voltage structural limit is the voltage from the burst pressure / bobbin voltage correlation at the 95 percent prediction interval curve reduced to account for the lower 95/95 percent tolerance bound for tubing material properties at 650*F (i.e., the 95 percent LTL curve). The voltage structural limit must be adjusted downward to account for potential flaw growth during an operating interval and to account for NDE uncertainty.

The upper voltage repair limit: Vaa, is determined from the structural voltage limit by applying the following equation:

Vma = Vn. - Vor - Vms l

where Vor represents the allowance for flaw growth between inspections and l

Vms represents the allowance for potential sources of error in the measurement of the bobbin coil voltage. Further discussion of the assumptions necessary to determine the voltage repair limit are discussed i

in Generic Letter 95-05.

1 The mid-cycle equation in Specification 4.12.D.4 should only be used during unplanned inspections in which addy current data is acquired for indications at the tube support plates.

Prairie Island Unit 1 Amendnent No. ff8, f33,137 Prairie Island Unit 2 Amendment No. fif, 125,128