ML20237C742

From kanterella
Jump to navigation Jump to search

Informs That Requirement to Pay Fee Under 10CFR170 for Review of Pilot Plant Applications for Use of Risk Informed Inservice Insp Methodologies for Plant Has Been Waived
ML20237C742
Person / Time
Site: Arkansas Nuclear  Entergy icon.png
Issue date: 08/18/1998
From: Funches J
NRC OFFICE OF THE CONTROLLER
To: Hutchinson C
ENTERGY OPERATIONS, INC.
References
TAC-M99756, TAC-MA2023, NUDOCS 9808240100
Download: ML20237C742 (3)


Text

. _ _ _ _ _ __ _ _ - _ - - - - - - - - - - - - - - - - ~ ~ ~

pa nua

', ye t UNITED STATES E E NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001

          • f August 18, 1998 Mr. C. Randy Hutchinson Vice President, Operations ANO Entergy Operations, Inc.

1448 S. R. 333 Rusiel!ville, AR 72801

Dear Mr. Hutchinson:

This Wtter is to infonn you that the requirement to pay a f9e under 10 CFR Part 170 for the review ol your pilot plant applications for the use of Risk Informed inservice inspection (RI-ISI) methodologies for the Arkansas Nuclear Ore (ANO) Umt 1, RI-ISI submittal (TAC MA2023), and the ANO Unit 2 RI-ISI submittal (TAC M99756) has been waived. For the reasons stated below, exemptions from the 10 CFR Part 170 fees are granted in accordance with 10 CFR Part 170.11(b)(1).

The Nuclear Regulatory Commission (NRC) hts encouraged licensees to submit applications for the Rl-ISI pilot programs under one umbrella sponsoring organization, e.g., the Nuclear Energy instituie (NEI), for demonstrating risk-informed methodologies to be used for piping segment and piping structural element selection in systems scheduled for inservice inspections. To provide a permanent approach to RI-ISi, the staff intends to utilize the experience gained through the pilot plant applications m orrier to propose changes to 10 CFR 50.55a and related regulatcy guidance documents. The r,uclear industry has submitted two methodologies for implementing RI-!SI.

One melnodology has been jointly developed by the American Society of Mechanical Engineers (AS~ME) Research and Westinghouse Owaers Croup (WOG) and the other methodology is being sponsored by the Electric Power Research Institute (EPRI).

The application submitted by Entergy Operations, Inc., dated Septernber 30,1997, (M99756) utilized the EPRI RI-IS1 methodology, for which ANO Unit 2 is a pilot plant. The ASME Code Case N-560 provides the a:temate examination requirements for Class 1, Category B J piping welds. Code Case N-560 is applicable only to ASME Class 1 piping systems. The application submitted by Entergy CperafMos, Inc., on June 3,1998, (MA2023) utilizes the Code Case N-560 method for ANO Unit 1. The staff will review the EPRI methodology applied M ANO Unit 2 as well as the pilot applications of Code Case N-MO for Vermont Yankee and ANO Unit 1.

The development of the RI-ISI programs will provide guidance to power reactor licensees and the NRC staff on an acceptable approach for utilizing risk information to support plant-specific changes to the licensing basis for inservice inspection programs, The program has the potential s to optimize the use of NRC and industry resources while continuing to assure adequate protection of the public health and safety, \ 'g l

9908240100 980018 PDR ADOCK 05000313 G . PDR

____m

}

l Mr. C Randy Hutchinson l Based on the foregoing, I have determined that exemptions from the 10 CFR Part 170 fee L requirements for the review of the ANO Unit 2 pi'ot RI-ISI submittal dated September 30,1997, and l_ the ANO Unit 1 pilot Rl-lSI submittal dated June 3,1998, are appropriate. The exemptions are authorized by law and are granted in accordance with 10 CFR 170.11(b)(1).

The $16,179 paid to date for the review of the ANO Unit 2 submittal (TAC No. M99756) will be refunded. You should receive the refund in approximately 30 days. You have received an invoice dated July 20,1998, (RLO548-98) with costs for the review of the RI-ISIS (TACs M99756 and MA2023) for the time frame March 29,1998, through June 20,1998. The additional amount of $7,336 will also be refunded, if paid prior to receipt of this letter. ,

if you have any questions, please contact Ellen Poteat of my staff at 301-415-6392.

S$$ signed byJesse Funches Je*se L. Funches Chief Financial Of5cer Docket Nos. 50-313 and 50-368 cc: See next page DIST'RIBjJTION Docket File PDR PD4-1 r/f WReckley,NRR CHawes, NRR OGC ACRS TGwynn, RIV  !

EAdensam (EGA1) JHannon GBagchi,NRR GLainas,NRR BBoger,NRR BSheron

{

OCFO/DAF/LFARB r/f OCFO/DAF r/f  !

OCFO/DAF SF(AR-1.17)OCFO r/f LTremper, OCFO Invoice File RLO191-98 -$14,213.50 ,

SHudson, OFCO/RF LHerr, OFCO/RF NUDOC (ML-61) Invoice File RLO390-98 -$ 1,965 j Document Name: ARMA2023.LTR OFC PM/PD4-1 LA/PD4-1 PD/PD4-1 ADP ADT ODNRR ,,s.,

NAME WRecidey/vw CHawes JHannon BBoger BSheron SCollins ***"

DATE V/ n /98 G lh /98 (, /N98 1In /98 1/ 3/98 F/ u /98 COPY YES/NO YES/NO /NS/NO YES/NO YETNO YES/66)

=

o OFC ocro m / OCFO M / OCFO/DAF/ OGC OCFO/DAF DCFO CF LTAR8/LFS LFARS LFARB/LFS h NAME GJac DBD child JTurdici [ PR JF DATE k M /08 { / > /98 3/J98 $lh8 ////98 /\ 98 / 98 COPY hE8/NO YES/NO ,VE'$/NO YES#[O NO YES YES/h OFFICIAL RECORD COPY ~

g la

Mr. C. Randy Hutchinson j Entergy Operations, Inc. Arkansas Nuclear One, Units 1 & 2 cc:

Executive Vice President Vice President, Operations Support

& Chief Operating Officer Entergy Operations, Inc.

Entergy Operations, Inc. P. O. Box 31995 P. O. Box 31995 Jackson, MS 39286-1995 Jackson, MS 39286-1995 Wise, Carter, Child & Caraway Director, Division of Radiation P. O. Box 651 Control and Emergency Management Jackson, MS 39205 Arkansas Department of Health 4815 West Markham Street, Slot 30 Little Rock, AR 72205-3867 Winston & Strawn 1400 L Street, N.W.

Washington, DC 20005-3502 Manager, Rockville Nuclear Licensing Framatone Technologies 1700 Rockville Pike, Suite 525 Rockville, MD 20852 Senior Resident inspector U.S. Nuclear Regulatory Commission P. O. Box 310 London, AR 72847 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 County Judge of Pope County Pope County Courthouse Russellville, AR 72801 y

I i

i l

_ _ _ _ _ _ . - _ _ _ _ - _ - - _ - _ - _ - _ _ ~