f
f f, j
  • 4 s

.e

?

j il JOSEP11 M. FARLEY NUCIE/r PLANT i

UNIT 2

~

t.

NARRATIVE

SUMMARY

OF OPERATIOW f

a November, 1987

,3 The Cycle 5 - 6 refueling outage cordinued into the month of November.

The following major safety-related enintenance was perferued iri the mcoth of November:

l 1.

Eddy current examinations were completed on all non-plugged tubes in all three steam generators. The inspection covered the full length of tubes above row 2 and from the hot leg tube end to the cold leg of xow 2 tubes.

(All row I tubes are plugged.-) No tubes were repaired,109 tubes were plugged (?A - 13, 28 - 35, 2C - 61), and 91 tubes were designated F*.

2.

Shotpeening on the hot leg tube sheet of the steam genctators was completed.

t 3.

The containment integrated leak rate test ws performed l successfully.

4.

Environmental qualification urk was pedorrvd on the reactw,..I 3

head vents.

l 5.

The program of inspecting electrical splices that were insta.Uled utilizing methods not evaluated by design for environmental j,

qualification continued. These splices were re-terrainatal hi )

acconiance with approved design on a priority basis.

6.

Testing of motor-operated valves in response to Inspa: tion and Enforcement Bulletin 85-0.3 is in progress.

7.

Miscellaneous corrective and prevcotIve maintenance was perforar.xl on the diesel generators.

(

Ij r

g e

l a

1 }.,,") L I 8712150391 871130 PDR AP9CK 05000364

/

R DCD 1,.

Wm

~

~

~ '

.. p,;. -

OPERATIN3 DATA REPORT

('

9 y

..a.

b i!

DOCKET NO.

50-364

',, ' h, DATE 12/3/87 COMPLETED BY J. D. Woodard TELEPHONE (205)899-5156

+,

\\

,iG OPEdATING STNIUS

1;

//

Notes

1. Unit Naw!"

Joseph M. Farley - Unit 2 3.ReportingVerio7.h November, 1987

1) Cumulative data since 2,652 7-30-81, date of
3. Licenstr:1 Thernal Power (NWt):

)4. Nameplate Rating.(Gross MWe):

860 commercial operation

^

5. Design Electrical Rating (Net MWe): 829
6. Maximum Dependable Capacity (Gross MWe):

864.9 7., Maximum Dependable Capacity Det MWe):

824.1

8. If Changes Occur in Capacity Ratings (Items Number 3 Through77) Since Last Report,

'L Give Reasons:

N/A

(

~

N/A s

9. Power Level To Which Restricted, If Any (Net M4e):
10. Reasons For Restrictions, If Any:

N/A,,.

This Month Yr-to-Date Cumulative

e e,

ill. Hours In Reporting Pericd 720 8,016 55,561

.c, %2. Number Of' Hours Reactor W&s Critical 0.0 6,241.9 52,598.1 N 13. Reactor Peservo Shutdom Hours 0.0 0.0 138.0 l

. led Hours Generato:,Cn-Line 0.0 6,224.8 47,075.6 s

.1% thit AesetNe Shutdown Hours 0.0 0.0 0.0

16. Gross Thermal Energy Generated (MWH) 0 15,784,698 119,102,688
17. Grosa. Electrical Energy Ganerated (MWH) 44 5,127,114

~79,136,384

18. Mat Zlectrical Energy Generated (MWH)

-7770 4,853,584 37,102,696 0.0 77.7 84.7 i

19. Unit Service Factor 1

~

20.' Unit Availability Factora, 0.0 77.7 84.7

31. Unit Capacity Factor (Using'MDC Net)

-1.3~

73.5 81.9

22. Unit Capacity Factor (Using DE'R Not)

-1.3 73.0 80.6 i

23. Unit Forced Outage Rate'

~

'TT 5.7 4.6

24. Shutdowns Scheduled 09er Nkxt 6 Months (Type, tiate, and Duration of Each):

i N/A

25. If Shut Down At End Of Report. Period, EstEnated Date of Startup: December 4, 1987 1
26. Urlits In Test Status (Prior to Ccmmercilal Operation):

Forecast Achieved INITIAL CRITICALITY 05/06/81 05/08/81 INITIAL ELECTRICITY 05/24/81 05/25/81 00MMERCIAL OGERATION 08/01/81 07/30/81 l

t l

I Form 2/30 1

e i

L..

___.____._.____._______________J

l' DOCKET NO.

50-364 r

3-UNIT 2

.DATE December 3, 1987 COMPLETED BY J. D. Woodard' TELEPHONE' (205)899-5156 l

MONTH November' DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (PWe-Net)

(MWe-Net) 1-0 17 0

2 0

18 0

3 0 -'

19 0

4 0

20 0

5 0

21 0,

6 0

22 0

'7-0 23 0

8 0

24 0

9 0

25 0

10 0

26 0

11 0

27 0

12 0

28 0

13 0

29 0

14 0

30 0

15 0

31 16-0 INSTRUCTIONS on.this format, list the average daily unit power level in MWe-Net for each day in I

the reporting month. Compute to the nearest whole megawatt.

i Form 13/21

L 3 D 5 n

R O -

i A R O 9 t

F E W 9 n

4 B

1 c

8 o

6

. E D 5 M

3 M

C 5 J D J.

0 e

0

. E 2

g a

(

E E

t G

V C

u E

I N

o R

T E

U O E E Y E C

R g

e N N M T B N E O R n

e

(

A A O

R T U i

a s T N D D H R

C l

s t n e e

E E P O N E e

n a e l c

K T T E C O R u

o D ci r

C I E L I

f i

i F u

O N L E

& T T e

t f L o

D U P T C N r

c o

)

S M

E A E u

r R O

S V

6 r n o E e

C U

E

- 7 t o f L m

A R

5 8 s i

(

a C

P n t s t S

e 3 I

a t r l

- r e o c 0 G a e p I

y 1 p h e C

t e S R t

m i r i

e o b P yt

)

b h r i

r n 1 i

T f h r t e 6 h

x o n v 1 x

lll Il li i 1iI1IIiiIiIII II 1 I E f E E 0 E

T S

N N

E O

N I

O T

P E A

C M D

/

U O O N

D R

C C E

E R

B lll i ljiliIIi IIIiII II IIIIi M

R E

M E

V E

W O

T E O

N S D A

m)

P Y O

/

. r ia n S C N

D H

m c a N

T lll llliiI I I II Iii II!IIII Il a S l A

N r

p O

c c x S

M E

4 S i E N

E t

(

W T

S T

l l a O

R N T R D

O E N O A

d: a a m r u u o e T

P C E P

/

o n n t h U

E I V E N

h a a u t H

R L E R t M M A o S

e - - - -

T lll illliII IIIIiII IiI II IIi M 1 2 3 4 I

NU ROT F

C O G A n

N E 1

o D I R i

O T t

H T N a

T U W n

E H O i

M S D max l

l l

1 l

l ii II III I III I I I II I I i E

N

)

e O

n s

S i

n A

a e

E C

l c

R p

ni x

o L lll lllIi1II II I I I IIIII II I I E

i

(

t t &

s c

N e e i g r T r n O

)

u t i I S 0

T R l

r s n e A U 0

i o e i v E R O 2

a R a i U H 7

F e r t l c

yT a a p D

(

t n g r r

lll lll1 i 1 II II IIIl II II I i Il n a n o r t o e n i t o s i m e l a t i t

p t e l a n a r E

n i n u u r i r e P

o uif g e m e h Y

S s q a e e p d p t T

a E M R R oA O O e - - - - - -

lll llllIiIIIIIIIi I Ii II lIi R A B C D E F G 1

0 E

1 T

1 d

A 7

e D

8 l

d u l

ll l

lll l I I iI I II I i IIlII iII e d c e r h o c 7

F S lll lllli i Il IIII li I1iI III 1 O.

0 0

N F S

s' q

t. :

i l

j JOSEPH M. FARLEY NUCLEAR PLANT UNIT 2 NARRATIVE SUbNARY OF OPERATIONS November, 1987 j

The Cycle 5 - 6 refueling outage continued into the month of November.

l The following major safety-related maintenance was perfomed in the month of November:

1, Eddy current examinations were completed on all non-plugged tubes in all three steam genemtors. %e inspection covered the full length of tubes above row 2 and from the hot leg tube end to the cold leg of mw 2 tubes.

(All row 1 tubes are plugged.) No i

tubes were repaired, 109 tubes were plugged (2A - 13, 2B - 35, 2C - 61), and 91 tubes were designated F*.

2.

Shotpeening on the hot leg tube sheet of the steam generators was completed.

3.

%e containment integrated leak rate test was perfomed successfully.

4.

Environmental qualification work was perfomed on' the reactor head vents.

5.

The program of inspecting electrical splices that were installed utilizing methods not evaluated by design for environmental qualification continued. These splices were re-terminated in accordance with approved design on a priority basis.

6.

Testing of motor-operated valves in response to Inspection and Enforcement Bulletin 85-03 is in progress.

7.

Miscellaneous corrective and preventive maintenance was perfomed on the diesel generators.

I

W,,

OPERATING DNIA REPORT DOCKET NO.

50-364 DATI 12/3/87 CDIPIEI'ED BY J. D. Woodard TELEPH3E (205)899-5156

-OPERATING S'IEIUS Notes

1. Unit Name:

Joseph M. Farley - Unit 2

2. Reporting Period:

November, 1987

1) Cumulative data since
3. Licensed Thermal Power (MWt):

2,652 7-30-81, date of

4. Nameplate Rating (Gross MWe):

860 commercial operation

5. Design Electrical Rating (Net MWe): 829
6. Maximum Dependable Capacity (Gross MWe):

864.9

7. Maximum Dependable Capacity (Net MWe):

824.1

8. If Changes occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reasons:

N/A

9. Power Level To Which Restricted, If Any (Net MWe):

N/A

10. Reasons-For Restrictions, If Any:

N/A

'Ihis Month Yr-to-Date Cumulative

'l

11. Hours In Reporting Period 720 8,016 55,561
12. Number Of Hours Reactor Was Critical 0.0 6,241.9 52,598.1___
13. Reactor Reserve Shutdown Hours 0.0 0.0 138.0
14. Hours Generator On-Line 0.0 6,224.8 47,075.6
15. Unit Reserve Shutdown Hours 0.0 0.0 0.0
16. Gross Thermal Energy Generated (MWH) 0 15,784,698 119,102,688
17. Gross Electrical Energy Generated (MWH) 44 5,127,114 39,136,384
18. Net Electrical Energy Generated (MWH)

-7770 4,853,584 37,102,696

19. Unit Service Factor 0.0 77.7 84.7
20. Unit Availability Factor 0.0 77.7 84.7
21. Unit Capacity Factor (Using MDC Net)

-1.3 73.5 81.9

22. Unit Capacity Factor (Using DER Net)

-1.3 73.0 80.6

23. Unit Forced Outage Rate 0.0 5.7 4.6
24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

N/A

25. If Shut Down At End Of Report Period, Estimated Date of Startup: December 4, 1987
26. Units In Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY 05/06/81 05/08/81 INITIAL ELECTRICITY 05/24/81 05/25/81 COMMERCIAL OPERATION 08/01/81 07/30/81 rorm 2/30 l.

I L

..-m-DOCKET NO.

50-364 UNIT 2

DATE December 3, 1987 COMPLETED BY J. D. Woodard TELEPHONE (205)899-5156 MONTH November DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1 0

17 0

2 0

18

'O 3

0 19 0

4 0

20 0

5 0

21 0

6 0

22 0

7 0

23 0

8 0

24-0 9

0 25 0

10 0

26 0

11 0

27 0

12 0

28 0

13 0

29 0

14 0

30 0

15 0

31 16 0

INSTRUCTIONS on this format, list the average daily unit power level in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt.

l l

Form 13/21

ll 3

a

-,. j lll IllIIlIIIIIIIIIIIIIIII 2

T I

NU 7

8 9

1 D

6 d

T R

5 e

A 1

u E

L 3

D 5

n R

O i

A R

w]

9 t

9 n

F E

S o

4 B

3 M

E D

5) c M

6 C

0 e

0 E

2 g

a 5

J D

J

(

E E

t G

V C

u E

I N

o R

T E

U O E E Y E C

R g

e N N M T B N E O R n

e

(

A A O

R T U i

a s T N D D H R

C l

s t n e e

E E P O N E e

n a e l c

O N L E

& T T e

t f L o

. z K T T E C O R u

o D ci r

C I E L I

f i

i F u

D U P T C N r

c o

)

S M

E A E u

r R O

S V

6 r n oE e

C U

E

- 7 t o f L m

A R

5 8 s i

(

S a

C P

nt s t e3 I a t r l

- r e o c 0 G a e p I

y1 p h e C

t e S R t

m i r i

e o b P yt

)

b h r i

r n1 i

T f h r t e 6 h

x o n v 1 x

lll Ill IIiI IIIIIIII III III I E f E E 0 E

T S

N N

E O

N I

O T

P E A

C M D

/

t O O N

J D

R C C E

E R

B lll IllIIIII IIiI I IIIIIIIiI M

R E

M E

V E

W O

T E O

N S D A

m)

P Y O

/

a n D

H m.

r i S C N

c a A

N lll I llIIIIlIIlIIII1I 1IIl I a S l N

T r

p O

c c x S

M E

S S i E N

E t

(

W T

S T

l l a O

R N T R

a a m r D

O E N O A

d u u o e T

P C E P

/

o n n t h U

E I V E N

h a a u t H

R L E R t M M A O S

e - - - -

T lll Ill II 1Ii IIiIIIIiI iIIiI M 1 2 3 4 I

NU R

OT F

C O G A n

N E 1

o D I R i

O T t

H T N a

T U W n

E H O i

M S D maz lll I ll1I1IiIIl iII III I IIII F-N

)

e

)

O n

s n

S i

n i

A a

e a

E C

l c

l R

p ni p

x o L x

lll Ill1IlIIIIilIIIIIIIIlI E

i E

(

t t &

(

s c

N e e i g r

O

)

r T r n o

u t i r

)

I S 0

l r s n e r n T R A U 0

i o e i v E i R O 2

a R a i a

U H 7

F e r t l l c

yT a a p D

(

t n g r r n x lll Ill l IlIIIIIiIII IIIIIiI n a n o r t o (E

e ni t o s i m el a t i t

p t e l a n a r E

ni n u u r i r e P

o uif g e m e h Y

S s q a e e pd pt T

a E M R R O A O O e - - - - - - - -

lll IlllIlIIIIIIl IIIIII III R A B C D E F G H 1

0 E

1 T

1 d

A 7

e D

8 l

d u lll Il ll1lI III II I II I I III II e d c e r h o c 7

F S 7) 0 7

N F: :

/

O 0

5 9

(

lll 1lll1l1II IIII IIIIII III llllllllll

> (- '. ;..

.,,'.. T Alabama Power Compaity 600 North 18th Street.

{

Post O'l ce Box 2641 Birmingham. Alabama 35291-0400

. Telephone 205 250-1835 m

R. P. Mcdonald -

Senior Vice President AlabamaPower t?w southern electic system i

l December 9, 1987 q

l

\\

L Docket No. 50-364 U. S. Nuclear Regulatory Commission ATIN: Document Control Desk Washington, D. C.

20555 2

Joseph M. Farley Nuclear Plant Unit 2 Monthly Operating Data Report r

(

L j

Attached are two (2) copies of the November 1987 Monthly Operating Report-for Joseph M. Farley Nuclear Plant Unit 2, required by Section 6.9.1.10 of the Technical Specifications.

l If you have any questions, please advise.

Yours very ruly, i

%/

R. P. Mcdonald

.l RPN/JGS:mab Attachments l

l xc: Director, OE (10 copies)

Director, RII (1 copy) d t