ML20237A777

From kanterella
Jump to navigation Jump to search
Requests Addl Info Re 860106 Application Requesting Amend to Model BU-7 Package.Nrc Should Be Advised within 30 Days from Date of Ltr When Info Will Be Provided
ML20237A777
Person / Time
Site: 07109019
Issue date: 12/11/1987
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Winslow T
GENERAL ELECTRIC CO.
References
NUDOCS 8712150253
Download: ML20237A777 (2)


Text

(

fMG<

efer:,m 3QG-M DEC 11 1987 SGTB: RHO 71-9019 General Electric Company ATTN: Mr. T. P. Winslow P.0, Box 780 Wilmington, NC 28402 Gentlemen:

This refers to your application dated January 6,1986, as supplemented September 29, 1987, requesting an amendment to the Model No. BU.7 package.

In connection with our review, we need the information identified in the enclosure to this letter.

Please advise us within 30 days from the date of this letter when this information will be provided. Additional information requested by this letter should be submitted in the form of revised pages. If you have any questions regarding this matter, we would be pleased to meet with you and your staff.

Sincerely, Original Siccod by M SL.WClyCgag Charles E. MacDonald, Chief Transportation Branch Division of Safeguards and Transportation, NMSS

Enclosure:

As stated .

Distribution: w/ encl Docket File 'NRC PDR Region II DTHuang EPEaston CRMarotta RH0degaarden(2)

CEWilliams CRChappell 8712150253 871211 PDR ADOCK 07109019 NMSS R/F SGTB R/F C PDR

/ l 0FC: SGTB > g SG :SGTB g:SG}B :5GT,B :SGTB g :SGTB NAME:RH0. gaarde Huang:EPEaston:CRI1arota:CEbiliams: CRC ppell:CEMhcD id )

DATE:12/07/87 :12/o9/87:12/n /87:12/7 /87 :12h7/87 :12/4/87 :12/10r87 0FFICIAL RECORD COPY

(..

  • 1
  • \

l l

l l

GENERAL ELECTRIC COMPANY Model No. BU-7 Package Docket No. 71-9019 I

Encl to ltr dtd: DEC 111987 l

l Operating Procedures

1. The last item under Section 5.2.1 should be revised to explicitly exclude the gasket surface from the criteria accepting rust spots no larger than one square inch.
2. Should add a statement to Sectica 5.1.2 regarding gasket inspection and acceptance criteria.
3. The instruction under Section 5.1.4 should also state a maximum torque requirement to preclude failure due to over-torquing.
4. Section 5.1.4 shculd contain a statement indicating compliance with l 10 CFR Q71.89.

I h

i

- - - - - - - . _ . _ . - _ . .