Forwards ISI Rept Refueling Outage 12,Interval 2,Period 3, Outage 1 for Jm Farley Nuclear Plant. Summary of ISI Activities Performed During Refueling Outage Encl
ML20237A215
Person / Time
Site: Farley  Southern Nuclear icon.png
Issue date: 08/06/1998
From: Dennis Morey
SOUTHERN NUCLEAR OPERATING CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20237A217 List:
References
NUDOCS 9808130179
Download: ML20237A215 (5)


Text

_ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _

i Dave Morey SIuthern Nuclear Vice President Operati1g Compa;y Farley Project P0. Box 1295 Birmingham, Alabama 35201 Tel 205.992.5131 August 6, 1998 SOUTHERN h COMPANY I

Energy to Serve Your %rld" Docket Nos.:

50-348 10 CFR 50.55 I

50-364 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Joseph M. Farley Nuclear Plant

)

. Lnservice Insnection Renort Ladies and Gentlemen:

l Purruant to the requirements of 10 CFR 50.55a(g) and 10 CFR 50.36, Southern Nuclear Operating Company hereby submits the Farley Nuclear Plant Unit 2, Interval 2, Period 3, Outage 1 Inservice Inspection Report. This report (Enclosure 1) describes and summarizes the insersice inspection activities performed during the Unit 2 twelfth refueling outage. These activities were completed May 15,1998. Included in this report are the results of the steam generator eddy I

current testing conducted during this outage as required by 10 CFR 50.55a(g) and Section l

4.4.6.5.b of the Farley Nuclear Plant Unit 2 Technical Spaifications. A summary of these results 1

may be found in Tab B of Enclosure 1.

Other pertinent report information is available at Farley Nuclear Plant for your review. This information includes, as applicable, examination plans and schedules, examination results and reports, examination methods and procedures, evaluation results, and corrective action and repairs.

i Enclo.sure 2 contains a revision to a Unit 1 NIS-2 form (2 sheets) originally r:ubmitted by letter dated August 27,1997 as part of the Inservice Inspection Report for the Farley Unit I fourteenth refueling outage. This form should replace the one originally submitted.

j If there are any questions, please advise.

Respectfully submitted, b

Dave Morey h

l AJP:maf ist. doc Enclosures cc:

Mr. L. A. Reyes, Region 11 Administrator Mr. J. I. Zimmerman, NRR Project Manager I

I Mr. T. M. Ross, Plant Sr. Resident Inspector t

l m

T 9908130179 980806 I

PDR ADOCK 05000348 l

PDR e

t

l i

t ENCLOSURE 1 Insenice Inspection Repor*.

Farley Nuclear Plant Unit 2 - Tvalf& Refueling Outage l

l l

l kmm___..._

I I

i l

ENCLOSURE 2 NIS-2 Form Corrected Copy From Farley Nuclear Plant - Unit 1-Fourteenth Refueling Outage 4

i l

)

l

Form NIS-2 Owner's Report For Repairs Or Repl: cements As R quired By The Provisions of The ASME Code Section II RTyps L1.52 CORRECTED COPY Job Number corrected replacement serial number B13. WO96001728 Sheet 1

of 2 1.Owwr

2. Plant Unit Southern Nuclear Operating Company Farley Nuclear Plant 40 inverness Center Parkway Highway 95 South FNP 1 Birmingham, Alabama 35242 Columbia, AL 36319 Date (as agent for Alabama Power Company)

June :r, 1997

3. Work Performed By Type Code Synbot Stanp N/A Name Southern Nuclear Overstinr Comean, Maintenane, Decartment Authorization Nunber N/A Address Joserh M. Farlev Nuclear Plant Expiration Date N/A
6. Identification of System Reactor Coolant Systes 5.

(a) Applicable Construction Code ASME Section III

, 19 71 Edition Summer 71

Addenda, N/A Code Case (b) Applicable Section XI Utilised For Repairs Or Replacements 19 83 Edition Summer 83 Addenda.

N/A Code Case

6. Identification Of Conponents Repaired Or Replaced and Replacement Components:

N me Of Name Of Manuf acture r National Other Year Repaired ASME Code Component Manufacturer Serial No.

Board No.

Identification Built Replaced Or Stamped Replacement (Yes or No)

Sifsty Valve Crosby N56963-01-0004 N/A P.O. FMP2-2 1975 Replaced Yes Inlet Studs Crosby N90488 N/A P.O. FNP2 2 1975 Replaced Yes Inlet Nuts Crosby N90489 N/A P.O. FNP2-2 1975 Replaced Yes Safety Valve Crosby N56963-01-0012 N/A P.O. QP-3079 1989 Replacement Yes Ini t Studs Accutech Best Code B6 N/A P.O. QP961015 1996 Replacement No s

Inist Nuts Vitco Nuclear Best # 840238 N/A P.O. FNP2-2111 1979 Replacement No

7. Description Of Work Prescuriser safety volve Q1B13V0031A was removed and shipped offsite to be tested.

A spare valve was installed in its placs due to time constraints. Three new inlet studs and nuts were also installed. Ref: M1F's 97 038051 and 97 038588.

8. Tests Conducted

. Hydrostatic _ Pneumatic l Nominal Operating Pressure. None _ Other Pressure PSI Test Temp F.

F = 5ws ps

+

Form NIS-2 Owner's Report For Repairs Or Replacements RTypes Lt.52 Job NLsnber B13-V096001728 Sheet 2

of 2

9. Remarks ( Applicable Manuf acturer's Data Reports To Be Attached)

The replaced valve was installed under HWR 264031.

Certificate Of Compliance We certify that the statements made in the report are correct and this replacement conforms to the rules of the ASME Code,Section XI.

repair or replacement Type Cada Symbol Stamp N/A Certificate of Auth ri tion No.

N/A Expiration Date N/A Signed N

Cm-bA b_

Date I

.7 19 Owner or Owner's Designee, Title

/

Certificate Of Inservice Inspection I, the undersigned, holding a valia commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of 2,wa and Employed by _ff# e--w427" AbGl_ CIM b. of h/N4/A //Mc #rAWJB have inspected the compocents described in this Owner's Report during the period Mf5"/4 7 g/ff/9#

, and state that to to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising f rom or connected with this inspection.

h._

r.ommis sions M T 2$~

1 M spector's Signature National Board, State, Province, and Endorsements Dste 7/Z3 19 M r Form 5 3978 3/88