Safety Evaluation of TR-108685, BWR Vessel & Internals Project Instrument Penetration Insp & Flaw Evaluation Guidelines (BWRVIP-49). Rept Acceptable
ML20236Y329
Person / Time
Issue date: 08/04/1998
From:
NRC (Affiliation Not Assigned)
To:
Shared Package
ML20236Y314 List:
References
NUDOCS 9808120111
Download: ML20236Y329 (2)


Text

_ _ _ _ _ _ _ - _ _ _ _ __ _ _ _ __ _ - _ - __- _ - _ ____ _ _ _ _ _ ____- -_-_ ___ _____ - __

v

,?

U.S. NUCLEAR REGULATORY COMMIS$10N OFFICE OF NUCLEAR REACTOR REGULATION DIVISION OF ENGINEERING SAFETY EVALUATION OF EPRI TOPICAL REPORT TR-108695 "BWR VESSEL AND INTERNALS PROJECT.

INSTRUMENT PENETRATION INSPECTION AND FLAW EVALUATION GUIDELINES

)

(BWRVIP-49P 1.0 INTRODUcilON 1.1 Backorcund By letter dated March 13,1998, the Boiling Water Reactor Vessel and intemals Project (BWRVIP) submitted the Electric Power Research Institute (EPRI) Topical Report TR 108695, "BWR Vessel and Intemals Project, instrument Penetration inspection and Flaw Evaluation Gu delines (Ref.1), for staff review and approval. The BWRVIP intended, in submitting the BWRVIP-49 report, to provide proper inspection and evaluation procedures to ensure the long term integrity of instrument penetrations.

Instrument penetrations, consisting of penetrations, nozzles, and safe ends / extensions in a variety of configurations and materials, are used to allow measurement of reactor water level and maintain the reactor pressure boundary. The materials used are stainless steel, Alloy 600, j

Alloy 182 or 82, and low alloy steel (nozzles). The size of the instrument lines is under NPS 4 j

(4-inch pipe size).

l 1.2 Purpose The staff reviewed the BWRVIP-49 report to determine whether its guidance would ensure the long term integrity of instrument penetrations.

1.3 Organization of this Reoort Because the BWRVIP-49 report is proprietary, this SE was written so as not to repeat information contained in the report. The staff does not discuss in any detail the provisions of the guidelines nor the parts of the guidelines it finds acceptable.

2.0

SUMMARY

OF TOPICAL REPORT

. The BWRVIP-49 report addresses the following topics:

Instrument Penetration Assessment: Penetration function and configuration, susceptibility factors, consequences of cracking.

('

1 J

i 9908120111 990904 9

PDR TOPRP EXIEPRI C.

PDR

i 7

inspection and Evaluation Guidelines: Inspection history, inspection guidelines,

=

evaluation guidelines 3.0 STAFF EVALUATION The staff finds the BWRVIP-49 report and its guidance acceptable. The report addressed the degradation mechanisms of potential significance, it discussed the causes of crack initiation and growth, the susceptibility factors of environment, materials, and stress state, and the history of materials performance in this application. It discussed the consequences of failure, the monitoring used to detect failures, and measures prescribed to deal with the consequences.

Ref. 2 covered the safety consequences of failures.

One of the mechanisms which can cause degradation of the instrument penetrations is fatigue.

During the initial design process, the influence of fatigue on the penetrations was considered. In a majority of instances, the penetrations were determined to be exempt from the requirements of a detailed ASME Code Section ill fatigue analysis. In those instances where a fatigue analysis was required, the fatigue usage factors were determined to be very low, in addition, operational experience indicates that no unanticipated mechanisms exist which may accelerate degradation due to fatigue. Therefore, no additional guidance has been provided in this area.

4.0 CONCLUSION

S AND RECOMMENDATIONS The staff finds that the guidance presented should ensure the long term integrity of the instrument penetrations and thus provide an adequate level of quality and safety.

5.0 REFERENCES

1.

Electric Power Research Institute (EPRI) Topical Report TR-108695, "BWR Vessel and Internals Project, Instrument Penetration inspection and Flaw Evaluation Guidelines, March 13,1998.

j 2.

Electric Power Research Institute (EPRI) Topical Report TR 105707, "BWR Vessel and Intemals Project, " Safety Assessment of BWR Reactor Intemais," October 1995.

3.

NUREG-1557, Summary of Technical Information and Agreements from Nuclear Management and Resources Council Industry Reports Addressing License Renewal, October 1996.