PN-75-136:on 750906,lobster Samples Collected in Niantic Bay Exhibited Concentration of 0.42 Pci/G of Manganese 54 Which Greater than 10 Times Concentration Observed in Lobsters Collected at Control Station in Same Quarter
ML20236X090
Person / Time
Site: Millstone  Dominion icon.png
Issue date: 11/25/1975
From: Bidinger G, Jennifer Davis, Thornburg H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To:
References
PN-75-136, NUDOCS 9808070108
Download: ML20236X090 (1)


Text

_ _ _ _ _ - _ _ _ _ _ _ _ _ - - - -

1 l

.,1 l

PRELIMINARY NOTIFICATION - NOT FOR PUBLIC DISCLOSURE

~ I d U,4 November 25,1975 PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE

--PN-75-136

(.

This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public interest significance. The information presented is as initially received without verification or evaluation and is basically all that is known by OIE staff as of 8:00 a.m. on the date of this notification.

IT SHOULD BE SPECIFICALLY NOTED THAT THIS NOTIFICATION MAY CONTAIN INFORMATION THAT LATER MAY BE DETERMINED TO BE INACCURATE OR INCONSISTENT.

AN OFFICE OF INSPECTION AND ENFORCEMENT NOTIFICAITON OF AN INCIDENT OR OCCURRENCE (BLUE SHEET) SUBSEQUENTLY WILL BE ISSUED IF WARRANTED.

Tacility: Millstone Point 1 and 2 (DNs 50-245 and 50-336)

Northeast Nuclear Energy Company

Subject:

RADIOACTIVITY LEVELS IN THE ENVIRONMENT Lobster samples collected on 9/6/75 in Niantic Bay exhibited a concentration of 0.42 pCi/g of manganese 54 which is greater than 10 times the concentration (0.03 pC1/g) observed in lobsters collected at the control station in the same quarter.

=m This concentration is bracketed by values previously reported by the licensee in routine Environmental Reports.

However, due to the special reporting

  • ,("

requirements in Millstone-2's recently effective Environmental Technical Specifications, a formal Non-Routine Report is now required for this situation. Dose projections, assuming a person consumes 11 pounds of lobster meat per year, are 0.02 mrem to the gastrointestinal tract and 0.003 mrem to the whole body.

Media interest is expected because of previous coverage given this area.

The State of Connecticut has been and is being kept informed. A press release is not planned.

OIE received notification of this occurrence by letter from Northeast Nuclear Energy Company on November 21, 1975.

Contact:

GHBidinger x27261 HDThornburg x27353 JGDavis x27541 Distribution:

Chairman Anders Commissioner Mason S. J. Chilk, SECY Commissientir Gilinsky*

Commissioner Rowden G. F. Murphy, JCAI Commissioner Kennedy C. C. Ka= merer, CA

/

L. V. Gossick, EDO D. F. Knuth, IE J. A. Harris, PA E. C. Rusche, NRR J. La Fleur, ISP T. J. McTiernan, AIA K. R. Chapman, NMSS H. K. Shapar, ELD Transmitted: P BldgfMb; H St 9,Tc?g Lugeeno,/

(

- MNBB d//&%;

PRELIMINARY NOTIFICATION - NOT FOR PUBLIC DISCLOSURE 9808070108 751125 PDR I&E PN-75-136 PDR