ML20236W336

From kanterella
Jump to navigation Jump to search

Forwards SE Accepting 961217 & 970829 & 1006 Requests for Relief from Second 10-yr Interval ISI for Plant Units 1 & 2
ML20236W336
Person / Time
Site: Hatch  Southern Nuclear icon.png
Issue date: 07/30/1998
From: Berkow H
NRC (Affiliation Not Assigned)
To: Sumner H
SOUTHERN NUCLEAR OPERATING CO.
Shared Package
ML20236W339 List:
References
TAC-M99767, TAC-M99768, NUDOCS 9808050215
Download: ML20236W336 (3)


Text

July 30,1998

+-

Mr. H. L. Sumner, Jr.

Vice President - Nuclear

. Hatch Project Southern Nuclear Operating Company, Inc.

Post Office Box 1295 Birmingham, Alabama 35201-1295

SUBJECT:

SECOND 10-YEAR INTERVAL INSERVICE INSPECTION REQUESTS FOR z

RELIEF FOR EDWIN 1. HATCH NUCLEAR PLANT, UNITS 1 AND 2 (TAC NOS. M99767 AND M99768)

Dear Mr. Sumner:

By letters dated December 17,1996, and August 29 and October 6,1997, Southern Nuclear j

Operating Company, Inc., submitted requests for relief for the second 10-year interval inservice j

inspection for the Edwin 1. Hatch Nuclear Plant, Units 1 and 2.

I The NRC staff, with technical assistance from its contractor, the Idaho National Engineering and Environmental Laboratory (INEEL), has completed its review and evaluation of the informaiton provided in your submittals in support of relief requests.(RR) RR-2.1.3, Revision 1; RR-2.1.11; RR-2.1.12; RR-2.1.13; and RR-2.1.14. The staff finds the relief requests acceptable and has provided its evaluation and conclusions in the enclosed Safety Evaluation.

INEEL's Technical Letter Report is also enclosed.

Sincerely, ORIGINAL SIGNED BY:

Herbert N. Berkow, Director Project Directorate 11-2 i

Division of Reactor Projects - 1/II Office of Nuclear Reactor Regulation Docket Nos. 50-321 and 50-366

Enclosures:

As stated prmp to g nge 7 pogy sLng LLa h u a WWa e cc w/encls: See next page Distribution:

HBerkow OGC

/

Docket File LBerry ACRS I

PUBLIC LOlshan LPlisco, Rll PD ll-2 Rdg.

TMcLellan PSkinner, Ril QI JZwolinski e-mail TLH3 - SE only b

I To receive copy of document, Indicate: C= Copy w/o engh,1= Copy w/ enc! N=No copy OFFICj{ gym:PDil-2 l

LA:PDil9Hb OG9APVD:P qi NAME NLOlshan:en LBerry MY MM HBerRY DATE 7 /I498

<1/h /98 7 d I/98' i t,73 /98 p

DOCUMENT NAME: G:\\ HATCH \\ HAT 99767.RR i

OFFICIAL RECORD COPY-9808050215 980730 PDR ADOCK 05000321 G

PDR

g t

UNITED STATES NUCLEAR REGULATORY COMMISSION U

E WASHINGTON, D.C. *a= aaat

%,,,,,,/

July 30,1998 Mr. H. L. Sumner, Jr.

Vice President-Nuclear Hatch Project Southem Nuclear Operating Company, Inc.

Post Office Box 1295 Birmingham, Alabama 35201-1295

SUBJECT:

SECOND 10-YEAR INTERVAL INSERVICE INSPECTION REQUESTS FOR RELIEF FOR EDWIN 1. HATCH NUCLEAR PLANT, UNITS 1 AND 2 (TAC NOS. M99767 AND M99768)

Dear Mr. Sumner:

By letters dated December 17,1996, and August 29 and October 6,1997, Southem Nuclear Operating Company, Inc., submitted requests for relief for the second 10-year interval inservice inspection for the Edwin 1. Hatch Nuclear Plant, Units 1 and 2.

The NRC staff, with technical assistance from its contractor, the Idaho National Engineering and Environmental Laboratory (INEEL), has completed its review and evaluation of the informaiton provided in your submittals in support of relief requests (RR) RR-2.1.3, Revision 1; RR-2.1.11; RR-2.1.12; RR-2.1.13; and RR-2.1.14. The staff finds the proposed relief requests acceptable and has provided its evaluation and conclusions in the enclosed Safety Evaluation.

INEEL's Technical Letter Report is also enclosed.

Sincerely, b

$l-e bert N. Berkow, Director Project Directorate ll-2 Division of Reactor Projects - 1/11 Office of Nuclear Reactor Regulation Docket Nos. 50-321 and 50-366

Enclosures:

As stated cc w/encis: See next page l

\\

Edwin 1. Hatch Nuclear Plant 4

cc:

Charles A. Patrizia, Esquire Mr. Emest L. Blake, Jr.

Paul, Hastings, Janofsky & Walker Shaw, Pittman, Potts 10th Floor and Trowbndge 1299 Pennsylvania Avenue 2300 N Street, NW.

Washington, DC 20004-9500 Washington, DC 20037 Chairman Mr. D. M. Crowe Appling County Commissioners Manager, Licensing County Courthouse Southem Nuclear Operating Baxley, Georgia 31513 Company, Inc.

P. O. Box 1295 Mr. J. D. Woodard Birmingham, Alabama 35201-1295 Executive Vice President Southem Nuclear Operating Resident inspector Company, Inc.

Plant Hatch P. O. Box 1295 11030 Hatch Parkway N.

Birmingham, Alabama 35201-1295 Baxley, Georgia 31531 Mr. P. W. Wells Regional Administrator, Region ll General Manager, Edwin 1. Hatch U.S. Nuclear Regulatory Commission Nuclear Plant Atlanta Federal Center -

Southem Nuclear Operating 61 Forsyth Street, SW, Suite 23T85 Company, Inc.

Atlanta, Georgia 30303 U.S. Highway 1 North P. O. Box 2010 Mr. Charles H. Badger Baxley, Georgia 31515 Office of Planning and Budget Room 610 Mr. R. D. Barker 270 Washington Street, SW.

Program Manager Atlanta, Georgia 30334 Fossil & Nuclear Operations Oglethorpe Power Corporation Harold Reheis, Director 2100 East Exchange Place Department of Natural Resources P. O. Box 1349 205 Butler Street, SE., Suite 1252 Tucker, Georgia 30085-1349 Atlanta, Georgia 30334 Steven M. Jackson Senior Engineer-Power Supply Municipal Electric Authority of Georgia l

1470 Riveredge Parkway, NW Atlanta, Georgia 30328-4684 l

l t

!