1 o

l 1

DEC 0 31987 SGTB: RHO-71-9193-1 l

Nuclear. Energy Services, Inc.

ATTN: Mr. Paul Ely Shelter Rock Road Danbury, CT 06810 Gentlemen:

This refers to your application dated September 11,'1987, requesting an amendment to the Model No. NES-5. package.

In connection with our review, we need the information identified in.the enclosure to this letter.-

Please advise us within 30 days from the date of this letter when this information.will be provided. Additional information requested by this letter:

should be submitted in the form of revised pages.

If you have any questions regarding this matter, we would be pleased to meet with you.'and your staff.

Sincerely.-

Original Eisnod by (MANSE 8E. E m m 2n C'arles E. MacDonald, Chief h

Transportation Branch.

Division of Safeguards and Transportation. FMSS-

Enclosure:

As stated 1

Distribution: w/enci Docket File rNRC1PDR3 CRChappell Region I RH0degaarden(2)

CEWilliams NMSS R/F-SGTB R/F-

.j J

A i

SGTB SGTB
SGTB I

0FC:SGTB[.__...:,SGTB4 r.r;4----._g..g :

j

...... p.4.....

NAME:RH0degaarden:DTHuang :CEWilliams:CRChappell:CEMa onaTd:

i DATE:12/ol/87

/12/ol/87:12/o//87 :12/07/47
12/? /87 OFFICIAL RECORD COPY

~

i 0

8712040364 871203 PDR ADOCK 07109193 C.

PDR

-. _. - - _. -. ~ _. - - -.. _

__y.

l l

Nuclear Energy Services, Inc.

Model No. NES-5 Package-Docket No. 71-9193 Encl to ltr dtd: DEC 0 319871 l

l 1.

Provide drawings of the package without the proprietary markings.

1 2.

Correct Table 2.3-1 for the bolt ring.

3.

Correct the calculation on page 2-16 for the mounting plate. The weight j

of the lid was improperly considered in the calculation.

4.

Provide dimensions of the vertical leg of the tie-down ring for both the original and optional designs.

l

?

7 I

O -

1

___a