ML20236V318

From kanterella
Jump to navigation Jump to search
PN-75-085:vehicle,property of Insp Svc,Was Stolen Between 750902-03.Vehicle Contained an Automation Industries Camera Containing 14 Curies of Ir-192
ML20236V318
Person / Time
Issue date: 09/03/1975
From: Jennifer Davis, Dreher F, Thornburg H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To:
References
PN-75-085, PN-75-85, NUDOCS 9808030079
Download: ML20236V318 (1)


Text

- - - _ _ _ _ _ _ _ _ _ _ _ - _ - _ _ _ _ _ _ _ ___ _

3/Jj PRELIMINARY NOTIFICATION - NOT FOR PUBLIC DISCLOSURE September 3, 1975 PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE

--PN-75-85 This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public interest significance. The information presented is as initially received without verification or evaluation and is basically all that is known by OIE staff as of 11:00 a.m. on the date of this notification.

IT SHOULD BE SPECIFICALLY NOTED THAT THIS NOTIFICATION MAY CONTAIN INFORMATION THAT LATER MAY BE DETERMINED TO BE INACCURATE OR INCONSISTENT. AN OFFICE OF INSPECTION AND ENFORCEMENT

" NOTIFICATION OF AN INCIDENT OR OCCURRENCE (BLUE SHEET) SUBSEQUENTLY WILL BE ISSUED IF WARRANTED.

Facility:

Inspection Service Corporation Conshohocken, Pennsylvania

Subject:

STOLEN RADIOGRAPHY SOURCE A vehicle, property of Inspection Services, Conshohocken, Pennsylvania (an NRC licensee), parked at Feasterville, Pennsylvania, was stolen be-tween the hours of 11:00 p.m., 9/2/75 and 8:00 a.m., 9/3/75. The vehicle contained an Automation Industries camera containing 14. curies of Irid;fum-192. Lower Southhampton Police and the Philadelphia Office of the FBI ggg have been notified.

(

Media interest is. expected because of potentini hazard to the public.

The States of Pennsylvania and New Jersey have been and are being kept informed. A press release is planned Region I received notification of this occurrence by telephone from Incpection Services at 9:50 a.m., 9/3/75.

Contact:

FADreher, IE x 7261 HDThornburg, IE x 7353 JGDavis, IE x 7541 Distribution:

Chairman Anders Commissioner Mason S. J. Chilk, SECY Commissioner Gilinsky Commissioner Rowden G. F. Murphy, JCAE Commissioner Kennedy C. C. Kammerer, CA L. V. Gossick, EDO D. F. Knuth, IE J. A. Harris, PA B. C. Rusche, NRR H. H. Brown, ISP T. J. McTiernan, AIA K. R. Chapman, NMSS H. K. Shapar, ELD I

y Luge p {/ ~

Transmitted: P Bldg /.7.'o sy H St /d//f A; MNBB /d f.2dr. ;

i

)L. l-x kN PRELIMINARY NOTIFICATION - NOT FOR PUBLIC DISCLOSURE

\\-

g y

9808030079 750903 PDR I&E PN-75-085 PDR

.