ML20236V002

From kanterella
Jump to navigation Jump to search
PN-75-066:on 750807,203 Fuel Channel Boxes Have Been Examined for Excessive Corner Wear from Incore Monitoring Tube Vibration.Rejected 88 Based on Wear Mark or Path Estimated to Result in Wall Thickness Reduction of 1/2
ML20236V002
Person / Time
Site: Browns Ferry 
Issue date: 08/07/1975
From: Jennifer Davis, Gower G, Thornburg H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To:
References
PN-75-066, PN-75-66, NUDOCS 9807310235
Download: ML20236V002 (1)


Text

y v (_ a,l V o C LJp o

2 l 41) c PRELIMINARY NOTIFICATION - NOT FOR PUBLIC DISCLOSURE

(

August 7, 1975 PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE --PN-75-66 This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public interest significance. The information presented is as initially received without verification or evaluation and is basically all that is known by OIE staff as of 8:15 a.m.

on the date of this notification.

IT SHOULD BE SPECIFICALLY NOTED THAT THIS NOTIFICATION MAY CONTAIN INFORMATION THAT LATER MAY BE DETERMINED TO BE INACCURATE OR INCONSISTENT. AN OFFICE OF INSPECTION AND ENFORCEMENT NOTIFICATION OF AN INCIDENT OR OCCURRENCE (BLUE SHEET) SUBSEQUENTLY

~ * * ~ ~ ~

' WILL BE ISSUED IF WARRANTED.

l Facility: Browns Ferry 1 Tennessee Valley Authority

Subject:

FUEL CHANNEL WEAR ADJACENT TO INCORE MONITORING TUBES As of 7:00 AM this date, 203 fuel channel boxes have been eyamined for excessive corner wear from incore monitoring tube vibration.

Of those l

examined, 88 were rejected based on a wear mark or path which is estimated

{

to result in a wall thickness reduction of about or.e half.

One of the E

' channel boxes had a wear through opening resembling a crack along the corner edge of about 16 inches in length.

GE, who is participating in the inspection. considers the information developed from this examination to be proprietai'.

OIE (Region II) received the information regarding this matter from F. Cantrell, our inspector who was at the site, on August 5 and 6, ;,

1975. The inform'ation on the fuel channels was obtained from both TVA and GE employees.

Contact:

GCGower, 1E x7261 HDThornburg, IE x7353 JGDavis, IE x7541 l

Distribution :

l Chairman Anders Commissioner Mason S. J. Chilk, SECY Commissioner Gilinsky Commissioner Rowden G. F. Murphy, JCAE Commissioner Kennedy C. C. Kammerer, CA L. V. Gossick, EDO D. F. Knuth, IE J. A. Harris, PA B. C. Rusche, NRR H. H. Brown, ISP T. J. McTiernan, AIA K. R. Chapman, NMSS -

H. K. Shapar, ELD Transmitted: P Bldg etioe ; H St ec/g ; MNBB/o3 A ; Luge ;p,o, !

l i

PRELIMINARY NOTIFICATION - NOT FOR PUBLIC DISCLOSURE C!

l v

l 9807310235 750007 O

PDR I&E l

~_

PN-75-066 PDR

_