ff ( w) U z N m

. i (DI}

PRELIMINARY NOTIFICATION - NOT FOR PUBLIC DISCLOSURE May 16, 1975 g

f[If O,9 PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE

--PN-75-25

/

This preliminary ilotification constitutes EARLY notice of events of

_+

PO3SIBLE safety or public interest significance.

The information presented is as initially received without verification or evaluation and is basically all that is known by OIE staff as of 8:00 a.m. on date of this notification.

IT SHOULD BE SPECIFICALLY NOTED THAT THIS NOTIFICATION MAY CONTAIN INFORMATION THAT LATER MAY BE DETERMINED TO BE INACCURATE OR INCONSISTENT. AN OFFICE OF INSPECTION AND ENFORCEMENT NOTIFICATION OF AN INCIDENT OF OCCURRENCE (BLUE SHEET) SUBSEQUENTLY WILL BE ISSUED IF WARRANTED.

Facility:

Dresden Unit 3, Commonwealth Edison Company

Subject:

CRACKS IN FEEDWATER SPARGER The licensee informed the OIE inspector at the site that a scheduled viuual inspection of the Dresden 3 reactor vessel internals had disclosed cracks near velds in the feedwater spargers. The licensee intends to replace the feedwater sparger assemblies.

It is anticipated that the repair work will add approximately 2-3 weeks to the current refueling outage.

m Similar cracks have been found in the feedwater spargers at Dresden 2, Quad Cities Unit 2,,and Millstone 1.

The feedwater spargers are not safety

(

related.

The licensee will submit a report to the NRC concerning the cracks.

A press release is planned by both the licensee and the NRC. Local public interest is expected because of the press releases.

I

Contact:

RFWarnick, IE x7261 HDThornburg, IE x7353 JGDavis, IE x7541 Distribution :

Chairman Anders Commissioner Mason S. J. Chilk, SECY l

Commissioner Gilinsky Commissioner Rowden G. F. Murphy, JCAE Commissioner Kennedy C. C. Kammerer, CA T. J. McTiernan, AIA B. Buberman, PE I

L. V. Gossick, EDO D. F. Knuth, IE J. A. Harris, PA B. C. Rusche, NRR H. H. Brown, ISP K. R. Chapman, NMSS H. K, Shapar, ELD

.r -~

s Transmitted: P Bldg //WC A; H St //>

MD Bldg /.'/)

/

j i

0 1_

PRELIMINARY NOTIFICATION - NOT FOR PUBLIC DISCLOSURE k

9807300245 750516

~

PDR I&E PN-75-025 PDR L