RETURN TO' '396-55

~

dGENERAL NUCLEAR SYSTEMSc INC. -

7/-fc2/f A Chem-Nuclear Company p, g"

'k N

l November 18, 1987 o

I 611-0337-87 6-C g

NOV191S87 ) ?

RECGVED

-s e

w a ttci m J~

Il0V j 9 gO k 1'

1 oocxti cttRx /y Mr. Charles E. MacDonald, Chief

\\;

J ly u.s.nucta, Noproey h

romas j

Transportation Certification Branch oJ hll*2 \\

g

(

l Division of Fuel Cycle and Material Safety, Ess e

Sr U.S. Nuclear Regulatory Commission

'GT j

Washington, D.C.

20555

Dear Mr. MacDonald:

l

SUBJECT:

LICENSE APPLICATION FOR OAK RIDGE NATIONAL LABORATORY MODEL HFIR CASK

REFERENCE:

LETTER FROM R. T. ANDERSON (GNSI) TO C. MACDONALD (NRC) DATED 10/29/87 This letter supercedes in its entirety the referenced letter.

General Nuclear Systems, Inc. (GNSI), submits to the Nuclear Regulatory Commission (NRC) a license application for a spent fuel cask to be used by research reactors.

The U.S. Department of Energy (DOE) will have ownership of the cask and license, and the Certificate of Compliance will be issued to the 00E.

Enclosed is the initial submittal of the Safety Analysis Report describing the design of a reusable shipping package fabricated for transport of fissile Class I spent nuclear fuel, designated as the HFIR Cask. The shipping package consists of a welded stainless steel and lead cylindrical cask with bolted lid closure, changeable fuel baskets, and top and bottom impact limiters.

The SARP has been prepared in accordance with proposed Revision 2 to Regulatory Guide 7.9, Standard Format and Content of Part 71 Applications for Approval of Packaging for Radioactive Material.

The design, certification, and fabrication of the spent fuel cask has been contracted by the Oak Ridge National Laboratory to General Nuclear Systems, Inc. (GNSI).

Therefore, GNSI shall act as the prime contact with the NRC in this license application. All official correspondence on th h license application should be directed to:

Mr. Robert T. Anderson ector, Cask & hanspodadon hstem 8712010125 871,1,10,,,

General Nuclear Systems, Inc.

PDR ADOCK 071 C

PDR 220 Stoneridge Drive Columbia, South Carolina 29210 The U.S. Department of Energy (DOE) will have ownership of the cask and license, and the Certificate of Compliance will be issued to the DOE.

The cask will be used by government and university facilities that promote the general health and safety of the public through research, training, and isotope production.

The Oak Ridge National Laboratory and the Brookhaven National Laboratory will be the principal users of this cask.

Therefore, GNSI requests that the license application fees be waived in accordance with 10 CFR i

170.11, (Item #5).

f nostcmage onve.counna souincomemo.mmawa.% w

G Mr. Charles E. MacDonald 11/18/87 Page 2 Please contact me if you or members of your staff have any questions concerning this submittal.

Sincerely yours, General Nuclear Systems, Inc.

b/dA C

Robert T. Anderson t

Director, Cask and Transportation Systems RTA/ccr c:

J. A. Lenhard (DOE-0R0)

A. L. Lotts D. M. McGinty H. Postma - RC D. Stonebridge (BNL)

0

. l.:

- c.

l f

DOCKET No.

ll-VA/V CONTROL NO.

Njff 8[l))(([7.

//

__f DATEOF000.

DATE RCVD.

FCUF png FCAF LPDR.

l & E REF. __

SAFEGUARDS FCTC OTHER DATE /

7 INITIAL _

_ _ _ _ -