ML20236T277
| ML20236T277 | |
| Person / Time | |
|---|---|
| Site: | Callaway |
| Issue date: | 07/22/1998 |
| From: | Laux J UNION ELECTRIC CO. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| 50-483-97-05, 50-483-97-5, ULNRC-3868, NUDOCS 9807280075 | |
| Download: ML20236T277 (2) | |
Text
F..
i Union Docuic PO Box 620 Callaway Pfart Fulton, MO 05:51 l
l July 22,1998 l
U. S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop PI-137 Washington, DC 20555-0001 ULNRC-3868 gg Gentlemen:
- E AMcNoen RePLv To NoT1Ce og viotATioN INSPECTION REPORT NO. 50-483/97005 CALLAWAv PLANT UNION ELECTRIC Co.
Ref: ULNRC-3670, dated November 20,1997 This letter amends our previous response to Mr. MerschofTs letter dated October 22, 1998, which transmitted a Notice of Violation for events discussed in Inspection Report 50-483/97005. Our response to violation A is revised as follows.
The response to violation A stated in part that, Technical Specification Interpretations (TSIs) not dependent on approval ofImproved Technical Specifications (ITS) will be deleted where possible by August 1,1998. To date,16 of the 20 identified TSIs have been deleted. The remaining 4 identified TSis will be deleted by September 30,1998.
/
o None of the material in the response is considered proprietary by Union Electric.
If you have any questions regarding this response, or if additional information is k
required, please let me know.
Very tmly yours, P
, u, c a,
gy J. V. Laux l
Manager, Quality Assurance JVL/ MAR /tmw 9807280075 980722 PD81 ADOCK 05000483 G
r__
p.
- 9 i
ULNRC-3868 Juif22,1998 Page 2 cc: Mr. Ellis W. Merschoff l-Regional Administrator L.-.
U.S. Nuclear Regulatory Commission Region IV
- 611 Ryan Plaza Drive, Suite 400 L
Arlington, TX 76011-8064 Senior Resident Inspector Callaway Resident Oflice l
U.S. Nuclear Regulatory Commission l
- 8201 NRC Road l.
Steedman, MO 65077 o
l-i Ms. Kristine M. Thomas (2 copies)~
Licensing Project Manager, Callaway Plant Oflice of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission l
Mail Stop 13E16 Washington, DC 20555-2738 I
l Manager, Electric Department Missouri Public Service Commission L
PO Box 360 -
l JeiTerson City, MO 65102 Mr. Thomas A. Baxter l
Shaw, Pittman, Potts, & Trowbridge 2300 N. Street N.W.
Washington, DC 20037 Manager, Plant Support Wolf Creek Nuclear Operating Corporation PO Box 411 Burlington, KS 66839 Y
g I:
l l.
t-.
. _ _ _ _ _ _ _ _ - _ _ _ _ - - - _ _ _ _ _ _ _ _ - - _ _ _ _ _ _ _ _ - _