ML20236S150

From kanterella
Jump to navigation Jump to search
Notification of 871203 Meeting W/Westinghouse,Sandia & Utils in Bethesda,Md to Discuss Westinghouse ECCS Evaluation Model Using SECY-83-472 Approach for Analysis of Westinghouse two- Loop Upper Plenum Injection Plants.Meeting Agenda Encl
ML20236S150
Person / Time
Issue date: 11/19/1987
From: Hsii Y
Office of Nuclear Reactor Regulation
To: Hodges M
Office of Nuclear Reactor Regulation
References
NUDOCS 8711240252
Download: ML20236S150 (4)


Text

NOV is 1967 MEMORANDUM FOR:

Marvin W. Hodges, Chief Reactor Systems Branch Division of Engineering & Systems Technology THRU:

R. C. Jones, Section Chief Thermal-Hydraulic Performance Section Peactor Systems Branch Division of Engineering & Systems Technology FROM:

Y. Gene Hsii, Nuclear Engineer Thermal-Hydraulic Performance Section Reactor Systems Branch i

Division of Engineering & Systems Technology

SUBJECT:

NOTICE OF FORTHCOMING MEETING WITH WESTINGHOUSE DATE & TIME:

Thursday, December 3, 1987 8:00am - 4:00pm LOCATION:

Westinghouse Office Erblich Manor Building 4901 Fairmont Avenue Bethesda, Maryland PURPOSE:

To discuss Westinghouse ECCS Evaluation Model using the j

SECY 83-472 approach for analysis of Westinghouse two-loop UPI plants. The meeting will involve Westinghouse 7 proprietary information and a copy of the Meeting Agenda is enclosed.

PARTICIPANTS:

Westinghouse Larry Hochreiter, Michael Young, Walt Schwarz, Sue Dederer Sandia National Laboratory John Kelly Northern State Power Co.

Tom Parker Wisconsin Electric Power Co.

Rich Kohrt MPR Ken Wolfe

{

NRC Wayne Hodges, Robert Jones, Gene Hsii, Don Dilanni, Gene Rhee 8711240252 hT PDR TOPRP PDR Y. Gene Hsii, Nuclear Engineer C

Thermal-Hydraulic Performance Section Reactor Systems Branch Division of Engineering & Systems Technology b

Enclosure:

As stated

/

7

()

U cc: See next page

Contact:

Y. Gene Hsii, SPXB, x29455 v

SRXB:DESp YHSII:'fh 11/gp/87

o MEETING NOTICE DISTRIBUTION CentralfFil'eV NRC Participants SRXB~R/F

"~

RJones NRC PDR GHsii L PDR DDilanni VStello GRhee TMurley/JSniezek

)

FMiraglia BSheron DCrutchfield SVarga AThadani BBoger Glainas GHolahan WLanning l

OGC-Bethesda EJordan JPartlow ACRS (10)

GPA/PA VWilson BKolostyak l

i L _ ___-_-_-___-_.

1 i

MEETING AGENDA I

THURSDAY, DECEMBER 3. 1987, 8AM At the Westinghouse Bethesda Office Wisconsin Electric Company and Northern States Power Company and Westinghouse Electric Corporation and U. S. Nuclear Regulatory Commission UPPER PLENUN INJECTION PROGRAM, PROPRIETARY MEETING 1.

Review Chapter 7 WCAP-10924, Volume 2 2.

Appendix K Compliance 3.

Volume 2 Question Responses 1

4.

Uncertainty Analysis Results of Sensitivity Analyses Methodology for Combining Uncertainties 5.

Schedule

l 4.

Document Ncme:

MTG NOTICE - HSII Requestor's ID:

HARRIS Author's Name:

Y. HSII/jh Document Comments:

MEETING NOTICE TO M. W. H0DGES FROM Y. HSII i

6

,