_... _

+

'Af g

Teiepnone (412) 393-ecco Nuclear Group

[n pp*njort, PA15077-0004 November 10, 1987 U. S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, DC 20555

Reference:

Beaver Valley Power Station, Unit No. 1 Docket No. 50-334, License No. DPR-66 Additional Information on Elimination of Postulated Primary Loop Pipe Ruptures as a Design Basis for Beaver Valley Unit 1 Gentlemen:

By letter-dated October 21, 1987, the NRC requested additional information on our -proposed elimination of postulated primary loop pipe ruptures as a

design basis for Beaver Valley Unit 1.

The following enclosed information provides our response to this request.

1.

Five (5) copies of WCAP-11317 Supplement 2

entitled,

" Verification of Fracture Mechanics Analysis Techniques Used

.in Support of the Technical Justification for Eliminating Large Primary Loop Pipe Rupture as the Structural Design Bases for Beaver _ Valley Unit 1 (Proprietary).

2.

Five (5) copies of WCAP-11318 Supplement 2

entitled,

" Verification of Fracture Mechanics Analysis Techniques Used in Support of the Technical Justification for Eliminating Large Primary Loop Pipe Rupture as the Structural Design Bases for Beaver Valley Unit 1 (Non Proprietary).

Also enclosed is a Westinghouse Application for Withholding, CAW-87-115, Accompanying Affidavit, and Proprietary Information Notice.

As this submittal contains information proprietary to Westinghouse Electric Corporation, it is supported by an affidavit signed by Westinghouse, the owner of the information.

The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b)(4) of Section 2.790 of the Commission's regulations.

N.pgor: Res-Fh e (4 C.rc pg0l

  1. Ac. t0R

,y

!w9na! f@

een (P0R P

I

.Benvar Valley Pow 3r Station, Unit No. 1 l

c.Dockst No. 50-334,. License No. DPR-66 Additional Information on' Elimination of Postulated i

Primary Loop Pipe Ruptures as a Design Basis for Beaver Valley Unit 1 Page 2.

1 Accordingly, it is respectfully requested that the information I

which is proprietary to Westinghouse be withheld from public l

disclosure in accordance with 10 CFR Section 2.790 of the l

-Commission's regulations.

Correspondence with respect to the i

proprietary aspects of the Application for Withholding or the I

supporting Westinghouse affidavit should reference CAW-87-115 l

and should be addressed to R. A. Wiesmann, Manager Regulatory

.l and Legislative

Affairs, Westinghouse Electric Corporation, i

P.O. Box 355, Pittsburgh, Pennsylvania 15230.

If there are any questions concerning this response, please contact my office.

Very truly yours, i

A 4Id,

J. D. Sieber Vice President, Nuclear f

cc: