.. _ - _ _ _ - - - - - _ - _ _ - - - _ - - - - - - - - - -. - - - -

c Northern States Power Company Prairie Island Nuclear Generating Plant 1717 Wakonade Dr. East Welch. Minnesota 55089 July 15,1998 U S Nuclear Regulatory Commission I

Attn: Document Control Desk Washington, DC 20555 PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket Nos. 50-282 License Nos. DPR-42 l

50-306 DPR-60 l

Transmittal of Non-Proprietary Classed l

Westinghoutte Preliminary Summary Root Cause Evaluation

{

l In a letter dated April 6,1998, NSP attached the Westinghouse report entitled, l

' " Metallurgical Investigation and Root Cause Assessment of Part Length CRDM Housing l

Motor Tube Cracking at Prairie Island Nuclear Generating Plant Unit 2 - Preliminary l

Summary Report." Westinghouse had classified this report as Proprietary Class 2.

)

Subsequently, Westinghouse has determined that this report can be classified as Non-Proprietary Class 3. A copy of the same report marked as such is attached and can j

replace the original report (submitted with the April 6,1998 letter).

In this letter we have made no new Nuclear Regulatory Commission commitments.

l Please contact Jeff Kivi (612-388-1121) if you have any questions related to this letter.

l

,I l

Joel P. Sorensen Plant Manager

/

Prairie Island Nuclear Generating Plant

\\

f \\.

4 i

9007220167 980715 PDR ADOCK 05000282' p

PDR

USNRC NORTHERN STATES POWER COMPANY July 15,1998

' Page 2 c: Regional Administrator-Region lil, NRC Senior Resident inspector, NRC NRR Project Manager, NRC J E Silberg Attachments:

1. Non-Proprietary Class 3 Westinghouse Report, " Metallurgical Investigation and Root Cause Assessment of Part length CRDM Housing Motor Tube Cracking at Prairie Island Nuclear Generating Plant Unit 2" i

transmit nonproprietary W root cause preliminary report. DOC I

i E--_-_____---.--------------

4 l

4 Non-Proprietary Class 3 Westinghouse Report MetallurgicalInvestigation and Root Cause Assessment of Part Length CRDM Housing Motor Tube Cracking at Prairie Island Nuclear Generating Plant Unit 2 l

l l

l l

l

_.