l Commonwealth Edison Company

. 1400 Opus Place Downers Grove, IL 60515-5701 July 16,1998 ,

United States Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Braidwood Station, Units 1 and 2 Facility Operating Licenses NPPF-72 and NPF-77 NRC Docket Numbers 50-456 and 457 Byron Station, Units 1 and 2 Facility Operating Licenses NPF-37 and NPF-66 NRC Docket Numbers 50-454 and 455)

Dresden Nuclear Power Station, Units 1,2, and 3 Facility Operating Licenses DPR-2, DPR-19, and DPR-25 NRC Docket Numbers 50-10. 237 and 249

, LaSalle County Station, Units I and 2 facility Operating Licenses NPF-11 and NPF-18 NRC Docket Numbers 50-373 and 374 Quad Cities Nuclear Power Station, Units 1 and 2 Facility Operating Licenses DPR-29 and DPR 30 NRC Docket Numbers 50-254 and 265 Zion Nuclear Power Station, Units 1 and 2 Facility Operating Licenses DPR-29 and DPR-30 NRC Docket Numbers 50 295 and 304 j

{

Subject:

Summary ofInterim Emergency Operations Facility Response Drills through May 31,1998

Reference:

" Commonwealth Edison Submittal: Proposal to Consolidate Near Site  ;

Emergency Operations Facilities (EOFs) into a Central EOF," Comed i letter, John C. Brons to United States Nuclear Regulatory Commission, dated January 5,1998.

On March 26,1998, Commonwealth Edison (Comed) and the Nuclear Regulatory i Commission (NRC) held a meeting to discuss progress toward a single central Emergency Operations Facility (EOF) for Comed. At that meeting Comed committed to k g' provide a report following each actual (i.e., drive-in) staffing drill for the existing Corporate EOF (CEOF). This letter constitutes the first such report. This report  !

summarizes the results of the drive-in drill as well as the preceding call-in drills conducted between each drive-in drill. y g- '

9007210323 900716  !

PDR ADOCK 05000010 F PDR.

gAnlaVion\lic-98-070.dx\l A Unicom Company E_____.___________

Comed conducted an unannounced drive-in drill on May 14,1998. The required staff arrived at the CEOF within 40 minutes from the classification time. This is well within our one-hour staffing commitment. The drill was conducted using the same activation and notification system that would be used for an actual event. No corrective actions are needed as a result of this drill.

On April 13,1998 Comed adopted a dedicated on-call team philosophy to further enhance both our staffing capabilities and the teamwork of responding staff. Six weekly telephone response drills were conducted between the April 13,1998 program activation date and May 31,1998. Four of these drills demonstrated acceptable performance, with staffing time within our one hour criteria. One drill was evaluated as weak, with a projected staffing time of 61 minutes. Another drill was classified as indeterminate because a recording discrepancy for a single member of the response team made that individual's response time indeterminate. This recording discrepancy has not recurred in subsequent drills. No corrective actions are planned as a result of any of these drills.

As commited to during our meeting on March 26,1998, Comed will provide a historical summary of the results and corrective actions taken for the drills conducted between May 1997 and April 13,1998, in our submittal to update our proposal for a central EOF.

Please direct any questions pertaining to this submittal to Leslie E. Holden at (630) 663-7279.

Sincerely,

/

/

R. M. Kric i Vice President - Regulatory Services J cc: Regional Administrator,NRC/RegionIII  ;

NRC Senior Resident Inspector, Braidwood Station '

NRC Senior R.esident Inspector, Byron Station j NRC Senior Resident inspector, Dresden Nuclear Power Station  ;

NRC Senior Resident inspector, LaSalle County Station NRC Senior Resident Inspector, Quad Nuclear Power Cities Station NRC Senior Resident Inspector, Zion Nuclear Power Station g \nla\rion'Jic-98-070 doc \2