MEMORANDUM TO: George Pangburn, Deputy Director July 14, 1998 Division of Nuclear Materials Safety, RI Douglas M. Collins, Director Division of Nuclear Materials Gafety, Ril Roy J. Caniano, Deputy Dirrctor Division of Nuclear Matericts Safety, Rlll Linda L. Howell, Deputy Director Division of Nuclear Material Safety, RIV FROM:
Larry W. Camper, Chief (orig. signed by)
Material Safety Branch Division of Industrial and Medical Nuclear Safety, NYSS
SUBJECT:
STATUS OF SEALED SOURCE AND DEVICE REQUEST FOR REGISTRATION Attached are listings of the sealed source and device pending cases cs of July 13,1998. contains actions that were submitted as a Technical Assistance Request from Headquarters or the Regions, and Attachment 2 lists all actions that have been filed directly by the vendor and regions, for product evaluation and registration.
Attachments: As stated I[I CONTACT: Traci Kime, NMSS/IMNS (301) 415-8140.
DISTRIBUTION: w/ enclosures VCampbell, RIV w/o encls JKinneman, RI SMoore, OB NMtW r/f IMNS r/f JMadera, Rill CHosey, Rll MPhillips, Rlll FCombs MLesser, R!l MShanbaky, RI SKimberly, LFDCB DCool JJohansen,RI CFrazier, Rlli Blough, RI BPrange,RIV WCFO GShear, Rill FCostello, RI MMeenan, Rill LJacobs-Bayna 'd, PMDA SVillar, RI TDecker, Ril NEO2-SSD-7 lQ CCain, RIV CPederson, Rlli DChamberlaihf RIV BSpitzberg, RIV DOCUMENT NAME: G:\\ Regions. Reg To receive a copy of this document, indicate in the box: "C" = Copy witho ttachment/ enclosure
- E" = Copy with attachment /encio
= No copy OFFICE MSB ld MSBG4 l(
MS,B / j[
J l
l NAME TKime s_ d/K SBaggett L&q $F l "
DATE 7//J/98 7/0 /98 t/ $WQ l
OFFICIAL RE;OTD COPY 2c02 IRC FU CBMlCDPY "3
9807210167 980714 PDR RC SSD PDR
t l
e Pending Sealed Source & Device Actions l
Tied to Licensing Actions By Region for the period 1/1/01 to 7/13/98 Actions recorded as of Monday, July 13,1998 HQ 3 case (s) Assigned to Reviewer (s) Iotaling 3 Action (s)
Number l Assign. #
control Actions Reviewer Company Model Numbers i
0 97-55 Kirkwood Walter Kidde Port. Equip.
SMD1, 0805, 0905, 0906, 0908, 0914,0916, 1
0918 0
98-32 Kirkwood Kidde Safety Model 1285 1
021700 97-62 Lee Universal Secunty Nst.
Senes SS-750 1
1 Sealed Source Safety Section
Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 7/13/98 Actions recorded as of Monday, July 13,1998 RI Z Uase(s) Assigned to Heviewer(s) Iotaling Z Action (s)
Control Assign. #
Number Actions Reviewer Company Model Numbers 12585 98-41 Lee Epsilon Polyolefin Corp.
Beta gauge device 1
124672 97.48 Compton Allegheny University Hosp.
SrO.A53 1
1 Sealed Source Safey Section I
(
Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 7/13/98 Actions recorded as of Monday, July 13,1998 SSSS 59 Case (s) Assigned to Keviewer(s) Iotaling 13U Action (s)
Control Assign. #
Number Actions Reviewer Company Model Numbers 0
96-35 Compton DMW Geophysical EUDI, TUD1 1
0 96-36 Compton Stock Equipment Company D26752 1
0 96-37 Burgess American Airknes Rigid guide tube /collimater 1
l 0
96-38 Burgess TWA Rigid guide tube l
0 S6-85 Compton Agfa Corporation BKG 40823-01 1
{
i 0
96-87 Burgess Dept. of Agnculture Husman irradiator 1
1 0
97-07 Jankovich Nuclear Research Corp.
SH-301, SH-302, SH-352 1
0 97-23 Compton FEMA CDV-757 1
0 97-24 Compton FEMA CDV-778,782,784,786 1
0 97-25 compton FEMA CDV-794 Model No. 2 1
0 97-26 Compton FEMA CDV-797 1
1 Sealed Source Safety Section
Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 7/13/98 Actions reCoried as of Monday, July 13,1998 SSSS 59 Uase(s) Assigned to Keviewer(s) Iotaling 130 Action (s) control Assign. #
Number Actions Reviewer Company Model Numbers 0
97-27 Compton FEMA CDV-791, CDV-792 1
0 97-28 Compton FEMA CDV-790 Model 1 1
0 97-30 Compton GE Medical Systems Model 2180506 1
0 9742 Jankovich Apgee Corporation LB 379 1
0 97-43 Jankovich Apgee Corporation LB 300 ULP 1
0 97-44 Jankovich Apgee Corporation LB 300 IRL 1
0 97-45 Jankovich Apgee Corporation LB 300 MUMLT 1
0 97-46 Jankovich Apgee Corporation LB 300 MUMLT 1
0 97-47 Compton Stocker & Yale P650 1
0 97-59 Lee Stocker & Yale 80800, 490,184-0,184-B1, 5903, 5904, 5905 1
0 97-61 Lee Lockheed Martm 5310,5310-1,5310-3,5310-5 1
2 Sealed Source Safety Section i
I
Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 7/13/98 Actions recorded as of Monday, July 13,1998 SSSS 59 Case (s) Assigned to Heviewer(s) Iotaling 130 Action (s) control Assign. #
Number Actions Reviewer Company Model Numbers 0
97-63 Burgess Perkin Elmer Voyager 1
0 97-76 Lee Apgee Corporation LB BW 1
0 97-77 Lee Apgee Corporation LB 375 1
0 97 78 Lee Dept. of the Army ACADA 1
0 97-80 Lee RSNP RSNP-AU 1
0 97-61 Lee RSNP RSNP-lR, RSNP-2 1
0 97-83 Lee Nuclear Research Corp.
SH-300 Senes, LS-101 2
0 9842 Lee Seaman Nuclear Corp.
C 100, C-200 1
0 98-05 Lee Seaman Nuclear Corp.
C-300 I
I O
98-09 Jankovich MDS Nordion Gammacell 1000/3000 1
0 98-10 Lee Eberline instrument Corp 8150-120-CS 1
1 Sealed Source Safety Section
__________________________________U
Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 7/13/98 Actions recorded aS of Monday, July 13,1998 SSSS 59 Case (s) Assigned to Heviewer(s) Iotaling 13U Action (s) control Assign. #
Number Actions Reviewer Company Model Numbers 0
98-11 Lee Ebertine Instrument Corp.
8150-xxxAB 1
0 98-12 Lee Eberkne instrument Corp.
1000 1
I O
98 13 Lee Eberkne instrument Corp.64-764 1
0 98-14 Lee Eberline Instrument Corp.
1000 B 1
0 98-15 Lee Eberkne Instrument Corp.
SCS 1001-1008 1
0 98-16 Lee Eberkne instrument Corp.
DNS-5 1
0 98-17 Lee Eberkne Instrument Corp.
DNS-SA 1
0 98-18 Lee Eberkne Instrument Corp.
S94-1 S94-2, S94-4 1
0 98-19 Lee Eberkne Instrument Corp.
DNS-7, DNS-10, DNS-17 1
0 98-20 Lee Eberkne Instrument Corp.
DNS-1, DNS-16, DNS-21
)
1 0
98-21 Lee TMA/Ebertine CS-1, CS-3, CS-10, CS-12. CS-15. CS-16 1
1 Sealed Source Safety Section I
l
Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/G1 to 7/13/98 Actions recorded as of Monday, July 13,1998 SSSS 59 Gase(s) Assigned to Heviewer(s) Iotaling 130 Action (s)
Control Assign. #
Number Actions Reviewer Company Model Numbers 0
98-22 Lee TMA/Eberline CS-7A, CS-7B 1
1 0
98-23 Lee TMA/Eberline DNS-26 l
l 1
)
0 98-24 Lee TMA/Eberline DNS-8, DNS-9 i
I 1
0 98-25 Lee TMA/Eberline DNS-6 I
1 i
1 0
98-26 Lee TMA/Eberline DNS-4, DNS-11, S-1 1
0 98-27 Lee TMA/Eberline DNS-2, DNS-14 1
0 93-31 Jankovich MDS Nordion C-188 1
0 98-33 Lee Dept. of the Air Force D-0062 i
1 1
1 0
98-34 Jankovich Ohmart Corporation SHRH-A 1
0 98-35 Jankovich MDS Nordion Gammacell 40 1
0 98-36 Lee Advanced Gauging AGT 400 1
l 1
Sealed Source Safety Section I
Pending Sealed Source & Device Actions i
Tied to Licensing Actions By Region for the period 1/1/01 to 7/13/98 Actions recorded as of Monday, July 13,1998 SSSS 59 Gase(s) Assigned to Heviewer(s) Iotaling 130 Action (s)
Gontrol Assign. #
Number Actions Reviewer Company Model Numbers 0
98-38 Jankovich SMV TAC 1
0 98-39 Bhachu GE Medical Systems V., Transact 1
0 98-44 Lee Gamma industries, Inc.
P-10 PTL-1, S-17 3
i 0
98-45 Lee Gamma Industries, Inc.
Vanous 12 j
i l
0 98-47 Compton Gamma industres, Inc.
C-10 1
l l
l 0
98-48 Compton Gamma industries, Inc.
Gammatron 50-A l
1 0
98-49 Compton Gamma industres, Inc.
Tattletale Model 1 1
0 98-50 Compton Garrma industries, Inc.
Pipeliner Model 201 1
0 98-51 Compton Gamma industnes, Inc.
180 1
0 98-52 Compton Gamma industries, Inc.
Pipeliner Model 300 1
i 1
0 98-53 Compton Gamma industnes, Inc.
Gammatron 100,100A,200,200A i
1 Sealed Source Safety Section l
Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 7/13/98 Actions recorded as of Monday, July 13,1998 SSSS 59 case (s) Assigned to Heviewer(s) Iotaling 130 Action (s) control Assign, #
Number Actions Reviewer Company Model Numbers 0
98-54 Compton Gamma industries. Inc.
S2-15SA 1
0 98-55 Compton Gamma industnes, Inc.
Master Minder Model 2 1
l 0
98-56 Compton Gamma industnes, Inc.
1002 1
0 98-57 Compton Gamma industries, Inc.
1001 1
0 98-58 Compton Gamma industries, Inc.
Vanous 19 0
98-59 Lee GammaMed USA GammaMed Model 12it, and 12i 1
0 98-60 Bhachu Bethlehem Steel Corp.
28-8 1
0 98-62 Lee Edwards Systems Technology No model number listed in letter.
1 0
98-63 Bhachu Medtronic, Inc.
1 0
98-64 Lee Gamma industnes, Inc.
Various 5
0 9845 Lee Gamma Industnes, Inc.
Various 4
1 Sealed Source Safety Section
-.- ---~-- ' ~ ~ -
~
- ~ - - -
Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 7/13/98 Actions recorded as of Monday, July 13,1998 SSSS 69 case (s) Assigned to tieviewer(s) Iota!ing 130 Action (s)
Control Assign. #
Number Actions Reviewar Company Model Numbers 0
98-43 Compton Metorex SIPS X-RAY PROBE 1
0 98-66 Compton Apgee Corporation LB 7400 Senes 1
0 98-67 Jankovich Department of Health Bolo Tie, Dress Pin 1
0 98-68 Unassigned NUMEC AM-CS-1Narious 2
0 94-69 Unassigned Kidde Safety Various 1
0 98-70 Unassigned MDS Nordion C-337A 1
0 98-71 Jankovich Ohmart Vega Various 2
0 98-72 Jankovich OhmartNega SHLG Senes 1
0 98-73 Unassigned OhmartNega SHF & SH-1 Senes 1
0 98-74 Unassigned OhmartNega SR Senes 1
0 98-75 Unassigned Maple Chase Company 1
1 Sea!ed Source Safety Section
I Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 7/13/98 Actions recorded as of Monday, July 13,1998 SSSS 59 Case (S) Assigned to Heviewer(S) Iotaling 130 Action (s)
Control Assign. #
Number Actions Reviewer Company Model Numbers 0
98-76 Unassigned BSIinstruments NW-201,301,401,501 Senes 1
Sealed Source Safety Section
Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 7/13/98 Actions recorded as of Monday, July 13,1998 SSSS 59 Gase(s) Assigned to Reviewer (s) Iotaling 130 Action (s) control Assign, #
Number Actions Reviewer Company Model Numbers Total Open Case (s) for All Regions is 94 Totaling 135 Action (s) l l
l 1
Sealed Source Safety Section f
1
1 Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to - 7/13/98 l
For actions recorded as of Monday, July 13,1998 Date Assign. #
Received Reviewer Actions Company Model Numbers Status l
4/24/96 96-35 Compton 1 DMW Geophysical EUD1, TUD1 N/A from fees Action has been transferred to E. Compton.
4/26/96 96-36 Compton 1 Stock Equipment D26752 To fees on 4/29/96.
j Company Rtmed frm fees on 5/3/96.
Action has been transferred to E. Compton.
4/26/96 96-38 Burgess 1 TWA Rigid guide tube To fees on 5/2/96 Rtrned frm fees on 5/21/96.
Additionalinf. revd on 8/26/96.
Working on action w/conjuction w/96-04.
Def. Itr sent on 4/28/98.
96-04 transfered to MA on 3/97.
Def. Itr sent on 10/30/97.
30-day extension was given till 1/5/98.
Def. resp revd on 1/6/98.
4/30/96 96-37 Burgess 1 American Airlines Rigid guide tube /collimater To fees on 5/1/96 New Fee ruling Rtmed frm fees on 5/28/96.
Additionalinf. revd on 8/26/96.
Working on action w/conjuction w/96-04 96-04 transfered to MA on 3/97.
Def. ttr sent on 10/30/97.
Def. resp. revd on 11/18/97.
Def. call & Ltr sent on 11/18/97.
Def, resp revd on 1/6/98.
1 Sealed Source Safety Section 1
1
Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/13/98 For actions recorded as of Monday, July 13,1998 Date Assign. #
Received Reviewer Actions Company Model Numbers Status 8/19/96 96-85 Compton 1 Agfa Corporation BKG 40823-01 To Fees on 8/20/96.
Rtrned frm fees on 8/22/96.
Action is with Fred Combs 4/29/97.
Action has been transferred to E. Compton.
l l
9/25/96 96-87 Burgess 1 Dept.of Agnculture Husman irradiator To fees on 9/30/96-Rtrned frm fees on 10/4/96.
Def. call on 9/25/96.
30 day void Itr sent on 1/17/97.
Resp. revd on 3/5/97, 2/25/97 97-07 Jankovich 1 Nuclear Research SH-301, SH-302, SH-352 To fees on 2/26/97.
Corp.
Rtmed frm fees on 3/3/97.
Action has been reassigned to J. Jankovich on 10/17/97.
Def. ftr sent on 10/31/97.
Ltr dat ed 1/5/98 frm applicant requesting extension.
Resp. revd on 2/12/98.
Lir sent to retum propnetary drawings on 3/9/98.
Revd replacement drawings on 3/17/98.
2 Sealed Source Safety Section
Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/13/98 For actions recorded as of Monday, July 13,1998 Date Assign. #
Received Reviewer Actions Company Model Numbers Status 3/28/97 97 30 Compton 1 GE Medical Systems Model 2180506 To fees on 4/3/97 Rtrned frm fees on 4/8/97, Def Itr sent on 2/23/98.
Resp. rcvd on 3/20/98.
Revised affidavit dtd 5/8/98.
4/1/97 97 23 Compton 1 FEMA CDV-757 To Fees on 4/2/97.
Rtrned frm fees on 4/8/97.
4/1/97 97 24 Compton 1 FEMA CDV-778, 782, 784,786 To Fees on 4/2/97, Rtrned frm fees on 4/8/97.
4/1/97 97 25 Compton 1 FEMA CDV-794 Model No,2 To Fees on 4/2/97.
Rtmed frm fees on 4/8/97.
4/1/97 97-26 Compton 1 FEMA COV-797 To Fees on 4/2/97.
Rtmed frm fees on 4/8/97.
J 4/1/97 G7-27 Compton 1 FEMA CDV-791, CDV-792 To Fees on 4/2/97.
Rtrned frm fees on 4/8/97.
4/1/97 97-28 Compton 1 FEMA CDV 790 Model 1 To Fees on 4/2/97.
Rtmed frm fees on 4/8/97.
6/12/97 97-42 Jankovich 1 Apgee Corporation LB 379 To Fees on 6/12/97.
Rtrned frm fees on 6/16/97.
Inactive request dated 12/5/97.
3 Sealed Source Safety Section
Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/13/98 For actions recorded as of Monday, July 13,1998 Date Assign. 5 Received Reviewer Actions Company Model Numbers Status 6/12/97 97-43 l
Jankovich 1 Apgee Comoration LB 300 L/t P To Fees on 6/12/97.
I Rtrned frm fees on 6/16/97.
i inactive request dated 1
l 12/5/97.
I l
Ltr frm applicant on 12/18/97 requesting that case remain i
l active until 2/1/98.
l 6/12/97 97-44 Jankovich 1 Apgee Corporation LB 300 IRL To Fees on 6/12/97.
Rtrned frm fees on 6/16/97.
Inactive request dated 12/5/97.
Ltr frm applicant on 12/18/97 requesting that case remains active until 2/1/98.
6/12/97 97-45 Jankovich 1 Apgee Corporation LB 300 ML/MLT To Fees on 6/12/97.
Rtrned frm fees on 6/16/97.
6/16/97 97-46 Jankovich 1 Apgee Corporation LB 300 MUMLT To Fees on 6/16/97.
See also 97-45 Rtrned frm fees on 6/18/97.
6/17/97 97-47 Compton 1 Stucker & Yale P650 To Fees on 6/17/97.
Rtrned frm fees on 2/18/98.
Continuation of 97-59.
6/20/97 97-48 Compton 1 Allegheny University SrO.A53 To Fees on 6/20/97.
Hosp.
Rtrned frm Fees on 9/16/97.
Def. Itr sent on 1/15/98.
l Resp. rcvd on 4/15/98.
4 Sealed Source Safety Section u
Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/13/98 For actions recorded aS of Monday, July 13,1998 Date Assign. #
Received Reviewer Actions Company Model Numbers Status 8/14/97 97-55 Kirkwood i Walter Kidde Port.
SMD1, 0805, 0905, 0906, 0908. To Fees on 8/21/97.
Equip.
0914,0916, 0918 Rtrned frm fees on 9/5/97.
9/2/97 97-59 Lee 1 Stocker & Yale 80800,450,184-B,184-B1, To Fees on 9/5/97.
5903.5904,5905 Rtmed frm fees on 9/26/97.
9/23/97 97-61 Lee 1 Lockheed Martin 5310,5310-1,5310-3,5310-5 To Fees on 9/23/97, Rtrned frm fees on 9/26/97.
Def. Itr sent on 2/19/98.
9/26/97 97-62 Lee 1 Universal Secunty inst.
Senes SS-750 To Fees on 9/29/97.
Rtrned frm fees on 10/6/97.
Action is a continuation of 95-01 and 94-38 10/14/97 97-63 Burgess 1 Perkin Elmer Voyager To Fees on 10/15/97 Def. call on 10/28/97.
Rtmed frm fees on 11/7/97.
Def. call on 11/4/97.
Respanse rec'd 5/20/98.
Def. call 5/29/98. (Resp. not sufficient).
Def. call 5/6/98.
Info. expected week of 5/18/98 Def. resp. revd on 1/6/98.
Def. call on 2/3/98.
Def. resp. revd on 2/4/98.
Partial def. resp. rec'd 6/10/98.
Remainder expected by 6/12/98.
Deficiency resp rec'd 6/25/98.
12/9/97 97-76 Lee 1 Apgee Corporation LB BW To Fees on 12/10/97.
Rtmed frm fees on 12/30/97.
5 Sealed Source Safety Section I
Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/13/98 For actions recorded as of Monday, July 13,1998 I
Date Assign. #
Received Reviewer Actions Company Model Numbers Status 12/9/97 97 77 Lee 1 Apgee Corporation LB 375 To Fees on 12/10/97, Rtmed frm fees on 12/30/97.
12/9'97 97-78 Lee i Dept. of the Army ACADA To Fees on 12/11/97.
Rtrned frm fees on 12/30/97.
Def. call 5/11/98, Response expected 5/18/98.
Partial resp rec'd 5/18/98.
Partial resp rec'd 5/20/98.
Remaining def resp rec'd 5/26/98.
Spoke w/ app. 6/10/98 informing that resp. still was insufficient.
Preparing def. ltr.
Def. Itr sent on 7/2/98.
12/19/97 97-80 Lee 1 RSNP RSNP-AU To Fees on 12/29/97.
12/19/97 97-81 Lee 1 RSNP RSNP-IR, RSNP-2 To Fees on 12/29/97.
12/23/97 97-83 Lee 2 Nuclear Research SH-300 Senes, LS-101 To fees on 12/30/97.
Corp.
1/5/98 98-02 Lee 1 Seaman Nuclear Corp.
C-100 C-200 To Fees on 1/5/98 Rtrned frm fees on 1/14/98 Continuation of 95-115 Action has been reassigned to S Lee on 1/29/98.
Def. itr sent on 4/16/98.
Response rec'd on 6/3/98.
I l
l 6
Sealed Source Safety Section 1
l
Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/13/98 For actions recorded aS of Monday, July 13,1998 Date Assign. #
Received Reviewer Actions Company Model Numbers Status 1/6/98 9845 l
Lee 1 Seaman Nuclear Corp.
C-300 To Fees on 1/7/98.
Case has been reassigned to S Lee on 1/29/98.
Rtrned frm fees on 2/2/98.
Def. Itr sent on 4/16/98.
Response roc'd on 6/3/98.
l 1/15/98 98-09 Jankovich 1 MDS Nordion Gammacell 1000/3000 To Fees on 1/20/98.
Rtmed frm fees on3/2/98.
Def. call on 3/25/98.
Def. Itr sent on 6/19/98.
2/4/98 98-10 Lee 1 Eberkne instrument 8150-120-CS To Fees on 2/18/98 Corp.
Rtrned frm fees on 2/18/98.
2/4/98 98-11 Lee 1 Eberline instrument 8150-xxxAB To Fees on 2/18/98.
Corp.
Rtrned frm fees on 2/18/98.
2/4/98 98-12 Lee 1 Eberkne instrument 1000 To Fees on 2/18/98 Corp.
Rtmed frm fees on 2/18/98.
2/4/98 98-13 Lee 1 Eberkne instrument 64 764 To Fees on 2/18/98.
Corp.
Rtmed frm fees on 2/18/98.
2/4/98 98-14 Lee i Eberkne instrumerit 1000 B To Fees on 2/18/98.
Corp.
Rtmed frm fees on 2/18/98.
2/4/98 98-15 Lee 1 Eberkne Instrument SCS 1001-1008 To Fees on 2/18/98.
Corp.
Rtrned frm fees on 2/18/98.
2/4/98 98-16 Lee 1 Eberkne Instrument DNS-5 To Fees on 2/18/98 Corp.
Rtrned frm fees on 2/18/98 2/4/98 98-17 Lee 1 Eberkne Instrument DNS-5A To fees on 2/18/98.
Corp.
Rtrned frm fees on 2/18/98.
7 Sealed Source Safety Section
Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/13/98 For actions recorded aS of Monday, July 13,1998 Date Assign. #
Received Reviewer Actions Company Model Numbers Status 2/4/98 98-18 Lee 1 Ebertine instrument S94-1, S94-2 S94-4 To Fees on 2/18/98.
Corp.
Rtrned frm fees on 2/18/98.
2/4/98 98-19
)
Lee
' Ebertine Instrument DNS-7, DNS-10 DNS-17 To Fees on 2/18/98.
Corp.
Rtmed frm fees on 2/18/98.
1 2/4/98 98-20 Lee 1 Ebertine Instrument DNS-1, DNS-16, DNS-21 To Fees on 2/18/98.
Corp.
Rtrned frm fees on 2/18/98.
2/4/98 98-21 Lee 1 TMA/Eberkne CS-1, CS-3, CS-10 CS-12, To fees on 2/18/98.
CS-15, CS-16 Rtrned frm fees on 2/18/98.
2/4/98 98-22 Lee 1 TMA/Eberkne CS-7A, CS-78 To fees on 2/18/98.
Rtmed frm fees on 2/18/98.
2/4/98 98-23 Lee 1 TMA/Eberkne DNS-26 To fees on 2/18/98.
Rtrned frm fees on 2/18/98.
2/4/98 98-24 Lee 1 TMA/Eberkne DNS-8, DNS 9 To fees on 2/18/98.
Rtmed frm fees on 2/18/98 2/4/98 98-25 Lee 1 TMA/Eberkne DNS-6 To fees on 2/18/98.
Rtrned frm fees on 2/18/98.
2/4/98 98-26 Lee 1 TMA/Eberkne DNS-4, DNS-11, S-1 To fees on 2/18/98.
Rtrned frm fees on 2/18/98.
2/4/98 98-27 Lee 1 TMA/Eberkne DNS-2, DNS-14 To fees on 2/18/98.
Rtmed frm fees on 2/18/98.
2/19/98 98-31 Jankovich 1 MDS Nordion C-188 To Fees on 2/23/98.
Acknowledgment Ltr sent on 3/5/98.
Rtmed frm Fees on 3/6/98 8
Sealed Source Safety Section l
I L
Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/13/98 For actions recorded as of Monday, July 13,1998 Date Assign. #
Received Reviewer Actions Company Model Numbers Status 2/27/98 98-32 Kirkwood 1 Kidde Safety Model1285 To Fees on 2/27/98.
Acknowledgment Ltr sent on 3/5/98.
Def. telephone call on 4/14/98.
Responsed on 4/23/98.
Second def. call on 4/28/98.
3/2/98 98-33 Lee i Dept. of the Air Force D-0062 To Fees on 3/18/98.
Rtrned frm fees on 3/20/98.
Acknowledgment ltr sent on 3/20/98.
3/2/98 98-34 Jankovich 1 Ohmart Corporation SHRH-A To Fees on 3/2/98.
Acknowledgment Ltr sent on 3/5/98.
Rtrned frm Fees on 3/20/98.
3/3/98 98-35 Jankovich 1 MDS Nordion Gammacell 40 To Fees on 3/3/98.
Acknowledgment Itr sent on 3/5/98.
Rtmed frm fees on 4/3/98.
3/5/98 98-36 Lee 1 Advanced Gauging AGT 400 To Fees on 3/5/98.
Acknowledgment Ltr sent on 3/9/98.
Rtrned frm fees on 3/30/98.
3/16/98 98-38 Jankovich 1 SMV TAC To Fees on 3118/98.
Rtrned frm Fees on 3/20/98.
Acknowledgment Itr sent on 3/20/98 Def. ftr sent on 6/12/98.
l 9
Sealed Source Safety Section i
Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/13/98 For actions recorded as of Monday, July 13,1998 Date Assign. #
Received Reviewer Actions Company Model Numbers Status 3/30/98 98-39 Bhachu 1 GE Medical Systems V Transact To Fees on 3/30/98.
Acknowledgment Itr sent on 4/2/98.
Rtrned frm fees on 4/3/98.
Response sent 5/29/98.
l l
l 4/16/98 98-41 l
Lee 1 Epsilon Polyolefin Corp. Beta gauge device To Fees on 4/16/98.
Retumed from Fees 6/15/98.
4/27/98 98-44 Lee 3 Gamma industres, Inc.
P-10 PTL-1, S-17 To fees 4/27/90.
Acknowledger.t ltr N/A.
Back from fees 4/30/98.
4/27/98 98-45 l
Lee 12 Gamma industnes, Inc. Various To fees 4/27/98.
Acknowledgment ltr N/A.
Back from fees 4/30/98.
1 4/27/98 98-43 Compton 1 Metorex SIPS X-RAY PROBE To fees on 4/27/98 Acknowledgment letter sent on 4/27/98.
Back from fees 4/30/98.
Def. Itr sent 6/3/98.
5/8/98 98-47 Compton 1 Gamma industries, Inc. C-10 To fees 5/8/98 Rtd from fees 5/29/98.
5/8/98 98-48 Compton 1 Gamma Industries, Inc. Gammatron 50-A To fees 5/8/98.
Rtd from fees 5/29/98.
i 5/8/98 98-49 i
Compton 1 Gamma industnes, Inc. Tattletale Model 1 To fees 5/8/98.
Rtd from fees 5/29/98.
5/8/98 98-50 1
Compton 1 Gamma industries, Inc. Pipeliner Model 201 To fees 5/8/98.
i Rtd from fees 5/29/98.
5/8/98 98-51 Compton 1 Gamma industnes, Inc.
180 To fees 5/8/98 Rtd from fees 5/29/98.
10 Sealed Source Safety Section
I l
l Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/13/98 l
For actions recorded as of Monday, July 13,1998 I
Date Assign. #
Received Reviewer Actions Company Model Numbers Status 5/8/98 98-52 Compton 1 Gamma industres, Inc. Pipeliner Model 300 To fees 5/8/98 Rtd from fees 5/29/98.
l 5/8/98 98-53 l
Compton 1 Gamma industres, Inc. Gammatron 100,100A,200 To fees 5/8/98.
l 200A Rtd from fees 5/29/98.
5/8/98 98-54 Compton 1 Gamma industnes, Inc. S2-15SA To fees 5/8/98.
Rtd from fees 5/29/98.
5/8/98 98-55 Compton 1 Gamma industres, Inc. Master Minder Model 2 To fees 5/8/98.
Rtd from fees 5/29/98.
5/8/98 98-56 Compton 1 Gamma industries, Inc.
1002 To fees 5/8/98.
Rtd from fees 5/29/98.
5/8/98 98-57 Compton 1 Gamma Industries, Inc.
1001 To fees 5/8/98.
[
Rtd from fees 5/29/98.
5/8/98 98-58 Compton 19 Gamma industres, Inc. Various To fees 5/11/98.
Rtd from fees 5/29/98.
l 5/11/98 98-59 i
Lee 1 GammaMed USA GammaMed Model 12it, and 12i To fees 5/12/98.
Ret. from fees 5/15/98.
5/13/98 98-60 Bhachu 1 Bethlehem Steel Corp.
28-8 To fees 5/14/98.
Rtd from fees 5/29/98.
i 5/20/98 98-62 Lee 1 Edwards Systems No model number listed in letter. To fees 5/22/98.
Technology Acknowledgement ltr sent 5/22/98 j
Rtd from fees 5/29/98 6/4/98 98-63 Bhachu 1 Medtronic, Inc.
To fees 6/4/98
)
Returned from fees 6/8/98.
l 6/8/98 98-64 Lee 5 Gamma industnes. Inc. Vanous To fees 6/8/98 i
Returned from Fees 6/10/98.
11 Sealed Source Safety Section l
l l
L __ - _ _____-_ - _-__________ __
Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/13/98 For actions recorded aS of Monday, July 13,1998 Date Assign. #
Received Reviewer Actions Company Model Numbers Status 6/8/98 98 65 i
Lee 4 Gamma industnes, Inc. Vanous To fees 6/8/98.
Returned from Fees 6/10/98.
6/11/98 98-66 Compton 1 Apgee Corporation LB 7400 Senes To Fees 6/11/98.
Returned from Fees 7/8/98.
6/16/98 98-67 Jankovich 1 Department of Health Bolo Tie, Dress Pin To Fees 6/16/98.
Returned from Fees 6/18/98 6/24/98 98-69 Unassigned 1 Kidde Safety Various To fees 6/24/98.
6/24/98 98-68 Unassigned 2 NUMEC AM-CS-1Narious To fees 6/24/98.
Retumed from Fees 7/7/98.
6/29/98 98-70 Unassigned 1 MDS Nordion C-337A To fees 6/29/98.
7/2/98 98-71 Jankovich 2 Ohmart Vega Vanous To Fees 7/2/98.
Returned from Fees 7/8/98.
7/2/98 98-72 Jankovich 1 OhmartNega SHLG Series To fees 7/2/98.
Retumed from Fees 7/8/98.
7/2/98 98-73 Unassigned 1 OhmartNega SHF & SH-1 Senes To fees 7/2/98.
Returned from Fees 7/8/98.
7/2/98 98-74 Unassigned 1 OhmartNega SR Series To fees 7/2/98.
Retumed from Fees 7/8/98.
7/8/98 98-76 Unassigned 1 BSI instruments NW-201, 301,401, 501 Series To Fees 7/11/98.
7/8/98 98-75 Unassigned 1 Maple Chase Company To Fees 7/11/98.
Total Open Case (s)is 94 Totaling 135 Action (s) i 12 Sealed Source Safety Section