Informs That Staff Unable to Determine Which Portions of W Ltr NTD-NRC-95-44400,dtd 950418 to Be Withheld from Public Disclosure.Claim Should Be Reviewed & Staff Should Be Notified as to What Portion Still Considered Proprietary
ML20236Q514
Person / Time
Site: 05200003
Issue date: 07/15/1998
From: Joseph Sebrosky
NRC (Affiliation Not Assigned)
To: Mcintyre B
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
References
NUDOCS 9807200312
Download: ML20236Q514 (2)


Text

- _ _ - - _ _

July 15,1998-

~

Mr. Brian A. McIntyre, Manager Advanced Plant Safety and Licensing Energy Systems Business Unit Westinghouse Electric Company P.O. Box 355 Pittsburgh, PA - 15230-0355 -

SUBJECT:

~ REQUEST FOR WITHHOLDING PROPRIETARY INFORMATION FOR WESTINGHOUSE LETTERS DATED APRIL 18,1995

Dear Mr. McIntyre:

~ By Westinghouse letter NTD-NRC-95-4440, dated April 18,1995, you submitted a -

MAAP4/RELAP comparison for the AP600 in response to a staff request for additional information. The attached affidavit (AW-95-813) executed by you on April 18,1995, indicates that Westinghouse considers some of the materialin this response proprietary.

We have reviewed the subject materialin accordance with the requirements of 10 CFR 2.790, however, the staffis not able to determine which portions of the material Westinghouse wishes to be withheld from public disclosure. Specifically, the cover letter indicates that Enclosure 2 is a non-proprietary version of Enclosure 3, however, the staff could not find any portion of the

Enclosures marked as proprietary. The conventional bracketed-superscript notation also appears to be missing. Further, the staff could not determine which part of the material enclosed with the letter was Enclosure 1,2, or 3.

You are requested to review your claim and to notify the staff of what portions of the material, if any, are still considered company proprietary. If the information is not received, we intend to place the subject document in the NRC Public Document Room in 30 days from the date of this letter. If within thirty (30) days of this letter, you request withdrawal of these documents in accordance with 10 CFR Section 2.790(c), or provide additional reasons for the withholding of information from the documents enclosed, your request will be considered in light of applicable statutes and regulations and a determination made whether the documents will be withheld from public disclosure or retumed to you.

Sincerely, original signed Joseph M. Sebrosky, roject Manager 9007200312 980715 Standardization Project Directorate

{DR ADOCK 05200003 Division of Reactor Program Management PDR Office of Nuclear Reactor Regulation -

Docket No.52-003 cc: See next page

' DISTRIBUTION:

^

Docket File PDST R/F '

TQuay PUBLIC-1 N_ DScaletti JNWilson M

WHuffman. I ACRS (11) l JSebrosky f

JMoore,0-15 B18 MPSiemien,0-15 B18 DOCUMENT NAME: A:RJT_WCP4.PRP

To receive a ces r of thle docunient, teiecate he the ben:

"C" = Copy without ettechment/ enclosure

'E' = Copy with attachment / enclosure "N" = No copy OFFICE.

PM:PDST:DRPM OGC

,l/4 PDST:DRPM._. l c-l l

NAME JMSebrosky:srMF TAPSiemien- @ TRQuay (NW DATE-07/l4 /98 -

'/

07/P\\/98 07/ IS /98

\\

OFFICIAL RECORD COPY-1

i Mr. Brian A. McIntyre Docket No.52-003 Westinghouse Electric Corporation AP600 cc:

Mr. Nicholas J. Liparulo, Manager Mr. Russ Bell l

Nuclear Safety and Regulatory Analysis Senior Project Manager, Programs Nuclear and Advanced Tech 9 ology Division Nuclear Energy Institute l

Westinghouse Electric Correlation 1776 i Stre et, NW P.O. Box 355 Suite 300 l

l Pittsburgh, PA 15230 '

WasF,ington, DC 20006-3706 Ms. Cindy L Haag Ms. L/nn Connor Advanced Plant Safety & Licensing Doc-Se0rch Associates Westinghouse Electric Corporation Post Offics Box 34 l-Energy Systems Business Unit Cabin John, MD 20818 l

Box 355 Pittsburgh, PA 15230 Dr. Craig D. Sawyer, Maneger Advanced Reactor Programs Mr. Storiing Franks GE Nuclear Energy U.S. Department of Energy 175 Curtner Avenue, MC-754 NE-50 San Jose, CA 95125 19901 Germantown Road Germantown, MD 20874 Mr. ' Robert H. Buchholz i

GE Nuclear Energy -

Mr. Frank A. Ross 175 Curtner Avenue, MC-781 l

U.S. Department of Energy, NE-42 San Jose, CA 95125 Office of LWR Safety and Technology 19901 Germantown Road Barton Z. Cowan, Esq.

Germantown, MD 20874 Eckert Seamans Cherin & Mellott 600 Grant Street 42nd Floor Mr. Charles Thompson, Nuclear Engineer Pittsburgh, PA 15219 I

AP600 Certification NE-50 Mr. Ed Rodwell, Manager 19901 Germantown Road PWR Design Certification Germantown, MD 20874 Electric Power Research Institute 3412 Hillview Avenue i

Mr. Robert Maiers, P.E.

Palo Alto, CA 94303 Pennsylvania Department of Environmental Protection i

Bureau of Radiation Protection Rachel Carson State Office Building P.O. Box 8469 Harrisburg, PA 17105-8469

_______a