h TRANSNUCLEAR, INC.
May 14,1998 Mrs. Gloria Bennington D.h F GMd Division of Safeguards and Transponation gg47gg U.S. Nuclear Regulatory Commission Washington, DC 20555 h:
Transnuclear reference 98036-6 Advance notification for an impon shipment of nuclear material from countries that are not party to the Convention on the Physical Protection of Nuclear Material
Dear Mrs. Bennington:
i This letter constitutes Transnuclear Inc.'s advance notification to the USNRC in compliance with the requirements as outlined in 10 CFR 73.74(a)(1)(2) for an import shipment oflow I
strategic significance material from Countries that are not party to the Convention on the Physical Protection of Nuclear Material.
Details of this shipment as required in 10 CFR 73.74(a)(1) are as follows:
)
73.74(a)(3)(i) Data:
Shinning Facility Receiving Facility-COGEMA Pierrelatte Siemens Power Corporation i
B.P.16 2101 Horn Rapids Road 26700 Pierrelatte, France Richinnd, WA 99352-01320 33 7550 4000 509-375-8202 Trancnort Coordinnfor:
Crrrierr Transnuclear, Inc.
Atlantic Container Lines 4 Skyline Drive 50 Cragwood Road Hawthorne, NY 10532 S. Plainfield, NI 07080 hg 914-347-2345 908-668-5556 and t
Tmnorter of Record:
Advanced Distribution Systems 4
COG N,h.
S. 2329 Hayden Road 7401 Wisconsin Avenue Spokane, WA 99204 Bethesda, MD 20814 1-800-756-0223 301-986-8585 9807200246 980514 M
PDR ADOCK 07001426
- 1 C
PDR m
FOUR SKYLINE DRIVE
- HAWTHORNE, NEW YORK 10532-2176 i
' [j()()( 7 TELEPHONE: 914 347-2345 + FAX: 914-347-2346 N
j L
- n: av 4
4 oSMTeg Page 2 of 2 TNY 98036-6 May 14,1998 73.74(a)(3)(ii) Data: Physical description of shipment:
i Seven model 30B cylinders inside overpacks containing-RQ, URANIUM HEXAFLUORIDE, FISSILE (containing more than 1% U235), 7, 1
UN2977, Radioactive Material (U235,U238) solid, UF6. Approximate UF6 weight: 14,418 kgs. Approximate U weight: 9,751 kgs enriched to max. 4.85%. Approximate weight U235: 473 kgs -
73.74(a)(3)(iii)(iv)(v) Data:
MODE ORIGIN (0), TRANSFER (T),
ROUTE DATE/ TIME OF ARRIVAL COUNTRY /ENROUTE(C/E)&
(A) & DEPARTURE (D) AT EACH POINT DESTINATION (D) POINTS Rail Pierrelatte, FRANCE standard rail (D)
June 8,1998 0800 - 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br /> Ocean.
Antwerp, BELGIUM standard ocean (A/D) June 9 - 10,1998 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Liverpool, ENGLAND (A/D) June 13, 1998 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Halifax, CANADA (A/D) June 21,1998 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Port Elizabeth, NJ (A/D) June 23,1998 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> i
\\
(A/D) June 25,1998' Baltimore, MD 0800 - 2359 bours Portsmouth, VA (A)
June 26,1998 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Arnval at the receivmg facihty is estimated to be between U/uo hours and 15UU hours on July 1-2,1998.
This sW =e will meet the levels of physical protection specified in Appendix E (Annex I).
i Yours truly, Transnuclear, Inc.
MN Joan McLaughlin Traffic Coordinator TOTAL P.02
-