ML20236Q202

From kanterella
Jump to navigation Jump to search
Rev 1 to Advance Notification of Import Shipment of Five Trigia-I Shipping container:USA/9034/AF-85,rev 11 RQ, Radioactive Matl fissile,nos,7,UN2918 (U235) Solid,U Metal, Estimated Weight U235:0.97148 Kg
ML20236Q202
Person / Time
Site: 07001426
Issue date: 06/17/1998
From: George M
TRANSNUCLEAR, INC.
To: Bennington G
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
TNY-98030-36, NUDOCS 9807200064
Download: ML20236Q202 (2)


Text

-._ - - - -

2/P Qo-/4R6 dS / 3g_/

TRANSNUCLEAR, ING.

h-[

June 17,1998 l

Mrs. Gloria Bennington bb Division of Safeguards and Transportation T'o cog &ECT c/ @

U.S. Nuclear Regulatory Commission D(3 - 9 (

Washington, DC 20555 Re:

Transnuclear reference: TNY 98030 $

l Advance nouncanon for an impon shipment of nuclear material from countries that are not party to the Convention on the Physical Protection of Nuclear Material This letter constitutes Transnuclear Inc.'s advance notification to the USNRC in compliance l

with the requirements as outlined in 10 CFR 73.74(a)(1)(2) for an import shipment of low l

strategic significance material from Countries that are not party to the Convention on the Physical Protection of Nuclear Material.

l Details of this shipment as required in 10 CFR 73.74(a)(1) are as follows:

73.74(a)(3)(i) Data:

Importer of Record Receiving Facility l

General Atomics McClellen Air Force Base 3550 General Atomics Ct.

5335 Price Avenue - Bldg 258 San Diego, CA Sacramento, CA 619-457-8850 916-643-1024 Shipping Facility Air Carriers CERCA ROMANS Air France e/o Triga International 1 Square Max Hymans Usine Des Berauds 75015 Paris, France 26104 Romans, Isere, France 01 43 23 81 81 l

Transport Coordinator Inland Truck Carrier Transnuclear, Inc.

Roadway Express Four Skyline Drive (Time Critical Services)

Hawthorne, NY 10532 1077 Gorge p

914/347-2345 Akron OH 44310 l

1-888-550-9800

/

i 9807200064 980617 PDR ADOCK 07001426 C

PDR 3

p0 FOUR SKYLINE DRIVE

,1....,.

...P.., a.z. a..

051378-(

j TRANSNUCLEAR, INC.

Page 2 of 2

.[

TNY 98030-3a June 17,1998 73.74(a)(3)(ii) Data: Physical description of shipment:

Five Trigia-1 shipping container: USA /9034/AF-85, Rev.11 RQ, Radioactive Material, Fissile, NOS, 7, UN2918 (U235) solid, U metal. Estimated uranium weight: 4.91809 kg enriched to 19.75% U235.

Estimated weight U235: 0.97148 kg.

1 73.74(a)(3)(iii)(iv)(v) Data:

MODE ORIGIN (0), TRANSFER (T),

ROUTE DATE/ TIME OF ARIm'AL COUNTRY /ENROUTE(C/E)&

(A) & DEPARTURE (D) AT I

DESTINATION (D) POINTS EACH POINT Rail Romans, FRANCE (O) standard (D) May 14,1998 truck / rail 0800 - 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br /> j

Airfreight Paris, FRANCE (T) standard air (A) May 15,1998 via " Air 1345 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> France" (D) June 20,1998 Miami, Florida Standard truck (A) June 20,1998 1825 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> (D) June 22.1998 l

0800 - 1700 hrs l

Sacramento, California, USA (A) June 29,1998 0700- 1700 hrs Arrival at the receiving facility is estimated to be between DE00 hours and 1600 hours0.0185 days <br />0.444 hours <br />0.00265 weeks <br />6.088e-4 months <br /> June, 29,1998 depending on the Customs clearance.

This shipment will meet the levels of physical protection specified in Appendix E (Annex I).

Yours truly, Transnuclear, Inc.

D Mathew George j

Traffic Coordinator FOUR SKYLINE DRIVE. HAWTHORNE, NEW YORK 10532 2176 TELEPHONE:914 347 2345 FAX:914 347 2346 TOTAL P.02