Serving The Best Location in the Nation PERRY NUCLEAR POWER PLANT Al Kaplan i
vics parslDENT j
NUCLEAR OPERAtlONS DIVI $loN Hovember 2, 1987 i
PY-CZI/OEPA-0049 L Mr. Martin.Hilovsky
]
Environmental Scientiot j
Ohio EPA, Northeast District Of fice i
2001 East Aurora Road Twinsburg, Ohio 44087
Dear Mr. Hilovksy:
I In accordance with Part III, paragraph 12. A. of OEPA Permit No. 31B00016*CD, j
this notification of a reportable occurrence during the month of October 1987
^
is hereby submitted.
Outfall No.
Plant Discharge Location Parameter Discharge-Limit D5te 31B00016001 Perry Neut. Basin pH 5.6 SU 6.0 SU 10/7/87 q
Perry I
The Perry Regenerate-Neutralization basin outfall was below the minimum
(
allowable limit for pH during discharge.
The pH dropped to 5.6 SU shortly af ter start of discharge which began at '1750 hours0.0203 days <br />0.486 hours <br />0.00289 weeks <br />6.65875e-4 months <br /> on October 7,1987 and i
remained at an average value of 5.7 SU for the entire discharge lasting i
approximately 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> and 30 minutes. The automatic shutdown feature designed to trip the pump on low pH of 6.5 SU f ailed to trip the. pump. The cause of the pH exceedance is not known.
Subsequent testing of the trip feature indicated
]
that the trip functions properly.
A possible cause may have been an improper j
setpoint on the low pH trip at the time of discharge. This condition was not noticed until the log sheets were reviewed on C.:tober 29, 1987. The responsible technician is being counseled and retrained to highlight any out-of-spec analytical results and immediately notify his supervisor of such an If you have any questions or require further information, please event.
contact me.
I Sincerely.