n JUN 2 6 1975 1
i Mr. Charles M. Hardin, Manager
~
.z Radiation Control Branch r
Bureau for Health Services Department for Human Resources Frankfort, Kentucky 40601 i
Dear Chuck:
This is in response to your May 23, 1975' request for an evaluation of the 1
potential release limits for the evaporator at Maxey Flats.
An evaluation was carried out based on.the 7_-4aeton meteorological data enclosed with your latter. The annual average X/Q at 0.5 miles NNE (the j
3 nearest residence) was calculated to be 10-5 sec/m. At a distance of
]
200 meters NNE (the fence at the restricted area boundary) the X/Q is 104 l
j The estimated permissible stack release rates based on MFC levels for l
tritium, plutonium-239, and strontium-90 at these two locations are attached.
Please note that the meteorological data for the Lexington area may not closal.y approximate the actual meteorological conditions at the site.
{
However, the staff believes that the evaluation which hae been conducted I
should provide a conservative estimate fqr. release rate limits based on the data you provided. We recosmond that you use these values on an
{
. interim basis until a thorough meteorological analysis of the site can be i
performed. We will be pleased to conduct a further evaluation of release
}
l Jimits based on the actual site meteorology.
j I
If you have any questions, please call me.
I I
Sincerely, Nginal Signed By 'IN
{
G. Wayne Kerr, Chief
{
Distribution:
Agreernents and Exports Brancli PHLohaus Division oDiaterials and JSBland Fuel Cycle Facility Licensing NMSS: R/F v..G. Wayne Earr, Chief ty,,
...gy; AE R/F"
- j "tl' y " #M O Agreements and Exports Branch'
~ ~ ~ ~
q ' gentral g"las.g ' ', ' '
' M k h N f Division of Materials and f'
Fuel' Cycle Facility Licensing j
Enclosure:
Release Rates B708070086 870724..
~
\\
MINTONB7-235 PDR
\\
\\,-
M.
omes >
PHLo'haus/hkr-JSBlan -
er avaaa== >
.6125/75.
6BTI.75..:
s 75
.m >
F3rm ABC 318 (Rev. 9 53) AB(M 0240 ku. e4 eovenmuswv paiemme orricas so?4.ese see
.DZZd7. Z7C'20Y'O~2'O
- NOJ.32CT,.a c.!ZCZi~2.UZffiZI,~k'ddl.fC2~'CC u
.m J!!CC.s.CZ Y