Application for Amend to License NPF-56,changing Tech Specs to Relocate Triaxial Seismic Accelerographs 1-SM-XR-6702, 1-SM-XR-6703 & 1-SM-XR-6706
ML20236J378
Person / Time
Site: Seabrook 
Issue date: 10/29/1987
From: George Thomas
PUBLIC SERVICE CO. OF NEW HAMPSHIRE
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML20236J381 List:
References
NYN-87124, NUDOCS 8711060029
Download: ML20236J378 (3)


Text

.

George S. Thomas Vice President Nuclear Production Pubuc Service of New Hampshire N:w Hampshire Yankee Division NYN-87124 October 29, 1987

/

United States Nuclear Regulatory Commission Washington, DC 20555 Attention: Document Control Desk

References:

(a) Facility Operating License NPF-56, Docket No. 50-443 (b) USNRC memorandum dated February 13, 1987, " Forthcoming l

Meeting with Public Service of New Hampshire on Seabrook j

Unit 1", V. Nerses to V. S. Noonan (c) PSNH letter (NYN-87028) dated March 6, 1987, " Proposed l

Technical Specification Changes", G. S. Thomas to 1

T. M. Novak

Subject:

Relocation of Seismic Monitors

)

Gentlemen:

As documented in reference (c), during a meeting between New Hampshire a

Yankee (NHY) and the NRC Staff on February 27, 1987, NHY committed to l

investigate relocating triaxial seismic accelerographs 1-SM-XR-6702 and

]

l-SM-XR-6703.

The proposed new locations for these monitors, as well as i

1-SM-XR-6706, have been discussed with the Staff and have been found to be acceptable. Accordingly, NHY will be relocating these monitors as requested.

I As a result of relocating the instruments, the Seabrook Station Technical l

Specifications will require revision. Proposed changes to the applicabic l

Technical Specifications are provided as Enclosure 1.

We request that these

]

changes be incorporated into the Technical Specifications issued with the next j

amendment of the Seabrook Station operating license. Additionally, as a result of this change, the revision to Technical Specification 3.3.3.3 which l

was discussed in the above referenced meeting and shown in Enclosure 2 will l

not be necessary.

l The af f ected seismic monitors are required by Technical Specifications to be OPERABLE at all times. As a result of their relocation, NHY will submit a special report as required by Specification 3.3.3.3 indicating that the j

monitors, although capable of performing their intended function, are inoper-

{

able and that they will be returned to operable status upon issuance' of the revised Technical Specifications.

k p

p s\\

i l'

P.O. Box 300. Seabrook, NH 03874. Telephone (603) 474-9574

l United States Nuclear Regulatory Commission October 29, 1987 Attention: Document Control Desk Page 2

]

l

~If you have any questions, regarding this matter, please. contact Mr. Richard Belanger at (603) 474-9574,. extension 4048.

j

1 Very truly yours, j

-i l

> tor homas Enclosures cc:

Mr. William T. Russell

~ Regional Administrator l

Region ~7 United States Nuclear Regulatory Commission l

631 Park Avenue j

l King of Prussia, PA 19406 1

t

. :(

Mr. Antone C. Cerne

'l NRC Senior Resident Inspector I

Seabrook Station I

Seabrook, NH 03874 I

i l

l

~ ' ' - ~ - ~ ~


_--_____,.]

' Ii h

]'_

_,j,, *

-pi q 4 t

y.g 'z '

,1 pt - c

.'l

\\

h, i

33..,,.5.-.

' J :'b ',

e j '; q$;'r.

r

.a v

" hhA 2^

y.

t

,, g_y f

9 a )$ -

4

~ 1 I

f

[

I

'f

' i J

1 l

\\

i I

1 4

l j

i

'1 1

I i

)

' ENCLOSURE'1 TO NYN 87124

- li l

J 5

\\

\\

u

_ - -.. -. - _ _. _ - - - - - - - - _ _ - - - -. _ _ _ - - - - - - _ _