__

Mr. Mutin L. Bowling, Jr.

July 1, 1998 Ricovity Officer - Tschnicci Ssrvicss

(-

- N:rth31st Nuclxr Entrgy Company c/o Ms. Patricia A. Loftus Director-Regulatory Affairs P.' O. Box 128 Waterford, Connecticut 06385

SUBJECT:

MILLSTONE NUCLEAR POWER STATION, UNIT 3 - ENGINEERED SAFETY l

FEATURES BUILDING SUMP PUMPING SUBSYSTEM (TAC NO. MA1379)

Dear Mr. Bowling:

In a April 1,1998, letter, Northeast Nuclear Energy Company (NNECO) requested a license -

amendment to revise the Millstone Unit 3 licensing basis by adding a new sump pump subsystem to address groundwater inleakage through the containment basemat.

In order for the staff to complete its review, the staff requires additional information regarding the qualification of the new sump pumps. During the onsite NRC review of your operability determination associated with the new sump pump subsystem, the staff reviewed a vendors test report on the qualification of the sump pumps, which was prepared for Northeast Utilities. Please provide the complete test report in order for the staff to complete its review of your license amendment request. Please respond to this request for additionalinformation as soon as l possible..

Should you have any questions, please contact me at (301) 415-1437.

Sincerely, Original signed by:

James W. Andersen, Project Manager Special Projects Office - Licensing 3

Office of Nuclear Reactor Regulation

)

!)

Docket No. 50-423

~

See next page

- cc:

DISTRIBUTION.

g M3 ACRS PUBLIC JDurr, RI h

4 a

SPO-L Rsading OGC SPO Reading DScrenci, RI.

WTravers PMcKee LBerry j

. JAndersen j

DOCUMENT NAME: G:MNDERSENM1379-2.RAI 1

- Ta receive a copy of this document, indicate in the box: "C" = Copy without enc @es *E" = Copy with enclosures *N" = No copy 0FFICE SPO-L PM /

SPO-L:LA{ QWSP @ID l

NAME JAndersen - AF

LBerry, X(A P&dK'ee DATE 06/30 /98 06/7C/98

($/ l /98 OFFICIAL RECORD COPY

~ < -wwmefpQ

,e g.

]

Y l

P PDR h

n

,[ f ry t

UNITED STATES s

j NUCLEAR REGULATORY COMMISSION

/g WASHINGTON, D.C. 30666 4 001 g

July 1, 1998 Mr. Martin L. Bowling, Jr.

Recovery Officer - Technical Services Northeast Nuclear Energy Company c/o Ms. Patricia A. Loftus Director-Regulatory Affairs P. O. Box 128 Waterford, Connecticut 06385

SUBJECT:

MILLSTONE NUCLEAR POWER STATION, UNIT 3 - ENGINEERED SAFETY FEATURES BUILDING SUMP PUMPlNG SUBSYSTEM (TAC NO. MA1379)

Dear Mr. Bowling:

In a April 1,1998, letter, Northeast Nuclear Energy Company (NNECO) requested a license amendment to revise the Millstone Unit 3 licensing basis by adding a new sump pump subsystem to address groundwaterinleakage through the containment basemat.

In order for the staff to complete its review, the staff requires additional information regarding the qualification of the new sump pumps. During the onsite NRC review of your operability determination associated with the new sump pump subsystem, the staff reviewed a vendor's test report on the qualification of the sump pumps, which was prepared for Northeast Utilities. Please provide the complete test report in order for the staff to complete its review of your license amendment request. Please respond to this request for additionalinformation as soon as possible.

Should you have any questions, please contact me at (301) 415-1437.

)

Sincerely, l

l l

1 me.; W. Andersen, Project Manager Special Projects Office - Licensing Office of Nuclear Reactor Regulation 3

I Docket No. 50-423 l

cc: See next page l

l l

i

Millstone Nucle:r Power Stati:n

,k

. Unit 3 I

i i

cc:

Lillian M. Cuoco, Esquire Joseph R. Egan, Esquire Senior Nuclear Counsel-Egan & Associates, P.C.

Northeast Utilities Service Company 2300 N Street, NW P. O. Box 270 Washington, DC 20037 Hartford, CT 06141-0270 Mr. F. C. Rothen Mr. Kevin T. A. McCarthy, Director Vice President - Work Services Monitoring and Radiation Division Northeast Utilities Service Company 1

' Department of Environmental Protection P. O. Box 128 79 Elm Street Waterford, CT 06385 Hartford, CT 06106-5127 Emest C. Hadley, Esquire Regional Administrator, Region i 1040 B Main Street U.S. Nuclear Regulatory Commission P.O. Box 549 475 Allendale Road West Wareham, MA 02576 King of Prussia, PA 19406 Mr. John Buckingham First Selectmen Department of Public Utility Control Town of Waterford Electric Unit Hall of Records 10 Liberty Square 200 Boston Post Road New Britain, CT 06051 Waterford, CT 06385.

Mr. James S. Robinson, Manager Mr. Wayne D. Lanning.

NuclearInvestments and Administration Deputy Director of Inspections.

New England Power Company Special Projects Office 25 Research Drive J

475 Allendale Road Westborough, MA 01582

)

King of Prussia, PA 19406-1415 i

Mr. John Streeter Mr. M. H. Brothers Recovery Officer - Nuclear Oversight Vice President - Millstone Unit 3 Northeast Utilities Service Company Northeast Nuclear Energy Company P. O. Box 128 P.O. Box 128 Waterford, CT 06385 Waterford, CT 06385 Deborah Katz, President Mr. M. R. Scully, Executive Director Citizens Awareness Network Connecticut Municipal Electric P.O. Box 83 Energy Cooperative Shelbume Falls, MA 03170 30 Stott Avenue Norwich, CT 06360 Mr. Allan Johanson, Assistant Director Office of Policy and Management Mr. David Amerine Policy Development and Planning Vice President-Human Services Division Northeast Utilities Service Company 450 Capitol Avenue - MS# 52ERN i

P. O. Box 128 -

P. O. Box 341441 i

. aterford, CT 06385 Hartford, CT 06134-1441 W

4 I

I j

9 Millstone Nucle:r Power Str.ti:n Unit 3 Mr. William D. Meinert Nuclear Engineer cc:

Massachusetts Municipal Wholesale The Honorable Terry Concannon Electric Company Nuclear Energy Advisory Council P.O. Box 426 Room 4035 Ludlow, MA 01056 Legislative Office Building Capitol Avenue Attomey Nicholas J. Scobbo, Jr.

. Hartford, CT 06106 Ferriter, Scobbo, Caruso, Rodophele, PC 1 Beacon Street,11th Floor Mr. Evan W. Woollacott -

Boston, MA 02108 Co-Chair Nuclear Energy Advisory Council Citizens Regulatory Commission

.128 Terry's Plain Road ATTN: Ms. Susan Perry Luxton Simsbury, CT 06070 180 Great Neck Road Waterford, CT 06385 Mr. John W. Beck, President Little Harbor Consultants, Inc.

Millstone -ITPOP Project Office P.O. Box 0630 Niantic, CT 06357-0630 Mr. B. D. Kenyon (Acting)

Chief Nuclear Officer-Millstone Northeast Nuclear Energy Company P.O. Box 128 Waterford, CT 06385 Mr. Dar lel L Curry Project Director Parsons Power Group Inc.

2675 Morgantown Road Reading, PA 19607 Mr. Don Schopfer Verification Team Manager Sargent & Lundy.

55 E. Monroe Street Chicago,IL 60603 Mr. P. D. Hinnenkamp Director-Unit 3 Northeast Nuclear Energy Company P.O. Box 128.

Waterford, CT 06385 Senior Resident inspector Millstone Nuclear Power Station c/o U.S. Nuclear Regulatory Commission P. O. Box 513 Niantic, CT 06357 I

h