, pm mum-mmmmmmmmmEA7f5ErE7/fRE5iLWA*M*m AKEAEATEMNTXXXJtNNAWmWEAW[
I N
U.S. NUCLEAR REGULATORY COMMISSION NRC FOR'181 5
<so CERTIFICATE OF COMPLIANCE I
l fi to cFa 7i FOR RADIOACTIVE MATERIALS PACKAGES 1 a CERTIFICATE NUMBER b REVISION NUMBER
- c. PACKAGE IDENTIFICATION NUMBER d PAGE NUMBER e TOT AL NUMBER PAGES l
6188 4
USA /6188/B( )F 1
2
![
l h
2 PREAMBLE a This certificate is issved to certif y that the packaging and contents described in ue m 5 below. meets the apphcable safet y standards set forth in Titie 10, Code
[
]
of Federal Regulations. Pa" 71. ' Packaging and Transportation of Radioactive Matenal" I
l
[
b Th 6 certificate does not reheve the consignor 4crn comphance with any requirement o' the regulations of the U S Decartment of Transportation or other G
apphcabie reguiatory agencies, including ine government of any country inrouan or mio which tne pac
- age witi be transported 3
E n
' 'MsEE*J,' '.!*,'fff, " '"' *** ' ' ""**"*'S
- '7tE fMIo'eU'ECff 8N Mee"oNENEECATioN
^ ' '
J oT
(
Il g
U.S. Department of Energy Safety Analysis Report for 25.0 Spare
,[;
W Division of Naval Reactors Module Shipping Container doted N
Washington, DC 20585 February 6, 1969, as supplemented.
i P[!
8 W
- c. ooCxET NUuBER 71-6188 j
4 CONDIT!ONS This certificate is conditional upon fulfithng the requirements of 10 CFR Part 71. as apphcable, and the conditions specified below t J i -]
WI dj 5
il i
d i3
- j (a) Packaging j
i ld q
4 s
j ]!
g (1) Model No.: 25.0 Spare Module 4
l (2) Description N
- i The container, constructed of 1/8-inch carbon steel plate, is f
g[
circular in cross section, 40 inches diameter, and approximately 360 g
g!
inches long.
It has a removable upper half shell employing a f)
Ig!
stainless steel closure flange with a rubber 0-ring gasket for F
1
(
sealing. The four main handling points of the container are located h
i Eil Wl on the sides at the container base.
Steel skids run the full length of the container.
Each fuel module to be transported is clamped f
[i into a removable trough-shaped strongback which is shock mounted to
.gj gg the interior of the lower shell.
The flanged carbon steel strongback b.
k with its stainless steel liner is 323 inches lono having holes at b
l K
regular intervals with stamped station numbers identifying those holes 1 E
R:
to be used in clamping a particular fuel module.
Each fuel module type
,j has its own clamping arrangement; some clamps will not be in use and j l
l are stored within the container. When a fuel module is installed in 9
q l
g the sealed container, the container is purged and pressurized with dry O g
nitrogen gas. Maximum weight of loaded container is approximately T
4l 10,680 lbs.
- I N
I f'
f{!?
(3) Drawings l
The packaging is constructed in accordance with Westinghouse Electric h g
Corporation Drawing hos. 901E851, Rev. 1s Sheet 1 thru 9 of 9 and b
l 901E440, Rev. 2, Sheet 1 thru 9 of 9.
lt!ti i
!r I
'I:
4 lE; g.
p
(
.t' Qao$ock b l
C i
tk--w rr5m === = = = - - - - - - - - --- ------ ---- -- --- ---- - --- ---- d
~
mammmmm--_mm Laae--mMmm,,,s
,,e
- & >,, s > s ), -> r i,, ' e,,. s,w e,,,es; ;7 C NolTlSNS (continu:d)
Page 2 - Certificate No. 6188 - Revision No. 4 - Docket No. 71-6188 5.
(b) Contents i
I (1) Type and form of material I
,1 Unirradiated fuel assemblies of the following type, h
(i) A1W-3 new fuel module with control rod and. upper control rod y
drive mechanism installed.
I I
(ii) Partial A1W-3 new fuel module with poison rods as shown on I
Westinghouse Electric L poration Drawing No. 927J942, Rev.1 l
and poison rod lock-in device as shown on Wes'inghouse Electric i
Corporation Drawing No. 938F030, Rev. 2.
I
?,. n I
(2) Maximum quantity;of~ material'per, package.
v I
1 (1) Onefuelassemblyasdescribedib'5(b)(1)(i).
l (ii)Two'fuelassembliesasdescribed'in5(b)(1)(ii).
i I
(c) Fissile Class III i
l Maximum number of packages per shipment nine (9) k 6.
Expiration date: July 31, 1992.
M M
N REFERENCES W
f Safety Analysis Report for 25.0 Spare Module Shipping Container, WAPD-0P(R)SS-1156 j
dated February 6, 1969.
~ '
s i
Supplements: Bettis Atomic Power Laboratory letters WAPD-0P(R)SS-1107 dated October i
21, 1968, WAPD-0P(R)SS-1333 dated July 3, 1969 and WAPD-0P(R)SS-1530 dated December W
10, 1969.
W l
FOR THE U.S. NUCLEAR REGULATORY COMMISSION 4i hk l
Charles E. MacDonald, Chief Transportation Branch y
Division of Safeguards and i
Transportation, NMSS I
JUL 8 01987 i
Date:
e a
6
\\
H
(
i I
I 1
l l!-------s--------------##_w___________,,____,,,__,,-,,,,,,,,,I
$9 jo,,
UNITED STATES
[
g NUCLEAR REGULATORY COMMISSION wAss NGTON, D. C. 20055 g
j
\\...../
Transportation Branch Ap3roval Record Model No. 25.0 5)are Module-Packaging Docket 10. 71-6188 Revision No. 4 By application dated June 25, 1987 (G# 87-1684), Division of Naval Reactors, U.S. Department of Energy, requested renewal of Certificate of Compliance No. 6188. No changes have been authorized to the package design since approval of latest supplement dated December 10, 1969.
The certificate of compliance has been renewed for a five year term which expires July 31, 1992.
b Charles E. MacDonald, Chief Transportation Branch Division of Safeguards and g gg g Transportation, NMSS Date: