GE Nuclear Energy GeneralElectnc Company kollecitos Nuckar Center PO Box 460 ValkotosRoad Pleasanton. CA 94S66 June 24,1998 Mr. Cass R. Chappell, Section Chief Package Certification Section

' Spent Fuel Project Office Office of Nuclear Materials Safety and Safeguards U.S. Nuclear Regulatory Commission

= Washington, D.C. 20555-0001

References:

(1) Certificate of Compliance No. 9228, Docket 71-9228.

(2) Letter from B.M. Murray to C.R. Chappell dated May 15,1998.

(3) Fax sheet from Joe Tengco, Parker Seals, to Raul Pomares dated June 23,1998.

Dear Mr. Chappell:

This letter is in response to our telephone conversation of June 23,1998, wherein GE committed to -

- determine the manufacturer's recom' mended load required to assure sceling of the lid gasket of the

- Model 2000 shipping cask (Certificate of Compliance 9228). The gasket manufacturer, Parker e'

liannifin Corporation, has calculated the load required to fully compress the elastomeric material'of

)

the Parker Gask-O-Seal (compound No. E1823-75) between the lid and the body of the Model 2000 cask. The range of the unit load necessary to compress the seal compound used in the gasket is from ~ /

10 to 30 pounds per inch of seal. The maximum load required for compression of the Model 2000

/

gasket is 5,511 pounds (minimum to maximum range = 1,837 to 5,511 pounds). The GE calculated axial load for gasket seating (30,310 pounds) presented in the submittal (Ref. 2) was determined by following the guidelines of NUREG/CR-6007, which recommends the procedure of the ASME Code

Section 111, Appendix E. The preload (36,800 pounds) equivalent to the specified bolt torque of 690 h/

foot-pounds is greater than either of the recommended sealing loads.

A copy of the fax note from Parker presenting the load requirement is attached for reference. If you

. or your staff have any additional questions on this submittal, please contact me at (925) 862-4455.

Very truly yours, B. M. Murray -

)

'. Senior Licensing Engineer 1

...S U '}

.m Attachment 9907020025 990624 I

l' i-PDR ADOCK 07109229 C

l.

pop O

O_ _____-_

a' un-23-CB 0:3 : 5 C A Parker O-Seal 619 671 3202 p.01 Seals FAX COVER SHEET PARKER IIANNIFIN CORP.

O-SEAL DIVISION DATE:

JUNE 23.1998 7664 PANASONIC WAY SAN DIEGO, CA 92173, USA ATTN:

Raul Pomnres JOE TENGCO COMPANY NAME:

GE Vallecitos Product Design Engineer Phone: (619) 671-3225 FAX NUMBER:

925-862-4516 Fax:

(619) 671-3206 E-mail: Jtengco@ parker.com NUMBER OF PAGES INCLUDING THIS SHEET:

1

Raul, The anticipated load for any given installation is not fixed but a range of values. The calculated load for your installation based on 10 -30 lbs/in load is 1837 -5511 lbs. If you have any questions, please feel free to contact rne.

Joe

_ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _