ML20236D672
| ML20236D672 | |
| Person / Time | |
|---|---|
| Site: | 07105894 |
| Issue date: | 07/27/1987 |
| From: | Macdonald C NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | |
| Shared Package | |
| ML20236D670 | List: |
| References | |
| NUDOCS 8707310010 | |
| Download: ML20236D672 (4) | |
Text
.
<mmmmmmmm
.______.____-mm,--____m
___q "E ""
CERTIFICATE OF COMPLIANCE SN R RE RV assioN s
[
io crR 7' FOR RADIOACTIVE MATERIALS PACKAGES 1 a CERTIFICATE NUMBER b REvlSION NUMBER C. PACKAGE IDENTIFICAilON NUMBER d PAGE NUMBER
- e. TOTAL NUMBER PAGES 5894 4
USA /5894/AF 1
3 2 PREAMBLE N
a This certificate is issued to certfly that the packaging and contents described in item 5 below, meets the applicable safety standards set forth in Title 10 Code y
oi rederal ReQufatrons. Part 11. " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Matenal Under Certain Conditions."
b This certificate does not relieve tne consignor frorn compliance with any requirement of the regulations of the U.S Department of Transportation or other i
applicable regulatory agencies, including the government of any Country through or into which the package will be transported.
4 3 THIS CERTIFICATE IS ISSUED ON THE BASIS OF A SAFETY ANALYSIS REPORT OF THE FACKAGE DE$1GN OR APPLICATION a PREPARED BY (Name and Addressa b TITLE AND IDENTIFICATION OF REPORT OR APPLICATION U.S. Department of Energy Safety Analysis Report for 2.7 New Fuel Division of Naval Reactors Shipping Container dated July 15, 1968, g
g Washington, DC 20585 as supplemented.
p c OOCKET NUMBER 71-5894
{4 CONDITIONS r
This certificate is Conditional upon fulfilling the requirements of 10 CFA Part 71, as applicable, and the conditions specified below 3
5 i
A (a) Packaging
't (1) Model No.: 2.7 New Fuel i
l (2) Description The Model No. 2.7 New Fuel container was designed to ship and store new and unirradiated S5W Core R2 fuel nodules. Adapters are used to permit additional shipments of S5W Core R3, A1W Cor R2, and SIC Type H
I fuel modules. The. container assembly consists of two major f
components, an inner container which holds the fuel module and an outer g
container which supports the inner container. The steel outer a
container is approximately 24.5 inches wide by 24.5 inches high and
)
128 inches long.
The cross section of the outer container is octagonal, s1>
the steel shell thichness is 0.1875 inch ASTM A 283 GR.B.
The outer i
shell is surrounded by a framework of steel stiffeners and rails.
,j The inner container is constructed from Type 304 CRES plates, 0.1875
/j inch thick and is 7.76 inches square and 99 inches long.
Bolted closure is provided for each container. The gross weight of the package ranges from approximately 1,500 to 2,000 pounds.
h1 s
)(
l 4
s d
1, e
i i
i 8707310010 B70727
[
i PDR ADOCK 0710 4
1 W
d
- - - - -<= - - - - - i m m a - m,- _, -,,- - _ _,_,,,,_ - _ _. -,,,, z.n.;.m. _,_,,,n,m
, y -1 N
eI CONDITIONS (continusd) k I
Page 2 - Certificate No. 5894 - Revision No. 4 - Docket No. 71-5894
!E I
i I
H (3) Drawing l
I i
i The packaging is constructed in accordance with Westinghouse Electric p
I Corporation Drawing No. 924J152, Rec. 16.
I I
N l
(b) Contents l
1 I
i (1) Type and form of material y
I I
I Unirradiated fuel assemblies of th following type:
i I
i (i) S5W Core R2 standard module or corner module; l
i n
I (ii) SSW Core R3 standard mod.ule.or corner module; I
g l
I (iii) A1W Core R2' standard cluster'o'r half cluster; i
I i
l (iv) SIC Core Type I standard cluster; l
1 ll j
(v) SIC Core Type I fuel subassembly; y
i N
(vi) S5W Core 2 standard module or corner module; E
8 E
l (vii) A1W Core R2 subassembly.
ll 8
N' 3
(2) Maximum quantity of material per package y
i I
(1)
One fuel assembly)as described in 5(b)(1)(1), 5(b)(1)(ii),
5(b)(1)(iii),5(b(1)(iv)or5(b)(1)(vi).
j (ii) Two fuel assemblies as described in 5(b)(1)(v).
j A
y (iii) Four fuel assemblies as described in 5(b)(1)(vii).
m l
(c) Fissile Class III Maximum number of packages per shipment:
y W
(1)
For the contents described in 5(b)(1)(i),
No more than N
E 5(b)(1)(ii),5(b)(1)(iv),5(b)(1)(v),and one total core's i and limited in 5(b)(2)(i) and worth 9
I N
4 i
e i
I E
l h
h i
s 9
l W
!il i'
- W j
t
- E E
i N
1 N
4 W
I -
- - -t----n-r# _ ; -
- .c - ww --
m I
lI CONOlTIONS (continusd) e Page 3 - Certificate No. 5894 - Revision No. 4 - Docket No. 71-5894 I
(2)
For the contents described in 5(b)(1)(iii) 25 total, with the i
and5(b)(1)(vii)andlimitedin5(b)(2)(1) number of packages I
and5(b)(2)(iii):
as described in 1
5(b)(1)(v11)and I
limited in l
5(b)(2)(iii) not to i
exceed four I
I 6.
Expiration date: July 31, 1992 I
I l
REFERENCES I
I Safety Analysis Report for 2.7 New; Fuel:. Shipping Container, WAPD-0P(R)S-2650 dated i
July 15, 1968.
l l
1 Supplements: Bettis Atomic Power Laboratory letters WAPD-0P(R)S-2800 dated September 3,1968 and WAPD-0P(R)S-3425 dated August 14' 1969, and Department of i
Energy letter G# 6291 dated July 13, 1979.
]
i i
FOR THE U.S. NUCLEAR REGULATORY COMMISSION i
l i
I tuDsGLU si Charles E. MacDonald, Chief i
- d Transportation Branch.
l Division of Safeguards and i
M 27 W
. Transportation, NMSS l
Date:
4 4
i N
4 l
t i
e l
k l
Ni n
i l
l 4
il 4
A i
4 4
4 i
N i
l 4
l__
i w. - -r -- -- -- =r - - - - ---w r
-r-r-r. w% g; _ _ _ _ _ - _ _ _ _,_, _,,--- -
,,mi
/pm Mog 'o,,
UNITED STATES 8"'
NUCLEAR REGULATORY COMMISSION qI WASHINGTON, D. C. 20066
%...../
Transportation Branch Approval Record Model No. 2.7 New Fuel Package Docket No. 71-5894 i
Revision No. 4 By application dated June 25, 1987 (G# 87-1684), Division of Naval Reactors.
U.S. Department of Energy, requested renewal of Certificate of Compliance No. 5894.
No changes have been authorized to the package design since approval of the latest supplement dated July 13, 1979.
The certificate of compliance has been renewed for a five year term which expires July 31, 1992.
l
$k lk Charles E.
acDonald, Chief Transportation Branch Division of Safeguards and Transportation, NMSS M 27 g Date:
- _ _ _ _ _ _ _ _ _ _ - _ _ - _ _ - _ - _ _ _ _ _ - _ _ _