ML20236C871

From kanterella
Jump to navigation Jump to search
Forwards Response to Deficiency Identified During 1987 Emergency Preparedness Exercise.Response Also Includes Schedule for Resolution of Deficiency Noted in Insp Rept 50-482/87-21.Corrective Action:Procedure EPP 01-2.1 Revised
ML20236C871
Person / Time
Site: Wolf Creek 
Issue date: 10/21/1987
From: Withers B
WOLF CREEK NUCLEAR OPERATING CORP.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
WM-87-0273, WM-87-273, NUDOCS 8710270375
Download: ML20236C871 (2)


Text

-- _

s LF CREEKos Wi)NUCLEAROPERATING 9

Bart D, WRhers c'n".Nx1'$.omc r October 21, 1987 WM 87-0273 j

U.S. Nuclear Regulatory Commission ATTH: Document Control Desk Washington, D.C.

20555-Subj ect: Docket No. 50-482:

Response to Deficiency in Inspection Report 50-482/87-21 I

n Gentlemen:

Attached is Wolf Creek Nuclear Operating Corporation's responte to a deficiency identified during the 1987 Emergency Preparedness Excercise conducted at the Wolf Creek Generating Station.

The response, which also includes a schedule for resolution of the deficiency, is being submitted in response to Inspection Report 50-482/87-21.

If you have any questions concerning this submittal, please contact me or Mr. O. L. Maynard of my staff.

Very truly yours, V :-

Bart D. Withers President and Chief Executive Officer BDW/llk Attachment 1

cc:

P. W. O'Connor (2)

R. D. Martin C. A. Hackney J. E. Cummins i

Ig,$

2(

P.O. Box 411/ Burtington, KS 66839 / Phone: (316) 364-8831

(

An Equal opportunity Ernployer htF/HC/ VET

s.

' Attachment.to WM 87-0273 October. 21,1987 i

RESPONSE TO DEFICIENCY IDENTIFIED IN INSPECTION REPORT 50-482/87-21' for

. WOLF CREEK GENERATING STATION

" Deficiency 50-482/8721-01 i

Classi fic ation of the emergency was incorrect, considering-the plant parameters'and radiological conditions given to the operators.

-Response During the '1987 Emergency Preparedness Exercise the control-room. staff

.j improperly classified the emergency due to a miscalculation of. five times the Technical ' Speci fication limits for Gross Activity.

A discussion'was

-held with the Shift Supervisor concerning the classification of - the emergenc y.

In addition, a change to procedure EPP 01-2.1 " Emergency l

. Classification" has been initiated to further define the indications that 1

would lead to!. classifying an emergency as an Alert due to breached fuel.

.This procedure change will be implemented by November 16,.1987.