1901 Gratiot Street ^
Post Office Box 149 St Louis. Missouri 63166 314 621-3222
~
UVION ELECTIUC March 10, 1989-f3 U.
S. Nuclear. Regulatory Commission ATTN:
Document Control Desk Washington, D.C.
20555 Gentlemen:
ULNRC - 1939 DOCKET 50-483 CALLAWAY PLANT ADDITIONAL INFORMATION CONCERNING THE CALLAWAY PLANT INSERVICE INSPECTION PROGRAM
Reference:
ULNRC-1753, dated April 11, 1988
~
The referenced letter transmitted Relief Requests G through N to the Callaway Inservice Inspection Program Plan.
These relief requests were submitted as a result of observations made during Callaway Refuel II.
e After further consideration, Union Electric wishes to withdraw Relief Request N.
Union Electric will continue to implement existing programs for snubber inspection and testing.
Please contact us if there are any questions concerning this letter.
Very truly yours, O
i Donald F.
Schnell WEK/cas 0903210166 890310 p0g DR ADOCK 0500 3
1 t
0
t-y :-
- -g cc:1 Gerald Charnoff,' Esq.
Shaw,-Pittman,-Potts & Trowbridge 2300 N.
Street, N.W.
Washington, D.C.-
20037
-Dr.-J. O. Cermak
^CFA, Inc.
4 Professional Drive (Suite 110)
Gaithersburg, MD 20879 R.
C.' Knop Chief, Reactor Project Branch 1 U.S.
Nuclear Regulatory Commission RegionLIII I
799 Roosevelt Road Glen Ellyn,-Illinois 60137 Bruce Little Callaway Resident Office U.S.
Nuclear Regulatory Commission RR91 Steedman, Missouri 65077 Tbm Alexion (2)
Office of Nuclear Reactor Regulation U.S.
Nuclear. Regulatory Commission
)
. Mail Stop 316 j
7920 Norfolk Avenue Bethesda, MD 20014 Manager, Electric Department Missouri Public Service Commission P.O. Box 360 Jefferson City, MO 65102 U.S.
Nuclear Regulatory Commission ATTN:
Document Control Desk Washington, D.C.
20555 i