'LTR LN TECH EW L. N. Technologies Corporation 1501 Key Road Columbia, SC 29201 gap, - G89 Attention: Mr. Regan E. Voit Vice President-Operations
Dear Mr. Voit:
This is to request information about three incidents in which technical discrepancies were found with waste process / containers delivered by L. N.
Technologies Corporation for disposal at the Barnwell site. These incidents occurred on June 6, 1988, October 11, 1988 and October 13, 1988 and are described in the enclosed sumary reports.
Please provide the following information for each incident:
- 1. The cause of the event in more detail than that provided in the summary report.
- 2. The testing that was preformed on the liner after it was returned to the generator.
- 3. The disposition of the waste in the defective liner, e.g., a description of what was done to the defective liner to make it acceptable for burial, the current location of the waste and, if applicable, the date of disposal and the disposal site.
We request that you provide this information within 30 days after receipt of this letter.
Sincerely, Origin::.1 Signed By Michael Tokar, Section Leader j Technical Branch j Division of Low-Level Waste Management and Decommissioning, NMSS I
Enclosure:
As stated DISTRIBUTION:
I Central File-
'NHSS r/f PLohaus LLTB r/f MBell JGreeves JSurmeier n ()
)FC :LLTB g g!LLTB .:LLT : : : :
LAME :EWick/jl :MTokar :JSu e er : : : :
iATE : 8/6 /89 :03/4 /89 :Qf/7/89 : : : :
OFFICIAL RECORD COPY 8903140608 890308 PDR WASTE b'. ,
((1// f 3
. __ - _- - __ _ _ __- _ _-_= . _ _ _.
P. PORT - (JUNE 1, 1988 TO PRESENT)
~
JCIDENT DATE': 06/06/88-iNDOR:
LN TECHNOLOGIES CORPORATION iiSERATOR:
SCILITY: CLEVELAND ELECTRIC ILLUMINATING CO.
PERRY NUCLEAR POWER PLANT, PERRY OH
@ CESS:
QUICK DRY DEWATERING SYSTEM' STEFORM: ,
SOLIDIFIED OXIDES ON DEWATERED POWDERED RESIN AD RATE / ACTIVITY / CLASS: ? / 0.314 mci / A UNSTABLE-CKAGE TYPE: STEEL LINER
@CRIPT. OF INCIDENT: DHEC Inspectors identified a swollen and distended liner-lid due to gas generation. The liner was banned from burial at Barnwell, depressurized, and returned to Perry,-OH for testing. Samples of the gas indicated high concentrations of carbon dioxide and methane present. . It was further determined that strong oxidants.mmy have caused the chemical reaction responsible for this event.- '
SIDENT DATE: 10/11/88 SDOR:
LN TECHNOLOGIES CORPORATION. s SERATOR: NEW YORK POWER AUTHORITY-SILITY: JAMES A. FITZPATRICK NUCLEAR POWER PLANT,LYCOMING NY 2 CESS: LOMI BTEFORM SOLIDIFIED CHEMICAL DECON. RESIN UD RATE / ACTIVITY / CLASS: ? / 17.0 mci / A STABLE SKAGE TYPE: STEEL LINER BCRIPT. OF INCIDENT: DHEC Inspectors performed a punch test on the liner, and encountered a resin bead jelly-like substance which flowed from the hole after 1-2 minutes. The waste also contained 7.6% Picolinic Acid, which in an unsolidified form violates license agreements. The liner was banned from Barnwell, and returned to Lycoming, NY for testing. It was determined that improper mixing of the chemicals caused the jelly-like substance to form on the inner wall of the liner. Chunks of the substance then broke free from the wall during mixing, becoming randomly distributed.throughout the media, forming jelly pockets after solidification.
1 1
i i
1 4
- NCi[ DEN" 'DATE : 10/13/88 TENDOR: LN TECHNOLOGIES CORPORATION 1ENERATOR:
CLEVELAND ELECTRIC ILLUMINATING CO.
'ACILITY: PERRY NUCLEAR POWER PLANT, PERRY OH i
'ROCESS: QUICK DRY DEWATERING SYSTEM TASTEFORM: DEWATERED RESIN
,OAD RATE / ACTIVITY / CLASS: ? / 0.079 mci / A UNSTABLE ,
'ACKAGE TYPE: STEEL LINER iESCRIPT. OF INCIDENT: DHEC Inspectors performed a punch test on the liner, and drained out 5.94 gallons of free liquid. Acceptable limit for a 147 cuFt liner is 5.5 gallons, therefore, the free liquid content in the liner exceeded limits by 0.44 gallons.