Submits Response to Questions Re SER Open Item 16, Spent Fuel Pool Rack Design, Per 870715 Telcon.Westinghouse Verified Impact Load on Fuel Assembly of 3 Gs Acceptable & Grid Damping Value of 25% Developed from WCAP-9401-P-A Data
ML20235Y309
Person / Time
Site: Vogtle 
Issue date: 07/20/1987
From: Bailey J
GEORGIA POWER CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
GN-1386, NUDOCS 8707250194
Download: ML20235Y309 (2)


Text

..

l Georgit Fbwer Comp 1ny i

Ft:t Office Bcx 282 i

W:yn:st:oro, G;orgia 30330 l

T;1 phone 404 554-9961 1

404 724 8114 i

Southem Company Serwces. Inc.

Ibst Office Box 2625 h

Birmingham, Alabama 35202 Telephone 205 670 6011 VOgtie Project July 20, 1987 United States Nuclear Regulatory Commission Document Control Desk File:

X7BC35 Washington, D. C.

20555 Log:

GN-1386 REF:

1) Miller (NRC) to O'Reilly (GPC), dated April 7,1987 2)

J. A. Bailey (GPC) to NRC, dated May 22, 1987 NRC DOCKET NUMBER 50-424 OPERATING LICENSE NPF-68 V0GTLE ELECTRIC GENERATING PLANT - UNIT 1 SER OPEN ITEM 16:

SPENT FUEL P00L RACK DESIGN Gentlemen:

As a result of a July 15, 1987 telecon with members of your staff, Georgia Power Company provides the following responses to the Questions on Spent Fuel Racks for Vogtle Unit 1:

1) The fuel supplier (Westinghouse) has verified that the impact load on a fuel assembly of 3 g's is acceptable. The actual maximum test load is 20 g's.

This data to support this number is contained in internal Westinghouse WCAP's 8286 and 9895.

These WCAP's have not been submitted to the NRC for review but as all fuel design information are available at the Westinghouse location for review.

2) The grid damping value of 25% was developed from data presented in the approved WCAP 9401-P-A.

Pages 3-26 to 3-31 explain the derivation of the grid damping value.

Further explanation is contained in the response to NRC Question 13 in the WCAP supplement.

Although the 25% critical damping value is not explicitly called out in the WCAP, the data to support this value is.

Should you require additional information, please inquire.

Sincerely.

h-J. A. Bailey Project Licensing Manager JAB /wkl xc: See Next Page o

B707250194 B70720 gDR ADOCK 0500g4 gO

SER Open Item 16:

Spent Fuel Pool Rack Design File:

X7BC35 Log:

GN-1386 July 20, 1987 Page two j

xc:

NRC Regional Administrator NRC Resident Inspector J. P. O'Reilly R. E. Conway L. T. Gucwa R. A. Thomas J. E. Joiner, Esquire B. W. Churchill, Esquire M. A. Miller (2)