_ - _

nc l

l July 20, 1987 NRC/TMI-87-055 l

7 i

MEMORANDUM FOR:

Dennis M. Crutchfield, Director Division of Reactor Projects - III,IV.V & Special Projects l

l Frank Schroeder, Jr.. Assistant Director Region IV Reactors and Special Projects l

FROFi:

William D. Travers, Director TMI-2 Cleanup Project Directorate

SUBJECT:

KRC TMI-2 CLEANUP PROJECT DIRECTORATE WEEKLY STATUS REPORT FOR JULY 13 - 19, 1987 1.

DEFUELING j

i Pick and place defueling of partial length fuel assemblies and fuel pins continued. Partial fuel assemblies E-3, F-2. F-3, F-4, G-3, 6-4, and G-5 were loaded into defueling canisters. A total of 52 I

fuel assemblies out of 177 in the core have now been broken free from the lower grid and loaded into canisters.

Four canisters were filled and one partially filled.

None of the filled canisters were transferred to the spent fuel pool.

I 2.

ENVIRONMENTAL MONITORING l

1 US Environmental Protection Agency (EPA) sample analysis results shew that TMI site liquid effluents are in accordance with regulatory limits, NRC requirements, and the City of Lancaster i

Agreement.

TMI intake water and water effluents from the station (Units 1 and

2) discharge are enalyzed by EPA.

Gauna spectrum analyses of the seven daily composited samples for June 27 - July 4, 1987 indicated L

no reactor related activity.

EPA's gar.na spectrum analysis of the NRC's TMI outdoor air sample for Ju!y 9 - 16, 1987 showed no reactor related radioactivity.

The water works for the City of Lancaster composited seven daily samples from June 28 - July 4, 1987.

EPA's gasna spectrum analysis of the composite sample showed no reactor related radioactivity.

3.

D, CONTAMINATION ACTIVITIES Sludge removal from the resctor building besement floor has been L

I completed. Robots were used to collect the sludge and the thin sludge / water mixture was pumped to collection tanks in the l

l 8707250160 870720 wm. >f-PDR ADOCK 05000320 1

R PDR

.a

- nunesAenn >

DATE D t

g

1 Dennis M. Crutchfield 2

July 20, 1987 frank Schroeder, Jr.

IGC/TMI-87-055 I

cuxiliary buildteg. About 1,000 gallons of dewatered sludge will be l

solidified prior to belug trasported mr disposal at a burial site.

An estimate of fcur 170 tubic feet liners will be required for the

{

solidification.

Robotic scabbling of flour areas in the seal injection valve room (SIVd) on the 281' elevation of the cu4iliary building has resumed.

About one third of the total floor sur face bas been scabbled.

Floor scubbling continues in the north and sauth valve alleys on the 261' elevation of the fuel handling building.

j tiands-on decontamination continues in the seal return cooler room en the 30S' tuevation of the euxiliury building.

l 4.

hRC EVALUATICM _IJ{ PROGRESS l

a.

f:RC Onsite Stoff Reviews Technical Specification Change Requests 52, 53 and 56.

l Recovery Opert.tions Plan Change Requests 30 ond 41.

Sulid Waste facility Technical Evaluation Report.

l tieavy Loed Safety Evaluation Report, Revision 3.

l Processed Water Disposition Proposal.

Lictv Evaluetion Report for Use of Plass Arc Cutting Torch.

Pressurizer Defueling Safety Evaluation Report.

Safety Evaluation Report for Def ueling of the Core Support Assdmbly.

Environmental Evaluatioa e

.he Post-Defueling Monitoreu Storage Preposal.

Cenister hunaling and -

aretion for Shipment Satety Evaluation Report, Re, ion 4 and Revis-lon 5.

Defucling Water Cleanup System Technical Evaluation Report Annuul Update.

Defueling Canister Technical Evuluation Repart Annual Update.

EPICOR 11 System description Annual Ups te.

Hec.vy Load Herdling - r/uvet.ent of hissile Snields.

1 Organization Plen Change Request 15.

l sequest for Exemption for 10 CFR 70.42 Requirem2nts.

1 i

b.

Utner hKC heviews nkC negion 1 is investigating anonymous alleiptions of a iGC l

licensed individual sleeping while performing licensed duties.

I 5.

EhVIROMENTAL IMPACT STATENENT lhe Progreamatic Environmental Imptet Statement Final Supplement No. E.

WUREG-0663, dealing with disposal of accident-generatea water was issued en June 30, 1987.

In Supplement 2, the scaff concluded that GPU Nuclear, l

Inc. 's proposal to dispose of the water by f orced evaporatica to the etssphere, f ollowed by onsite solidification of the racaining solids, and disposal in a licensed low-level waste disposal facility is an acceptoble plan and will recomend to the Cuamission that it be approved.

The steff evaluated this proposal, togethcr with eight alternatives, W"4

^">

mnc i onu m no m ~ncM ""

OFFICIAL RECORD COPY 2

Dennis M. Crutchfield 3

July 20, 1987 e

Frank Schroeder, Jr.

NRC/TH1-87-055 i

relative to the risk from radiation exposure to workers and to tne general public, the probability una consequences of accidents, the coastitment of resources (including costs) and regulatory constraints.

The staf f concluded that no alternative was clearly preferable to the GPU Nuclear, Inc. proposal.

An opportunity for a price hearing on the staff's proposal to lif t the prohibition on the disposal of the contaminated water is being of fered to GPU Nuclear Corporation and to other persons whose interest may be affected.

Requirements for filing a petition for leave to intervene in any proce-ding will be contained in a notice being prephred for publication in the Federal Register.

1 i

6.-

PubLIC MEETING The Advisory Panel for the Decontamination of Three Mile Island Unit 2 is l

scheduled to meet on August 12,1987 from 7:00 - 10:00 PM at the Holiday.

l Inn, 2? South Second Street. Harritrg PA.

1 Persuns oesiring to speak before the Advisory Panel are asked to contact l

Mr. Thomas Smithgoll at 2111 Marietta Avenue, Lancaster, PA 17603

{

(telephone 717-291-1041).

Persons desirinD to submit topics or questions i

for the Advisory Panel to consider are asked to contact the Chairman, I

t4ayor Arthur Morris,120 North Duke Street, Lancaster, PA 17602.

l ORGfNAL SIGNED BY, William D. Irovers i

f William D. Travers Director TMI-d Cleanup Pro.)ect Directorate:-

1

)

j I

i

( i.

i l

  • "'C9 l sunNaw y

,,,,,,,,,,,,,9 DATEk NRC FORM 318 (10 80) NHCM 0240 OFFICIAL RECORD COPY

_ ______w

Dennis M. Crutchfield 4

July 20, 1987 Frnnk Scheceder, Jr.

tiRC/TMI-87-055 INTERML DISTRIBUTI0ii CEhTRAL FILE hRC PDR LOCAL POR

'EDO OGC EPA DOE HI Regioncl Ada:inistr.ator RI Division Dirawr:;

Public Affairs, kl Sthu Lietsca, Ri idl tiQ r/f TMI SITE r/f Ti'.I-2 Project Scction file:

TMI-1 Resident Office (5)

TMI' Cleanup Project Directorate (14) 1 l

l l

l l

i.

1 l

.T,M,1,C,P D,,,,,

,TMI,C

,T,M,ICP j

,TM,Ih,B,, [,,

...T.r.'a.W..e......

SUMAw >.L. ho u.s.:.je.s..T.M.o.s.l.a k.......J.T.h.o.

W l

o^">

, cs/87

, 20/s7 7

7/

,a.d/87 7

.37./..87.,,,.

_ __ ____