UNITED STATES OF' AMERICA NUCLEAR REGULATORY COMMISSION Before Administrative Judges:

Peter B. Bloch, Chair-Dr. Walter H. Jordan Dr..Kenneth A. McCollom SERVED OCT -9 B87 In the Matter of

]

Docket Nos. 50-445-OL2

]

50-446-OL2 Texas Utilities Electric Co., at al. ]

].

ASLBP No. 79-430-06AOL

]

.(Comanche Peak Steam Electric Station,]

October 8, 1987 Units 1 and 2)

]

']

]

CONFERENCE PLAN (October 20 Prehearing Conference)

At the October 20, 1987, prehearing conference, the Board i

expects the parties to discuss, among other' things:

What documents do Applicants rely on to establish the adequacy of design and construction?

Whether or not the Board must make factual i

J determinations about the extent of the historical breakdown in QA/QC for design and construction.

Discuss j

the " holding" of cases cited as precedent in detail, including the significance of the factual setting.

Should there be a finding of historical inadequacy (breakdown) of QA/QC for design or construction, would Applicants have to show that their "get well" program achieved the same degree of safety as would have been achieved pursuant to adequate initial' implementation of Appendix'B7 l

Written answers to these questions should be in the hande the parties and the Board by no later than October 16.

In addit the parties shall also deliver to the parties and the Board by October 16, their proposed format for the prehearing conference FOR TH TOMIC SAFETY AND LICENSING BOARD:

j 8710260048 871008 PDR ADOCK 05000445 O

PDR Q

/

IPeter B. Bloch, Chair Administrative Judge Bethesda, Maryland