Steam Generators 11 & 12 Eddy Current Testing Final Rept Apr/June 1988
ML20235T925
Person / Time
Site: Calvert Cliffs 
Issue date: 06/30/1988
From: Creel G
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 8903080530
Download: ML20235T925 (153)


Text

{{#Wiki_filter:,__. I { I CALVERT CLIFFS UNIT 1 STEAM GENERATORS 11.and 12 EDDY CURRENT TESTING 'l FINAL REPORT April / June 1988 O ~ p<sa 241e 2

(M NY TABLE OF CONTENTS I. INTRODUCTION II. DISCUSSION Eddy Current Test Results for SG 11 APPENDIX I A. List with Plot of All Indications B. List with Plot of <20% Indications C. List with Plot of 20%-39% Indications D. List with Plot of >39% Indications E. List with Plot of Distorted Indications F. Lists with Plots of Tubes not Rolled G. Lists with Plots of Sludge Data H. List of Tubes Dented I. List with Plot of Tubes Plugged During the April / June 1988 Outage Eddy Current Test Results for SG 12 APPENDIX II () A. List with Plot of All Indications B. List with Plot of <20% Indications C. List with Plot of 20%-39% Indications D. List with Plot of >39% Indications E. List with Plot of Distorted Indications F. Lists with Plots of Tubes not Rolled ~' G. Lists with Plots of Sludge Data H. List of Tubes Dented I. List with Plot of Tubes Plugged During the April / June 1988 Outage Steam Generator Inspection Information APPENDIX III A. Steam Generator Support Location and Nomenclature B. Steam Generator Tube Sheet Pattern and Numbering System C. Eddy Current Inspection Acronyms

.i (D / v' I. INTRODUCTION Zetec, Inc. and NDE Technology were contracted in November 1987 to provide personnel to assist BG&E with the eddy current examination of the Calvert Cliffs Unit 1 Steam Generators in Lusby, Maryland. Zetec, Inc. provided twelve people for data acquisition and - ten people for the primary data evaluation. NDE Technology provided four people for the secondary data evaluation. This report summarizes the April / June 1988 eddy current. i inspection results of Calvert Cliffs Unit 1 Steam Generators. \\. O l l Page 1 i

i O II. DISCUSSION The MIZ-18 eddy current system was used to inspect the Calvert Cliffs Unit 1 Steam Generators 11 and 12.. The MIZ-18 uses addy currents as the probing media to measure ~ariations in effective ' conductivity and/or permeability of te tube being tested. .An alternating voltage is impressed across the test coil. The magnetic field developed by current ~ flow in the test coil causes eddy currents to flow in the tube wall. The corresponding magnetic field caused by eddy current flow in the-tube wall is out of phase with the field developed by the current in the test coil. Since these fields tend to cancel one 1 another, the coil, voltage is decreased in proportion to the_ l magnitude of addy current flow.in the test piece. The magnitude of addy currents in _ the test piece, thus the coil voltage, is dependent on the electrical properties of the tube being tested. The electrical properties which affect the flow of addy currents are permeability and conductivity. In non-magnetic materials, such as inconal and 300 series stainless steel, conductivity is usually the only significant variable. When the effective I conductivity decreases due to a discontinuity in the tube wall, O the coil voltage increases in direct relationship with the effective conductivity change. Thus, the amount of increase in coil voltage is related to the size of the discontinuity.in the tube wall. The coil voltage is sinuroidal, thus it can be . described with a single vector having magnitude and phase. The preselected Technical Specification eddy current (ET) testing plan for the April through June 3988 Calvert Cliffs Unit i refueling outage called for approximately 9% of the tubes in each steam generator (SG) to be inspected. The Technical Specification classification rules were applied to the test results of these tubes. The results were determined to be in Category C-3 and the requirement. to expand the inspection tt 100% was carried out for both SG's. All of the tubes in service in each SG were examined through their entire length. The 100% inspection required a total of 16,945 tubes to be examined. Of the 16,945 tubes

examined, 315 tubes had indications of 20%

through-wall degradation or greater. A total of 37 tubes had indications which exceeded the plugging limit. Twenty-one tubes were plugged in SG 11 and 16 tubes were plugged in SG 12 for this reason. O Page 2

l .As a preventative

measure, 31 additional tubes with indications in the sludge pile area were plugged.

Of these additional 31 tubes taken out of service, 21 were in SG 11 and g 10 were in SG 12. Previous metallurgical examination of Unit 1 tubing has shown degradation in these areas was caused by Intergranular Attack (IGA). Even though these 31 tubes had indications which were less than the. plugging limit, the tubes were plugged because of the potential for a local active IGA mechanism. The examination of SG's 11 and 12 was performed using the Zetec MIZ-18 digital data acquisition system.. The frequencies selected were 400, 200, 100, and 30 KHz - all of which were run in the differential and absolute modes. The examination was performed using a standard A.560-SF/RM bobbin coil probe. The MIZ-18 digital data acquisition system provides on-line data j digitization and storage onto magnetic tape cartridges.. The ? digital signal was also converted to analog where selected frequencies were recorded on strip chart media as an aid to the analyst. Each tube's eddy current data was analyzed by. two independent teams of qualified and certified personnel and by computer analysis..Zetec Analysis Software Edition 18.6, Rev. 5 with strip charts was used by each team of analysts. Additionally, all stored digital data was analytically processed by Zetec's Computer Data Screening (CDS) program using HP350 computers. All distorted and pluggable indications were O ratested. After all data review was completed, the primary and secondary lead analysts compared results with the CDS results and a final report was produced. Any final resolution that may have been required was performed by BGEE Laval III personnel. In addition to the standard addy current testing, some tubes were inspected using motorized rotating pancake coil (MRPC) probes. Short radius SG U-bend tubing was inspected utilizing U-band MRPC probes on both SG's. Of the 315 U-bends inspected using MRPC, no degradation was detected. Straight tube section MRPC probes were used in several tubes just below and above the secondary side of each SG hot leg tube sheet. These 58 tubes, located in the sludge pile area, were inspected to further quantify known bobbin coil indications. The straight tube section MRPC analysis confirmed the bobbin coil data. Profilometry ET was used to evaluate tube denting at the i i 9th and 10th solid support plates on both SG's. Trend analysis of the profilometry information showed no denting growth since the November, 1986 outage. O Page 3

Indications were found in a total of 290 tubes from the 8,463 tubes e.xamined in SG 11 and 286 tubes from the 8,482 tubes examined in ' SG 12. Thirty-seven tubes were found to ' have indications which exceeded the Technical Specification plugging limit of 40% loss of nominal wall thickness. The cold leg side of one tube found to have been misplugged in SG 12 during the 1986 Outage was correctly plugged.(see LER 317/88-03). An additional 31 tubes were plugged as a preventative measure. Of the total 69 tubes plugged during this Inservice Inspection, 42 tubes were plugged in SG 11 and 27 tubes were plugged in SG 12. Table II-1 is a summary of the Calvert Cliffs Unit One 1988 Eddy i Current examination results. Prior to the outage, an estimate of tube plugging for each SG was made based on ET data trend analysis. An eighteen month degradation rate of 7% nominal wall thickness was used. Using this degradation rate, it was estimated 76 tubes would exceed the plugging limit this inspection.

However, only 37 tubes l

actually exceeded the plugging limit. i various plots illustrating the locations and distribution of tube indications and a listing of tubes plugged this inspection for SG's 11 and 12 are provided in Appendix I and II respectively. The SG sketch in. Appendix III shows the'various tube support locations within the SG's and the nomenclature used throughout this report. All indications found were on tube outside surfaces. The l tubing ET indications can be placed into one of three major location categories: just below and above the top of the tube sheet at supports, or in free span areas between and not associated with supports. These inspection results are similar to that reported for Calvert Cliffs Unit 2. There are no apparent differences between Unit 1 and Unit 2 that indicate a unique problem in any particular SG. This is to be expected since operating and chemistry conditions have remained similar between the' two plants. Indications found just below and above the top of the tube sheet are in regions of higher sludge levels. Most of these indications are on the inlet tube sheet side and produce relatively low magnitude signals. In late 1986, tube specimens. containing these type of indications were removed from SG 11 and have undergone metallurgical and chemical evaluations. Results show that these indications are caused by IGA. O 1 i Page 4

4..t 4.:

TABLE II - 1 Unit One 1988 Eddy Current Inspection Results SG ill SG #12 Number of Tubes Inspected 8,463 8,482 Percent of Tubes Inspected 1004 100% Number of Distorted Indications 15 13 Number of Tubes with Distorted Indications 13 13 Percent of Tubes with Distorted Indications 0.15% 0.15% Number cf-Indications <20% (Imperfections) 141 160 Number of Tubes with <20% Indications 135 152 Percent of Tubes with <20% Indications 1.60% 1.80% f i. \\ Number of Indications 20-39% (Degraded) 166 147 Number of Tubes with 20-39% Indications 149 136 Percent of Tubes with 20-39% Indications 1.75%. 1.60% Number of Indications >39% (Defective) 21 17* Number of Tubes with >39% Indications 21 17* Percent of. Tubes with >39%-Indications 0.25% 0.20% Number of Tubes Plugged this Outage 42 27* Total Tubes Plugged each Steam Generator 98-65* Note: Tubes, which contained more than one indication in more than one category (<20%, 20-39%, and 40% and greater), are listed in all appropriate categories.

  • These numbers include R94 L66 found to be defective during the 1986 outage (see LER 317/88-03).

O Page 5

1 ET indications seen at support locations appear to be caused-by tube wear or steam blanketing corrosion. Wear. marks at :a support contact region were confirmed'on one tube removed from SG 1 11 in 1983. Note that most indications at supports occur at the vertical middle '(VM),. diagonal (DH & DC), and vertical hot and cold (VH ' & VC) leg. side supports. Indications seen at the VM support location within rows 8.through 11 may-be the result of -j r steam blanketing corrosion; the specific mechanism has yet to be confirmed due to the inability to remove specimens from this l region. 1 ET indications seen in free span areas are typically. low magnitude. signals. Three tube specimans containing ' free : span ] indications were removed from SG 11, one in November 1983 and two. 1 3 in November 1986. Investigations of the free' span indications i showed these indications are manufacturing imperfections. There-is no correlation of free. span indications with respect. to

location, elevation, inlet
side or outlet side; tube manufacturing imperfections would be expected to produce random occurrences like this.

Corrective measures have been initiated to minimize further P degradation to the SG's. During the 1986' outage we completed the removal of 'all major copper components from the feedwater and condensate systems. We are completing installation of a nitrogen-blanketing system on all condensate storage tanks to reduce auxiliary feedwater and condensate makeup oxygen. We are using morpholine which will minimize the ingress of solids from the secondary system into the SG's and-may promote sludge pile reduction. Our current chemistry procedures require action to be taken below the Utility /EPRI Steam Generator Reliability Project (SGRP) PWR Secondary Water Chemistry Guideline Action Levels. This enables us to initiate corrective measures before conditions become degraded'in the SG's. During outages steam generators are kept in wet lay-up with a nitrogen blanket as much as possible. l 8 s Page 6 i

'1 l ) GI $$) I APPENDIX I EDDY CURRENT TEST RESULTS l STEAM GENERATOR 11 A. List with Plot of All Indications B. List with Plot of <20% Indications C. List with Plot of 20%-39% Indications D. List with Plot of >39% Indications E. List with Plot of Distorted Indications F. Lists with Plots of Tubes not Rolled TO G. Lists with Plots of Sludge Data H. List of Tubes Dented I. List with Plot of Tubes Plugged During the April / June 1988 Outage l. ( r

O STEAM GENERATOR 11 A. List with Plot of All Indications O i / O I

) ,ji ] [i j.I ,1 I;; , l :i. f!l g f , g ,,,,,,,,,,,,,,,,g_ _ = _. _ _ _ _ _.. 4,,3 1 s. xtU m Nl g i. _. L. L on 9 _.j 1 5 o. 8 2 n m: r _= E 7 u r u t r 4 G s _ 7_ A S e s T E s_ a . t. 4. t_ B: o s U a e I ) TW s s. O u ( r 4 LS o AY n 8 TA rm 4 8 OT a _..i TS 3 r / 4 6 =

q, _.

S 6._ j'; N q_;

h. =_4_ g_ q.

L_ 6-O ,gg .._ g ,a _ __ b. j,;_,.. I _u_>. T a: = l_ A s VE = _=__'.J L E 8 8 E ._t _ _. _..q __ y - i_ 2 1 ( 1 p s n _. LL t L O . 8 } L I T _.4 .a A A c 3 R: eI

4. iJ_.

me ._= q._ _ O at m^-.,,_ = ._ _y s S T cI .a 4_

  • e i'v A

oE u __1 j,_. _. L_ = N R aL s O E

= e

E T: G oD NA aO m

AT - = LU PO 4 t ,,gn i, E gs gEgg3 _ 9. v ,]._ 9 1 5 2 E 8 7 1 G A D T E ) 2 N U 7 7 G ( I O e S S S 3 A E B; 0 S j 8 8 U) 2 E Tf B / t ( Y 4 LS 0 AY 0 L A T A T OT O T TS 3 T

=

E p E

_ p H

4 L } _._ij. _. 3,_._ 4i. l. 01 S - u. ~ E B L , s _. 4 J . __g_.. . p '~~Lj U A_{. 4.y_J___ 'p I T 1_ i1 _J.' /. = , s ,. t _ G _ 4_ly _ 3+ d. l-i_ E t_4_ ;._L_ - I L y4._._- ) >i 3 piwj41. _. 1 T ( _,L L.

4. L _

N O L_. _ _ - - 1 O 1 I H T Ig q1 L_ ,L

_!._ L_. 4 A

_6 s C E R 1 I _ ~ 3. 7 O ~ . 7;_ 44_ l . 7 _A _. _. e m_, H O 7 P S~ f T T I E T ~ A D 0~ 0 E p, e R 2 L / E E < P 9 p _ r N I A . q - T. 1= L V E O G 0 IM 8 e-___ ___,e. g L }. L ji, 0 B = - A a s8 c [ ._I l.{. S _. H. N .f4_ t 1

  • 8 I

O .___J T m [ r 4 ,} a C A 4 D . 4 u7 9_ 8 I 9 1_ N g = I e FO u c 1 T T I O NU LP SFF 1 I L 1 C88 )o T/ f G R4 ) S E0 tA1 0 V I( L c A E9 C p3 s> = _ h E

TG oD

~ NA c0 ~ AT - = LU ~ PO L4 r [Il>i l- ,,3g _ g f je - yE lhnt C L[ER[ CLIFFS UNIT I Stes: Gene ra.::: 11 n Outage: 04/88 OUERY: OD,ALL t TW,ALL VOLTS,ALL ELFV :ALL TUPFSt,ALL-SL y / ROW-LINF OUTAGF FLFVATT0N INDICATT0N t TW vo!5 33.90" OD 13 0.9 3-31 04/88 C2 O.90" OS 18 0.1 + 3-123 04/88 CTS-SF + 0.40" OD 26 C.g 5-43 04/88 HTS-SF + 1.40" OD 30 0." 5-111 04/88 HTS-SF + 6-54 04/88 C3 + 9.70" OD 17 0. 6-56 04/88 HTS-SF + 0.60" OD 12 0.6 6-58 04/88. HTS-SF + 1.50" OD 15 0.1 6-60 04/88 HTS-SF + 0.70" OD 22 0.{ 8-108 04/88 CTS-SF + 1.00" OD 39 0.c 8-150 04/88 VM OD 11

1.,

8-164 04/88 C4 + 18.40" OD 22 0.( 9-11 04/88 VM OD 17

1. f 9-23 04/88 VM OD 10 2.<

9-25 04/88 VM OD 17 0.( 9-57-04/88 HTS-SF + 0.80" OD 25 0.{ 9-113 04/88 HTS-ST + 1.00" OD 33 0.' 9-121 04/88 VM OD 19 0.d 10-48 04/88 HS + 21.60" OD 11 0.1 11-27 04/88 VM OD 34 0.1 1.30" OD 27 0.1 11-33 04/88 CTS-SF + 04/86 VM OD 11 0.f 1.10" OD - 28 0.< 11-113 04/88 HTS-ST + 11-137 04/88 DH OD 23

0. !

11-147 04/88 DH + 2.10" 00 57 0.! 04/88 VM OD 25 1. 3.80" OD 19 0. 12-160 04/88-H2- + 1.10" OD 24 0. 13-113 04/88 HTS-SF + 1.20" OD ll 0. 15-III 04/88 HTS-SF + 16-58 04/88 HTS-SF + 1.00" OD 17 0. + 1.10" OD 35 O. 16-110 04/88 HTS-SF + 1.40" OD 21 0. 16-112 04/88 HTS-SF 0.80" OD 15 O. J,,i 17-115 04/88. CTS-SF + i' ,) 18-110 04/88 HTS-SF 4 0.90" OD 15 0. 18- '120 04/88 CTS-SF + 1.00" OD 23 0. + 1.30" OD 24 0.' l-19-113 04/88 HTS-SF 17.60" OD 16 0.. l 19-117 04/88 H2 + + 0.90" OD 26 0. [ 20- 110 04/88 HTS-SF 22-46 04/88 HTS-SF + 29.20" OD 15 O. 22-116 04/88 HI + 33.00" OD 37 0. + 5.10" OD 26 0. 23-15 04/88 HTS-SP + 0.80" OD 17 0. 23-57 04/88 HTS-SP + 1.00" OD 10 1. 24-38 04/88 HTS-SF 24-54 04/88 HTS-SF + 1.10" OD 10 0. 24-56 04/88 HTS-SF + 0.70" OD 21 0. + 1.00" OD 17 0. 25-37 04/88 HTS-SF 0.90" OD 15 le 25-39 04/88 HTS-SF + 25-53 04/88 HTS-SF + 0.90" OD 19 0. 25-59 04/88 HTS-SF + 0.80" OD 10 Ic 26-38 04/88 HTS-SF + 1.00" OD 11 00 26-40 04/88 HTS-SF + 0.90" OD 13 Ic + 8.70" OD 22 00 t 26-122 04/88 CTS-PF l 27-7 04/88 HTS-ST + 3.38" OD 19 00 27-33 04/88 C2 + 33.80" OD 59 00 27-55 04/88 HTS-SF + 1.30" OD 11 00 27-59 04/88 HTS-SF + 0.90" OD 12 Oc 29-53 04/88 H3 + 8.16" OD 10 0.0 + 0.60" OD 15 00 F-29-109 04/88 HTS-SF 29-111 04/88 HTS-SF + 0.60" OD 35 00 f 30- 110 04/88 HTS-SF + 0.70" OD 33 Oc 30- 112 04/88 HTS-SF + 1.20" OD 28 00 30- 114 04/88 HTS-SF + 1.00" OD 13 00 + 0.60" OD 12 10 30- 116 04/88 HTS-SF + 0.90" OD 12 Oc 30- 128 04/88 HTS-SF + 32.90" OD 19 00 30- 130 04/88 H4 30- 144 04/88 C3 + 26.90" OD 26 00 . f} m ,-y -~ - Plant: CALVERT CLIFFS UNIT 1 Steam Generator: 11 Outage: - -04/88 7 OUERY: OD,ALL t TW,ALL VOLTS,ALL ELEY (ALL'TUEES),ALL-RL ~ g1 t ROW-LINE OUTAGE FLFVATION ' INDICATION t TW VOLT!

A ~

0.60" OD 27 0.51 31-119 04/88 H.TS-SF + 6.58" OD 10 1. 46 32-

28. 04/88 C7S'SF

+ 11.50" OD 17 0.5 32-36 04/88 H2 - + + 0.80" 'OD 10

0. 9(

32-126 04/88 HTS-SF 33-109 04/88 HTS-ST + 'O.80"' OD 11 0.64 33 -111 04/88 HTS-SF + 1.00" . OD 15 0.8: 34-70. 04/88 _ CTS-SF + 0.90" OD 28 0.8G 34-144 04/88 C4 + 27.40" ~OD ~ 31 0. 71 35 127 04/88 HTS-SP + 1.00" .OD 16 0.5: 1.90" OD 31

0. 5' 38-.

48 04/88' HTS-SF + 39 - 51 04/88-HTS-ST + 2.20" .OD 21 0.4' '39-117 04/88 HTS-SF + 1.30" 'OD 18

0. 6!

40 - 48 04/88 HTS-SF + 1.20" OD 19-

0. 4(

42-52 04/88 -HTS-SF + 2.40" OD 22

0. 7; 42-54 '04/88 HTS-ST

+ 2.70" OD 25

0. 7(

2.80" OD 17

0. 8; 42--114.04/88 HTS-SF

+ 42 118- 04/88 HTS-SF + 1.60" OD 24.

0. 7(

+ 1.50" OD 10

0. 7!

42-120 04/88 HTS-SF + 2.34" OD 11 1.1 ( 43- .53 04/88 HTS-SF 1.60" OD 13 0. 44 ~43-111 04/88 . HTS-SF + 1.70" OD 12-

0. 5 <

43-119 04/88 HTS-SF + 6.10" OD 17-

0. 8l c44-110 04/88 HS

+ 2.70" OD 12

1. 2!

44-114 04/88 HTS-SP + 2.60" OD 15

1. 2i

.04/88 HTS-SF +- 45-51 04/88 HTS-SF + 0.76" 00 43

0. 7) 1.03" OD 52 1. 32 45--

55 04/88 HTS-SF + 46-' 52 04/88 HTS-SP + 2.20" OD 35

0. 7; 46-.116 04/88 HTS-SF

+ 2.80" OD

15
0. 7 t 46 -158 04/88 C4

+ 27.20" OD l' ' O. 41 47-103 04/88 HTS-SF + 0.90" OD 12

0. 5' 48-.58 04/88 HTS-SF

+ 2.60" OD. 33

0. 5 l w-49-103 04/88 HTS-SP

+ 0.90" OD 17

0. 5!

1.0C" OD 17 ' 1. 0 < 't i 49-: 105- 04/88 HTS-SF + 3j-50-16 04/88 H4 + 8.67" OD 47

0. 6 <

0.91" - OD 31

1. 0!

50-54 04/88 HTS-SF + + 0.64" OD 23

3. 3' 50-56 04/88 HTS-SF 2.66" OD

- 12 ~ 0.7 50-58 04/88 HTS-SF + 51-63 04/88 HTS-SF 4 2.00" OD 37

0. 4!

51-111 04/88 HTS-ST + 0.80" OD-39 2. 11 52-.16 04/88 C4 + 2.76" OD 28

0. 7 >

1.09" OD 16 0.8 52-58 04/88 HTS-SP + 04/88 HTS-SF + 1.79" OD 12 0.8 04/88 HTS-SF + 2.55" OD 22 1.2 52-110 04/88 HTS-SP + 0.70" OD 23

1. 7i 52-114 04/88.

HTS-SP + 0.60" .OD 39 1.1 ' 53-55 04/88 -HTS-SF + 0.61" OD 36 1.2 53-65 04/88 HTS-SF- + 1.90" OD 10

0. 9:

1.20" OD 29 0.3 53-71 04/88 -HTS-SF + 0.70" OD 38 0.6 '53-113 04/88 HTS-SF + 54-.56 04/88 HTS-ST + 0.64" OD 37 1.E 58 04/88 HTS-SF + 0.64" OD 64 0.5 54-70 04/88 HTS-SF + 1.30" OD 11 0.9 54-110 04/88 HTS-SP + 0.80" OD 34 2.T 55-57 04/88 HTS-SF + 0.82" OD 48 2.G 55-59 04/88 HTS-SF + 0.80" OD 28 0.5 55-69 04/88 HTS-SF + 1.70" OD 11 1.@ .55-71 04/88 HTS-SF + 1.40" OD 27 0.0 111 04/88 HTS-SF + 2.40" OD 17 0.@ 56-58 04/88 HTS-SF + 0.79" OD 35 4.@ 56-60 04/88 HTS-SF + 2.60" OD. 22 0.6 56-68-04/88 HTS-SP + 1.70" OD 16 1.1 56-106 04/88 HTS-SF + 1.70" OD 22 0.7 + 1.90" OD 17 1.@ l' 56-112 04/88 HTS-SF 57-59 04/88 HTS-SF + 0.70" OD 10 0.@ 57-61 04/88 HTS-SF + 1.90" OD 15 0.4 I. d

Plant: -CALVERT< CLIFFS UNIT 11

' Steam Generator: 11' L Outage tc 04/80' OUERY:'OD,ALLl%'TW,ALL. VOLTS,ALL ELEV iALL~.TUBESi,ALL-RL ,. ~. / 1( ROW-LINE OUTAGE ELEVATION INDICATION t-TW VOLT 'Y '57-67 '04/88 HTS-SF 4 1.7D" OD 12 0.6 2.10" OD 15

0. 7' 105 04/88 HTS-SP

+ 57-109 04/88 HTS-SF + 2.70" OD 17 0.7 04/88 HTS-SP + 2.30" OD 10 1.6 58-58 04/88 HTS-SF + 0.70" OD 13~ 0.4 58-64 04/88 HTS-ST +' 2.00" OD. 11

0. 6:

58-70' 04/88 HTS-SP .+' l'.00" OD- -13

0. 3-59-57 04/88 HTS-SF

+ 1.20" OD 38 .0. 8 59 04/88 HTS-SF +. 1.80" OD-16' 1.3 04/88 HTS-SF -+ 2.70" OD 10 0.8 59-61 04/88 -HTS-SF + 2.10" .OD 13 'O.4' 59-97 04/88 . HTS-SP + 1.20" OD 22-0.~ 6 ~60-58 04/88 HTS-SF + 1.20" - OD - 12 1.4 60-68.04/88 HTS-SF' . +

1. 6 0 "-

OE 34 0.5 61- :65 04/88 ' HTS-SF + 1.00" OD .10 ' O.~6' 61-67 04/88 . HTS-SF + 1.60" OD 12 0.6 61-71 04/88 HTS-SF + 1.70" OD. 13 1.' O 61-93 04/88 H3 + 30.60" OD .24 0.6 61-105 04/88, HTS-SF + 1.80" OD 31

0. 4 -

62-58 04/88 C2 + 18.73" OD. 16 0.8 62-66 04/88 HTS-SF + 2.30" OD 11 l'.2 62.102 04/88 HTS-SF. + 2.20" OD 13 0. 7. 63-69 04/88 HTS-SF + 2.20" OD 11

0. 5i 63-105 04/88 HTS-SF

+ 2.00" OD 26-

0. 9; 18.60" OD

.12 0.5 64-56 04/88 H4- + .2.20" OD 25

0. 4' 64--

68 04/88 HTS-ST + 1.80" 'OD 26

0. 4^

64-102 04/88 HTS-SF + ' 1. 2 4 "- OD 32

0. 7.

65-55 04/88 H3 + 1.90" OD 13 - 0. 9; '65-1 69 04/88 HTS-SF + 04/88 HTS-ST + 1.20" OD 15 0. 64 65-75 04/88 HTS-SF + 3.00" OD 24.

0. 5' (N.

65-89 04/88 HTS-SF + 0.80" OD 16 0.6 65-93 04/88 HTS-SF 2.80" OD 16

1. 2l

+ 2.40" OD 25

0. 6' J

'65-~101 04/88 HTS-SF + 8-(/ 65-103 04/88 HTS-SF + 1.90" OD 32

0. 6; 65-149 04/88 H4.

4 34.20" OD 24

0. 5!

34.20" OD 21

0. 7; 04/88.

H2 + 1.80" OD -18 '1. 7 ' 66- .68 04/88 HTS-SF + ' 6 6 -- 70 04/88 HTS-SF 4 1.90" OD 12 0. 74 66'- 72 04/88 HTS-SP + 1.80" OD 15

0. 9!

66-74 04/88 HTS-SF + 1.80" OD 16

1. 0!

66. 80 04/88 H3 + 5.10" OD 17 1. 22 66-102 04/88 HTS-SF + 1.70" OD -24

0. 7!

66-150 04/88 .DH + 15.50" OD 37

0. 7(

67- :81 04/88 C5 + 10.20" 'OD 38

0. 5 {

68-70 -04/88 HTS-SF + 2.70" OD l ').

0. 6(

68-72 04/88 HTS-SF + 1.90" OD 10 0.9( '68-- 94 04/88 HTS-ST + 3.00" OD 22 0.5 69-69.04/88 HTS-SF + 1.60" OD 18

0. 8 <

69-71 04/88 HTS-SF + 2.40" OD 19

0. 6:

69-85 04/88 HTS-SF + 1.70" OD 38 . 0. 5( 69-93 04/88 HTS-SF + 0.50" OD 13

1. 2l

.04/88 HTS-SF + 1.10" OD 61

0. 6{ 68 04/88 HTS-SF

+ 1.20" OD 12

0. 6:

70-70 04/88 HTS-SF + 1.50" OD 25 0.7 70-72 04/88 HTS-SF + 1.90" OD 22

0. 6; 70-76 04/88 HTS-SF

+ 1.20" OD 22

0. 8<

23 1.1 < 70-78 04/88. HTS-SP +- 2.10" OD 70-82 04/88 HTS-SF + 2.90" OD 23

0. 4(

70-88 04/88 HTS-SF + 3.00" OD 34

0. 6(

70-90 04/88 HTS-SF + 0.80" OD 35

0. 5 C 70-92 04/88 HTS-SF

+ 0.80" OD 48

0. 9{

04/88 HTS-SF + 1.00" OD 23

0. 8<

70-94 04/88 HTS-SF + 2.80" OD 26

1. 2 t

.I 71-43 04/88 H3 + 18.38" OD 17 0. 61 1 1: Plant: CALVERT CLIFFS UNIT 1 Steam Ger.eratcr: 11-Outoge: 04/88 i OUERY: OD,ALL 1, TW,ALL VOLTS,ALL ELEV f ALL TUIiES ), ALL-RL i mj ROW-LINE OUTAGE ELFVATION INDICATION t TW VOLTS 0.70" OD 44 1.58 71-83 04/88 HTS-SP + 0.60" CD 31 0.73 71-89 04/88 HTS-SF + 04/88 HTS-SF + 0.90" OD 35 0.60 71-91 04/88 HTS-SF + 0.80" OD 19 1.08 71-93 04/88 HTS-SF + 1.10" OD 31 0.91 04/88 HTS-ST + 1.80" OD 28 0.47 04/88 HTS-SF + 0.60" OD 23 2.72~ 71-95 04/88 HTS-SF + 2.50" OD 12 2.19 72-30 04/88 C1 + 26.63" OD 12 0.96 72-72 04/88 HTS-PF + 1.40" OD 19 0.95 72-88 04/88 HTS-SF + 0.60" OD 23 1.25 72-90 04/88 HTS-SF + 0.60" OD 38 1.04 04/G8 HTS-ST + 1.20" OD 34 1.15 72-152 04/88 H3 + 32.20" OD 15 0.71 73-29 04/88 DC OD 13 1.33 73-89 04/88 HTS-SF + 0.50" OD 47 1.06 73-93 04/88 HTS-SF + 1.20" OD 13 1.37 74-50 04/88 C1 + 13.43" OD 12 0.73 74-84 04/88 HTS-SF + 9.70" OD 31 0.63 74-86 04/88 HTS-SF 4 0.60" OD 49 1.13 74-88 04/88 HTS-ST + 1.00" OD 23 3.75 0.60" OD 62 1.17 74-92 04/88 HTS-SF + 2.70" OD 15 2.26' 04/88 HTS-SF + 15.79" OD 18 1.01 75-15 04/88 CI + 1.10" OD 32 0.50 75-83 04/88 HTS-SF + 75-85 04/88 HTS-SF + 0.70"' OD 46 2.20 2.10" OD 38 1.04 75-93 04/88 HTS-SF + 2.80" OD 41 1.49 04/88 HTS-SF + 76-90 04/88 HTS-SF + 2.10" OD 27 1.77 + 1.50" OD 13 1.27 76-92 04/88 HTS-SF 76-98 04/88 H5 + 5.00" OD 22 0.68 /. 76-114 04/88 C1 + 10.60" OD 10 0.91 ') 76-132 04/88 H5 27.90" OD 17 0.74 + 'V 04/88 H4 + 20.40" OD 19 0.93 04/88 H4 + 13.40" OD 39 0.59 04/88 H4 + 4.00" OD 37 0.58 77-23 04/88 VM OD 31 0.66 77-59 04/88 H6 + 13.95" OD 38 0.63 23.29" OD 34 0.69 77-67 04/88 VH + 77-85 04/88 HTS-SP + 1.60" OD 23 1.24 77-87 04/88 HTS-SF + 0.90" OD 36 0.69 77-89 04/88 HTS-SF + 1.00" OD 25 0.75 04/88 HTS-ST + 1.80" OD 43 1.58 04/88 HTS-SF + 2.50" OD 27 0.75 77-111 04/88 H2 + 29.50" OD 38 0.51 78-22 04/88 C7 + 8.55" OD 35 0.79 78-84 04/88 HTS-SF + 1.40" OD 12 1.57 78-88 04/88 HTS-SF + 1.40" OD 42 1.20 78-90 04/88 HTS-SF + 1.20" OD 23 1.17 79-21 04/88 C1 + 17.40" OD 24 0.57 79-89 04/88 HTS-SF + 1.70" OD 31 1.21 80-18 04/88 C1 + 19.75" OD 20 0.56 80-80 04/88 HI + 29.40" OD 33 0.51 04/88 H2 + 18.40" OD 22 0.68 80-90 04/88 HTS-SF + 0.60" OD 30 0.61 80- 140 04/88 H4 + 24.80" OD 22 0.55i 81-85 04/88 HS + 17.10" OD 24 0.79' 81-87 04/88 H4 + 3.20" OD 13 0.62 82-88 04/88 C3 + 29.50" OD 35 0.62 83-149 04/88 H2 + 7.90" OD 25 0.68 84-116 04/88 CTS-SF + 20.70" OD 22 0.50' 86-38 04/88 HTS-SF + 1.00" OD 19 0.57 86-46 04/88 CO + 10.15" OD 39 1.07 + 16.30" OD 16 0.59 86-100 04/88 HTS-SP f 21.90" OD 28 0.52 86-110 04/88 C1 + p)

Gi

x _ , ~.. Plant::CALVERT CLIFFS UNITL1 Steam Generator: 11 -Outage: 04/88 s o "OUERY: OD,ALL 9,.TW,ALL VOLTS,ALL ELEV-(ALL TUBES),ALL-RL- ,. m 1 )- \\ f ' ROW-LINE- ' OUTAGE ELFVATION INDICATION 9. TW~ VOLT! 04/88 .C3

+ -l 1'. 4 0 "

' OD-22

0. 5' 15.80" OD 20
0. 6 :

89-143- 04/88 HO' ' + 30.60" OD 22 0.56 90-. 22 04/88. C2 91-141 04/88 H3 + 36.80" OD 17' 0. 52 92 -.30. 04/88 HS + 7.30" OD 25

0. 8 <

92-' 72 04/88 C2 + 15.70" OD 19- .1. 0 ' L 108 04/88-H5 + 8.20" OD-27

0. 6f 93-25 04/88 VH

+ 26.62" OD 7

0. 9 <

04/88 VM + 14.54" -OD 32' ' O. 5i L. 94-' 81 04/88- .H4 + 15.10" OD. 12. 0 '91 L 93-54 04/88 H7 +-14.41" OD 15 'O. 71 95-53 04/88 C4 + 28.00" 'OD 24

0. 6a 95-125 04/88.

H5 -OD 35

0. 7l 04/88 H3

+ 29.50" OD 12' O.9! .96-50' 04/88 C7 + 12.40" OD 26

0. 6 <

98-46 04/88 C1 + 18.60" OD. 16 0. 91 ,99-73' 04/88 VH + 17.30" OD 10

0. 8'

,100-68 04/88 C1 + '21.20" OD 29. -- 0. 6 2 14.00" .OD 13

0. 7i

.100-70.04/88 C4 + 7.00" OD '39 0.5; 101-107. 04/88 H2 + 103-83 04/88 H5 +- 4.60" OD 26

0. 5[

.04/88 HS + B.30" OD 20

0. 7:

16.90" OD 13 . 0. 7( 04/88 H5 103-125- 04/88 VH' OD 54

0. 5;

.104-: 132 04/88 H3 + 6.40" .OD 27

1. 0:

20.90" OD 16-0. 51 104-140 04/88 C3 . + 37.80" OD 28-0. 51 105-93 04/88 C-*-SF + OD' 35

0. 5' 04/88 C.

. 10.80" OD '26

0. 8' 04/88 C2

+ 35.70" OD 35

0. 6!

04/88 C2 + 37.'70". DD 24

0. 5; 04/88 C3

+ 3.20"' OD 19

0. 5;

' [] 04/88 C4 + 20.10" OD 16 0.7 .4 j-105-101 04/88 C4- + 10.60". OD 10

0. 8; V

106-' 76 04/88 DH + 2.00" OD 23

1. 2!

-106-88 04/88 VM + + 24.40" OD 37

0. 5' 108-92 04/88 H7 04/88

-H8 + 5.00" OD 30 0. 81 108-100 04/88 H2 + 27.80" OD 23 1.1 l 114-126 04/88 DH + 12.90" OD 23

0. 6; 115-109 04/88 H8

+ 19.70" OD 19

0. 6!

'115-121 04/88 CTS-SF + 35.70" OD 0. 7; + 10.80" OD 38

0. 5' 116-118 04/88 C9 117-87 04/88 DC

+ 1 5.'1 0 " OD 34

0. 5:

122-54 04/88 H9 + 18.50" OD 26

0. 6!

124-48 04/88 H9 + 5.50".- OD 27

0. 5:

124-114 04/88 C3 + 34.40" OD 38. ' O. 5: 04/88' C3 + 38.20" OD 27 0.8 125-59 04/88 C3 + 16.60"~ OD 22 0.7 26 0. 74 04/88 C4 + 3.40" OD 127-99 04/88 C1 + 33.90" OD 33

0. 7.

128-80 04/88 H4 + 21.60" OD 11 -0.1 04/88 H4 + 24.40" OD 23 0.7 128-118 04/88 C6 + 8.20" OD 33 -0.6' 129-65 04/88 H6 OD 22 0.6 129-81 04/88 DH + 10.80" OD 13

0. 4' 129-95 04/88 C1

+ 10.50" OD 21 0. G: 131-113 04/88 VM + 4.00" OD 30 0.T 133-67. 04/88 CTS-SF + 0.80" OD 27 0. @- 133-71 04/88 H3 + 7.70" OD 35 0.9 133-81 04/88 C6 + 21.80" OD 13 0.G 04/88 C6 + 11.20" OD 34 0.9 134-108 04/88 HTS-SF + 12.60" OD 48-0.@ 10.60" OD 56 0.Q 136-68 04/88 CTS-SP + 138-68 04/88 CTS-SP + 10.40" OD 36 0.7 138-76 04/88 CTS-SF + 11.00" OD 48 0.9 'f C-t s p ..un.cuo vuom.m. 4,00. a.v emox co.co, o, u. wm - aw ~ mmm m u mu s s, o. o Plant: CALVERT CLIFFS UNIT 1 Stear. Generator: 11 f Outage: 04/88 OUERY: OD,ALL t TW,ALL VOLTS,ALL ELEV (ALL TUEES1,ALL-RL _s ( \\ ELEVATION INDICATION

  • TW VOLTR

() ROW-LINE OUTAGF 139-83 04/88 CTS-SF + 0.50" OD 39 1.11 19.60" OD 28 0.60 140-80 04/88 CTS-ST + 140-88 04/88 C2 CD 3B 0.06 TOTAL TUBES: 290 I i / f f ot] l l l i l e i STEAM GENERATOR 11 B. List with Plot of <20% Indications 1 0 O i1 l i1I'J

1 9 l iv e

. ens e d 0. -,. mn.,,m a =. N5 i t o 0 0 1 1 s s 1 s s s s s 1 Y a3.- co 9 1 a 5 5 8 3 1 E D N 7 G i I o S t S SA E e U) E B: S E Tf B t ( T G LS m AY L A TA A T T OT U TS a T U = O 6 8 o 8 / a 4 '= '= S N ~ m O I T m AC 1 a 1 I D a N n R a I O t _ s T E a e ? A o o s, R In 0 0 E 1 0 t 2 E , a N 1 u G o a e L u l s s L a m ,t A = i u e F O v ,a ? T ,+ = = O a = s L P , a 1 e 1 G 1 S T I a N U 4 a s S F ). e F T. l I a N m L O C8 I 8 T iT T/ A a C R4 I t E0 o V ePe n a L mI A E C aL 3 <P I y E: - T s L s

TG oU o

NA nM m AT - = A LU PO oa ,,.5 l. g.a I_& ,ig I g g. l mm t# p"3 g g 1CALVERT CLIFFS 'NITal ' Steam Generatort: 11~ U ~ i. . Outage 04/88 ~ . QUERY: OD,<20 9, STW,ALL' VOLTS,'ALL ELEV'(ALL TUEES),ALL-RL ,A [ I ROW-LINE OUTAGE FLFVATTON TNDICA'TTON t' TW ' VOLTS: L/ ~ '3- >31 04/88' -C2 + 33.90" OD 13 0.51.d -0.95 !j .3 123 04/88 CTS-SF' + 0.90" OD 18 0.56 '6- -56 04/88. HTS-SF. + 9.70" OD 17 ~ 6-54 04/88 C3. 0.60" OD-12 0.84 ! + 58 04/88 HTS-SF + 1.50" OD 15 0.59,I 8-150: 04/88-VM. O D -' 11 1.'1 2 : .9-~ 11-04/88 .VM OD-17~ 1.86 l 9-23- 04/88' VM OD 10

2. 3 6' !

9-1 25: 04/88 VM OD 17' O.90 ' 9-~121 04/88. -VM OD 191 -0.961l 10 ".48: 04/88' H5- + 21.60"- OD 11 0.51 - 11 - 33 04/88 .VM ' OD O.89 '12-160 04/88: H2 + 3.80" OD 19-0.67 15-.111 04/88 HTS-SP + 1.20" OD 11 .0. 51 ! 16 - 58 04/88 HTS-SF + ' 1.00" OD 17-0.41-17-115 04/88 CTS-SF +1 0.80" OD. 15 0.45 0.90". OD~ 15 0. 7 0.- 18-110.04/88 HTS-SF + l19-117: 04/88. H2 +. 17.60" OD 16 0.50' L22-' 46-04/88 HTS-SF + 29.20" OD 15 0. 51.' ' 23-' .57 04/88 HTS-SP + 0.80" OD 17-0.45' 24 - 38 04/88 HTS-SF + 1.00" OD 10 1.04 24 : 54 04/88' HTS-SF + 1.10"- OD 10 0.54 + 1.00": OD- '17 0.52: 25-- 37 04/88 HTS-SF 25-39 '04/88 HTS-SF + 0.90" OD 15 1.24- + 0.90" .OD 19 0.52 25-53 04/88 ' HTS-SF + 0.80" OD 10.' 1.15'- 25-59 04/88-HTS-SF 1.00" OD 11 0.43' 26. '38-04/88 HTS-SF + 0.90" OD 13 l'.08 '26- -40 04/88 HTS-SF + 3.38" OD 19. 0.54 ' 7 04/88- . HTS-SP 27-55. 04/88 HTS-SF .+ 1.30" OD 11. 0.75- + 0.90" -OD 12 0.73 27 04/88 HTS-SF /' 29-53 04/88 H3 + 8.16" OD 12 0.74 "f, 29 109 04/88' HTS-SF + 0.60"- OD 15 'O.56-1.00" OD. 13 0.58 30 .114 04/88 HTS-SF- + '30'- 116 04/88' HTS-SF + 0.60" -OD 12-1.06 0.90" OD 12 'O.72 30- 128- 04/ES. HTS-SF + 32.90" OD 19 0.52' 30- 130 04/88 H4 + 32-28 04/88 CTS-SF + 6.58" OD 10 1.46' 32-36 04/88 H2. + 11.50" OD 17-0.52 32-126 04/88 HTS-SF 4 0.80" OD 12 0.90 33-109 04/88 HTS-SF + 0.80" OD 11-0.69 33-111 04/88 HTS-SF +4 1.00" OD 15 0.81: 35--127 04/88 HTS-SF + 1.00" OD 16 0.51~ 39.117 04/88 HTS-SF + 1.30" OD 18 0.65 40-48-04/88 HTS-ST + 1.20" OD 19 0.40 .42-114 04/88 HTS-SF + 2.80" OD 17 0.81 42-120 04/88 HTS-SF + 1.50" OD 10. 0.75 43-53- 04/88 HTS-SF '+ 2.34" OD 11 1.10 43-111 04/88 HTS-SF + 1.60" OD 13 0.49. 43-119 04/88 HTS-SF + 1.70" OD 12 0.59-44-110 04/88 H5 - + 6.10" OD 17 0.83 44-114 04/88 HTS-SF + 2.70" OD 13 1.25 04/88 HTS-SF + 2.60" OD 15 1.24 46 -116 04/88-HTS-SF + 2.80" OD 15 0.76 46-158 04/88 C4 + 27.20" OD 17 0.45 47-103 '04/88 HTS-SF + 0.90" OD 12 0.59 49--103 04/88 HTS-SP + 0.90" OD 17 0.55 49-105 04/88 HTS-SF + 1.00" OD 17 1.00 1 50-58 04/88 HTS-SF + 2.66" OD 12 0.74 52-58-04/88 HTS-SF + 1.09" OD 16 0.83 04/88 HTS-ST + 1.79" OD 12 0.83' 53-65 04/88 HTS-SF + 1.90" OD 10 0.95 54-70 04/88 HTS-SF + 1.30" OD 11 0.95 55-69 04/88 HTS-SF + 1.70" OD 11 1.09 ' I. 55-111 04/88 HTS-SF + 2.40" OD 17 0.86~ ii n- ._n a E ' Plants CALVERT CLIFFS: UNIT'1 S t e n n. Generater: 11 l' r ~. Outage: 04/88 ~ M L QUERY r T OD,4 20 it TW,ALL VOLTS,ALL ELEV= FALL TUBES),ALL-RL. ,g. ' (V)n f ROW'-LINE 'OUTAGF' ~FLFVATION INDICATION =t TW -VOLTS -1.70" OD

16" 1. 15 56--

68 04/88 ' HTS-SF + 56-112 ~04/88 HTS-SF +- 1.90" OD. 17' '1. 00 57-59- 04/88 HTS-SF- + 0.70" OD 10 0.9 57-61 04/88 HTS-SF' + 1.90" OD 15 0. 45 57-67 04/88 HTS-ST + 1 70". .OD 12 0. 65 57 :'105' 04/88' HTS-SF + 2.10" OD 15 0. 73 57-109_ 04/88' HTS-SF + - 2. 7 0 "- OD ~ 17 _0. 7e 04/88 HTS-SF + 2.30" OD 10

1. 6 f 58-58 04/88 HTS-SF

'+ 0.70" OD 13 < 0.- 41 58. 64- 04/88 HTS-SF + 2.00"- OD 11

0. 6f

.n

58-70 04/88 HTS-SF

+ 1.00" OD 13 0. 35 59 ~59. 04/88 HTS-SF + 1.80" OD' 16

1. 3(

04/88 HTS-SF + 2.70" OD 10 ' O.8 59-61 04/88 HTS-SF + 2.10" OD-13- - 0. 4 t 60-58 04/88 HTS-SF + 1.20"

OD 12
1. 4 '

61-65 04/88 HTS-SF + 1.00" OD 10-

0. 6?

61-67 04/88 HTS-SF + 1.60" OD 12 - 0. 62 1.70" OD 13

1. 0(

61-71-04/88 HTS-SF + 18.73" OD-16 ' 0. 8' 62-58 04/88 C2 + 11 I. 2( 62-66 '04/88 HTS-SF + 0.30" OD 62.102 04/88 HTS-SF 4 2.20" OD 13 0. 71 63- '69 04/88 HTS-ST. + 2.20" OD 0. 5l 64-56 04/88- -H4 + 18.60" OD '12

0. 5[

+ 1.90" OD 13 .- 0. 9; 65 - 69 04/88 HTS-SF 1.20" OD '15 . 0. 6t '04/88 HTS-SF + 89 04/88 HTS-ST + 0.80" OD 16

0. 6'

+ 2. 8 0 ", OD lo'

1. 2{
65-93 04/88 HTS-SF

~ + 1.80" OD 18

1. 7, 66-68 04/88 HTS-SF 66 - 70 04/88 HTS-SP

+ 1.90" OD 12

0. 7, 66-72 04/88 HTS-SF

+ 1.80"- OD 15

0. 9f 1.80" OD 16 1. 01 66-74 04/88-HTS-SF'

+ k'#b 68-70 04/88 HTS-SF 2.70" ' OD 17- ~ 1. 2, 66-80 04/88 H3 + 5.10" OD 11

0. 6 r

+ 68-. 72 04/88 . HTS-SF + 1.90" OD 10 0. 91 1.60" OD 18-0.8 69-69 04/88 HTS-ST + 69-71 04/08 HTS-SP + 2.40" OD 19 0.6 69- '93 04/88 HTS-SF + 0.50" OD 13

1. 2; 70-68.04/88 HTS-SF

+ 1.20" OD '12

0. 6' 71. 43 04/88 H3-

+ 18.38" OD 17

0. 6' 71-91 04/88 HTS-SP

+ 0.80" OD 19

1. @l 71-95 04/88.

HTS-SF + 2.50" OD 12 2.1: 72-30 04/88 C1 + 26.63". OD 12 0.9 72-72.- 04/88 HTS-PF + 1.40" OD 19 0. 01 72-152' 04/88 H3 + 32.20" OD 15 0. 7, 73- '29 04/88 DC OD ' 13 ' 2.' 73-93 04/88 HTS-SF + 1.20" OD 13 1. .74-- 50 04/88 C1 + 13.43" OD .12 0. 7. 74-- 92 04/88 HTS-SF + 2.70" OD 15 2. 18

1. -

75-

15. 04/88 C1

+ 15.79" OD 76-92 04/88 HTS-SP + 1.50" OD 13 1. 76-114 04/88 C1 + 10.60" OD 10 0. 76-132- 04/88 H5 + 27.90" OD 17 0. 04/88 H4 + 20.40" OD 19 0. 78+ 84 04/88 HTS-SF + 1.40" OD 12 1. 81-87 04/88 H4 + 3.20" OD 13 0. 86-- 38 04/88 HTS-SF + 1.00" OD 19 0. 86--100 04/88 HTS-SF + 16.30" OD 16 0. 91-141 04/88 H3 + 36.80" OD 17 0. 92-72-04/88 C2 + 15.70" OD 19 1. 93-.25 04/88 VH + 26.62" OD 7 0. 93-81 04/88 H4 + 15.10' OD 12

0. 54 04/88 H7

+ 14.41" OD 15 0.- 95-125 04/88 H3 + 29.50" OD 12 0.0 ~98-46 04/88 C1 + 18.60" OD 16 0.@ 17.30" OD 10 0.@ 99 - 73 04/88 VH + f~N O 1

CALVEX IFFS UNIT I Steam Ger,erator: 11 QUERY: OD,*:20 t TW,ALL VOLTS,ALL ELEY (ALL TUBESy,ALL.yL s

POW-LINE OUTAGF FLFVAT!aN IND! CATION % TW VOLTS 14.00" OD 13 0.70 100-70 04/88 C4 + 16.90" CD 1? 0.70 103-83 04/88 H5 + 20.90" OD 1d 0.55 104-140 04/88 C3 + 105-93 04/88 C4 + 3.20" OD 19 0.53 105-101 04/88 C4 + 20.10" OD 16 0.71' 12.60" OD 10 0.82 106-76 04/88 DH + 115-109 04/88 H8 + 19.70" OD 19 0.65 115-121 04/88 CTS-SF + 35.70" OD 11 0.79 128-80 04/88 H4 + 21.60" OD ll 0.81 129-81 04/88 DH + 10.80" OD 13 0.43 133-81 04/88 C6 + 21.80" OD 13 0.66 TOTAL TUBES: 135 I ~. I v h ,q I w~_; } ) o STEAM GENERATOR'11 C. List with Plot of 20%-39% Indications O l O i' l A1 g i ...=En==...= m =t s =. .,s .a s a . -) 'E m .- l E 6- . g( = 9 1 5 9 8 4 1 R E = N 7 G ) I 4 0 S 1 S S A E 5 B: S 4. E E I ) TW S G R ( A.. A LS o T AY c LA TA = T U OT O TS 8 T O - g 8 8 o m A- / = 4 '= S N A= s O u" A.. IT ,= = A A.. C I 1 .a 1 D r N 9 .a E I R C". ,'I.. I O S s ) T E I .a e A e D I 9 R 0 e D - (. r 3 E P 1 t 1 8 E .a f 0 S 0 0 -. e 2 1 L .a L .= f-A .a F .a O ~ = T .a = O L .a P 1 .v 1 1 .e G T S I .a M 4 L .a 9 S 3 m F 1( F .a u I N L O n C9 I e 8 T T/ A r .a C T. R4 ).I E0 1 Y 1D .s 1 L ( A E C 1L < P .a I g m E: - 7 T: G DU: NA 0N a ])L AT - = LU PO 0# ,n,. 3- , i.s - ,a.g gg8 1ljl 0.40" OD f 5-43 04/88 HTS-SF + 1.40" OD 5-111 04/88 HTS-SF + 6. 60 04/88 HTS-SF + 0.70". OD 8-108 04/88 CTS-SF + 1.00" OD 8-164 04/88 C4- + 18.40" OD 9-_ 57 04/88 HTS-SF. + 0.80"- OD 9-113 04/88 HTS-SF + 1.00" OD 11-27 04/88 VM OD 11-33 04/88 CTS-SF + 1.30" OD 11-113 04/88 HTS-SF + 1.10" OD 11-137 04/88 DH OD-11-147 04/88 VM OD 13-113 04/88 HTS-SF + 1.10" OD 16-110 04/88 HTS-SF + 1.10" OD 16-112 04/88 HTS-SF + 1.40" OD 18-120 04/88 CTS-SF + 1.00" OD 19-113 04/88 HTS-SF + 1.30" OD 20- 110 04/88 HTS-SF + 0.90" OD 33.00" OD 22-116 04/88 H1 + 23-15 04/88 HTS-SF + 5.10 " - OD 24-56 04/88 HTS-SF + 0.70" OD h 8.70" OD 26-122 04/88 CTS-PF + + 0.60" OD 29-111 04/88 HTS-SF 30- 110 04/86 HTS-SF + 0.70" OD 1.20" OD' 30- 112 04/88 HTS-SF + 26.90" OD 30- 144 04/88 C3 + 0.60" OD 31-119 04/88 HTS-ST + 0.90" CD 34-70 04/88 CTS-SF + 34-144 04/88 C4 + 27.40" OD 38-48 04/88 HTS-SF + 1.90" OD 39-51 04/88 HTS-SF + 2.20" OD 2.40" OD (3 42-52 04/88 HTS-SF + L 42-54 04/88 HTS-SF + 2.70" OD V 42-118 04/88 HTS-SF + 1.60" OD 2.00" OD ~ 46-52 04/88 HTS-SF + 2.60" OD 48-58 04/88 HTS-SF + 50-54 04/88 HTS-ST + 0.91" OD + 0.64" OD 50-56 04/88 HTS-ST 2.00" OD 51-63 04/88 HTS-ST + 51-111 04/88 HTS-SF + 0.80" OD 2.76" OD L 52-16 04/88 C4 + 52-58 04/88 HTS-ST + 2.55" OD 52-110 04/88 HTS-SP + 0.70" OD 52-114 04/88 HTS-SF + 0.60" OD 53-55 04/88 HTS-SF- + 0.61" OD 53-71 04/88 HTS-SF +' 1.20" OD 0.70" OD 53-113 04/88 HTS-SF + 54-56 04/88 HTS-SF + 0.64" OD 54-110 04/88 HTS-SF + 0.80" OD 55-59 04/88 HTS-SP + 0.80" OD 55-71 04/88 HTS-SF + 1.40" OD 56-58 04/88 HTS-SF + 0.79" OD 56-60 04/88 HTS-ST + 2.60" OD 56-106 04/88 HTS-SF + 1.70" OD 59-57 04/88 HTS-SF + 1.20" OD 59-97 04/88 HTS-SF + 1.20" OD 60-68 04/88 HTS-SF + 1.60" OD '61-9S 04/88 H3 + 30.60" OD 61-105 04/88' HTS-SF + 1.80" OD 63-105 04/88 HTS-SF + 2.00" OD 64-68 04/88 HTS-SF + 2.20" OD 64-102 04/88 HTS-ST + 1.80" OD 65-55 04/88 H3 + 1.24" OD 65-75 04/88 HTS-SF + 3.00" OD p. 2.40" OD 65-101 04/88 HTS-SF + f') \\vl L -m w-., y - __ Plant CALVERT-CLIFFS UNIT 1-Steam: Generator: 11

70uttget,

' =04/88; 11 h + x 9O QUERY: OD,20-39 SfTW,ALL VOLTS,ALL ELEV.(ALL TUEES1,ALL-RL l rg 4 j' I [_ OUTAGE ELEVATION-INDICATION 9 TW VOLTE y ( [ ^ ROW-LINE '65< 103 04/88 HTS-SF - 1.90" OD. 32 0.63- + 65-149 04/88 H4 + 34.20". 'OD~ 24 0.55 34.20" - -OD 21' O.73-04/88-H3 + 24 O.771 1.70" OD 3 7.' O.78 ; '66- '102. 04/88; HTS-SF .+. 15.50". OD ~66 150 04/88 DH + 10.20": OD 38 0.55 ~ ,=67 -81 04/88 C5. ~+ 68-94' 04/88 HTS-SF. + 3.00" OD 22 0.54c 69-85 04/88 HTS-SF +

1. 7 0 ".

OD 38' O.56' 70 70 04/88 HTS-SF + 1.50" OD 25 0.71 7 0-- 72--04/88 HTS-SF +

1. 9 0 " -

OD 22 0.62' 70 04/88 HTS-SF- + 1.20" OD 22 'O.84 70-78 '04/88 HTS-SF. + 2.10" OD 23 -1.14 70-82 04/88. . HTS-SF + 2.90" OD 23 0.48: ! 70 ' 08 04/88 HTS-SF~ + 3.00"- OD-34-0.69 0.80" OD 35 0.56: .70-

90. 04/88 HTS-SF

+- ,70-92.04/88 HTS-ST + --1.00" OD 23 .0.89 i 70-' 94 04/88 HTS-SF + -2.80" OD 26

1 ~. 2 4

_71-89- 04/88 HTS-SF + 0.60" OD-31 0.73. 04/88 HTS-SF + 0.90" OD 35 0.60 1.10" OD 31 0.91 71-93 '04/88 ' HTS-ST + 1.80" OD 28 0.47- '04/88 HTS-SF ~04/88 HTS-SF' + ~0.60" CD 23 2.721' 72-90 04/88 HTS-SF 0.60" OD 23 1.25 - 72-88 04/88 HTS-SF + O.60" OD 38 1.04- + 1.20" OD 34 1.15: 04/88 -HTS-ST + 9.70" OD 31 0.63 1 74-84-.04/88-HTS-SF + 1.00" .OD 23-3.75-l 74-88-04/88 HTS-SP + 75-83- 04/08 HTS-SP 3.10" OD 30 ,0.50 75-93 04/88 HTS-ST + 2.10" OD 38 1.04

76-90 04/88 HTS-ST

+ 2.10" OD 27

1. ~7 7 76---

98 04/88 HS + 5.00"- .OD 22 '0.58- - t'. .76 '132 04/88 H4 + 13.40" OD 39

0. 5 9.,

.\\ 04/88 H4 + 4.00"- OD-37

0. 5 8. ' 23 04/88 VM OD 31.

0.66 ~' 77 - 59-04/88' H6 + 13.95" OD' - 3 8.' O.63-77-- '67 -04/88 VE 4-23.29" OD -34 0.69 ! 1.60" OD 23 1.24 77- '85 04/88 HTS-SF + 77 - 87.04/88 HTS-ST + 0.90" OD 36 0.69q 1.00" OD '25 0.75 ' 77-89 04/88 HTS-SF + 04/88 HTS-ST + 2.50" OD 27 0.75 1 77. 111 04/88 H2 + 29.50" OD 38 0.51-78-22 04/88 C7. + 8.55" .OD 35 0.79: 78-90 04/88 HTS-SF + 1.20" OD 23 1.17 + 17.40" OD 24 0.571 79- .21 04/88 C1. + 1.70" OD 31 .1.21 ^ 79-89-04/88 HTS-SF 80-18 04/88 C1 + 19.75" OD 22 0.56-l 80-.80 04/88 HI + 29.40" OD 33 0.51 04/88 H2 + 18.40" OD 22 0.68 80-90 04/88 HTS-SF + 0.60" OD 32 0.61 i 80- 140 04/88 H4 + 24.80" OD 22 0.55i 81-85 04/88 H5 + 17.10" OD 24

0. 7 9. q 82-88 04/88 C3

+ 29.50" OD 35 0.62t 83-149 04/88 H2 +- 7.90" OD 25 'O.68' 84-116 04/88 CTS-SF + 20.70" OD 22. 0.50 l 86-46 04/88 C2 + 10.15" OD 39 1.07 86-110 04/88 C1 + 21.90" OD 28 0.52:) 04/88 C3 + 11.40" OD 22 0.57, 89-143 04/88 H2 + 15.80" OD 22 0.61i 90-22 04/88 C2 + 30.60" OD 22 0.50'1 92-30' 04/88 HS + 7.30" OD 25 0.84 92-108 04/88 HS + 8.20" OD 27 0.68 93-25 04/88 VM + 14.54" OD 32 0.54 95. 53 04/88 C4 + 28.00" OD 24 0.64 95-125 04/88 H5 OD 35 0.71 12.40" OD 26 0.64) 96-50 04/88 C7 + [/ \\ N - w. .m g.- 7 W !. : s IP15nts'CALVERT CLIFFS: UNIT 1. Steam Gen 6 atcrai11, + -?' l'

-.Ou t o g e s :

,04/88_ q_ QUERY: OD,20-39 3 TW,ALL VOLTS,ALL ELEV_(ALL'TUEES.1;Ati-EL (jn. (A f : ROW-LINE-OUTAGE 'ELEVAT!ON INDICA *S'*!> ' F TW VOLT 1 L5< 100 n 68- 04/88 C1 + 21.00" OD 29

0. 6;

-7.00"' OD 39.

0. 5; 101

,107, 04/88 ' H 2.

+1 Q;'S"",;

- 103-- 83 SO4/88 .H5 4.60" CD 26 ' O. St ( -+ 104/88-HS +. .8.30". 'OD' - 22

0. 7; V

6.40" OD, 27:

1. 0:

-104-132.04/88 H3 - ' +-37.80" OD 28'

0. 5'

- 105-93 04/88 . CTS-SF. OD 35 0 54 04/88- .Cl_ 12.80", OD 26 0. 81 y-04/88 C2' .+ 104/88' ' C2. +: 35.70" 'OD 35 0. 61 04/88 C3- +=37.70". OD 24 ' O. 5; 4- .106-s 88.04/88-VM +: 2.00". OD ' 23 , 1. 21 ' ~ 108-92 04/88 H7, + 24.40" OD- ' 37-0. 54 04/88 H8' +- 5.00" OD 32 0. 81 108.100l _04/88 H2 + 27.80"' OD 23 1.1: 'i. 114-126 04/88 DH- + 12.90" OD' . 23 . 0. 6l l116-118 04/88- 'C9 + 10.80" OD - 38 O'. 55 -117-87 04/88' DC: .+ 15;I0" OD-34 , 0. 5f e -122-54 04/88: HC 4' 18.50" OD .26 0. 61 0 '124 - 48 '04/88-H9 +. 5.50" OD 27

0. 5"

. 124 '114:'04/88' C3 +-34.40" OD 38

0. 5:

0(/88' C3 + 38.20" OD' 27_

0. 8 <

125-' 59 04/88-C3 + 16.60" .OD 22 ' 0. 7l 127-- 9 9 -' 04/88- .Cl + 33.90" OD ' 26-

0. 7; 04/88-

.C4 + 3.40" OD 33

0. 7;
128. 80. 04/88

-H4 + '24.40". OD 23 'O. 7( .128- ~118 04/88 C6. + 8.20" OD 33

0. 6l 129-65 04/88 H6 OD 0. 91 129-. 95 04/88

-C1 +.10.50" OD-21:

0. 6(

131-113 04/88 'VM' + 4.00"' -OD - ' 3 2..

0. 7; 0.80"
OD.

07:

0. 5(

133-67 -.04/88 CTS-ST + i. '. p) ' ' 133-71-04/88 H3- + 7.70" OD 35

0. 5; 133- :81 04/88-C6-

+ 11. 3 0 ": OD-34

0. 5' 138--

68 04/88' CTS-ST 4-10.40"_ OD ' 36-

0. 7; L ',C' -
139.;83 04/881 CTS-SF

+ 0.50" - OD 139 ' 1.1 : ~ p' ' ' 140- .80' 04/88 ' CTS-SF + 19.60" OD 28l

0. 6(

l ' l40- '88 04/88 C2-OD 38:

0. 6t

- TOTAL TUBES:' 149' p. t. W i ' 4 1 g7 L v p h hu O 4 STEAM GENERATOR 11 D. List-with Plot of >39% Indications O 6 O \\ ,l!1 !\\ l ^ e a-g W m m .# a m4.m,,=8 s g S s ys.5 ~ se 8 s 1 g e e s a. 1 g s t -. -. - - - _ - ~ - - - - - - - - - - - - - - 6 ,1 . _$3 6 y 9 1 5 1 8 2 4 tD E P 7 G I 4 m S S 3 A E e 4 B: S L) E E TW B ( t u 7 4 S LS n AY o L A TA A T 'A T OT O TS s T U O e 88 r i i / ^ 4 i i SN u i O I y T AC 1 i I 1 D i : N n o g R n s I O S T E i A o o 9 R 0 8 ~ u ~ 9 E 8 i N 1 ('N 3 E G oo E L L i A a i FO T O i LP i O 1 1 4 G 1 l, S T I i M L e S i l F e f F I t i L s t C8 8 7 T/ A i R4 C. r. o "e E0 V f i L nI A E C aL < P i I g - T. T: E oA G t NA n8 AT - = 3) LU PD oa ( 3.E5 g I gt.

  • l gg, l1 l;

l' g

~

m~ - -~ .n w- ,7 Plant s ' CALVERT : CLIFFS :' UNIT .- -: Sten 6 Cenerater:,1r

  • c Outages 04/88>

'1 u. u 'i ['.. 'QUER :/OD))?9 ITW,'ALL VOLTS,ALL ELEY'(ALL=TUPEST,ALL-RL: I ,,u.g 9 },f f.

ROW-LINE YOUTACF FLFVATION INP! CATION-t ' T W '-

VOLTT ~ '11'-.1147' 0'4/88 DH' 0.644 +- 2.10" OD-57 1 32.80"-- OD: 59 0.Eti 33-04/881 C O '. .27.--' 51: 04/88' HTS-SF 1+~ 0.76" OD. . 48

. 0. 7 2. !

+ 45'-'

55 04/86'

' HTS-SF '+, ' 1. 0 3 ".. OD 52- '1.3:! 45-54- -58 04/88-HTS-SF -+. S. 6 7 "a OD 47 0.65) 50 16 04/88L H4 ' - 5 5 ~- - 57c-04/88 . HTS-SF ' +

0. 8 2"-

OD . 64 0.57 +- 0.64"- OD-4 8 -- 2.60 ~69-. 93 .)4/86 HTS-SF, ' + 1.10"- OD 61 '0 65! s70-92 -04/88 ' HTS-SF- + 0.80"- OD 48 3 0.9E! 44 '1.5El 171- '83l 04/88' HTS-SF. +.. 0.70"- -OD 1 1.13l 73-89-04/88. HTS-SF-- + 0.50" LOD - 47 .1'. 0 f -17 4 ' 86..04/88 HTS-SFf + -

0. 6 0 "-

OD ' 49 , s -92: 04/88. HTS-SF- +. 0.60" ~ OD. 62-1.191 75-'~85 04/88 HTS-SP + 0.70"- OD -'4 b 2.2C' 75-' 93 04/881 HTS-SF + ~2.80" OD-41 '.1.4Cl 77-1 89.04/88 HTS-SF + 1.80" OD - 43: l '. 5 E 103-_125.04/88f VH . + .1.40"- LOD 42: L1.2C 78-88-04/88 HTS-SF '234.108. 04/88- . HTS-ST .+ 10.60" OD- . 54 'O.53 OD. 48- .0.93 . 56 0.4E 138-7604/88:. CTS-SF-' 10.60"' 'OD ..4*' 0.74J 136-: 6804/88 CTS-SF1- + 11.00" OD + L TOTAL TUBES: 21 i l i l l 2 h s )y/7 1 I t i l: 'l i i l u' i i t i b 1 'l I > Ii ( l STEAM GENERATOR 11 E. List with Plot of Distorted Indications 5 O } g,. . g.7,. - " m,, ~s m= =.,. s e 9 5., 8 0 e 6. n2 0 0 s 3 1 1 i i t 1 1 1 'E m l .a3 " a.. g ,\\ e.. 9 1 5 3 6 1 8 R E p 7 e I 4 8 -S 8 A E 4 B: SE t ) Te 5 E ( 1 7 4 G LS AY l A TA T 4 A T OT O TS T UO 4 8 4 8/4 S s N O I T O G A t C 1 p .u C 1 I I T D AC .a N I u R W I O p m s T I .a e A E ,\\ D R L n o E E P N I .a T E T R S L t M .e O = T m S .e ID ,{ .a = F t .a O T .a O L .a P .e 1 1 a .e 1 G T S I .a N a U S .a m FFI .a u L s ) e C8 1 8 1( r T/ u .a T R4 e E0 = V D .s L D A E C T .a R n U m T: E: N T G NA D m yY AT = LU ~,Y PO D ,iag 1 s I 1= - -, g g g0 il.l1llll!1l ll (l ~._ Plant:'CALVERT CLIFFS UNIT 1-Steam-Generator: 1 .Outager-04/88; OUERY:.DISTORTD,ALL ELEV (ALL TUBES),ALL-RL v/. - -ROW-LINE'20UTAGE ELEVATION INDICATION i s 0.80" DISTORTED':IND 21-57 04/88 CTS-SFL 0.80" -DISTCRTED IND 04/88 HTS-SF' + 42-2 0.. 04/88 H2' + 21.30" DISTORTED IND' 56- '60 04/88 HTS-SF + 2.30"- DISTORTED IND 14.19" DISTORTED IND 58 10' 04/88 CTS-SF + + 1.20" . DISTORTED IND h 59-

57. 04/88 HTS-SF-

'+ 0.70" ' DISTORTED IND 60-- 60 04/88 HTS-SF- ~60- ,64-04/88 HTS-SF + 2.10" ' DISTORTED IND 04/88 HTS-SF +- 2.60"- DISTORTED IND 60-70. 04/88.

HTS-SF

~ +: 1.60" DISTORTED IND 62-76-04/88 H2- + 22.60". DISTORTED IND 72-~ 44 04/88 H5 + 9.84" ' DISTORTED IND l 75 ' 71 -04/88 VC' DISTORTED IND '85-211 04/88 C5' + 4.80" DISTORTED IND rL' 86-42 04/88-H3 +-29.30" DISTORTED IND a L TOTAL-TUBES: 13-1 r .)- s O I STEAM GENERATOR 11 i } F. Lists with Plots of Tubes not Rolled l' j O l l l I Y ,i 1 e 9 l, ,,, s ' s,... - - =. n,,., 1 ~ __= s, 5, ,,, 7 ' a, .5 3, ",.a,,,.,.. p;7 +LL i P3, 'G 1, ).

  • g, b,-

E D <N L_ 0 9 'a 9 l 2 i 1 5 3 8 1 ~ t IEN F G I 4. S

S SA EB:

4 3 U) Tf tt f u LS T AY L TA AT k. OT O TS T A. t 1_ e e L_ _. .I i= hs e 3= - s b u 4a T

Qj T

O T p H 1 .a 1 t a ~ a t F O E f-G S T D . a E ,.,g) E RA D N I 0 L E 8 L .,1N L EN 1 . a . e O G R ,4 _ T . a O N . a s e . a b u a 3_ T . a e . e 1 T I a N 'A U a S S F E F 3 TA I a L ) L 3 W C8 1( E 8 T/ . s. T 8 R4 8 T E0 / O V 4 H s L 0 A C a e g o G E t E

TG u

D NA O 0 .T1 AT 7 LU 2 PO S Eg. s,. ["a !1 ,a f _A g g. ll i, l. lll .lil --n n.- - .-.v.-. Plant: CALVERT CLIFFS UNIT 1 S t e a n. - G e r. e r a t s : - 11 Outage: 04/88 Tuber NOT FOLLED at HOT Tubesheet ,e 1 -ROW LINE s 29 165 100 2c '! O O 28 102 28 119 87 139 75 139 79 139 83 139 85 139 87 139 89 139 93 139 95 13 Outage : 04/68 Total = s O o <- S40tf -> ggg3.gsgggsa aee'sasaeeaaea s= ,__ s ,/ ,g i R-S r _ e, l g.- n - si l -= ~ l {" - se 65 -w m e. - 8C s E. ) c, 4 12 4 -a un ~ sm e-l l. . e, o ll m i, i C) j - l C }!il l 1. ! - as u) +-: I m i i . os C el j; l D 2 _m f!!;!'l l ' f. l Q - se a ~: I l l O -e l I - se 0 6 I A U ys ,gg 'f m i , ~s g g;.

  • j i

). o a I k l -m l .I a L' W-W o l l ! I .J C1 g: . I - as ] .J S i i t I l I k . as i i i I I i 4r H l = O l l E l I l l \\ u) -es m 1 l c3 .-ers i c F- 'I i l es l t t .e

  1. I H

e H MI m m -8P 3 ( 3 g dg s + -s g r I Eg ! I 8 n) s 8 .t. 28 I ... a m i=44m e um ma -== - Plant: CALVERT CLIFFS UNIT 1 Steam. Generator: 11 Outage: 04/68 Tubes NOT ROLLED at COLD'Tubesheet l ROW .LINF i 22 '166 . 'g_- 67 231 0 Outage r,04/88 Total = i 'l s f.~. i i 1 I' l STEAM GENERATOR 11 G. Lists with Plots of Sludge Data O l O I y i } 3 =., e 8 e 8 , - s. ~... s.. " .., s.. e 5 e a 1 t 0 s. t 1 1 9 1 I .E ,33 *' 3 e n, n 9 g a 1 5 1 8 12 tD g lm E a 7 P a O t I 4 S 4

S a>

SA E B: 5 rr E I ) TW ee e mo t ( u 7 LS

i. L E

AY ms L A TA T G OT O g TS es T AT UO y g 88 4. /4 ,= a s,- G E L T 1 .a O 1 H e oa .a s R tc 1 O O 1 T s4 .a e A R n G E rr o 7 ea .a S E u 'm c ~ G a= N .e I a4 .e -{ THG .a j1 I .a EH .a EG .a D UL .e S 1 .e T I .a W -A S .a s ) F 0 e F 1 r L s .a u I t t s C8 I 8 T e T/

o e A T

osC .a R4 sui r E0 W e Y s L' <aD .a A E C L rrP .s u eeI mmT n T:E i u l. e L e G NA msM m AT LU ,pk PO os# 1,3g i g I g& .a i a g gI y 37,n n- .' P l a n t : CALVERT. CLIFFS-ONIT.15 SteamsGenerator: 11T ' Outage: 04/88.- l OUERY:.' SLUDGE,ALL~ INCHES, HTS-SF (ALL TUBES),ALL-EL 1 c.. 5 .l 1 l ROW-LINE ~ OUTAGE' # ELEVATION INDICATION' TNCHES 10k 30 504/88 HTS-SF.' SLUDGE-1- 10-c 40 04/88~ HTS-SF-SLUDGE l'

10-

'50-04/88: ' HTS-SF. SLUDGE. 110 - 60 04/88 -HTS-SP SLUDGE 3-10.110' 04/88~ HTS-SF SLUDGE 1 10- 120 04/88~ , HTS-SF SLUDGE 0. 10- 130 104/88 . HTS-SF SLUDGE- 'O 10-1140--04/88 HTS-SF SLUDGE-0- L 15-' 35 04/88 HTS-SF ' SLUDGE O' l' 15-45-'04/88. HTS-SF SLUDGE-1 15 .-55 04/88' HTS-SF SLUDGEJ 2- '15-105. 04/88 HTS-SF- . SLUDGE. I P 15-115-- 04/88-HTS-SF SLUDGE-0 .15-125 04/88' HTS-SF~ SLUDGE 2 l 15-135 04/88 . HTS-SF SLUDGE 2 L 20. 30 :04/88 HTS-SF-SLUDGE-1; o 20 - 40 04/88. HTS-SF SLUDGE 1. .20-: '50 04/88 HTS-SF SLUDGE. I 20-60 04/88 HTS-SF~ SLUDGE D '20-110' '04/88 HTS-SP SLUDGE 1 20- 120 .04/8,8'- HTS-SF SLUDGE 1 20-'150 04/86 HTS-SF SLUDGE 2' 20--140' 04/88 .HTSmSF SLUDGE. 0 25-. 35 -04/88 HTS-ST SLUDGE 1 '25-45-04/88 -HTS-ST SLUDGE. 1 25-55 04/88 HTS-ST SLUDGE 2 25-65 04/88. HTS-SP SLUDGE .1 25-105.04/88 HTS-SF SLUDGE 1 a 25-115- 04/88 HTS-SF SLUDGE 1-25-125 04/88 HTS-SF-SLUDGE 2 25-135 04/88 HTS-SF SLUDGE 1 jQ '30-30 04/88' HTS-SF SLUDGE I-4 f - 40 04/88. HTS-SF SLUDGE 1 f 'V 3 0--- l 5 0 04/88 HTS-SF SLUDGE

2

.30- '60 -04/88 HTS-SF SLUDGE I 70' 04/88 HTS-SP . SLUDGE -0 30-r J30- 100' 04/88 . HTS-SF. SLUDGE 0, 30- 110 04/88 HTS-SF SLUDGE l' 1 30- 120. 04/88 HTS-SF SLUDGE .I 30- 130 '04/88 HTS-SF SLUDGE 1 30- 140- 04/88 HTS-ST SLUDGE 2' 35- .35 04/88 ~ HTS-ST SLUDGE O '35- ~45' 04/88 ' HTS-SF SLUDGE 2 35-55' 04/88 HTS-SF SLUDGE 1 135-65 04/88 HTS-SF SLUDGE .1 35-75 04/88 HTS-SF SLUDGE 1 ~35-- 95 04/88 HTS-SF SLUDGE 0' 35-105 04/88 HTS-SF SLUDGE O 35-115 04/88 HTS-SF SLUDGE 1 35-125- 04/88 HTS-SF SLUDGE 1 35 ,135' 04/88 HTS-SP SLUDGE 2 i 40-30 04/88 HTS-SF SLUDGE O 40-40 04/88 HTS-SF SLUDGE 1 40-50 04/88 HTS-SF SLUDGE 3 40-60 04/88 HTS-SF SLUDGE 2

40-70 04/88 HTS-SF SLUDGE 1

40-80 04/88 HTS-SF SLUDGE 3 40-' 90-04/88 HTS-SF SLUDGE 1 40- 100 04/88 HTS-SF SLUDGE 1 40- 110 04/88 HTS-SF SLUDGE 1 40.120 04/88 HTS-SF SLUDGE 1 -l 40- 130 04/88 HTS-SF SLUDGE 1 40 140 04/88 HTS-SF SLUDGE 1 i 45-35 04/88 HTS-SF SLUDGE 1 45-: 45 04/88 HTS-SP SLUDGE 1 f w~;~ m m~,. n g - ~. JPlant:FCALVERT.: CLIFFS ~ UNITE 1 Steam Generater: 11 .d j Outage 04/88: ~ } ':t j 't, OUERY: ' SLULGs, ALL INCHES,HT S-ST t ALL !UBES), ALL-M

h l POW-LINE ~ OUTAGE ELEVAT VN INDICAT!ON-
NcHEr-j k

SLUDGE 1 45-55 04/88 HTS-SF - SLUDGE 2 - HTS-SF' 45-65.104/88 ' HTS-STL - SLUDGE

2. -.

45 - 75. 04/88 .4 5 -- 95 -04/88 .. HTS-SF SLUDGE 0' 45-85- 04/88: HTS-SF: SLUDGE- 'l i 45 105~-04/88-HTS-SF_ SLUDGE 1. i i 45115-04/88 HTS-ST SLUDGE-3 l~ 45-J125 ~04/88 HTS-SF SLUDGE 2 L 45-'135-04/88 HTS-SF SLUDGE 1. 4 50-30'.04/88 HTS-SF SLUDGE 1 50-- 40 '04/88: HTS-SF-SLUDGE 1

(

50 ' -50 04/88 HTS-SF. SLUDGE 2 50-: 60- 04/88 HTS-SF SLUDGE 2 50-;'.70 04/88 HTS-SF-SLUDGE-2 50-80 04/88 HTS-SP SLUDGE 3: f 50-90 04/88. - HTS-SF SLUDGE 1 '50-100 04/88 . HTS-SF- . SLUDGE 1. 50- 110 04/88 HTS-SF -SLUDGE 1 50- 120- 04/88. HTS-SF-SLUDGE 2 50- 130--04/88-HTS-SF-SLUDGE 1 '50-El40 '04/88 HTS-SF SLUDGE O ,55-35' 04/88- - HTS-SP SLUDGE 1 55-45 04/88 ' HTS-SP SLUDGE l' 55-55.~04/88 - HTS-SF SLUDGE -2 55 - 651 04/88-HTS-SF SLUDGE 3 55-75 J04/88: HTS-SF SLUDGE 3 55-- 85 04/88 HTS-SF SLUDGE 1 !55. 95. 04/88 HTS-SF SLUDGE 1. 55--105' 04/88: HTS-SF. SLUDGE O ~ 55 :115' 04/88 HTS-SF SLUDGE' 2 1 55-125- 04/88 HTS-SF SLUDGE O 55 -135' 04/88 HTS-SF SLUDGE 1 60-- 40 04/88 HTS-SF SLUDGE O \\ 60-50 04/88L HTS-SF SLUDGE 1 6 0 -: 60- 04/88' HTS-ST SLUDGE 2. 70: :04/86' HTS-SF SLUDGE -1 60-' 60- :80 04/88-HTS-SF SLUDGE 0 160-90 04/88~ HTS-SF SLUDGE 4 60.100,04/88 HTS-SF SLUDGE 2 60 :110- 04/88 -HTS-SF SLUDGE 3 60- 120 -04/88 HTS-SF-SLUDGE O~ l 6 0 - : 1.3 0- '04/88 HTS-SF SLUDGE 1 60 140 04/88 HTS-SP ~ SLUDGE O 65-35: 04/88-HTS-SF SLUDGE O HTS-SF SLUDGE O 65-45.04/88 65-55! '04/88 -HTS-SF SLUDGE J 65 - 65 04/88 HTS-SF' SLUDGE .2 65-- 75 04/88 HTS-SF SLUDGE 1 65-85'-04/88 HTS-SF SLUDGE 3 65-95 04/88~ HTS-SF SLUDGE O '65-105 04/88 HTS-SF SLUDGE O .65-115 04/88 HTS-SF SLUDGE 1 '65-125 04/88 HTS-SF SLUDGE 1 65-135. 04/88 HTS-SF SLUDGE 1 70-30 04/88 HTS-SF SLUDGE O 70-40 04/88 HTS-SF SLUDGE 1 70 - 50 04/88 HTS-SF SLUDGE O 70-60 04/88 HTS-SF SLUDGE 1 70 ; 70 04/88 HTS-SF SLUDGE 1 70-80 04/88 HTS-SF SLUDGE 3 70-90 04/88 HTS-SF SLUDGE 3

70-.100 04/88 HTS-SF SLUDGE 2

70 110 04/88 HTS-SF SLUDGE 1 70- 120-'04/88 - HTS-SF SLUDGE 1 I' 70- 130 04/88. HTS-SF SLUDGE 2 u... ,,x---,-----.-- _L.-- --.-_-----,---_.----_w--.__--


_____----------------._x------.-

_-.-----_---------------------_--.----------------.-u--

...... c.: u.3.,,.. 2. ............,.., n ;i.., e.,ie........ e.ecce...i co, cc,...... Page; Plant: CALVERT CLIFFS UNIT 1 Steam Ger.e ator: 11 ) Outage: 04/88 l QUERY: SLUDGE,ALL INCHES, HTS-SF rALL TUBES),ALL-RL I L (,/ - ROW-I.!NE OUTAGE ELEV A T I N! TNDICAT!ON INCHES 70- 140 04/88 ' HTS-SF SLUDGE O 75-35 04/88 HTS-SF SLUDGE 1 75-45 04/88 HTS-SF SLUDGE 1 75-55 04/88 HTS-SF SLUDGE O 75-65 04/88 HTS-SF SLUDGE 0 75-75 04/88 HTS-SF SLUDGE '3 75-83 04/88 HTS-SF SLUDGE 1 '75-85 04/88 HTS-SF SLUDGE 4 75-95 04/88 HTS-SF SLUDGE 2 75-105 04/88 HTS-SF SLUDGE 1 75-115 04/88 HTS-SF SLUDGE 1 75-125 04/88 HTS-SF SLUDGE 2 75-135 04/88 HTS-SF SLUDGE O 80- '30 04/88 HTS-SP SLUDGE O 80-40 04/88 HTS-SF SLUDGE 1 80-50 04/88 HTS-SF SLUDGE 1 80-60 04/88 HTS-SF SLUDGE O 80-70 04/88 HTS-SF SLUDGE 1 80-80 04/88 HTS-SF SLUDGE 2 80-90 04/88 HTS-SF SLUDGE 2 80- 100 04/88 HTS-SF SLUDGE 2 80- 110 04/88 HTS-SF SLUDGE 1 80- 120 04/88 HTS-SF SLUDGE 1 80- 130 04/88 HTS-SF SLUDGE O 80- 140 04/88 HTS-SF SLUDGE O 85-35 04/88 HTS-SF SLUDGE O 85-45 04/88 HTS-SF SLUDGE 1 85-55 04/88 HTS-SF SLUDGE 1 85-65 04/88 HTS-SF SLUDGE 1 85-75 04/88 HTS-SP SLUDGE 2 I 85-85 04/88 HTS-SP SLUDGE 2 l /~N 85-95 04/88 HTS-SF SLUDGE 2 ( 85-105 04/88 HTS-SP SLUDGE 2 x-85-115 04/88 HTS-SF SLUDGE 1 85-125 04/88 HTS-SF SLUDGE 1 85-135 04/88 HTS-SF SLUDGE O 90-30 04/88 HTS-SP SLUDGE O 90-40 04/88 HTS-SF SLUDGE O 90-50 04/88 HTS-SF SLUDGE 1 90-60 04/88 HTS-SF SLUDGE 2 90-70 04/88 HTS-SF SLUDGE 1 90-80 04/88 HTS-SF SLUDGE O 90-90 04/88 HTS-ST SLUDGE O 90- 100 04/88 HTS-SF SLUDGE 3 90- 110 04/88 HTS-SF SLUDGE 1 90- 120 04/88 HTS-SF SLUDGE 1 90- 130 04/88 HTS-SF SLUDGE O 90- 140 04/88 HTS-SF SLUDGE O 95-35 04/88 HTS-SP SLUDGE O 95-45 04/88 HTS-SF SLUDGE O 95-55 04/88 HTS-SF SLUDGE O 95-65 04/88 HTS-SF SLUDGE 1 95-75 04/88 HTS-ST SLUDGE 2 95-85 04/88 HTS-SF SLUDGE 2 95-95 04/88 HTS-SF SLUDGE 1 95-105 04/88 HTS-SF SLUDGE 2 95-115 04/88 HTS-SF SLUDGE 1 95-125 04/88 HTS-SF SLUDGE O 95-135 04/88 HTS-SF SLUDGE D 100-30 04/88 HTS-SP SLUDGE O 100-40 04/88 HTS-SF SLUDGE O 100-50 04/88 HTS-SF SLUDGE O 100-60 04/88 HTS-SF SLUDGE 1 100-70 04/88 HTS-SF S L'.' D G E 1 100-80 04/88 HTS-SF SLUDGE 2 m m_ _ _ _ _. _ _ _ _ _

_. ~ ~_m -m e l Plant: CALVERT-CLIFFS UNITE 1 . Steam Generators-11"-

Outage

.04/88 };, j QUERY: SLUDGE,ALL INCHES, HTS-SF..-(ALL TUBES),ALL-RL-r, f i ROW-LINE OUTNGE ELEVATTON INDICATION -!NCHES ']%/ ' p 100: 90; 04/88 HTS-SF SLUDGE- .1 -100- 100 04/88'- HTS-SF SLUDGE O' 100- 110: 504/88- . HTS-SF' SLUDGE .1 100-'120: 04/88 HTS-SF SLUDGE O ~ 'l i 1 200 =130-04/88 HTS-SF

SLUDGE, IO-

-100.140 04/881 HTS-SF. SLUDGE O -105 - 04/88 HTS-ST ' SLUDGE Or l 0' .105-45 '04/88 -HTS-SF-SLUDGE 0' j 105-55' 04/88. ~ HTS-SF: -SLUDGE' 0' t -105- .65 =04/88-HTS-SF. SLUDGE-1 ,~ s t105-- '75 04/88. HTS-SF' SLUDGE 1. 't '105 .-85

04/88 HTS-SF SLUDGE 6.

105-95 04/88. ' HTS-SF . SLUDGE. 1 .) 105 105 04/88 HTS-SF. SLUDGE- .2 j 105-115 04/88 . HTS-SF. SLUDGE ~0-105-135 04/88 HTS-SF SLUDGE- .0' j TDTALSTUBES: 211 L .I^i r i O. i I i [; .-j

f 1

,s: g: f

~~ i_ljL. d I~ + - 9 1 5 0 8 1 2 t t i E )9O N 7 2( G ( I 4 S S: 2> S E A B: S U) EE E 9G B TW 2E U y t t T ~LS LL AY SS L E A 4 T A = - T G OT O TS R5 T A T U O r_ 8 a_ / L 8 4 e_ 4 i -, F 1 G E i. 1 1 i L L ) 1 h O 2 D 1 1 1 w 2 ) C t A_. F (( Y. \\l O W / 1 T 1 4 A N e A 1 R M. D. _. + f E E E .\\ N G 6 G E D D G. e_ U U Cm S G i 1 L L 5 S t = N 1 4 I r. o_ ~ T H p G I s E 3 o q H m E G D ~ U L S 1 T INU j F ) s S F 4 ~ 0 ( I l L u f C8 I T 8 ) 1 A T/ E0

15) C R4 7I

( O V 1< 3D L A - - E C L EEP GGI E: DDT UUL TG LLU NA SSM \\j AT

=

LU p' \\Q PO 03a L ,= 3 g g .~ ,I j * &

  • f y

~

y. -

....<........... m.... _. ...... m, y ..............f..............,.,..- .Flant's,CALVERT CLIFFS UNIT'1 S t e s:n Ocr. ora or: 11 )

Outaget 04/88

{ 'w -QUERY: SLUDGE,ALL INCHES, CTS-SF IALL TUBES),ALL-RL i. /. d-ROW-LINE OUTAGE FLFVATION INDICAT!ON INCHFr

pi 10-

.40 '04/88 CTS-SP SLUDGE o 10-' .50 04/85 CTS-SF SLUDGE O 10-60. 04/88 CTS-EF SLUDGE 1 10- 110 :04/88 CTS-SF SLUDGE 2 '10-120 04/88' CTS-SF SLUDGE 1 '10--130.04/88 CTS-SF SLUDGE 2 10- 140 04/88. CTS-SF SLUDGE 2 15-

35. 04/88 CTS-SF SLUDGE 3

15-45' 04/88 CTS-SF SLUDGE 3 15-55 04/88 CTS-SF SLUDGE 3 15-105 04/88 CTS-SF" SLUDGE 4 15-115 04/88 CTS-SF SLUDGE 1 15-125 04/88 CTS-SF FLUDGE 2 15-135 04/88 CTS-SF SLUDGE 2 20-30: '04/88 CTS-SF-SLUDGE 1 40 04/88 CTS-ST SLUDGE 2 20-50 04/88 CTS-SF SLUDGE 2 20-60 04/88 CTS-SF SLUDGE 3 20- 110 04/88 CTS-SF SLUDGE 2 20- 120 04/88 CTS-SF SLUDGE 2 20- 130 04/88 CTS-SF SLUDGE 3 20.140 04/88~ CTS-ST SLUDGE 2 25-35 04/88 CTS-SF SLUDGE 1 25-45 04/88 CTS-EF SLUDGE 1 25-55 04/88 CTS-SF SLUDGE -0 25-65 04/88 CTS-SF SLUDGE 3 25- '105 04/88 CTS-SP SLUDGE 2 25-115 04/88 CTS-SF SLUDGE 1 25-125 04/88 CTS-SF SLUDGE 1 25-135 04/88 CTS-SF SLUDGE 1 k 30-30- 04/88 CTS-ST SLUDGE 1 /m* 30-40 04/88 CTS-SF SLUDGE O lj= 30-50 04/88 CTS-SF SLUDGE 1 30-60' 04/88 CTS-SF SLUDGE 1 h-. 30-- 70 04/88-CTS-SF SLUDGE O 30- 100 04/88 CTS-SP SLUDGE 2 110 04/88 CTS-SF SLUDGE 1 30-'120 04/88 CTS-SF SLUDGE O 30- 130' 04/88 CTS-SF SLUDGE 1 30- 140 04/88 CTS-SF SLUDGE 1 35- 04/88 CTS-SP SLUDGE 1 35-45 04/88 CTS-SF SLUDGE O 35-55 04/88 CTS-SP SLUDGE 1 35-65 -04/88 CTS-SF SLUDGE 2 35 - 75 04/88 CTS-SF SLUDGC 2 35-- 95 04/88 CTS-SF SLUDGE 2 35-105 04/88 CTS-SF SLUDGE O 35-115 04/88 CTS-SF SLUDGE 1 35-125 04/88 CTS-SP SLUDGE 2 35-135 04/88 CTS-SF SLUDGE 1 40-- 30 04/88 CTS-SF SLUDGE 1 40-40 04/88 CTS-SF SLUDGE 1 ~ 40-50 04/88 CTS-SF SLUDGE 1 40-60 04/88 CTS-SP SLUDGE 1 40-70 04/88 CTS-SF SLUDGE 1 40-80 04/88 CTS-SP SLUDGE 2 40-90 04/88 CTS-SF SLUDGE 2 40- 100 04/88 CTS-SF SLUDGE 2 40- 110 04/88 CTS-SF SLUDGE 1 40- 120 04/88 CTS-SF SLUDGE 1 40- 130 04/88 CTS-SF SLUDGE 1 40- 140 04/88 CTS-ST SLUDGE 1 45-35 04/88 CTS-SF SLUDGE 1 45-45 04/88 CTS-SF SLUDGE 1 45- '55 04/88 CTS-SF SLUDGE 1 )%. U'

...... p y ...,,..........,m.....mn Plant: CALVERT CLIFFS UNIT 1 Stean. G e r.e r a t o r : 11 Outage _04/88 OUERY: SLUDGE,ALL INCHES, CTS-SF (ALL TUEES),ALL-EL p 1 ~ \\j ROW-LINE OUTAGE ELEVATION INDICATION INCHEF 45-65 04/88 CTS-SF SLUDGE 1 45-75 04/88 CTS-ST SLUDGE O 45-85 04/88 CTS-SF SLUDGE 2 45-95 04/88 CTS-SF SLUDGE .1 45-105 04/88 CTS-SF SLUDGE 1 45-115 04/88 CTS-SF SLUDGE 1 45-125 04/88 CTS-SF SLUDGE 1 45-135 04/88 CTS-SF SLUDGE 2 50-30 04/88 CTS-SF SLUDGE 1 50-40 04/88 CTS-EF SLUDGE 1 50-50 04/88 CTS-SP SLUDGE O 50-60 04/88 CTS-SF SLUDGE 1 50-70 04/88 CTS-SF SLUDGE 1 50-80 04/88 CTS-SF SLUDGE 1 50-90 04/88 CTS-ST SLUDGE 1 50- 100 04/88 CTS-SP SLUDGE 1 50- 110 04/88 CTS-SF SLUDGE 1 50- 120 04/88 CTS-SF SLUDGE 1 50- 130 04/88 CTS-SF SLUDGE 1 50- 140 04/88 CTS-SE SLUDGE 1 55-35 04/88 CTS-SF ELUDGE 1-55-45 04/88 CTS-SF SLUDGE 1 55-55 04/88 CTS-SF SLUDGE 1 55-65 04/88 CTS-SP SLUDGE 1 55-75 04/88 CTS-SF SLUDGE 1 55-85 04/88 CTS-SF SLUDGE 1 55-95 04/88 CTS-SF SLUDGE 1 55-105 04/88 CTS-SF ELUDGE 1 55-115 04/88 CTS-SF SLUDGE O 55-125 04/88 CTS-SF SLUDGE O ,d 55-135 04/88 CTS-SF SLUDGE 1 T 60-40 04/88 CTS-SF SLUDGE 2 ('/ 60-50 04/88 CTS-SF SLUDGE-1 60-60 04/88 CTS-SF SLUDGE 1 60-70 04/88 CTS-SF SLUDGE 1 60-80 04/88 CTS-SF SLUDGE O 60-90 04/88 CTS-SF SLUDGE 1 60- 100 04/88 CTS-SF SLUDGE 1 60- 110 04/88 CTS-SF SLUDGE 1 60- 120 04/88 CTS-SF SLUDGE O '60-130 04/88 CTS-SF SLUDGE 1 60- 140 04/88 CTS-SF SLUDGE O 65-35 04/88 CTS-SF SLUDGE 1 65-45 04/88 CTS-SF SLUDGE 1 65-55 04/88 CTS-SF SLUDGE 1 65-65 04/88 CTS-SF SLUDGE 1 65-76 04/88 CTS-SF SLUDGE 1 65-85 04/88 CTS-SF SLUDGE 1 65-95 04/88 CTS-SF SLUDGE 1 65-105 04/88 CTS-SF SLUDGE 1 65-115 04/88 CTS-SF SLUDGE 1 65-125 04/88 CTS-SF SLUDGE 1 65 '135 04/88 CTS-ST SLUDGE O 70-30 04/88 CTS-SF SLUDGE O 70-40 04/88 CTS-SF SLUDGE 1 70-50 04/88 CTS-SF SLUDGE 1 70-60 04/88 CTS-ST SLUDGE 1 70-70 04/88 CTS-SF SLUDGE 1 70-80 04/88 CTS-SP SLUDGE 1 70-90 04/88 CTS-SF SLUDGE 1 70- 100 04/88 CTS-SF SLUDGE 1 70- 110 04/88 CTS-SF SLUDGE 1 70- 120 04/88 CTS-SP SLUDGE 1 70- 130 04/88 CTS-SF SLUDGE 1 70- 140 04/88 CTS-SF ELUDGE O ,O a kj

_.. _ - _ ~. _ Flant:'CALVERTLCLIFFS UNIT 1 Steam Ger. era

11 Outage:
04/88 m

'OUEEY: SLUDGE,ALL !NCHES, CTS-SF'iALL'TUEES),ALL'-RL g LA. IND* CATION ' NCHES. ( ' ROW-LINE-OUTAGF' ELEVATION SLUDGE O 75-35 04/88 CTS-SF 75. 45 04/88 CTS-SF SLUDGE 2 75 : 5504/86 CTS-SF SLUDGE 1 75-. '65 04/88 CTS-SF SLUDGE 1 75-75-04/88 CTS-SF SLUDGE 1 75-83 04/88 CTS-SF SLUDGE 1 75-85 04/88 CTS-SF SLUDGE 1 r 75-95.04/88 CTS-SP SLUDGE 1 105' 04/88 CTS-SF SLUDGE .1 75-115- 04/88-CTS-SF SLUDGE 1 SLUDGE l-75-125' 04/88 CTS-SF 75-135~ 04/88 CTS-SP SLUDGE 0 80-30 04/88 CTS-SF SLUDGE 0 80-40 04/88 CTS-SF SLUDGE O 80-50 04/88 CTS-SF SLUDGE 1 80- ~60 04/88 CTS-SP SLUDGE 2 80-70-04/88 CTS-SF-SLUDGE 1 80-80 04/88 CTS-ST SLUDGE 1 80-90 04/88 CTS-ST SLUDGE 1 80- '100 04/88 CTS-SF SLUDGE 1 80- 310 04/88 CTS-SP SLUDGE 1. 80 120 04/88 CTS-SF SLUDGE 1 80- 130 04/88-CTS-ST ' SLUDGE O 80.140 04/88 CTS-SF SLUDGE O 85 - 35 04/88 CTS-SF SLUDGE O 85-45 04/88 CTS-ST SLUDGE 1 85-55 04/88 CTS-ST SLUDGE 85-65 04/88 CTS-SF SLUDGE 1 85- 04/88 CTS-SF SLUDGE 1 85-85 04/88 CTS-SF SLUDGE 1-I 85-95 '04/88 CTS-SF SLUDGE 1 p' 85-105 04/88 CTS-SP SLUDGE l 85-115 04/88-CTS-ST SLUDGE 1 85 -125 04/88 CTS-SF SLUDGE O 85-135 04/88 CTS-SF SLUDGE O 90-- 30- 04/88 CTS-SF SLUDGE 0, 90-40 04/88 CTS-SP SLUDGE O 90-50 04/88 CTS-SF SLUDGE 1 90-60 04/88 CTS-SF SLUDGE 2 90-70 04/88 CTS-SF SLUDGE 1 90- '80 04/88 CTS-SF SLUDGE O 90-90 04/88 CTS-SF SLUDGE O 90- 100 04/88 CTS-SF SLUDGE 1 90- 110 04/88 CTS-SF SLUDGE 1 90- 120 04/88 CTS-SF SLUDGE 1 90- 130 04/88 CTS-SF SLUDGE O 90- 140 04/88 CTS-SF SLUDGE O C 95-35 04/88 CTS-SF SLUDGE O 95-45 04/88 CTS-SF SLUDGE O 95-55 04/88 CTS-SF SLUDGE O 95-65 04/88 CTS-SF SLUDGE 2 95-75 04/88 CTS-SP SLUDGE 2 95-85 04/88 CTS-SP SLUDGE 1 95-95 '04/88 CTS-51 SLUDGE 2 95-105 04/88 CTS-SF SLUDGE-1 95-115. 04/88 CTS-SF SLUDGE O 95-125 04/88 CTS-SF SLUDGE O 95-135 04/88 CTS-SF SLUDGE O 100-30 04/88 CTS-SF SLUDGE O 100-40 04/88 CTS-SF SLUDGE O 100-50 04/88 CTS-SF SLUDGE O 100-60 04/08 CTS-SP SLUDGE 1 100-70 04/88 CTS-SF SLUDGE 1 100-- 80 04/88 CTS-SP SLUDGE 1 -[ 100-90 04/88 CTS-SF SLUDGE 1 O j

~... ~ Plant: CALVERT CLIFFS UNIT 1 "tean. gem ratcr: 11 e Outage: 04/88 OUERY: SLUDGE,ALL INCHES, CTS-SF (ALL TUBES),ALL-RL ) (,r ROW-LINF CUTAGE ELEVAT;cN INDICATTON I N c y E r; 100- 100 04/88 CTS-SF SLUDGE 1 100- 110 04/88 CTS-SF SLUDGE 1 100- 120 04/88 CTS-SF SLUDGE O 100- 130 04/88 CTS-SF SLUDGE O 100- 140 04/88 CTS-SF SLUDGE O 105-35 04/88 CTS-SF SLUDGE O 105-45 04/88 CTS-SF SLUDGE O 105-55 04/88 CTS-SF SLUDGE O 105-65 04/88 CTS-SF SLUDGE 1 105-75-04/88 CTS-SF-SLUDGE O 105-85 04/88 CTS-SF SLUDGE O 105-95 04/88 CTS-SF SLUDGE O 105-105 04/88 CTS-SP SLUDGE 1 105.115 04/88 CTS-SP SLUDGE O 105-115 04/88 CTS-SF SLUDGE O TOTAL TUBES: 210 O) L_ 5 l w---_____.

l STEAM GENERATOR 11 H. List of Tubes Dented l l e - ~~~ ~----- _ _. _ _ _ _.., _ _ _ _ _ _ _ _ _ _ _ __

Plant:. CALVERT: CLIFES UNIT 1 St ear. Gene r at o r s.1~1 Outage: 04/88 OUERY: DENTS,ALL' MILS,ALL ELEV (ALL TUEESI,ALL-RL (D-N./ ROW-LINE OUIAGE-ELEVATION !NDICATION VOLTS ? 2- '148 '04/88 VM DENT 23 i< 23 04/88-VM DENT 7' '10-36 04/88 -VM-DENT 7 10-42 04/88' VM DENT >14 10-46 04/88 VM DENT 9 13-145 04/88-C6 + 8.30" DENT S 13-151 -04/88 C6 + 8.00" DENT 9 13-'155 04/88 C6 + 8.00" DENT 11 13-157. 04/88 C6 + 8.30" DENT- -11 04/88 VM DENT 6 13 161 04/88 C6 + 8.20" DENT: 12 13-167 04/88 H6 + 7.70" DENT 14 14-56 04/88, DH DENT 8 14-122- -04/88 H6 + 8.30" DENT 12 14-124 04/88 H6 + 8.60" ' DENT 7 15-3 04/88 DH DENT 14-75-5 04/88 DH DENT 9 15-7 04/88 DC DENT 8 15-9 04/88 DC DENT. 9 15-11 04/88 DC DENT 8 15-13 04/88 DC DENT 10 15-15 04/88 DC DENT 8 15-17 04/88 DH DENT 9 15-19 04/88 DH DENT 10 ' 15 - 21 04/88' DH DENT 11 ~15-23 04/88 DH DENT 11 '15-25 04/88 .DC DENT 7 15-27 04/88 DC DENT 22 15-33 04/88 DH DENT 6 15-35 04/88 DH DENT 7 15-37' 04/88 DH DENT 7 15-121 04/88 H6 + 8.30" DENT 16 4 15-123 04/88 H6 + 8.10" DENT 13 5.00" DENT 10 16-26 04/88 C5 + 16-32 04/88 DC DENT 5 ,16-40 04/88 DC DENT 17 16-42 04/88 DC DENT 9 16-44 04/88 DC DENT 10 20-30-04/88 HS + 16.10" DENT 8' 21-143 04/88 C3 + 30.80" DENT 6 27-35 04/88 C3 DENT 50

  • 27--

39-04/88 VM + 8.00" DENT 6 28-12 04/88 VM DENT 6 28-24 04/88 VM DENT 8 28-36.04/88 VM DENT 5. 28-44 04/88 VM DENT 8 s '28-56 04/88 VM DENT 15 j 29-15 04/88 VM DENT 11 1 '30-112 04/88 C2 + 11.00" DENT 6 30.122 04/88 HI + 13.30" DENT 13 04/88 HI + 12.70" DENT 6 31-3 04/88 VM DENT 11 31-' 5 04/88 VM DENT 7 31-7 04/88 VM DENT 7 31-11 04/88 VM DENT 10 31-15 04/88 VM DENT 9 31-17 04/88 VM DENT 10 31-19 04/88 VM DENT 8 31-25 04/88 VM DENT 7 31-33 04/88 VM DENT 10 31-51 04/88 VM DENT 6 31-57 04/88 VM DENT 6 31-137 04/88 VM DENT 5 31-139 04/88 VM DENT 8 31-157 04/88 VM DENT 7 O

.............,,,eee,',,ie,. ec,.......Pape 7, +...... u. tJe24.v,.n...............,., 2,.'.... Pland:.CALVERT, CLIFFS UNIT 11' Steam-Generator: ill ,:0utages; l04/88' y 1 QUERY: DENTS,ALL MILS,ALL ELEV.(ALL TUPES),ALL-RL , [\\[. A row-LINE-ottT AGE ELEVATION INDICATION VOLTS _., 31-161 04/88 VM DENT 7 31 ~163' 04/88 VM DENT 7 J 34 146- 04/88-DH + - -' 7.10" DENT 6,

32-140- 04/88 C4

+ 8.60" DENT ST L 34-.156. 04/88 VM + 3.90" DENT 23 3 5 ~- 61' 04/88 VM DENT 6 35-73 04/88 VM DENT 10 '35.'141 -04/88 VM DENT .6 35-163 04/88 VM DENT 7 36-136 04/88 VM DENT 5 37-83 04/88 VM DENT 6-37-: 101- 04/88-VM + 30.00" DENT 21, 37-139 04/88 VM DENT '38 04/88 DC + 32.40" DENT 9 04/88 VM DENT 8 37-145 04/88 VM + 3.90" DENT. 7 37-151 04/88-- VM DENT 11-37-157 04/88 VM- + 5.00" DENT 9 38-122 04/88 C4 -+ 2.70" . DENT 19 38-130 04/88. H2 + 33.70" DENT 11 38-142 04/88 C4 + 2.90" DENT 7 38 '-156. 04/88 H2 + 31.80" DENT 21 39-101 04/88~ C7 DENT-5 40-10 04/88 Ho + 22.80" DENT 8 36.c0" DENT 18 40-36-04/88 CO + 40-' 40 04/88 H2 + 33.60" DENT 66 40-58- 04/88 H2 + 36.20" DENT 8 36.70" DENT 45 04/88-H2 + 40-60 04/88 H1 + 24.20" DENT 6 40-84 04/88-VM DENT 8 17.21" DENT 7 41.- 5 04/88 HTS-SF + 41-13 04/88 VM DENT 10 \\ 41-37 04/88 VM DENT 7 ~ 41-45 04/88 VM DENT 6-41-47 04/88-VM DENT 10 41-59 04/88 VM DENT 7 41-61 -04/88-VM DENT 9 41-77 04/88 HI + 28.70" DENT 9 41-135 04/88 VM DENT 6 42-30 04/88 CTS-SF + 32.20" DENT 8 42- '102 -04/88 HTS-SP DENT 41 42-154 04/88 C7 DENT 20. 04/88 C7 + 1.80" DENT 19 t I 43-103 04/88 HTS-SF DENT 52 44-86 04/88 C7 DENT 5 45-103 04/88 HTS-SF DENT 37 46-102 04/88 HTS-SF DENT 30 46-122 04/88 VM DENT 5 04/88 VM DENT 7 46-138 04/88 HS + 37.50" DENT 6 04/88 H6 DENT 8 04/88 H5 + 30.80" DENT 5 04/88 C6 + 5.00" DENT 8 04/88 C6 + 3.20" DENT 7 04/88 C6 + 1.40" DENT 9 04/88 C5 + 37.70" DENT 5 47-11 04/88 C5 + 15.00" DENT 8 47-

33. 04/88 C3 DENT 9

47-61 04/88 HTS-SF + 19.10" DENT 9 49-15 04/88 HTS-SF + 17.80" DENT 33 49-29 04/88 C1 + 24.50" DENT 59 18.20" DENT 7 49-31 04/88 HTS-SP + 52-36 04/88 H7 DENT 6 52-58 04/88 H7 DENT 10 5.90" DENT 13 52-74 04/88 C4 + f t l

Outage: 04/88 - Generator: -11 Plcnt: CALVERT CLIFFS UNIT 1-Steam OUERY: DENTS,ALL MILS,ALL ELEY (ALL. TUBES),ALL-RL (j. ROW-LINE OUTAGE ELEVATION -INDICATION VOLTS 23.10" DENT 11 54-34 04/88 C5 + 55-159 04/88 VM DENT 8-57-25 04/88 DH + 21.60" DENT 15 57-65 04/88 C2 + 37.20" DENT 48 57-157 04/88 H7 + 2.70" DENT 15 58-74 04/88 C6 + 22.30" DENT 13 04/88 H7 DENT 5 59-23 04/88 DH + 23.60" DENT 6 59-41 04/88 CTS-SF + 23.00" DENT 7 60-92 04/88 CTS-SF + 7.20" DENT 8 64-142 04/88 DH + 27.20" DENT 8 66-68 04/88 H4 + 12.20" DENT 6 66-110 04/88 VM DENT 5 67-143 04/88 C7 + 2.20" DENT 5 04/88 H7 + 8.20" DENT 6 69-13 04/88 VM + 23.40" DENT 6 69-19 04/88 DH + 10.10" DENT 6 69-23 04/88 VM + 23.60" DENT 6 69-25 04/88 VM + 23.80" DENT 6 69-27 04/88 VM + 23.70" DENT 6 8.40" DENT 6 69-29 04/88 VM + 69-33 04/88 VM + 24.50" DENT 5 69-35 04/88 VM + 24.50" DENT 5 69-37 04/88 VM + 24.10" DENT 5 69-43 04/88 H8 + 7.70" DENT 5 04/88 DC DENT 5 69-101 04/88 VM + 23.10" DENT 6-70- 102 04/88 HTS-ST + 24.30" DENT 9 20.00" DENT 22 72-26 04/88 C5 + 20.00" DENT 21 04/88 C5 + 72-30 04/88 C7 + 23.46" DENT 8 21.00" DENT 8 e 72-72 04/88 VM + , '~s) 80- 134 04/88 DH DENT 10 \\_/ 82-58 04/88 H3 + 4.60" DENT 12 82-126 04/88 C7 + 15.50" DENT 7 04/88 C7 + 16.00" DENT 7 04/88 VM DENT 9 14.70" DENT IS 04/88 H7 + 04/88 HB + 1.10" DENT 9 04/88 H8 + 9.60" DENT 21 04/88 DH DENT 13 6.20" DENT 21 04/88 DH + 83-113 04/88 H3 + 31.50" DENT 5 84-126 04/88 VM DENT 7 85-147 04/88 HI + 22.80" DENT 7 88-30 04/8L H3 DENT 5 I 88-40 04/88 VC

  • 10.90" DENT 9

90- 142 04/88 VM DENT 9 91-23 04/88 C9 + 1.90" DENT 13 91-37 04/88 H9 DENT 40 91-39 04/88 H9 DENT 52 91-41 04/88 H9 DENT 83 91-43 04/88 H9 DENT 43 04/88 C9 + 2.10" DENT 9 91-45 04/88 H9 DENT 56 } 91-47 04/88 H9 DENT 67 91-49 04/88 C9 + 1.80" DENT 8 ) 91-51 04/88 H9 DENT 31 91-53 04/88 H9 DENT 68 91-55 04/88 H9 DENT 46 91-57 04/88 H9 DENT 34 91-59 04/88 H9 DENT 38 91-61 04/88 H9 DENT 81 91-63 04/88 H9 DENT 51 l 91-65 04/88 H9 DENT 20 f l

y. ~ OPlants CALVERT CLIFFS ONIT.1: Stean Generator: 11' a 1 ny Outage: 04/88 q n i IOUERY:: DENTS,ALL MILS,ALL ELEV TALL TUBES),ALL-EL- .w mi i ~ ROW-LINE OUTAGE ELEVATION- ' INDICATION' VOLTS l AM - 2.~ 1 0 " ' DENT 7 E' 91 .67 04/88- .H9 + 91-69- 04/88 H9 DENT-35: 1 91. 71-04/88' H9 DENT -9 i 91-L73 04/88; H9 DENT 29. 91-175' 04/88. H9 -DENT' 52 91. 77-.04/88' H9 -DENT-24 . 91 - 79 04/88. H 9. DENT-35 91-81 04/88 H9-DENT 25 91-83 '04/88-H9 DENT 30 91 04/88-C8 + 4.80" DENT' 7-04/88 C9 DENT 8 91-87 04/88' H9' DENT-59 91-' 89' 04/88 C9 + 1.70" . DENT. 42 13 04/88 'H9 DENT 91-91 04/88 C9. + 1'.60" DENT . 6 04/88-H9 DENT .38 91-93 04/88 H9 DENT 27 91-95 04/88 H9 DENT 25 91-- 97 04/88. H9 , DENT 30-91-99-04/88 .H9 DENT 40 91-' 101 04/88: H9 DENT 18-91-103 04/88 H9 DENT 41-91-105 04/88 H9 DENT -56 04/88 C9 DENT 6 91-1107 04/88 H9 DENT 67 91-109 04/88-H9 DENT 25 91-111 04/F8 H9-DENT 43 91: 113' 04/88. H9 DENT -36 91-117 04/88 .H9 DENT 6 91-119 04/88 VM DENT ' 14 - 2.00" DENT .16 04/88' C8 + 91--.121 04/88 H9 DENT-28 Q 04/88 C9 DENT 22 04/88 C9 DENT' 33-04/88 C8 + 17.30" DENT 16- .04/88 C8 + 17.90" DENT 5 18.30" DENT-7 04/88 C8 + 91-~123 04/88 H9 DENT ' 42-04/88 H9 4 2.10" DENT 7' 91-125 04/88 H9 DENT 42 91-127 04/88 H9 DENT. 51 04/88 H9 + 2.30" DENT 16 91-129 04/88 H9 DENT '5 92-38 04/88 H9 DENT 10 42 04/88 H9 DENT 38 92-44 04/88 H9 DENT 80 92-46 04/88 H9 ' DENT 103 ~' 92-50 04/88 H9 DENT 20-92-52 04/88 H9 DENT 79 92-54 04/88 H9 DENT 59 92-56 '04/88 H9 DENT 30' 92-58 04/88 H9 DENT 28 92-60 04/88 H9 DENT 70 .92-62 04/88 H9 DENT 40 92-64 04/88 H9 DENT 34 92-66 04/88 H9 DENT 30 92-68 04/88 H9 DENT 31 92-- 70 04/08 H9 DENT 27-92-72 04/88 H9 DENT 37 92-74 04/88 H9 DENT 45 92-76 04/88 M9 DENT 11 92-78 04/88 H9 DENT 37 92-80 04/88 H9 DENT 42 92-82 04/88 H9 DENT 21 - f, '92-86 04/88 H9 DENT 50

...... esas we.... ns.'.s............ m.., sc. i.se o............ e.ecec. . uce, cc....... Page Plant: CALVERT CLIFFS UNIT 1 Steam Genera cr: 11 Outage: 04/88 OUERY: DENTS,ALL HILS,ALL ELEV (ALL TUEES),ALL-RL O. ROW-LINE OUTAGE ELEVATION INDICATION VULTS 92-88 04/88 M9 DENT 34 92-90 04/88 H9 DENT Sc 92-92 04/88 H9 DENT 98 92-96 04/88 H9 DENT 22 92-98 04/88 H9 DENT 30 92-100 04/88 H9 DENT 16 92-102 04/88 H9 DENT 32 92-104 04/88 H9 DENT 47 92 .106 04/88 H9 DENT 41 92-108 04/88 H9 DENT 48 92-110 04/88 H9 DENT 18 92-112 04/88 H9 DENT 21 92-114 04/88 H9 DENT 37 92-122 04/88 H9 DENT 70 92-124 04/88 H9 DENT 93 92-126 04/88 H9 DENT 39 92-128 04/88 H9 DENT 42 93-37 04/88 H9 DENT 16 93-39 04/88 H9 DENT 45 93-41 04/88 H9 DENT 15 t 93-43 04/88 H9 DENT 43 93-45 04/88 H9 DENT 114 93-47 04/88 H9 DENT 72 93-49 04/88 H9 DENT 19 93-51 04/88 H9 DENT 57 93-53 04/88 H9 DENT 75 93-55 04/88 H9 DENT 41 93-57 04/88 H9 DENT 103 93-59 04/88 H9 DENT 104 93-61 04/88 H9 DENT 60 93-63 04/88 H9 DENT 70 O 93-65 04/88 H9 DENT 31 93-67 04/88 H9 DENT 42 93-69 04/88 H9 DENT 36 93-71 04/88 H9 DENT 33 93-73 04/88 H9 DENT 62 93-75 04/88 H9 DENT 7 93-77 04/88 H9 DENT 30 93-79 04/88 H9 DENT 48 93-85 04/88 H9 DENT 51 93-87 04/88 H9 DENT 106 93-89 04/88 H9 DENT 82 93-91 04/68 H9 DENT 48 93-93 04/88 H9 DENT 39 93-95 04/88 H9 DENT 91 93-97 04/88 H9 DENT 81 93-99 04/88 H9 DENT 54 93-101 04/88 H9 DENT 65 93-103 04/88 H9 DENT 63 93-105 04/88 H9 DENT 64 93-107 04/88 H9 DENT 89 93-109 04/88 H9 DENT 40 93-111 04/88 H9 DENT 43 93-113 04/88 H9 DENT 72 93-115 04/88 H9 DENT 26 93-121 04/88 H9 DENT 60 .93-123 04/88 H9 DENT 46 93-125 04/88 H9 DENT 55 93-127 04/88 H9 DENT 62 93-131 04/88 H9 DENT 16 93-141 04/88 HTS-SF + 28.30" DENT 7 94-38 04/88 H9 DENT 41 94-40 04/88 H9 DENT 58 94-42 04/88 H9 DENT 11 94-44 04/88 H9 DENT 101 0 1

Plants.:CALVERT' CLIFFS UNIT:1 1 steam Generator: -. Outage: 04/88 .p OUERY: DENTS,'ALL MILS,AL'L.ELEV-(ALL TUBES),ALL-RL I - ROW-LINE ~ OUTAGE' ELEVATION INDICATION VOLTS-7.50" DENT 13

04/88-H3

-+ .94. 46 04/88. H9 DENT 18 94 - 50 04/88 .H9 DENT - 3 4' 94-52 04/88 H9 DENT 51. 94-54 04/88 H9 DENT-61

94-56- 04/88 H9 DENT 107 94-58.04/88

-H9' DENT' 113 '94-60 04/88 H9 DENT 64 .94-62 04/88 H9. DENT 25 94-64 04/88L H9-DENT 61-94-66 04/88 .H9-DENT 6 94 : 68 04/88. H9 DENT 23 94 04/88 H9 DENT 28 94-74 04/88 H9 DENT 19 94-76 04/88 H9 -DENT 57.78 04/88 H9 DENT 34-94-80 04/88 H9 DENT 51 94-82 04/88 H9 DENT '71' 94-84 04/88 H9 DENT - 24 94-86. 04/88 H9 DENT 113 94-88 04/88 H9 DENT 116 94- '90 04/88- ~H9 DENT 27 .94-92 04/88 H9 DENT 49 94-94 04/88 H9 DENT 13 94-96 04/88 H9 DENT 47 94- '98 04/88 H9 DENT 34 94-100 04/88 H9 DENT-13 94-102 04/88 H9 DENT 58-94-104 04/88 H9 DENT 96 94-106 04/88 H9 DENT 88 I 94- '108 04/88 H9 DENT 38- '? N 94-'110 04/88 H9 DENT 26 94-'112 04/88 H9 DENT 36 ) 94-114 04/88-H9 DENT 75 94--116 04/88 H9 DENT 7 94 122 04/88 H9 . DENT 64 94 -124 04/88 H9 DENT 91 94-126 04/88 H9 DENT 61 95-39 04/88 H9 DENT 47 95-41 -04/88 H9 DENT 55 95-43 04/88 H9 DENT 52 95-45 04/88 H9 DENT. 35 95-47 04/88 H9 DENT 58 49 04/88 H9 DENT 26 95-51 04/88 H9 DENT 33-95-53 04/88 H9 DENT 67 95-55 -04/88 H9 DENT-9 95-57 04/88 H9 DENT 86 95-- 59 04/88 H9 DENT 63 95-61 04/88 H9 DENT 16 95-63 04/88 H9 DENT 58 95-67 04/88 H9 DENT 39 95-69 04/88 H9 DENT 53 95-71 04/88 H9 DENT 37 95-73 04/88 H9 DENT 26 04/88 C9 DENT 6 95-75 04/88 H9 DENT 40 95-77 04/88 H9 . DENT 52 95-79 04/88 H9 DENT 62 95-81 04/88 H9 DENT 101 95-83 04/88-H9 DENT 60 95-85 04/88 H9 DENT 50 95-87 04/88 H9 DENT 117 95-89 04/88 H9 DENT 78 / 95-91 04/88 H9 DENT 20 0

vue m t., m..............,., in i.. on ::.........noc.6 .iuce, ce....... Pag

  • Plant: CALVERT CLIEFS UNIT 1 Steam Generator: 11 Outage:

04/88 OUERY: DENTS,ALL MILS,ALL ELEV (ALL TUBES),ALL-RL ROW-LINE OUTAGE ELEVATION INDICATION

VOLTS, 95-93 04/88 H9 DENT 51 95-95 04/88 H9 DENT 36 95-97 04/88 H9 DENT 77 95-99 04/88 H9 DENT 22 95-101 04/88 H9 DENT 62 95-103 04/88 H9 DENT 25 95-105 04/88 H9 DENT 43 95 107 04/88

'19 DENT 55 95-109 04/88 H9 DENT 30 95-111 04/88 H9 DENT 28 95-113 04/88 H9 DENT 26 95-115 04/88 H9 DENT 12 95-123 04/88 H9 DENT 12 95-127 04/88 H9 DENT 23 96-24 04/88 C3 DENT 8 96-42 04/88 H9 DENT 54 96-44 04/88 H9 DENT 33 96-46 04/88 H9 DENT 50 96-54 04/88 H9 DENT 73 96-56 04/88 H9 DENT 49 96-58 04/88 H9 DENT 47 96-60 04/88 H9 DENT 54 96-62 04/88 H9 DENT 21 96-70 04/88 H9 DENT 10 96-72 04/88 H9 DENT 8 96-76 04/86 H9 DENT 26 96-78 04/88 H9 DENT 11 96-80 04/88 H9 DENT 54 96-82 04/88 H9 DENT 136 96-84 04/88 H9 + 9.90" DENT 74 17.20" DENT 9 04/88 VM + 86 04/88 H9 DENT 73 60 96-96-88 04/88 H9 DENT 113 96-90 04/88 H9 DENT 57 96-92 04/88 H9 DENT 55 96-94 04/88 H9 DENT 53 96-96 04/88 H9 DENT 79 96-98 04/88 H9 DENT 98 96-100 04/88 H9 DENT 52 96-102 '04/88 H9 DENT 43 96-104 04/88 H9 DENT 77 96-106 04/88 H9 DENT 38 96-108 04/88 H9 DENT 97 96-110 04/88 H9 DENT 13 96-112 04/88 H9 DENT 21 96-114 04/88 H9 DENT 68 96-116 04/88 H9 DENT 25 96-122 04/88 H9 DENT 11 7 96-124 04/88 VH + 14.80" DENT 96-126 04/88 H9 DENT 70 90- 138 04/88 H9 DENT 5 97-33 04/88 H7 + 2.90" DENT 6 04/88 H7 + 3.90" DENT 11 97-37 04/88 H9 DENT 22 97-41 04/88 H9 DENT 36 97-43 04/88 H9 DENT 136 97-45 04/88 H9 DENT 23 l 97-47 04/88 H9 DENT 13 l 97-55 04/88 H9 DENT 75 l 97-57 04/88 H9 DENT 99 97-59 04/88 H9 DENT 39 97-61 04/88 H9 DENT 70 97-65 04/88 H9 DENT 28 97-67 04/88 H9 DENT 12 97-69 04/88 H9 DENT 21 O

.n-Plant:ECALVERT' CLIFFS-UNIT 1. Stear.; Generator: 1 1.- Outage: 04/88-lu, [ "[..Y' QUERY: DENTS,ALL' MILS,ALL:ELEV t ALL '.TURES 1, ALL-RL' {H ;ld R9W-LINE OUTAGE' 'ELEVATTON' INDICATION VULTS' 91-71 04/88 .H9 DENT 18-97-73' 04/88 H9 -DENT 6S 97- -77 ~04/88 H9 DENT-79-m7 9 04/88 H9 DENT- -81 4 97-81 04/88 -H9 DENT-82-97-83 04/88 H9 DENT-146 97-35 04/88 H9 DENT 70 97-87.04/88. H9. DENT 100 97 - 89 04/88-H9. DENT 79 97-91 04/88 H9 DENT 35-97-93.04/88 H9 DENT l30 97-95 04/88 H9 DENT 89-97-

97. 04/88 H9 DENT-117 97-'

99 04/88 H9 DENT 63 97-101 04/88 H9 DENT 44' 97-103 04/88 H9-DENT 53-DENT' 96 97-105 04/88' H9 . 15.50" DENT 7-97-107' 04/88 C8 + 04/88 H9 DENT. -47 -97 109' 04/88 H9 DENT 77 '97-.113. 04/88 H9 DENT 83 97-115 04/88 H9 DENT-31 97-'117 04/88 H9 DENT 10 97-119 04/88 H9 DENT 31 97-121 04/88 H9 DENT 9 97-123 04/88 H9 DENT 24 04/88 H9 + 1.60" DENT 16 97-127 04/88 H9 DENT 46' L 04/88 H8 DENT 5 97-137. 04/88 H8 + 4.00" DENT 6' 04/88 H8 7.70" DENT 7 04/88 H8 + 10.30" DENT 7 04/88 H8 + 13.20" DENT 5 18.40" DENT 5-04/88 H6 + 04/88 H8 + 19.96" DENT 6 04/88 H6 + 20.40" DENT 6' 04/88 H9 DENT 9. 04/88 H9 DENT IS 04/88 CS + 11.20" DENT 6 04/88 C8- + 17.80" DENT 6- ~98-38' 04/88 H9 DENT '37 98-42 '04/88 H9 DENT 95' 98- '44 04/88 H9 DENT 65 98-46 04/88' H9 DENT 64. 98-50 04/88 H9 DENT 35 98-54 04/88 H9 DENT 40 98-58 04/88 H9 DENT 46 98-

60. 04/88 H9 DENT 43 36 98-62' 04/88 H9 DENT 98-64 04/88 H9 DENT 12

'98-66 04/88 H9 DENT 17-98-70 04/88 H9 DENT 54 98-72 04/88 H9 DENT 76 I 98-82 04/88 H9 DENT 84 98-84 04/88 H9 DENT 95 -98 ' 86 04/88 H9-DENT 60 98-88 04/88 H9. DENT 48 98-90 04/88 H9 DENT 'll 98-92 04/88 H9 DENT 28 98 - 98~ 04/88 H9 DENT 66 98-102 04/88 H9 DENT 79 98-104 04/88 H9 DFNT $6 98-106 04/88 H9 DENT 21 4 q 98-108 04/88 H9 DENT 54 [ 98-'110 04/88 H9 DENT 15 TO, v )

L P l an t': LCALVERT~CLTFFS UNIT:1 S t e a rn Generator:111-f Outager; '04/88L'~ +

OUERY
DENTS,ALL' MILS,ALL ELEV (ALL TUEES);ALL-RL-1,, )

ROW-LINE OUTAdE ELEVATION INDICATION- -VOLTS-9 8-/ 1 ~12 ' 04/88-H9-DENT 14 - n 98 .114-04/88 H9 DENT 42-98 116 04/88' H9 DENT '15 ' 98-120.- 04/88 H9 . DENT. 122 -98 '124 04/88 H9-DENT: 29- .98 126 04/88 H9' DENT '20 199-41 04/88 -H9 DENT 21

99-43 04/88 H9 DENT-49-99-45 04/88.

H9 ' DENT 29 .99 '47' 04/88^ .. H 9 - ' DENT. 38; 99-53. 04/88 H9 DENT 13' 99- 55,.04/88-H9 DENT

39

~99-57 04/881 H9-DENT '24 99-61 04/88~ H9 DENT-45 99- '65' 04/88-H9 DENT 58 99 ' 67 04/88-H 9. DENT 22-99-69 04/88-H9 DENT 41 99-71: v4/88-H9 . DENT 130 99-73 04/88 H9' . DENT 42-34 99-75 04/88 H9 DENT 99-77 '04/88. H9 DENT 2S- '99-79 04/88 H9 DENT 20 '99-81 04/88 H9 DENT 67 99-83 04/88-H9 DENT 83 99-85' 04/88. H9 DENT 76 99-87 04/88 H9 DENT 108 99 - 91-04/88-H9 DENT 40-99-93 04/882 H9-DENT 14 99-95 04/88 H9

DENT

'55-99- .97 >04/88 H9 DENT 61 '99-99 04/88 H9. DENT 89 '99-101 04/88 H9. DENT-100-99-103 04/88 H9 DENT ~ 11 l(' ' '99-;105-.04/88 H9 DENT. '20 99 .107-04/88 H9 DENT' -30 99.109' 04/88 H9-DENT . 27. c 119 04/88 H9

DENT-

. 115: 99-113 04/88 H9 DENTJ 14 99-125 04/88 H9 DENT 20 100-40 04/88 'H9 DENT-17

100-

.42 :04/88 H9 DENT 68-100-~ 44 '04/88 H9 DENT 38-100-46: 04/88 H9 DENT 38 .100-48 04/88 H9 + 0.20" DENT 88 100-' 50 -04/88 H9 DENT '30 -100-52' 04/88 H9 DENT '80 100-54 04/88 H9 DENT- ~54-100-56 04/88 H9 DENT 52 20 100-58 04/88 H9 DENT 4 100-62.04/88 H9 DENT 73 100-64 04/88 H9 DENT 95 100-66 04/88 H9 DENT 49 100-68 04/88 H7 + 17.50" DENT 6 1 04/88 H9 DENT 30 1 100-70 04/88 H9 DENT 46 04/88 DH + 13.40" DENT 6- -100-72 04/88 H9 DENT 50 '100-78 04/88 HS + 15.50" DENT 6 04/88 H5 + 16.00" DENT 9 04/88 H9 DENT 29 100-82 -04/88 H9 DENT 124 -100-84- 04/88 H9 DENT 71 100-86 04/88 -H9 DENT 34 100-88 04/88 H9 DENT 39 100-90 04/88 H9 DENT 26 b

u L

L l lu

Plant:.CALVERT' CLIFFS UNIT.1 S t e e.m. G e r.e r a t o r : 11 Outage: '04/88 L L DENTS,ALL MILS,ALL ELEV FALL TUBES),ALL-RL QUERY: eb~ ROW-LINE ' OUTAGE ELEVATION' INDICATION VOLTS bi: 100-92 04/88 H9 DENT 38 100-96-04/88 H9-DENT ~ 5 l100 .-98 04/88-H9 , DENT 11 100 100 04/88-H9 DENT 67-100- 102 04/88 H9 DENT 65~ ~100- 108 04/88-H 9. DENT 29 100- 114- 04/88-H9 DENT- '29 101-.41 04/88 H9 DENT 67 101-45 04/88 H9 DENT 27-101-149 '04/88

H9

' DENT 10 101-51 04/88 H9 LENT 43 101-53' -.04/88. H9 DENT 34' ~101-55' 04/88_ H9 DENT 100 101-57 04/88 H9 ' DENT-31~ 101-61 04/88 H9 DENT 31 101-63 04/88 H9 DENT 63 - 101 -~ 65. 04/88' H9 DENT 50l 101-71 04/88-H9 DENT ~ 5 8' 101-79 04/88-H9 DENT 20 101-81 '04/88 H9 DENT-21 101-83 04/88 H9 DENT 43 101-85 04/88 'H9 DENT 15 101-89 04/88 H9 DENT' 16 '101-95 04/88 H9 DENT 29 101-99 04/88- .H9 DENT 30 101 :101 04/88' H9 DENT 75 101-103- 04/88 H9 DENT -90 101--105 04/88 H9 DENT 11 101-107.04/88 H9 DENT 33 101-109- 04/88 H9 DENT 23 101-113 04/88 H9 DENT. 59 fm / 1 101 115 104/88 H9 DENT 12 i '/ 101-123.04/88 H9 DENT 6-102 40 -04/88 H9 DENT 40 102- -42 04/88 H9 DENT 71-102-44 04/88 H9 DENT 64 102-46 04/88 H9 DENT -29 102-48 04/88 H9 DENT 19 102-50 04/88 H9 DENT 31 66 102-52 04/88 H9 DENT . 110~ 102-- 54 ~04/88 H9 DENT 102-56 04/88 H9 DENT .I6 102-58 04/88 H9 DENT 7 102-62.,04/88 H9 DENT 25 102-64 04/88 H9 DENT 43 102-66 04/88 H9 DENT 7 102-70-04/88 H9 DENT 50 102-72 04/88 H9 DENT 34 102-74 04/88 H9 DENT 13 102-78 04/88 H9 DENT 21 102-80 04/88 H9 DENT 7 102-82' 04/88 H9 DENT 20 102-84 04/88 H9 DENT 18 102-86 04/88 H9 DENT 22 102-90' 04/88 M9 DENT 16 i 102-94 04/88 -H9 DENT 13 -l .102-98 04/88 H9 DENT 24 102-100 04/88 H9 DENT 70 102-102 04/88 H9 DENT 100- .102-104 04/88 H9 DENT 5 102-108 04/88 H9 DENT 35 102-112 04/88 H9 DENT 19 102-114 04/88 H9 DENT 32 s 102 .118 04/88 H9 DENT 6 102-.120 04/88 H9 DENT 14 i

R.a......e ......L,1...?....u.a.:...,;..... ,............... 6,;,,..,..... w e ia L /P1 h nt!EC A LVERT JCLIFFS UNIT:* l- ' Steam'Generuteri 11 ~ ~~ Outage.: 04/88 1 ~ tOUERY: DENTS,ALL MILE,ALL ELEV-f.ALL' TUBES),ALL-RL- - : ROW-1;INE OUTAGE ELEVATION INDICAT!on ' VOLTS R~ ~ /

102-?l22' 04/86-R4 DENT

-6 103-~'41 04/88 H9 -DENT: Se 60 103-~ -43 04/88c H9 DENT .14 L 103-- 45 ~04/88 'H9 DENT .-103-49' 04/88 H 9. -DENT' 16

103-l51T 04/88' H9 DENT 27 103-53 04/88 H9.

DENT: 81- '103-55 04/88 -H9 ' DENT 75.

103-

'57-04/88 .H9. DENT 12. -103-61.04/88' H9. DENT 5 103-63 04/88 .H9 -DENT' 23 '103-65 04/88 H9 DENT. 50i 103-67- 04/88 H9 DENT-l'2

103. 851 04/88

'H9 DENT.- 26'

10 3 =

87' 04/88 H 9. DENT' 52: 103-- 89 04/88 H9 DENT. 6 '. -103-91' 04/88 H9-DENT ~ 10 103- (93 04/88-H9 DENT 7 .103 1-95 04/88-H9 DENT- ' 56L 1103.101 04/88 H9 DENT-75' '103-103 04/88 H9 DENT-30

.103-107- 04/88 H9 DENT 63 103--109 04/88 H9 DENT 57 103-111 04/88 C9 DENT" 8'

04/85. H9 , DENT 8 '- 17.60": -DENT 6 04/88 H8 + 103 ='113 04/88 H9. DENT 32-

104--

4 2 -. 04/88-H9 DENT e

104-44 04/88

'H4 DENT 51 '104 ~ 50 04/88 H9 DENT 10 /*y

104-.52 04/88 H9 DENT 29 s

104 - '54 04/88 H9 DENT. '36' i' AZ: '104-56 04/88 H9 DENT 63 104-1 ~72 04/88 H9 DENT 27' 104-82 04/88 H9 DENT- .12 104-84 04/88 -H9 ' DENT -6 104 86 04/88 ~ H 9'

DENT 39

-104-88 04/88 H9 ' DENT 6 ~104-94' 04/88 H9 DENT 40 104-100.04/88" H9 DENT 16 104 L108 04/88 H9 DENT 12 104-114-04/88 H9 DENT 10 '105. 43 04/88 H9 DENT. 66 105-45 04/88 H9 DENT-7 10b-47 04/88'. H9 DENT 18 '105-49 04/88 H9 DENT 8 105-51 04/88-H9 DENT 9 .105-53 04/88-H9 DENT 84 33 105-- 55 04/88-H9 DENT 105-- 57 04/88 H9 DENT 30-105-59. 04/88 H9 DENT 13 -105 '61 04/88 H9 DENT 28 105-63 04/88 H9 DENT 77 105-65 04/88 H9 DENT 58 .105 - 67 04/88. H9 DENT 21 105 : -83 04/88 H9 DENT 39 105-' -85 04/88-H9 DENT 21 105- '87 04/88 H9 DENT 98' 105-89 04/8'8 H9 DENT 9 105-99 04/88 H9 DENT 25 .105-101 04/88 H9 DENT 29 '105-L103 04/88 H9 DENT 48 105-113 04/88 H9 DENT 39 105-121 04/88 H9 DENT 9 106' 42 04/88 H9 DENT 28 + f.

my g . a e e, c a...... P a g e -

1; e.u... 'on s r itun 6 ni:.vu, s....... niu,..,

no. i,n io.c 6..... neeeer. Plent:.CALVERT' CLIFFS UNIT +1. Steam ~Generatort 11- . Outage.: ' 04/88-1 py . QUERYi~ DENTS,ALL MILS,ALL ELEV-(ALL TUEEE1,ALL-RL p-

3. _

ROW-LINE-LOUTAGE ELEVATIOM INDICATION R)LE. 106-: 44.104/88 H9 DENT .1 2. 106-52' 04/88 H9-DENT .15 - 106-56 04/88-H9 DENT 30 '106- '.58 '04/88 H9 DENT-12 1 >106-64-04/88 H9 DENT 48 106-86~.04/88 H9 . DENT 50 106- '92-04/88' H9 DENT 48 106 - 94 04/88 H9 -DENT 55' 106-'102 04/88 H9 DENT' 42' 106-104 04/88 H9 DENT 54 106-108. 04/88 H9. DENT 22 '106-110 04/88 H9-DENT 13 106-114 04/88 H9 DENT-20-106 _120.. 04/88. H9 DENT 33 107 - 531 04/88 H9 DENT 51 .107 57 04/88 H9 DENT 29 107-61.04/88 H9 DENT 34 107-63 04/88 H9 DENT 74 107-86.04/88. H9 DENT 24 '107-- 93 04/88 H9 DENT 29 107-95 04/88 H9-DENT 29 .] 107 - 97 04/88 H9 DENT 6 107 ' 99 04/88 H9-DENT 25 107.101 04/88 H9-DENT 49 107-103 04/88-H9 DENT 31 107-.107 04/88 H9 DENT 10 107e o117. 04/88' H9 DENT 17 107-'121 04/88 H9 DENT 45 107-129 04/88 H9 + 1.70" DENT 10 108-82 '04/88-H9 DENT 61 108-' 84 04/88 H9-DENT 39 A)-; 108-86 04/88-H9 DENT 41 .g -A / 108-94 04/88. H9 DENT 35' 108-96 04/88 H9: DENT 43 108-100 04/88 H9 DENT 32 -108-108.04/88 H9 DENT 15 109-E 45 04/83 H9 DENT' 9 13.40" DENT 20 04/88 .C4 + 109-49 04/88 H9 DENT 5 109-5 3.- 04/88 H9 DENT 27 109. 61 :04/88 H9 DENT '18 109-63 704/88 H4 + 13.60" DENT-15 109-85.04/88 H9. DENT 38 109-87' 04/88 H9 DENT 20 109-89 04/88 H9 DENT 11 109-91 04/88 H9 DENT 19 109-93 04/88 H9 DENT 30 '109-

95 04/88 H9 DENT 13 109-97 04/88 H9 DENT 56 109-121 04/88 H9 DENT 27 04/88 H8

+ 18.30" DENT 7 110-44 04/88 H9 DENT 12 110-46 04/88 H9 DENT 5 110-48 04/88 H9 DENT 13 110-54 04/88 H9 DENT 12 110-56 04/88 H9 DENT 12 110-62-04/88 H9 DENT 20 '110-66-04/88 H7 + 22.50" DENT 5-110-72 04/88 H9 DENT 9 110-76 04/88 H9 DENT 15 110-82 04/88 H9 DENT 9 110-' 84 04/88 H9 DENT 35 110-86' 04/88 H9 DENT 31 110- '90 04/88 H9 DENT 17 110-92 04/88 H9 DENT 22 ,.s

m,w y ( iPlante CALVERT-CLIFFS UNIT 1 S te a m. Ge ne r a to r s.11'- JOutage: 04/08-1 OUERY: DENTS, ALL MILS, ALL ELEV a ALL TUBES ), ALL-RL. e,k. .. ROW-LINE OUTAGE ELEVATION INDICATION ' VOLTS-L: DENT 18 110- '9 4 ' 04/88 H9 ' + 04/88-

_C1,

. 33.90" DENT-11 110-' 9604/88 H9 DENT-21-110-1 98 .04/88-H9 DENT 19. 110- 128 04/88 VC DENT 5 111-49 04/88 H9 DENT 8' '04/88-H9 DENT 21 111- ;53: 111-55. 04/88 H9 -DENT 24 111- '57-04/88 H9 DENT 15 r 111-75 04/88 VML + 28.50" DENT 7-111-c 105 04/88 VC + 1.50" ' DENT 11'

112-44 04/88

'H9 DENT 16 112-5604/88 H9 DENT 9 113-55 04/88 H9 DENT 8 113-61 04/88 H9 DENT 23 -113-89 04/88 H9 DENT 10 114-46- 04/88. H9 DENT 25 114-48E 04/88 H9 DENT '30 P-114-74 04/88' H7. +' 8.50" DENT 6 114- -86' 04/88 H9 DENT 41 114-- 88 04/88-H9 DENT-50 114. 90 04/88 H9' DENT 15 '115-47 04/88 .H 9 DENT 12 115-- 49 04/88 H9 DENT 21 115-61 04/88 H9 DENT 16 115-85-04/88 H9 DENT 8 16.00" DENT 6 116-38' 04/88 C9 + 116- ~ 86 04/88 H9 DENT 14 20.40" DENT 9 116-:'100 04/88 C9 + 117-39 04/88 H9 .+ 17.40" DENT 14 .X 04/88 H10 ~ DENT 9 i: 04/88 H9 + 20.40" DENT 10 7.50" DENT 6 7f ) '04/88 C9 + -(, 04/88 C9 + 8.30" DENT 20-8.70" DENT 21 04/88 C9 + 04/88 C0 + 9.40" DENT ~ 19 04/88 C9 +-10.60" DENT 11 04/88-' C9 + 13.60" DENT 23 04/88 C9 + 14.50" ' DENT 19 04/88 C9 + 16.80" DENT 24 17.60" DENT 36 04/88 C9 + 117-41 04/88' H9 + 6.90" DENT 6 117-

51' 04/88 DH

+ 9'.70" DENT 13 117-~ 95 04/88 H10 DENT 68 117-99 04/88 H10 DENT 22 117-101- 04/88 C5 + 15.60" DENT 7 04/88 C10 DENT 7 117-105 04/88 H10 DENT 18 117-113 04/88 H10 DENT 39 118-88.-04/88 H10 DENT 9 118-94 04/88 H10 DENT 61 118 - 96 04/88 H10 DENT 16 1 118-100 04/88 H10 DENT 17 119-43 04/88 H9 + 19.80" DENT 9 04/88 H9 + 20.70" DENT 7 119-89 04/88 H9 DENT 20 119-95- 04/88 H10 DENT 8 119-99- 04/88 H10 DENT 5 119-105 04/88 H10 DENT 17 120-70 04/88 VH + 3.40" DENT 27 i 04/88 C8 + 9.30" DENT 12 i 04/88 C6 + 18.60" DENT 14 120-72-04/88 VC + 4.80" DENT 11 120--106 04/88 H10 DENT 17 I 04/88 C9 + 13.30" DENT 6 i i \\

. -, m, _ rw .w -Plant: CALVERTc CLIFFS.' UNIT t 1" Steam' Generator: 11

Ou tage t.

z.04/88: r 0 .l OUERY ': ' DENT S, ALL ' MILS, A LL' ' ELEV (ALL$' TUBES),ALL-EL [ ROW-LINE OUTAGE ELEVATION I N DI C ATI ON VOLTS -i L? H10' i -121- '101 04/88 DENT 27 04/88, H6 + 13.70" -DENT 7

121-105 04/88.

H10 DENT-15 i 121 '109 04/88- .H10'

DENT'-

21 'l 121.125 04/88 H6 +.'15.70" DENT- .14 1 122-:102 04/88 H10

DENT..

11

122-106 04/88 H10
DENT-31-

. i 122 :112- -04/88 ,H10 DENT 17' '123-2105.04/88 H10 . DENT 6 123-107-04/88 1H10 DENT 14- '123-111 04/88-H7 + 8.80" DENT 7 04/88 C10 DENT 10-123-113'~04/88-H10 . DENT 27 127-89 04/88 C9 ~+ 19.60" DENT 5-128-110 04/88. H8 + 19.10 "- DENT 15 04/88 C1 + 30.50" DENT 15 129-69 :04/88 C5 + 20.90"' DENT- -26 132- -78 ~04/88 DH DENT 14 133-101' 04/88 DH + 14.60" DENT. 10 135-79 '04/88 CTS-SP + 21.60" DEMT 6 138.

68. 04/88 C10

+ 1.70" DENT 7 . TOTAL' TUBES: 784 .i. I 1 i_________._______.__

1: 1 STEAM GENERATOR 11 I. List with Plot of Tubes Plugged during the April / June 1988 Outage f 8 / O

l! j;I! l 4l!j l v - N W m=""a, e=s e s e e, a 0 s, e S 0 8. e 0 a s a s s, e s E 8 1 s t 1 1 1 t-, - - - -.. - -, - %.1j ,E ~ M y '"'g(v W 9 i k 8 4 1 5 2 k D: k EN 7 O IS S E A T J EB: S k U) E T0 S ( I LS i k AY L TA AT k OT O TS T EG k AT P U i ' k O 88 , n k ,t / 4 k k D (0 ) E N G t ~ iR O G 1 I 74 T U A .R C ~ L R I D d,, ' P O N S 5 T I E l e A E D i .R E \\') / R. S R L 0 F IL E E P 0 .R N I 1 I B E T. U G sa 5 .R l T ~" = a F .R O g p 5 T O n 8 L gs P .E 1 =- 1 .a e G S i TI .R NU A S .a 5 F E T F 3 A I 4 .a L L r ( C6 B 8 w T .a T/ m T R4 S E0 e s I Y 5 L AC D E .t e TG L m 8

E:

s U i. NA P 0 J AT 2 7 A LU [IL PO 3 53g !g,aII ,a.g E g f 1

......,,,,.;,......m.. ...e........... m.... ~. m....... rey P1 ant: CALVERT CLIFFS UNIT 1 Steam G e r.e r a t e r : 11 Outage: 04/88 l QUERY: PLUGGED - MECH-W, HTS-PF (OUT OF SEEV),ALL-RL ROW-LINE OUTAGE FLEVAT~nN INDICATION 11-147 04/88 H-TS-PF PLUGGED - MECH-W D7-33 04/88 HTS-PF PLUGGED - MECH-W 31-135 04/88 HTS-PF PLUGGED - MECH-W 45-51 04/88 HTS-PF PLUGGED - MECH-W 45-55 04/88 HTS-PP PLUGGED - MECH-W 46-52 04/88 HTS-PF PLUGGED - MECH-W 50-16 04/88 HTS-PF PLUGGED - MECH-W 50-56 04/88 HTS-PF PLUGGED - MECH-W 51-111 04/88 HTS-PF PLUGGED - MECH-W 52-58 04/88 HTS-PF PLUGGED - MECH-W 52-110 04/88 HTS-PF PLUGGED - MECH-W 54-56 04/88 HTS-PF PLUGGED - MECH-W 54-58 04/88 HTS-PF PLUGGED - MECH-W 54-110 04/88 HTS-PF PLUGGED - MECH-W 55-57 04/88 HTS-PF PLUGGED - MECH-W 56-58 04/88 HTS-PF PLUGGED - MECH-W 56-62 04/88 HTS-PF PLUGGED - MECH-W 57-109 04/88 HTS-PP PLUGGED - MECH-W 59-57 04/88 HTS-PF PLUGGED - MECH-W 69-85 04/88 HTS-PF PLUGGED - MECH-W 69-93 04/88 HTS-PF PLUGGED - MECH-W 70-92 04/88 HTS-PF PLUGGED - MECH-W 71-83 04/88 HTS-PF PLUGGED - MECH-W 71-- 89 04/88 HTS-PF PLUGGED - MECH-W 71-93 04/88 HTS-PF PLUGGED - MECH-W 72-90 04/88 HTS-PF PLUGGED - MECH-W 73-89 04/88 HTS-PF PLUGGED - MECH-W 74-86 04/88 HTS-PF PLUGGED - MECH-W 74-88 04/8E HTS-PF PLUGGED - MECH-W 74-92 04/88 HTS-PF PLUGGED - MECH-W 75-85 04/88 HTS-PF PLUGGED - MECH-W 93 04/88 HTS-PF PLUGGED - MECH-W -G 75-77-89 04/88 HTS-PF PLUGGED - MECH-W 78-88 04/88 HTS-PF PLUGGED - MECH-W 79-89 04/88 HTS-PF PLUGGED - MECH-W 103-125 04/88 HTS-PF PLUGGED - MECH-W 134-108 04/88 HTS-PF PLUGGED - MECH-W 136-68 04/88 HTS-PF PLUGGED - MECH-W 138-68 04/88 HTS-PF PLUGGED - MECH-W 138-76 04/88 HTS-PF PLUGGED - MECH-W 139-75 04/88 HTS-PF PLUGGED - MECH-W 139-87 04/88 HTS-PF PLUGGED - MECH-W TOTAL TUBES: 42 O

O Pago!1 o'f 5- ,m 0 'I . Steam Generator.i11 Tubes Plugged'.During the April.19881

outage:

. BQH -. lit [E REASON FOR PIEGGING 11' '147 ~ Eddy Current ~ Testing Indication of 57% wall loss originating on. the outside diameter of.the tube at DH+2.10 inches. ~ 27 33 Eddy Current Testing Indication of 59% wall loss originating -on the outside l diameter of the tube at C2+33.80 inches. I 45 51 -Eddy Current Testing Indication of. 48% wall-loss originating on the outside diameter of the' tube at HTS-SF+0.76 inches. 45 55 Eddy Current Testing Indication of 52% wall loss originating on the outside diameter of the tube at HTS-SF+1.03 inches. 50 16 Eddy Current Testing Indication of 47% wall loss originating on the outside-diameter of the tube at H4+8.67 inches. f 54 58 Eddy Current Testing Indication of 64% O wall loss originating on the outside diameter of the tube. at HTS-SF+0.64 inches. 55 57 Eddy Current Testing Indication of 48% wall loss originating on the outside diameter of the tube at HTS-SF+0.82 fl inches. 69 93 Eddy Current Testing Indication of 61% wall loss originating on the. outside c diameter of the tube at HTS-SF+1.10 inches. 70 92 Eddy Current Testing Indication of 48% wall loss originating on the outside diameter of the tube at HTS-SF+0.80 inches. 71 83 Eddy corrent Testing Indication of 44% wall loss originating on the outside diameter of the tube at HTS-SF+0.70 inches. 7 O L L

I P;g3 2 of 5 Steam Generator fil Tubes Plugged During. the April' 1988 ~' Outage: BQH LINE EFMQLEOAILUGGING 73 89 Eddy Current Testing Indication of 47% i wall loss originating on' the outside diameter of the tube at HTS-SF+0.50 inches. i 74 86 Eddy Current Testing Indication of 49% wall loss originating on the outside diameter of the tube at HTS-SF+0.60 inches. 74 92 Eddy Current Testing Indication of 62% wall loss originating on the outside diameter of the tube at HTS-SF+0.60 inches. 75 85 Eddy Current Testing Indication of 46% wall loss originating on the outside diameter of the tube at HTS-SF+0.70 inches. 75 93 Eddy Current Testing Indication of 41% wall loss originating on the outside -(~] diameter of the tube at HTS-SF+2.80 (_,/ inches. 77 89 Eddy Current Testing Indication of 43% wall loss originating on the outside diameter of the tube at HTS-SF+1.80 inches. 78 88 Eddy Current Testing Indication of 42% wall loss originating on the outside diameter of the tube at HTS-SF+1.40 inches. 103 125 Eddy Current Testing Indication of 54k wall loss originating on the outside I diameter of the tube at VH+0.00 inches. 134 108 Eddy Current Testing Indication of 48% wall loss originating on the outside i diameter of the tube at HTS-SF+12.60 inches. 136 68 Eddy Current Testing Indication of 56% wall loss originating on the outside jr dicmeter of the tube at CTS-SF+10.60 r inches.

P;g3 3 of 5 Steam Generator til Tubes Plugged During the April 1988' ~ p) Outage: -y l BQ]! LINE BEMiDE_ZDE_PldEiG.UG 138 76 Eddy Current Testing Indication of 48% wall loss originating on the outside diameter of the tube at CTS-SF+11.00 inches. 31 135 Eddy Current Testing Indication of a bulge above the tubesheet from CTS-SF+0.00 inches to CTS-SF+23.70 inches. 46 52 Eddy current Testing Indication of 38% wall loss originating on the outside diameter of the tube at HTS-SF+2.20 inches. 50 56 Eddy Current Testing Indication of 23% wall loss with high voltage signal originating on the outside diameter of the tube at HTS-SF+0.64 inches. / 51 111 Eddy Current Testing Indication of 39% gs wall loss with high voltage signal i originating on the outside diameter of the tube at HTS-SF+0.80 inches. 52 58 Multiple Eddy Current Testing-Indica-tions of 22%, 12% and 16% wall loss originating on the outside diameter of the tube at HTS +SF+2.55,+1.79 and +1.09 inches, respectively. 52 110 Eddy Current Testing Indication of 23% wall loss with high voltage signal' originating on the outside diameter of the tube at HTS-SF+0.70 inches. 54 56 Eddy Current Testing Indication of 37% wall loss with high voltage signal originating on the outside diameter of the tube at HTS-SF+0.64 inches. 54 110 Eddy Current Testing Indication of 34% wall loss with high voltage signal originating on the outside diameter of the tube at HTS-SF+0.80 inches. r

L ? P;ga 4 cf 5 e 7 Steam' Generator i11 Tubes-Plugged-During the April1988. ( outage: BQlf - LINE REASON FOR PIEGGING 56 58 Eddy ~ Current TestingJIndication of 35% wall loss with high voltage signal originating on the-outside diameter of the tube at HTS-SF+0.79 inches. ~ 57 109 Eddy Current Testing Indication of 17% wall loss with high voltage _ signal originating on the outside diameter of the tube at HTS-SF+2.70, inches. 59-57 Eddy Current Testing Indication of 38% wall loss originating on the outside v diameter of the tube at HTS-SF+1.20 inches. 56 62 Eddy Current Testing Indication of a bulge above the tubesheet from HTS-SF+0.00 inches to HTS-ST+2.00 inches. 69 85 Eddy Current Testing Indication of 38% wall loss originating on the outside <-'s I diameter of the tube at HTS-SF+1.70 'Q inches. 71 89 Hultiple Eddy Current Testing Indica-tions of 35% and 31% wall loss originat-ting on the outside diameter of the tube at HTS-SF+0.90 and +0.60

inches, respectively.

71 93 Hultiple' Eddy Current Testing Indica-tions of 31%, 28% and 23% wall loss originating on the outside diameter of the tube at HTS-SF+1.10, +1.80 and +0.60 inches, respectively. 72 90 hultiple Eddy Current Testing Indica-tions of 38% and 34% wall loss originat-ing on the outside diameter of the tube at HTS-SF+0.60 and +1.20 inches respectively. l ()

L P;ga 5 cf 5 i Steam Generator fil Tubes Plugged During the April 1986 / '. Outage: -( BQi[ Zill[E REASON FOR PIDGGING 74 88 Eddy Current Testing Indication of 23% wall loss with high voltage signal originating on the outside diameter of the tube at HTS-SF+1.00 inches. 79 89 ' Eddy Current Testing Indication of 31% wall loss originating on the outside diameter of the tube at HTS-SF+1.70 inches. 138 68 Eddy current Testing Indication of 36% wall loss originating on the outside diameter of the tube at CTS-SF+10.40 inches. 139 75 Eddy Current Testing Tube Sheet Crevice Squirrel (SQR) Indication showing wall loss originating on the outside diameter of the tube at HTS-SF-2.00 inches. ( 139 87 Eddy Current Testing Tube Sheet Crevice SQR Indication showing wall loss origi-nating on the outside diameter of the O tube at HTS-SF-1.00 inches. ( ($) 4 \\

. ) O APPENDIX. II EDDY CURRENT TEST RESULTS STEAM GENERATOR 12 A. List with Plot of All Ir.dications B. List'with Plot of <20% Indications C. List with Plot of 20%-39% Indications D. List with Plot of >39% Indications E. List with Plot of. Distorted Indications F. Lists-with Plots of Tubes not Rolled G. Lists with Plots of Sludge Data H. List of Tubes Dented I. List with Plot of Tubes Plugged During the April / June 1988 Outage 'I O 4 4 4 i O

I i l STEAM GENERATOR 12 A. List with Plot of All Indications ' O 1 O

J_ , \\ 9 1 3 5 6 y 8 8 8 2 1 8 R ) E 5 1 N = s E 7 1 G ( I 3 G S 3 A S 9 S 3 A T E B: 0 S U L) 2 E Tf B O t w ( 7 LS 0 AY 0 L 8 TA A = a = T 8 OT O TS 5 T / 4 S, P i I j )7 N ,g O g I _i-g 3 8 i g g T 1 ,s l g = y A +r V = E 'u i s. L E )

n:8 u

9 8, 2 l ( 8. i l ".t, L 2 N g ~ O r 1 L I 3 " T as A A C ,a h )I I 0 R 3 D t I m O 1 N S m E 1 S T ( I 8 A D 1 0 E 9 a )J N R 2 L 0 8 j 5 O E < P 8 8 5,y g ,L N I ( I E - T. ) n. 1 a t a T G 0 i 5 0 N = = s A C ~ 8; 3 1 e s I u .~ D 8 n t N s. s g i a a_ I a ar. I J i j O 5 a L ,' 8 g L 3 8 g a A l t o 8 .a e F g-O 3 9 g .s T O 8 L 4 1 P T I 2 N a O U 1 w SF G F S I L C8 u 8 T/ ) O 0 ( a R4 ) E0 L2 V A1 L I( C A E9 C P3 a S> ) NA 00 E s

TG 00 AT

)J LU PO L4 ...,(%

[,o u
  • g*

.g f a;E .w 9 E I l,

^I ,3g lv 0 8 0 5 0 6 0 5 0 S 0 5 0 S 5 0.O g #,, 5 m4#mm,2 a 3 3 2 2 t 1 0 0 S 8 8 5 1 2 s 1 1 1 1 t 1 2 1 - - - - - - - - - -, - -

  • _ ~ _ -. " ~ - - _ - - - -

) a B. v G 4g3 ~E E D (. 09 9 1 5 2 8 9 1 E R G ) N E s A 7 e G T t I s S 9 S U S 3 A E O B: 0 S U) 2 EB TW U e 8 ( T 8 LS 0 AY 0 L / TA T g A 4 OT O i TS 3 T 8 8 T 1 I E s 'l E 3 H d'g g: S s t g t E i { g B t 1 .F* 4: a U T i m s a 0 G sa 1 u ) E 2 y.F' t, 2 ( L t t .', a_j 8 s s s 2 P e O 8 w _I T 1 I a T .s -' O A a ,.{ C a H 12D I.* I 1 ;.g R O m. ) E T 13N S I

W S

I E i ea E w V R 2L 0 L A 0E D e N I ,( O E < P 8 1 g a N I e 1 B E T a, f~ s a L A G 0U 3 I e 0N e e - = S s N i Oi 1m a a O t i g ui a I a e T s_ e a-A a e C = 8 I 3 a a D e N 8 I 1-a e g e F = l O S T e t 1 O T L I ea P N A U W a e 2 S E F T 1 FI aa u L s G C8 e S 8 ) r T/ (0 ea E0 Lo) r R4 o n N V At e I( L c A Ee C p3 n s> a G 00 e m T: E: s yO NA 00 ~ 7 AT = - 2 LU t PD L4 y ,2 g 1 o5 g E g g i I [,. d g. i il il i

...... en s enasine ev 3. s.ei...... n. o r o.ir :. nu o.n u...... comesa o asseea se. 0o.000 na p Plant CALVERT CLIFFS UNIT 1 Steas Generator: 12 ' Outage 04/88 OUERY: OD,ALL % TW,ALL VOLTS,ALL ELEY (ALL TUBES),ALL-RL ROW-LINE OUTAGE ELEVATION INDICATION % TW VOLTS ( 1-37 04/88 H2 + 10.10" OD 13 0.96 1-45 04/88 CTS-SF + 0.50" OD 49 0.48 2-44 04/88 HTS-SF + 1.40" OD 10 0.61 04/88 CTS-SF + 0.50" OD 23 0.60 3-9 04/88 C5 + 4.10" OD 36 1.27 3-31 04/88 CTS-SF + 26.40" OD 16 0.61 4-144 04/88 CTS-SF + 4.00" OD 16 0.54 5-139 04/88 C4 + 15.90" OD 15 0.76 6-40 04/88 H1 + 22.30" OD 16 0.52 6-108 04/88 HTS-SF + 0.90" OD 18 0.81 6-150 04/88 C2 + 4.90" OD 17 0.57 7-1 04/88 H4 .OD 11 0.73 8-108 04/88 HTS-SF + 1.10" OD 11 1.06 8-152 04/88 VM OD 24 0.90 9-25 04/88 VM OD 19 1.17 9-31 04/88 VM OD 11 0.99 9-109 04/88 HTS-SF + 0.90" OD 26 0.49 10- 108 04/88 HTS-SF + 1.40" OD 38 0.92 10- 110 04/88 HTS-ST + 0.70" OD 19 0.79 11-109 04/88 HTS-SF + 1.60" OD 31 0.76 12-156 04/88 C2 + 25.80" OD 23 0.76 13-135 04/88 C5 + 11.80" OD 33 0.84 14-146 04/88 HTS-SF + 29.40" OD 13 0.72 16-62 04/88 C1 + 29.70" OD 11 0.52 17-63 04/88 C2 + 24.80" OD 28 0.53 17-111 04/88 HTS-SF + 1.40" OD 11 0.48 19-19 04/88 HTS-SF + 13.30" OD 12 0.87 19-25 04/88 CTS-SP + 12.10" OD 11 0.85 19-111 04/88 HTS-SF + 1.40" OD 22 0.65 20-34 04/88 HTS-SF + 33.70" OD 36 0.59 21-145 04/88 HTS-SF + 23.60" OD 27 0.65 f 132 04/88 HTS-ST + 0.70" OD 10 0.80 O 22-22-148 04/88 CTS-SF + 36.10" OD 26 0.69 23-113 04/88 HTS-SF + 1.10" OD 13 0.66 25-111 04/88 HTS-SF + 0.90" OD 22 0.83 26-130 04/88 HTS-SF + 0.80" OD 11 0.75 26-132 04/88 HTS-SF + 0.90" OD 11 0.74 27-33 04/88 H5 + 37.50" OD 18 0.50 04/88 C5 + 21.50" OD 11 0.44 27-129 04/88 HTS-SF + 0.90" OD 11 0.91 28-42 04/88 HTS-SF + 1.10" OD 10 1.29 28-56 04/88 HTS-SF + 0.90" OD 15 1.30 29-41 04/88 HTS-SF + 0.80" OD 27 0.65 29-69 04/88 HS + 4.00" OD 38 0.50 30-40 04/88 HTS-SF + 0.80" OD 23 0.82 30-60 04/88 CTS-SF + 17.20" OD 10 1.34 30-64 04/88 C2 + 23.10" OD 39 0.51 30- 128 04/88 HTS-SF + 0.70" OD 17 0.66 31-41 04/88 HTS-SF + 0.70" OD 47 0.64 31-101 04/88 CTS-SF + 1.10" OD 13 0.73 31-123 04/88 HTS-SF + 0.70" OD 16 0.67 31-125 04/88 HTS-SF + 1.00" OD 12 0.42 31-127 04/88 HTS-SF + 0.80" OD 11 1.78 31-137 04/88 HI + 2.10" OD 23 0.73 32-40 04/88 HTS-SF + 0.70" OD 42 0.89 32-126 04/88 HTS-SF + 0.90" OD 16 0.55 32-148 04/88 C6 + 15.30" OD 22 0.89 22 1.04 33-41 04/88 HTS-SF + 0.80" OD 33-115 04/88 HTS-SF + 0.90" OD 23 0.41 23 0.58 i 34-12 04/88 HTS-SF + 30.50" OD 34-150 04/88 DC OD 12 1.97 l 35-61 04/88 H2 + 13.80" OD 24 0.64 18 0.53 35-99 04/88 C4 + 9.40" OD 26 0.43 37-55 04/88 HTS-SP + 1.90" OD 12 0.59 38-48 04/88 HTS-SF + 0.80" OD f 0 ~' - - " ~ -, - -

F Plonte CALVERT CLIFFS UNIT 1 Stoaa Gsnorator: 12 Outogos 04/88 QUERY: OD,ALL % TW,ALL VOLTS,ALL ELEY-(ALL TUBES),ALL-RL Q ROW-LINE OUTAGE ELEVATION INDICATICN % TW YOLS 38-112 04/88 HTS-SF + 0.90" OD 12

1. :('

39-47 04/88 HTS-SF + 0.50" OD 17 0.k 39-53 04/88 HTS-SF + 1.90" OD 19 0.4 39-57 04/88 HTS-SF + 1.40" OD 27 0.- 39-121 04/88 HTS-SF + 0.90" OD 10 0. 40-120 04/88 HTS-SF + 1.40" OD 10 0. 40- 122 04/88 HTS-SF + 1.60" OD 16 0. 41-39 04/88 H6 + 1.10" OD 18 0.( 41-47 04/88 HTS-SF + 0.70" OD 10 1.1 41-49 04/88 HTS-SF + 0.80" OD 39 0.< 41-53 04/88 HTS-SF + 2.00" OD 16 0.t 41-61 04/88 H5 + 36.00" OD 28 0.t 41-89 04/88 H1 + 20.60" OD 35 0.f 42-16 04/80 HI + 17.40" OD 16 1. 42-110 04/88 HTS-SF + 8.80" OD 13 0.1 42-114 04/88 H1 + 8.60" OD 36 0.f 42-116 04/88 HTS-SF + 0.70" OD 31 0.1 43-81 04/88 HTS-SF + 27.10" OD 17 0.1 43-113 04/88 HTS-SF + 1.90" OD 23 0.1 44-12 04/88 DC + 6.00" OD 15 0.1 44-20 04/88 H5 + 12.50" OD 24 0.1 44-50 04/88 HTS-SF + 1.80" OD 16 0.t 44-114 04/88 HTS-SF + 2.70" OD 19 0., 44-116 04/88 HTS-SF + 3.90" OD 15 0.' 44-118 04/88 HTS-SF + 2.50" OD 25 0., 45-51 04/88 HTS-SF + 1.60" OD 15 0.- 45-117 04/88 HTS-SF + 2.50" OD 27 0., 46-112 04/88 HTS-SF + 1.50" OD 11 0.1 l 46-116 04/88 HTS-SF + 2.80" OD 10 0.; f 47-51 04/88 HTS-SF + 1.00" OD 15 O. I 47-57 04/88 HTS-SF + 1.50" OD 19 0.: f 47-111 04/88 HTS-SF + 0.80" OD 19 0. 47-113 04/88 HTS-SF + 0.60" OD 19 0. C 47-117 04/88 HTS-SF + 0.70" OD 24 1. 47-157 04/88 H7 + 9.80" OD 36 0. 48-8 04/88 H5 + 4.50" OD 15 O. 48-52 04/88 HTS-SF + 1.70" OD 10 0. 04/88 HTS-SF + 2.30" OD 11 1. 48-58 04/88 HTS-SF + 2.30" OD 27 0. 48-86 04/88 C3 + 26.40" OD 13 0. l 48-112 04/88 HTS-SF + 2.30" OD 28 0. l ( 48-146 04/88 H2 + 25.00" OD 24 0. 49-61 04/88 HTS-SF + 2.10" OD 28 0. 49-117 04/88 HTS-SF + 2.30" OD 18 0. l 50-64 04/88 HTS-SF + 2.00" OD 35 O. SI-59 04/88 HTS-SF + 2.20" OD 23 0. 51-63 04/88 HTS-SF + 2.40" OD 10 00 51-113 04/88 HTS-SF + 2.80" OD 15 00 52-60 04/88 HTS-SF + 2.00" OD 16 Oc 52-154 04/88 C5 + 26.50" OD 22 00 04/88 H2 + 35.90" OD 15 Oc 53-49 04/88 C6 + 3.60" OD 12 Oo 53-55 04/88 H3 + 32.60" OD 22 Oc 53-59 04/88 HTS-SF + 0.90" OD 31 00 53-65 04/68 HTS-SF + 1.80" OD 36 Oc 53-113 04/88 HTS-SF + 0.80" OD 38 00 '1.90" OD 24 00 53-159 04/88 C3 + .!.00" OD 13 00 54-56 04/88 HTS-SF + 54-110 04/88 HTS-SF + 2.30" OD 24 Oc 04/88 HTS-SF + 2.10" OD 23 00 55-69 04/88 HTS-SF + 1.50" OD 11 00 55-113 04/88 HTS-SF + 0.90" OD 39 00 55-117 04/88 HTS-SF + 1.00" OD 26 10 56-62 04/88 HTS-SF + 2.50" OD 33 00 04/88 HTS-SF + 2.20" OD 12 00 f O

Plcnt CALVERT CLIFFS UNIT 1 Stcon Gonorator: 12 Outagos-04/88 L -QUERY: OD,ALL % TW,ALL' VOLTS,ALL ELEY (ALL TUBES),ALL-RL n ( I ROW-LINE OUTAGE ELEVATION INDICATION % TW VOLT %/. 04/88 . HTS-SF + 1.00". OD 32

1. 6l 56-102 04/88 HTS-SF

+ 1.40" OD 13 0.9 56-104 04/88 HTS-SF + 0.60" OD .22

0. 6' 56-112 04/88 HTS-SF

+ 1.00" OD 11

0. 9-57-71 04/88-HTS-SF

+ 1.40" OD 13 0. 7. 57-~105 04/88 HTS-SF + 0.60" OD 18 0. 9. .57-107 04/88 HTS-SF + 2.20" OD 19 0. 5, 04/88 HTS-SF + 0.80" OD 31

1. O~

57-111 04/88 HTS-SF + 1.30" OD 11 1.1l 58-66 04/88 HTS-SF + 2.10". OD 10

0. 5' 58-106 04/88 HTS-SF

+ 2.80" OD 13 0.G 04/88 HTS-SF- + 1.70" OD 17

0. 6' 58-110- 04/88' HTS-SF

+ 2.60" OD 22 1.1: 59-63 04/88 HTS-SF + 1.10"' OD 28

0. 5l 60-50 04/88 C2

+ 11.10" OD 12 0.7 60-58 04/88 HTS-SF + 0.60" OD 16'

2. 2:

60-60 04/88 HTS-SF + 0.60" OD 28 0.9 60-64 04/88 HTS-SF + 1.00" OD 32' O. 5' 60-66 04/88 HTS-SF + 2.10" OD 11' 1.4 60- 108 04/88 HTS-SF + 2.50" OD 18-0. O' 61-63 04/88 HTS-SF + 11.40" OD 13

0. 6' 61-65 04/88.

HTS-SP + 0.70" OD 42 1. 61-67 04/88 HTS-SF + 1.90" OD 10 0. 61-71 04/88 HTS-SF + 1.90" OD 10 0. 61-105 04/88 HTS-SF + 1.00" OD 49 0. 62-42 04/88 CTS-SF + 1.00" OD 37 0. 62-68 04/88 HTS-SF + 1.70" OD 10 0.G 62-72 04/88 HTS-SF + 2.20" OD 11 0.5 62-76 04/88 HTS-SF + 2.10" OD 17 0. 62-100 04/88 HTS-SF + 0.90" OD 35 O. 62-102 04/88 HTS-SF + 1.10" OD 31 1. 62-104 04/88 HTS-SF + 1.20" OD 26

1. O(:

/' 63-57 04/88 C3 + 37.50" OD 10 0.9 04/88 C4 + 6.70" OD 37 0. 7. 63-71 04/88 HTS-SF- + 2.50" OD 18

0. 5' 63-105 04/88 HTS-SF

+ 1.40" OD 10 0.5 64-24 04/88 H5 + 11.00" OD 15

0. 5' 04/88 H6

+ 9.90" OD 11

0. 4, 04/88 H6

+ 19.40" OD 16 0. 51 64-64 04/88 HTS-SF + 1.70" OD 34 0. 51 64-76 04/88 HTS-SF + 2.40" OD 10

0. 6l 64-78 04/88 HTS-SF

+ 2.30" OD 15

0. 4l

~64-102 04/88 HTS-SF + 0.60" OD 10 1.2 65-71 04/88 HTS-SF + 2.70" OD 16 0.8 65-103 04/88 HTS-SF + 1.40" OD 13

0. 4i 66-68 04/88 HTS-SF

+ 2.10" OD 24

0. 9<

66-100 04/88 HTS-SF + 1.40" OD 21

0. 7' 04/88 C3

+ 23.10" OD 17

0. 8l 66-102 04/88 HTS-SF

+ 2.30" OD 18 0. 94 66-152 04/88 C4 + 31.10" OD 13 0. 61 67-- 97 04/88 HTS-SF + 0.80" OD 31

0. 6!

67-101 04/88 HTS-ST + 1.70" OD 16

0. 8' 68-.70 04/88 HTS-SF

+ 0.50" OD 28

0. 6!

68-74 04/88 HTS-SF + 0.80" OD 29 0. 44 04/88 HTS-SF + 1.20" OD 38 0.5: 68-94 04/88 HTS-SF + 0.70" OD 35

1. 3!

'68-96 04/88 HTS-SF + 1.40" OD 15 0. 54 68-98 04/88 HTS-SF + 0.60" OD 13

1. 4:

68-100 04/88 HTS-SF + 1.70" OD 19 0.9 68-102 04/88 HTS-SF + 0.80" OD 18

0. 9!

68-108 04/88 CTS-SF + 10.20" OD 27 0. 41 68-128 04/88 C4 + 30.50" OD 29

0. 8(

69-61 04/88 DH + 23.30" CD 23 0.6 I 69-95 04/88 H5 + 33.10" OD 34

1. 0l l

69-97 04/88 HTS-SF + 0.50" OD 16-

1. 2, l

7 Plant: CALVERT CLIFFS UNIT 1 Stoan Gonorotor: 12 Outogo 04/88 QUERY: OD,ALL % TW,ALL VOLTS,ALL ELEY (ALL TUBES),ALL-RL' ROW-LINE OUTAGE ELEVATION INDICATION t TW YOLT 69-99 04/88 HTS-SF + 3.00" OD 26 0. 0-69-143 04/88 C4 + 2.90" OD 15 1.@ 70-70 04/88 HTS-SF + 1.10" OD 25

0. 4, 70-78 04/88 HTS-SF

+ 0.00" -OD 35

0. 6; 70-84 04/88 IITS-SF

+ 0.70" OD 45

0. 4' 70-92 04/88 HTS-SF

+ 1.10" OD 33

0. 5; 70-94 04/88 HTS-SF

+ 2.60" OD 28

0. 4.

70-96 04/88 HTS-SF + 0.70" OD 64

0. 6; 70- 100 04/88 HTS-SF

+ 1.50" OD 32

0. 6-70- 102 04/88 HTS-SF

+ 1.60" OD 39 0.6 70- 110 04/88 H2 + 10.60" OD 10 0. 51 70- 150 04/88 C3 + 22.70" OD 38 0.5; 71-75 04/88 HTS-SF + 3.80" OD 11

0. 4' 71-79 04/88 HTS-SF

+ 1.30" OD 31

0. 4-71-81 04/88 HTS-SF

+ 1.10" OD 12

1. 5' 71-97 04/88 HTS-SF

+ 0.50" OD 47 0.9 72-78 04/88 HTS-SF + 0.90" OD 39

0. 4' 72-90 04/88 HTS-SF

+ 1.20" OD 32

0. 4:

73-89 04/88 HTS-SF + 0.80" OD 24 1.1, 73-93 04/88 HTS-SF + 0.70" OD 54

0. 6l 73-97 04/88 HTS-SP

+ 0.50" OD 36 1.2 04/88 HTS-SF + 1.10" OD 19 1. 04/88 HTS-SF + 1.70" OD 39 0. I 73-99 04/88 HTS-SF + 1.10" OD 26 1. 74-76 04/88 HTS-SF + 0.60" OD 36 1. 74-86 04/88 HTS-SF + 1.40" OD 38

1. 4; 74-90 04/88 HTS-SF

+ 1.50" OD 18

0. 6l 04/86 HTS-SF

+ 1.80" OD 12 0.4 74-92 04/88 HTS-SF + 1.70" OD 21

0. 7<

74-94 04/88 HTS-SF + 0.50" OD 13 1.0 04/88 HTS-SF + 1.10" OD 28

0. 7, 04/88 HTS-SF

+ 1.40" OD 33 0.0 1 74-96 04/88 HTS-SF + 0.60" OD 45

3. 0' V

04/88 HTS-SF + 1.60" OD 15 1.f3 75-87 04/88 HTS-5F + 1.40" OD 38

0. 6' 75-89 04/88 HTS-SF

+ 1.60" OD 19 0. 7. 04/88 HTS-SF + 1.90" OD 31 0.4 75-91 04/88 HTS-SF + 1.60" OD 19

1. 3 <

75-95 04/88 HTS-SF + 0.70" OD 67

0. 8; 76- -78 04/88 HTS-SF

+ 0.90" OD 12

0. 9' 04/88 HTS-SF

+ 1.80" OD 16

0. 9(

76-84 04/88 HTS-SF + 3.50" OD 18

0. 4t 76-86 04/88 HTS-SF

+ 3.00" OD 29

0. 4(

76-90 04/88 HTS-SF + 1.50" OD 28 1.9 04/88 HTS-SF + 3.00" OD 34 0.5( l 76-92 04/88 HTS-SF + 0.60" OD 53

0. 5l 04/88 HTS-SF

+ 1.60" OD 33 1. 31 77-59 04/88 H2 + 16.60" OD 11

0. 7' 12 0.7' 77-79 04/88 HTS-SF

+ 1.70" OD 77-81 04/88 HTS-SF + 1.30" OD 10

0. 7 ;

04/88 HTS-SF + 1.60" OD 23

1. 0; 77-85 04/88 HTS-SF

+ 2.70" OD 52

0. 4(

77-87 04/88 HTS-SF + 1.70" OD 28

0. 5{

04/88 HTS-SF + 2.80" OD 13

0. 6!

l 04/88 HTS-SF + 3.00" OD 28

0. 8C

.77-89 04/88 HTS-SF + 1.70" OD 33

0. 9(

04/88 HTS-SF + 2.20" OD 43 0.6' 04/88 HTS-SF + 2.70" OD 32 0.4( 04/88 HTS-SF + 3.20" OD 25

0. 9!

77-153 04/88 H4 + 31.20" OD 13

1. 0; 78-80 04/88 C5

+ 26.00" OD 28

0. 7!

78-86 04/88 HTS-SF + 0.60" OD 44

1. 2l 04/88 HTS-SF

+ 1.60" OD 31

0. 8C 04/88 HTS-SF

+ 2.60" OD 39

1. 0j 78-88 04/88 HTS-SF

+ 2.80" OD 13

1. 0(

f O

Plants CALVERT CLIFFS UNIT 1 Stoon Gonorators 12 Outogo 04/88 QUERY: OD,ALL % TW,ALL YOLTS,ALL ELEY (ALL TUBES),ALL-RL V ROW-LINE OUTAGE ELEVATION INDICATION % TW VOLT! 04/88-HTS-SF + 6.10" OD 22

0. 4(

78-90 04/88 HTS-SF + 0.70" OD 25

0. 4{

04/88 HTS-SF + 1.30" OD 47 1.1 < 78-94 04/88 HTS-SF + 0.80" OD 36

0. 9l 78-96 04/88 HTS-SF

+ 0.70" OD 17

0. 5 :

78-114. 04/88 YH + 22.60" OD 10

0. 8C 78-120 04/88 H2

+ 17.80" OD 37

0. 5:

79-53 04/88 C4 + 25.50" OD 31

0. 5l 79-57 04/88 C5

+ 22.50" OD 36

0. 6(

79-61 04/88. H8 + 13.50" OD 18

0. 9t 79-77 04/88-HI

+ 6.50" OD 13

0. 5:

79-79 04/88 C2 + 16.20" OD .36 0. 61 79-81 04/88 HTS-SF + 0.50" OD 38 0. 51 79-83 04/88 HTS-SF + 2.40" OD 22

0. 8' 79-85 04/88 HTS-SF

+ 2.30" OD 16 0.7l 79-91 04/88 HTS-SF + 0.70" OD 35

0. 4 <

79-93 04/88 HTS-SF + 0.70" OD 18

0. 5!

79-95 04/88 HTS-SF + 0.70" OD 10

0. 8l 81-85 04/88 HTS-SF

+ 0.40" OD 31

1. 4; 81-87 04/88 HTS-SF

+ 0.90" OD 21

0. 5' 04/88 HTS-SF

+ 1.30" OD 11 0.4: 04/88 HTS-SF + 1.90" OD 26

0. 7i 81-89 04/88 HTS-SF

+ 1.50" OD 18 0.7 81-91 04/88' HTS-SF + 0.50" OD 19 1. 01 04/88 HTS-SF + 1.50" OD 10 1.@ 81-93 04/88 HTS-SF + 0.40" OD 25 0. 81-111 04/88 HTS-SF + 37.70" OD 15 1. 82-88 04/88 HTS-SF + 1.70" OD 16 0. 82-90 04/88 HTS-5F + 0.60" OD 16 1. 83-19 04/88 H6 + 22.00" OD 38 1. 04/88 H7 + 10.80" OD 12 0. /"T 83-83 04/88 HTS-SF + 0.70" OD 27

1. -

83-91 04/88 H7 + 13.20" OD 35 O. 84-74 04/88 VH + 19.40" OD 24 0. 84-80 04/88 H3 + 34.60" OD 35 0. 84-84 04/88 HTS-SF + 1.40" OD 16 0. 85-21 04/88 H5 + 10.80" OD 38 0. l 85-83 04/88 HTS-SF + 0.80" OD 19 0. l. 87-63 04/88 H7 + 13.80" OD 22 0. i 88-74 04/88 YM OD 19 0. I 90-62 04/88 C4 + 24.30" OD 23 0. 93-81 04/88 C5 + 8.10" OD 31 0. 94-66 04/88 VM OD 56 0. 95-61 04/88 H7 + 9.90" OD 33 0. 95-73 04/88 VM OD 12 1. 96-34 04/88 C7 + 1.40" OD 25 0. 97-73 04/88 YM + 21.40" OD 24 0.. 97-83 04/88 H5 + 21.60" OD 16 0. 98-96 04/88 CTS-SF + 13.80" OD 10 0. 98-116 04/88 C4 + 10.00" OD 12 0. 100-40 04/88 C5 + 1.50" OD 38 0, 200-90 04/88 H3 + 29.40" OD 35 O. 100- 126 04/88 HTS-SF + 8.90" OD 10 0.' 104-88 04/88 VM OD 21 0. 105-39 04/88 HI + 3.10" OD 11 0.-- 106-68 04/88 H5 + 22.10" OD 33 0.- 110- 106 04/88 H7 + 17.20" OD 31 'O.; 113-115 04/88 HI + 3.60" OD 16 0. 123-55 04/88 HI + 33.10" OD 4 0. 125-69 04/88 VC + 9.50" OD 21 2. 133-75 04/88 VM + 17.90" OD 12 0.- 134-66 04/88 HTS-SF + 3.40" OD 3

1..

134-108 04/88 CTS-SF + 0.80" OD 23 0. 137-97 04/88 C10 + 11.20" OD 22 0.- TOTAL TUBES: 286

Ps. V i STEAM GENERATOR 12 B. List with Plot of <20% Indications l l l 1 i h l 1

~ .l I { e 8 9 s 0 e " MS gg4. S,., ,L.. __= e mgna W s 1 1 e 0 s S e g t g i t 1 1 s 1 'E iJ 6 9 1 5 2 8 5 1 8 D: I o g E N 7 G s I 4 o S e S S A E s B: S 4 U) T9 m ( t a f 4. LS o AY a t E TA A T G OT O .m 4. TS s T A T m 6 U O 'l 8 as '= 8 e / 0, e 3 4 8 e 4 4. 6 u 8 m S = N e e O I g T 2 a m 1 A s r C i r .a I R m ,m s D O ( G \\V. N T E s .a i A s D e n I R 0 = u E 1 0 ,8 N 1 .a E 0 G o = a .e 2 ~ 4 s 8 .e F O g w .a s T e O ,.a L e P e .a 2 't - o .a 1 e G .e S 1 o .e T I .a N U 4 u S .a m 1 F 7 ( F a I N m .a n L a C8 I 9 T e T T/ A .a C R4 r E0 nI e G V uI .a I e L r A E C sL s <P .s I m - T E L

TG ot NA aN AT

- = a -,v LU PO oa ,, g.o g* g y g.e -,, EggE .I l

I IPlant: CALVERT CLIFFS UNIT 1: S t a a n. Generator: 12 Loutager: ' 04/88

OUERY: 09,,;39 % TK,ALL yot7'e.p~,~ ELEY (ALL ;gpp~,,.,A,,L-gn

~ ex row-LINE OUTAGE FLEV ATIon' I N D I C A T ! r'"$' t 7g - V O L"' ' (v[ h h,[ 1-37 04/gg g,

  • 10.10" op ho 2-44 04/88

.y g.gr Cb 2 '. O 16 0, o: /h h! 4.00" 09 16- - 0. 5l W 1 0 + 5-139 04/68 c4 + 15.90" OD 15

0. 7; 22.30" op 16
0. b-6-

40 04/88 g1 + f 6-108 04/88' 373,3I + 0.90" oD 18 0.8 6-150 04/88 g3 + 4.90" oD 11 0. 5 '. 1 04/88 H4 OD 11 o,7 9- ' 108 04/88' HTS-ST + 1.10" on 11

1. Di 25 04/88 yg op

}9 l l-31 04/88 yg yj; !6-If fE~5b I20:}$" g '! I :: 8 10 o, g' 1.10" 03. 13 0.6' + 26-130 04/88 HTS- + 0.60" oD 11 o, 7'i 0.90" on .11 0,7 .6-132 04/88 HTS-37.50" oD 18 0.5 27-33 04/88 Hg + 04/88 cf I OD 1L

0. 4, O'00"

.90" OD 11 o,9 4 129 04/88 HTS-Br ,7-8 42 04/88 HTS-Sp 1.10"- .00 10 1*2 + g8-56 04/88 HTS-SF o,90" OD 15 1,3; + 6 + 17.20" op 10 1,3 30-60 04/88: 'hffff 30-~128 04/88 0.70" op 17-06 31-101 04,g8 CTS-SF + 1.10" OD 12 0.7 0.70" oD 16

0. 6' g73,ff 31-123 04/88 jf k'f HTS.

+ 1.00" oD 125 04/88 ]I-j h l-127 04/88 HTS-( 16

0. 5<

(S-O OD l' ] I O O /88 9.40" oD 15 O! 99 04/88 C4 + + 0.90" OD 13 0 h' I + 0.80" OD l' Hf SF 38-48 04/88 l 1, 38-112 04/88 + 0.50" op 17 0'5 39-47 04/88 h[f:SF 39-53 04/88 SF + 1,90" OD -19 o9 39-121 04/88 HTS-SF + 0.90" op 10 o',3 1.40" on 10 0.5 Nff! SP 40- 120 04/88 + + 1.60" oD 16 o,7: 40- 122 04/88 41-39 04/88 H6 + 1.10" oD 18 0 6'. 41-47 04fg8 HTS-SF + 0.70" op to 3.3 + 2,one 99 16 o,4: fS-ST 41-53 '04/88 + 17.40" op 16 1*1 42-16' 04/88 42-110 04/88 HTS-SI + 8.80" oD 13 o,5 hS-ST 0l5 + 27.10" op 17 43-81 04/88 + 6.00" op 15 o6 44-12 04/88 + 1.80" op 16

0. 6' y{j-SP 44-50 04/88

+ 2.70" op 19 o,, 4 HTSjF 44-114 04/88 + 3.90" op 15 0, 9 44-116 04/88 45-51 04/88 HTS-SF + 1.60" op 15 0*4 46-112 04/88 HTS-SE + 1.50" op 11 0, g' + 2.80" oD 10

0. 5' Hfj,-SF 46-116 04/88 g

+ 1.00" OD 15 o*4 47-51 04/88 47-57 04/88 HTS-SI + 1.50" op 19 o,5' 0.80" op 19 0,4 47, 111 04/gg Hf f., SP g + 0.60" oD 19 0.6 47-113 04/88 fh k'f 48-8 04/88 H5 + 4.50" op hS-ST .hh.' 'h 48-52 04/88 HTS-SF 11 1.2 + 26.40" op 13 0,g 48-86 /8 r 49-117 04f8g HTS-SF + 30" OD 18 o, 4, [: /- Iw

,~_n m ~_ h ' Plant: 'CALVERT CLIFFS UNIT 1 Steam Ger.erater: I":; j; Outage: 04/88 QUERY: 00,<20 i TWiALL VOLTS,ALL.ELEY FALL TUBES),ALL-RLL .o -..y (d\\ ROW-LINF OUTAGF ELEVATION INDICATION 't TW VOLT! + 2.40" OD-10

0. 8(

51 ' ' 63l 04/88 ^ HTS-SF 2.80" OD 15

0. 7(

51-113 04/88 H'TS-SF l' 52, 60 04/88 HTS-SF + 2.00" OD Ic 0. 71 35.90" .OD 15.

0. 9(

52 -154 '04/88' H2 + 53-49 04/88~- C6 + '3.60" OD 12

0. 6:

54-z 56 04/88 HTS-ST- + 2.00" OD 13

0. 6 i 55-69=

04/88 . HTS-SF' + 1.50" - OD 11. 0. 41 l-56-62-04/88 HTS-SF + 2.20" OD 12 0.5' l 56-102 04/88 HTS-SP + 1.40" OD 13

0. 8(

56-112 04/88 HTS-SF + 1.00" OD 11 0. 91 57-71 04/88 HTS-SF + 1.40" OD 13

0. 7; 57-105 04/88' HTS-SF

+ 0.60" OD 18 0 ; 91 57-107 04/88 HTS-SF + 2.20" OD 19

0. 5l 57-111 '04/88 HTS-SP

+ 1.30" OD 11

  • 1. 11 58-66-04/88 HTS-SF-

+ 2.10" OD-10

0. 5; 58-~106 04/88 HTS-SF

+ 2.80" OD. 13 08: 04/88 HTS-SF + 1.70" OD 17

0. 6' 60-50 04/88 C2

+ 11.10" OD 12 0.7 60-58 04/88 HTS-SF + 0.60" 'OD 16

2. 2!

60- - 66.04/88 HTS-SF + 2.10" OD 11

1. 4 ;

60- 108 04/88 HTS-SP + 2.50" OD 18

0. 9:

61-63 04/88-HTS-ST + 11.40" OD 13

0. 6:

61-67 04/88 HTS-SF + 1.90" OD 10 0. 51 1.90" OD 10 0.6' 61-71' 04/88 HTS-SF + 62-68 04/88 HTS-SF- + 1.70" OD-10

0. 6:

+

2. 2 0 "-

OD 11-

0. 5, 62-72 04/88 HTS-SF 62-76 94/88

' HTS-SF + 2.10" OD 17

0. 5; 63-57 04/88 C3

+ 37.50" OD 10

0. 5 <

63-71 04/88 HTS-SF + 2.50" OD 18

0. 5:

1.40" OD 10 0.5 63-105 04/88 HTS-SF + I 64-24 04/88 H5 + 11.00" OD 15 0. 51 04/88 H6 + 9.90" OD 11

0. 4:

. [-] 04/88 H6 + 19.40" OD 16

0. 5!

\\ e 64-76 04/88 HTS-SF + 2.40" OD .10

0. 6t V

+ 2.30" OD 15 0. 41 64-78 04/88 HTS-SF 0.60" OD 10

1. 2, 64-102 04/88 HTS-SP

+ 2.70" OD 16

0. 8' 65--

71. 04/88' HTS-ST + 65-103 '04/88 HTS-SF + 1.40" OD 13 0. 41 66-100 04/88 C3 + 23.10" OD 17

0. 8i 66-102 04/88 HTS-SF

+ 2.30" OD 18 0.9; ~ 66-152 04/88 C4 + 31.10" OD 13 0. 61 67-101 04/88 HTS-SF + 1.70" OD 16

0. 8' 96-04/88 HTS-SF

+ 1.40" OD 15

0. 5, 0.60" OD 13 1.4 68-98 04/88 HTS-SF

+ + 1.70" OD 19 0. 9, 68-100 04/88 HTS-SF + 0.80" OD 18 0. 91 68-102 04/88 HTS-SF 69-97' 04/88 HTS-SF + 0.50" OD 16

1. 2, 69-143 04/88 C4

+ 2.90" OD 15 1. 01 70 110 04/88 H2 + 10.60" OD 10 0. 51 71-75 04/88 HTS-SF + 3.80" OD 11 0.4' 71-81 04/88 HTS-SF + 1.10" OD 12

1. 5 -

73-97 04/88 HTS-SF + 1.10" OD 19

1. 3' 74-90 04/88 HTS-SF

+ 1.50" OD 18

0. 6; 04/88 HTS-SF

+ 1.80" OD 12

0. 4; 74-94 04/88 HTS-SF

+ 0.50" OD 13

1. 9:

74-96 04/88 HTS-SF + 1.60" OD 15

1. 8; 75-89 04/88 HTS-SF

+ 1.60" OD 19 0.7

  • 75-91 04/88 HTS-SF

+ 1.60" OD 19 1.3 76-78 04/88 HTS-SF + 0.90" OD 12

0. 9' 04/88 HTS-SF

+ 1.80" OD 16 0.9 3.50" OD 18

0. 4:

76-84 04/88 HTS-SF + 77-59 04/88 H2 + 16.60" -OD 11

0. 7' 77-79 04/88 HTS-SF

+ 1.70" OD 12 0.7 77-81 04/88 HTS-SF + 1.30" OD 10 0.7 .[ 87 04/88 HTS-ST + 2.80" OD 13 0.6 O

"c. esse a m ; ;9 ace w o,v. m mxe woow a yn m w.o --g-iP1hnt : CALVERT - CLIFFS:.' UNIT 1 Steam Generator:,12 - Outage: 04/88 t' TW, ALL1 VOLTS, ALL' ELEV ; ( ALL -TUEES [, ALL-RL ' OUERY:' odd 20 yy I p- 'o',. ' V i. ROW-L.NF OUTAC.E' ELEVATION' !NDICATION t TW VOLTF 77.153' 04/88 H4 +?31.20"~ . OD-13 .1.0 2.80"4 OD; 13-1.0 88.'04/88-HTS-ST '4 78-. 96 04/88 HTS-SF. '+ 0.70'. ODL ' 17 -- 0.5j .VH. .+' 22.60"

OD - 0.~ 8 0 78 -114'.'04/88.

H8- +.13. 5 0 '" OD. -18' O.9q ~ "79-61. 04/88 79-77 04/88~ .H1 + 6.50" OD ~ IST 'O.5 - 0. 7 - 7 9 - -: 85 04/88 HT3-SF +- 2.30"'- OD :: 16 0.5 OD: 18 0.70" '79--'93 04/88-HTS-SF- .+. 79-' 95 04/88 ~ HTS-SF + 0.' 7 0 " OD~ -10:

0. 8f

~ 81-87. 04/88 ' HTS-SF- . + 1.30" - OD 1 11 ' O. 4l 81 < 89- 04/88 . HTS-SF -+ 1.50" OD -18 ' J0. 7 6 81-- 91 04/88 HTS-SF + " 0.50" ,OD 19 .1 '. 8 { 81 <111-04/88. - HTS-SF + 1.50"' OD' '10 ' /1. 0 04/88 HTS-SF- + 37.70" OD 15' 'l.4 11 6

0. 9l 82-88 04/88~

. HTS-SF . + - 1.70" OD 83-' 19 0-04/88 ' HTS-SF -+ 0.60" OD' J16 =1;3: 82-19 04/88. 'H7- + 10.80" OD 12

0. 9; 84-84 04/88.

> HTS-SF- +

1. 4 0 *?

OD 16-0.'41 4 0.80" OD. ~ 19 ' O.5< 85- '83 04/88 HTS-SF ' OD .19

0. 9 t 88. 74 04/88.

VM '95-73-04/88 .VM OD 12-1. 61 '21.60" OD 16. 'O. 91 97-83 04/88 H5 13.80" OD 10

0. 6l 98 - 96 04/88 CTS-ST

' +- 10.00" OD 12,

0. 9) 116- 04/88' C4

+ 4 8.90"' OD' ' 10.

0. 5'

.100--126 04/88. HTS-SF-2.J0" OD ' 1 1. .0.7 105-' '39 04/88 - H1: 3.60" OD 16 . 0. 6: 113-:115- 04/B8 HI +- 123 _ 55 04/88 HI- + - 3 3.10 "- OD di 0.9 17.90". CD 12' O.@ 133 ' 75 04/88 VM + 134-~

66. 04/88 HTS-ST

.+ 3.40" OD 3 1.1 * . TOTAL' TUBES:.152

O 4 STEAM GENERATOR 12 C. List with Plot of 20%-39% Indications O O

.. k 9 l 1 5 8 8 3 1 R N 7 O I m S -S SA E e B; S U) E TW B ( M E LS e AY L G TA A T A OT O T TS a T U O o 8 8 / .a 4 r jj d

=

S 8 N O n I .o o T A 2 C 1 I D m g ;" s N OR m . p. m I T A e ) R e ,( E s e r N s u o 9 E I' 3 G e 0 s 2 = o F

i.

9,;. O r = T O L o P 2 j e 1 G S 1 T IM L ) S 0 F 1( FIL ON C8 I 8 T T/ A C R4 I E0 eC V sP iI L r A <E C L <PI 3 E: TL T: G mM U NA AT = V LU PO o#

E
  • u-I Iie

,i9 E ll+

Plants CALVERT CLIFFS UNIT 1 Stoca GGnarators'12

  • Outogo:

04/88 1 QUERY: CD,20-39 % TW,ALL VOLTS,ALL ELEY (ALL TUBES),ALL-RL { ROW-LINE OUTAGE ELEVATION INDICATION % TW VOLTJ V 2-44 04/88 CTS-SF + 0.50" OD 23

0. 6(

3-9 04/88 C5 + 4.10" OD 36 1.2' 8-152 04/88 VM OD 24

0. 9!

9-109 04/88 HTS-SF + 0.90" OD 26

0. 4(

10- 108 04/88 HTS-SF + 1.40" OD 38

0. 9l 11-109 04/88 HTS-SF

+ 1.60" OD 31 0. 74 12-156 04/88 C2 + 25.80" OD 23 0.7 13-135 04/88 C5 + 11.80" OD 33

0. 8, 63 04/88 C2

+ 24.80" OD 28 0.5: 19-111 04/88 HTS-SF + 1.40" OD 22 0. 61 20-34 04/88 HTS-SP + 33.70" OD 36

0. 5' 21-145 04/88 HTS-SF

+ 23.60" OD 27 0.61 22-148 04/88 CTS-SF + 36.10" OD 26

0. 6' 25-111 04/88 HTS-SF

+ 0.90" OD 22

0. 8:

29-41 04/88 HTS-SF + 0.80" OD 27 0. 61 29-69 04/88 H5- + 4.00" OD 38 0.5! 30-40 04/88 HTS-SF + 0.80" OD 23 0. 8, 30-64 04/88 C2 + 23.10" OD 39 0.5 31-137 04/88 H1 + 2.10" OD 23

0. 7; 32-148 04/88 C6

+ 15.30" OD 22

0. 8' 33-41 04/88 HTS-SF

+ 0.80" OD 22

1. 0-33-115 04/88 HTS-SF

+ 0.90" OD 23 0.4 34-12 04/88 HTS-SF + 30.50" OD 23

0. 5l 35-61 04/88 H2

+ 13.80" OD 24

0. 6, 37-55 04/88 HTS-SF

+ 1.90" OD 26

0. 4' 39-57 04/88 HTS-SF

+ 1.40" OD 27 0.5; 41-49 04/88 HTS-SF + 0.80" OD 39 0.4: 41-61 04/88 H5 + 36.00" OD 28

0. 6' 41-89 04/88 H1

+ 20.60" OD 35

0. 5, 42-114 04/88 H1

+ 8.60" OD 36 0. 0-42-116 04/88 HTS-SF + 0.70" OD 31 0.0-43-113 04/88 HTS-SF + 1.90" OD 23 0.5 ( 44-20 04/88 H5 + 12.50" OD 24 0.9 N 44-118 04/88 HTS-SF + 2.50" OD 25 0.4 ( 45-117 04/88 HTS-SF + 2.50" OD 27 0.0 47-117 04/88 HTS-SF + 0.70" OD 24 1.8 47-157 04/88 H7 + 9.80" OD 36

0. 5, 48-58 04/88 HTS-SF

+ 2.30" OD 27

0. 5l 48-112 04/88 HTS-SF

+ 2.30" OD 28

0. 6l 48-146 04/88 H2

+ 25.00" OD 24

0. 5' 49-61 04/88 HTS-SF

+ 2.10" OD 28

0. 4' 50-64 04/88 HTS-SF

+ 2.00" OD 35 0.4 51-59 04/88 HTS-SF + 2.20" OD 23 0.G; 52-154 04/88 C5 + 26.50" OD 22

0. 5-53-55 04/88 H3

+ 32.60" OD 22

0. 6:

53-59 04/88 HTS-SP + 0.90" OD 31

0. 4-53-65 04/88 HTS-SF

+ 1.80" OD 36

0. 9' 53-113 04/88 HTS-SF

+ 0.80" OD 38 0.9 53-159 04/88 C3 + 23.90" OD 24

0. 7:

54-110 04/88 HTS-SF + 2.30" OD 24 0.G 04/88 HTS-SF + 2.10" OD 23 0. 55-113 04/88 HTS-SF + 0.90" OD 39 0. 55-117 04/88 HTS-SF + 1.00" OD 26 1.9 56-62 04/88 HTS-SF + 2.50" OD 33 0.. 04/88 HTS-SF + 1.00" OD 32 1. 56-104 04/88 HTS-SF + 0.60" OD 22 0. 57-107 04/88 HTS-ST + 0.80" OD 31 1.. 58-110 04/88 HTS-ST + 2.60" OD 22 1.1 59-63 04/88 HTS-SF + 1.10" OD 28 0.A 60-60 04/88 HTS-SF + 0.60" OD 28 0.. 60-64 04/88 HTS-SF + 1.00" OD 32 0, 62-42 04/88 CTS-SF + 1.00" OD 37 0. 62-100 04/88 HTS-SF + 0.90" OD 35 O. 62-102 04/88 HTS-SF + 1.10" OD 31

1. o.

62-104 04/88 HTS-SF + 1.20" OD 26 1.o l

-y 2 Plant:1CALVERT CLIFFS-UNIT: 1; ' Stoca1Gonoratort'12 - -Outogos-04/88c k OD,20-39 % TW,ALL VOLTS,ALL ELEY.(ALL TUBES),ALL-RL -QUERY: 'i, .'1 ROW-LINEL OUTAGE ELEVATION INDICATION t TW YOLTS - t 63-57- 04/88 C4- +' 6.70" OD' 37 0.73 '64-64 04/88 HTS-SF + 1.70" OD' 34

0.50 66-/ '68 04/88

. HTS-SF, + '2.10" OD 24 0.92' 66-100 04/88 HTS-SF +- 1.40" OD' 21 'O.77 97 04/88 HTS-SF + O. 8 0 "- OD 31 0.65' 68-'x70 04/88 HTS-SF + 0.50" OD 28 0.65 68-74 04/88. HTS-SF -+ 0.80" OD 29 0.44. 04/88 ' HTS-SF +- 1.20" OD 38 0.53' 68-94 04/88 HTS-SF + 0.70" OD 35 J 1. 35 ' 68-108- 04/88 CTS-SF . +.10.20" OD 27: 0.46 68-128.04/88-C4 + 30.50" OD-29-

0. 8 8 '

69 - 61 04/88' DH- + 23.30" OD: 23-0.62 69-' 95 04/88 H5 +.33.10" lOD-34 1.05'

69-99 04/88-HTS-SF'

+ 3.00" OD 26 0.99' 70-70 04/88 HTS-SF + 1.10" OD 25 00.42 70-78 04/88 HTS-SF + ' O.80"' OD 35 0.62 70. 92 04/88 HTS-SF + 1.10" OD 33 0.54 70-94 04/88 HTS-SF + 2.60" OD 28 0.42 '70-100 04/88 HTS-SF + 1.50" .OD 32-0.69 70- 102 04/88 HTS-SF . + 1.60" OD 39 0.61 70.150 04/88 .. C 3.. +.22.70" OD. 38 0.52 1.30" OD 31 0.44 71-79 04/88 HTS-SF +. 0.90" OD 39 0.40' 72-78 04/88: HTS-SF + 90 04/88 HTS-SF + 1.20" OD 32 ' O.43 +- 0.80"' OD- -24 - 1.13 73- '.89 04/88 HTS-SF ' + 0.50" OD 36 1.21 73-97 04/88 ' HTS-SF 04/88' HTS-SF + 1.70" OD 39 0.85' 2 73-99 04/88 HTS-SF + 1.10" OD 26 1.03 74-76 04/88. HTS-SF- + 0.60" OD 36 1.38 74-86 04/88 HTS-SF + 1.40" OD 38 1.42 74-

92. 04/88 HTS-SF

+ 1.70" OD 21 0.76

74-94 04/88 HTS-SF

+ 1.10" OD 28' O.72 04/88 HTS-SF + 1.40" OD 33 - 0.80-75-87 04/88 HTS-SF + 1.40" OD 38-0.67 ~75-89 04/88- -HTS-SF + 1.90" OD 31 ' 0.41 76-- 86 04/88 HTS-SF + 3.00" OD 29 0.48 76-90 04/88 HTS-SF + 1.50" .OD 28-1.91 04/88 HTS-SF + 3.00" OD 34 0.58 76-92 04/88 HTS-SF + 1.60" OD 33' 1.34 77-81 04/88 HTS-SF + 1.60" OD 23 1.02 77-87 04/88 HTS-SF + 1.70" OD 28 0.55 04/88 HTS-SF + 3.00" OD 28 0.80 77-69 04/88 HTS-SF +- 1.70" OD 33 0.90 04/88 HTS-SF + 2.70" OD 32 0.46 04/88 HTS-SF + 3.20" OD .25-0.99: 78-80 04/88 C5 + 26.00" OD 28 0.79 ~78-86 04/88 HTS-SF + 1.60" OD 31 0.80 04/88 HTS-SF + 2.60" OD 39 1.02 78-88 04/88 HTS-SF + 6.10" OD 22 0.49 78-90 04/88 HTS-SF + 0.70" OD 25 0.45 78-94 04/88 HTS-SF + 0.80" OD 36 0.93 78-120 04/88' H2 + 17.80" OD 37 0.51 79-53 04/88 C4 + 25.50" OD 31 0.50 79-57 04/88 C5 + 22.50" OD 36 0.68 79-79 04/88 C2 + 16.20" OD 36 0.62 79-81 04/88 HTS-SF + 0.50" OD 38 0.55 79. 83 04/88 HTS-SF + 2.40" OD 22 0.87 79-91 04/88 HTS-SF + 0.70" OD 35' - 0.44 81-85 04/88 HTS-SF + 0.40" OD 31 1.43 81-87 04/88 HTS-SF + 0.90" OD 21 0.51 04/88 HTS-SF + 1.90" OD 26 0.78 81-93 04/88 HTS-SF + 0.40" OD 25 0.75 83-19 04/88 H6 + 22.00" OD 38 1.09 83-83 04/88 HTS-SF + 0.70" OD 27 1.28 g 83-91 04/88 H7 + 13.20" OD 35 0.54 O

Plant CALVERT CLIFFS UNIT 1 Stoen Gonorator 12 Outogo 04/88 QUERY: OD,20-39 % TW,ALL VOLTS,ALL ELEY (ALL TUBES),ALL-RL - (~~. . k,/ ROW-LINE OUTAGE ELEVATION INDICATION % TW VOLT! 84-74 04/88 .VH + 19.40" OD 24 0. 64 84-80 04/88 H3 + 34.60" OD 35

0. 52 4

0.7 85-' 21 04/88 H5 + 10.80" OD 38 87-63 04/88 H7 + 13.80" OD 22

0. 6h 90-62 04/88

-C4 + 24.30" OD 23 0. 65 93-81 04/88 C5 + 8.10" OD 31 0.5' 0.7f 95-61 04/88 H7 + 9.90" OD 33 '96-34 04/88 C7 + 1.40" OD 25 0.8 97-73 04/88 VM + 21.40" OD 24

0. 61 100-40 04/88 C5

+. 1.50" OD 38

0. 8(

100-- 90 04/88 H3 + 29.40" OD 35

0. 8(

104-88 04/88 YM OD 21

0. 5(

106-68 04/88 H5 + 22.10" OD 33 0. 56 - 110- 106 04/88 H7 + 17.20" OD 31

0. 5j 125-69.

04/88 VC + 9.50" OD 21

2. 4 :

134-108 04/88 CTS-SF + 0.80" OD 23

0. 4 <

137-97 04/88 C10 + 11.20" OD 22

0. 8f TOTAL TUBES: 136 i

f O

I STEAM GENERATOR 12 D. List with Plot of >39% Indications r s lO r l i 9 O

{ iau -->. ! E. 3. 3. g n e g g a a a a e e s e a a e e a a a a a a = t ~=l g ,_').. ,[,-- anm a l I .<s, .-'b D -.i gg =#8 E-5- ' l qg a Q E$ N j g -=i-ers --)o 4ss 2 g ~0fl l.. ,r t est = i { a f'-- I. I y I I l f l o I - se / yg g I n/ 5 y = gl %./ y m g i g ~" l ~~ A (_j e ..e s O J - se. I N - es w = = H -= E -= E a g g a 3 ~5 E a E 58 g I I tlW. ,_si I E r 25 e\\ um ned asise sees 'er Assi amidd e t tan esa e,veu Esse C

,ng. , y. iPlant: 'CALVERT CLIFFS ~ UNIT1 -Steam;Generater: 10~ Outage: 04/88 OUERY: OD,'?39 M.TW,ALLiVOLTS,ALL ELEV (ALL-TUEES),ALL-EL 7 / LROW-LINE OUTAGE' ELEVATION !NDICATION t TW VOLTS' 2 y; ' 45 :04/88 CTS-SF- + 0.E0"- OD-49 0.46-31-. 41 04/86 HTS-SF- + 0 70" OD' .47 'O.64 O '. 7 0 " -

OD-

-42' O.89 32-40 04/88 HTS-SF: + + 0.70" OD. 42' -1.06 61-65: 04/88-HTS-ST 61.-105 04/88 HTS-SF + 1.00" .OD. -49 0.52 70 04/88 HTS-SF + 0. 7 0 " '. 'OD 45 'O.46 '71-97 ~04/88 HTS-SF-0.70"- OD 64 0.62~ 70-96 04/88-HTS-SF. + '73-93 04/88 HTS-SF . +- 0.50" OD 47' O.94 +' 'O.70" 'OD 54 0.65: 74. 96 04/88 HTS-SF- +- 0. 6 0 OD 145 3.06' 75-95 04/88-HTS-SF_ -+ 0.70" OD 67 0.82-76-92 04/88. HTS-SF + .O.60" OD-53 0.53: 77-85 04/88 . HTS-SF + ~ 2.70" OD 52 0.48 77-89- 04/88 HTS-SF- + 2.20" 'OD 43 0.67 78- :86 04/88 HTS-SF +. .0.60" 'OD 44-1.22

78--

90, 04/88 HTS-SF. + 1.30" OD. 47. -1.14 : 94-: 66 i04/88 VM OD. 5 6 -; 0.79 TOTALLTUBES: 17 l' f N. 1 b t' I i l f (' l \\

O 4 l l l i STEAM GENERATOR 12 E. List with Plot of Distorted Indications O O

i,i ! . e

  • a.

- " n"""s " - = $.s e 6 0 8 0 5 0 5 6 3 3 2 2 1 1 0 0 1 1 1 1 1 1 1 1 S_ - - - - - - - - _ _ - - - - - - - - - - s- ) ,E1 s i- , /,

4'y 9

1 5 3 8 1 D EN 7 G IS S S A E B: S U) EB Tf U E ( T G LS AY L A TA T k A T OT O TS T U O 8 o 8/ '= 4 '= S s N O I T ] (0 h AC 2 N .u O 1 I I T D A .a C N R I s e I O t E .a S 37) T I A D E D R L O m r,4% E E P S N I I T E T L R G UM .n O TS .e s I D .a F .a O T .a O L .a P .e 2 1 .a 1 G T S I .a N .A U .a SF F I .a LC8 )3 8 1 T/ .a ( f R4 e e E0 p V I L D A C TR .a O \\ T

E S

TG I NA D M./' LU AT PO D r sr g ! g ige p E gin -()i l

_.....c. P i e r. t : CALVERT CLIFTE UNIT 1 S t e t r-GETCitt07: 1 Outage: C4/8f OUERY: DISTORTD,ALL ELEV (ALL TUPES;,ALL EL g POW-LINF OUTAGE FLEVATION INr..7A77eg 1.30" DISTORTED IN:: 9-109 04/88 PTS-ST + 29.90" DISTORTED I? D 3D-128 04/85 ' HTS-SP + 6.50" DISTORTED IND 48-32 04/86 DH + 21.40" DISTORTED IND 55-49 04/88 C7 + 59-109 04/88 HTS-SF + 2.40" DISTORTED IND 65-63 04/88 HTS-SF + 1.40" DISTORTED IND 73-99 04/88 HTS-SF + 0.60" DISTORTED IND 74-92 04/88 HTS-SF + 0.50" DISTORTED IND 83-19 04/88 H7 + 3.60" DISTORTED IND 85-65 04/88 VC DISTORTED IND 96-52 04/88 C5 + 13.30" DISTORTED IND 97-41 04/88 C5 + 2.40" DISTORTED IND 98-112 04/88 HTS-SF + 23.30" DISTORTED IND TOTAL TUBES: 13 o 'd / \\ l' / v'

.f h 9 STEAM GENERATOR 12 F. Lists with Plots of Tubes not Rolled O O

j' I <-- s, -> t l 3.maagggggsaaaeeseaaeeaaaae i ~48f g g h .1 ' _T ATM AE

\\;!,'<

j I ! {a} ,.c r-g j e i j i i E Q l ) est l g b =&T "5 j a Ia-l l ~** ,( an i 3< d em E i i l 4 I 48 m y' i I = i m i.'jiii j i j .m .c li-' ' H l-l' l t i .r j j a f I,ai i I s -l,,j Ll .ij o I I I i, l-l 4 i i-i u. y. .= .=

i. j Ii i

I sp,_a, 4:. >. ,- a - i n a .i + i t v) t w s!,,=II:ii:_ i : - iI _m. a a l: i I i 8 .I i I: -u a pI I* i' 't l i .u s e i i I .i -( j l

i.

s.. = m I l t e .O i I 3 s l 1 8 ,j l i M -u g .g E in i i l En I 9 5, I u g i E g8 g a <3 l e \\n} d8 ~ e v DLLI 18411 m b se Iff. 45. 81 *05 Aces Asp 1.bf 0's *WA

Plant: CALVERT CLIFTS UNIT'1 S t e a n, G e r.e r n t e r : If Outcge: 04/88 Tubes NOT POLLCD at HOT Tubeeheet , -[,. ROW LINE l () 55 107 ~ 80 E4 81 79 88 22 88 24 88 28 88 32 88 48 88 50 88 52 88 54 88 92 97 71 98 56 98 58 98 60 98 62 98 64 98 66 98 70 98 72 98 74 98 76 98 78 9 *, 80 98 82 98 84 98 86 98 92 98 94 101 27 107 71 108 70 108 72 ,r's 108 74 "N. -) i 108 78 108 80 108 82 108 84 108 86 108 88 108 90 108 92 108 94 108 96 108 98 118 72 118 74 118 76 118 78 118 80 118 82 118 84 118 86 118 88 118 90 118 92 120 42 ,e t

r u,, 3 ............... m..... n. m....... Plant: CALVERT CLIFFE UNIT l' Stest G e r.e r a t o r : 12 ) Outage: 04/88 t Tubes NOT ROLLED at HOT Tuberheet [] ROW LINE 128 72 128 '74 128 76 128-78 128 80 63 Outage : 04/88 . Total = I i V i l l-l l b i 1 1 1

a1 l! = s' 7' g ! s. s ,g , s g g nn..e e 3. 6 e 3, s e s. g 0 . a. 3 g, a g ~ a 3. 2 a 3 i o e s. o p s. g s_ g g g 1 t. ~ V. g fi c m 9 e 1 .f. 5 8 8 a e w E . e D a P 7 8 IS S ] SE A B: S U) E S T (3 ,U LS l q n AY LA T TA OT O TS T 4 t e e e h s L_ uc e b u T ll.I,A ,__L s _.f.!' D = L = O 2 1 C {l t Y z s R .i A a O A a ...,2 T a s - UD f R e u s E E D N L L E O c L G C r' - O R s. T N . q_ O s. a s a= e b a= .i u T g 6 s.. 1 s.. T I N g U i S F s.. F m IL C8 )5 J s. f 9 w T/ 8 R4 5 g u E0 / V 4 = 0 L c g A C e g s. o E t T: G u ~ NA O l - C' _. _. g AT = _ s. LU e, PO 8 ,l ,,,g ,E, e ,N EgiE r; i

.u_... -,o, Plant: CALVERT CLITFS UNIT 1 Steam G e n e r a *' c r *- 1^ Outage: 04/86 Tubes NOT ROLLED at COLD Tuberheet I ROW L'I N T 28 16 83 16 103 3E 130 E3 134 56 134 60 Outage : 04/88 Total = 6 t l l l l e l l l e e 1 ) (' l

A ( STEAM GENERATOR 12 G. Lists with Plots of Sludge Data O l l l )

l l iI1i.'t e ai g i, m., e, ,,,..,s s, a {4.__4_6 ,gg g i G t .7 9 q'. 1 5 0 _.,i I q ( i 8 0 2 R ( E 00 02 M 7 3( S 4-( I J_ 4 S S 2> S A E 4 B: o. EE E L) GO B T (t DD U 7o _ A.. L Ut T LS SE L A AY E TA - = T p G OT O TS 25 T A T y o

i..

U O ( _ p e..___ ._p 8 _. _ _ b. __ _ '= m_c_. s_ e. 8 / 4 ,I L_ ,L_ _. _. s y ~G _q j - m_ E ,jI t q L n ~ T 2 4

4. l T

e_ +. _ O 1 H y ,a m_ t_ E R f( 2 O E=T " [ i_' [ m _, f. ,a 1 T 14 9 o_~ A R

==c- ,a m_ o_ G E EE r _.. . _ L. _ N OO n S E CD . _. _4_ 4 LL G EE m.i. _. _. 7_ L 4I. _. _ _ ,,q ,n l o N . _. f_ l =

  • I 14

,e . J_l_ _. m_ i_ a. v._____af_.. T iIg H ,a _ _ yl t_{ 4. +} G _ i. I o. m_ E I H ,_ _ ml _ n_ _.4_ o

o. )

E G D UL .v S .e i T .a I i E I S 4g, .a E F m T F .a I L o C8 r r 8 l T/ el a .a dec r R4 (t1 E0 ( A 1 V <3n ,s L A E C EEn _. _l._ s s9r u i u, l_M E o s r. T: G sK i_ {I t NA AT =- 9 LU PO 03, l i ,tl ,,,g igIga ,a *g E g,. .[ lIl 7I j ,j, I l

-n ' Plant CALVERT. CLIFFS UNIT 1 Sten-G e r.e r a t o r : 12 Outage: 04/88 f OUERY: SLUDGE,ALL INCHES, HTS-SF (ALL TUBES),ALL-RL h( )_ ROW-LINE ' OUTAGE ELFVATION INDICAT!ON INCHES 10-30 04/86 HTS-SF SLUDGE-1 10-40 04/88-HTS-SF-SLUDGE -0 10-50 04/88 HTS-SF SLUDGE O 10-60 04/88 HTS-SF ' SLUDGE 2 10- 110 04/88 HTS-SF SLUDGE 3 10- 120 04/88 HTS-ST SLUDGE O 10-.130 04/88 HTS-SF SLUDGE I 10- 140 04/88 HTS-SF SLUDGE 2 15-35 04/88 HTS-SF SLUDGE 1 15- '45 04/88 HTS-SF SLUDGE 1 15-55 04/88 HTS-SF SLUDGE 2. 15-105 04/88 HTS-SF SLUDGE 3 15-115 04/88 HTS-SF SLUDGE 1 15-125. 04/88 HTS-SF SLUDGE 1 20- ' 135 04/88 HTS-SF SLUDGE 2 15-30 04/88 HTS-SF SLUDGE 2 20-40 04/88 HTS-SF SLUDGE 2 20-50 04/88 _ HTS-SF SLUDGE 1 20-- 60 04/88 HTS-SF SLUDGE-1 20- 110 04/88 HTS-SF SLUDGE .3 20- 120 04/88 HTS-SF SLUDGE 1 20- 130 04/88 HTS-SF SLUDGE 1 20- 140 04/88 HTS-SF SLUDGE 1 25-35 04/88 HTS-SF SLUDGE 2 25-45 04/88 HTS-SF SLUDGE 2 55 04/88 HTS-SF SLUDGE 2 25-65 04/88 HTS-SF SLUDGE 1 25.105' 04/88 HTS-SF SLUDGE 2 25-115 04/88 HTS-SP SLUDGE 2 25-125 04/88 HTS-SP SLUDGE 1 I 25-135 04/88 HTS-SF SLUDGE 1 30-30 04/88 HTS-SF SLUDGE

1

( 30-40 04/88 HTS-SP SLUDGE 2 L .30-50 04/88 HTS-SP SLUDGE 2 30-60 04/88 HTS-SF SLUDGE 1 30-70 04/88 ' HTS-SF SLUDGE 1 30- 100 04/88 HTS-SF SLUDGE 1 30- 110 04/88 HTS-SF SLUDGE 2 30- 120 04/88 HTS-ST SLUDGE 1 30- 130 04/88 HTS-SF SLUDGE 2 30- 140 04/88 HTS-SF SLUDGE 1 35- .35 04/88 HTS-SF-SLUDGE 1 35- ,45 04/88 HTS-SF SLUDGE 2 35-55 04/88 HTS-ST SLUDGE 3 35-65 04/88 HTS-SF SLUDGE 1 35-75 04/88 HTS-SF SLUDGE 1 35-95 04/88 HTS-SF SLUDGE O 35-105 04/88 HTS-SF SLUDGE 1 35-115 04/88 HTS-SF SLUDGE 3 35-125 04/88 HTS-SF SLUDGE 2 35-135 04/88 HTS-SF SLUDGE l' 40-- 30 04/88 HTS-SF SLUDGE 1 40-40 04/88 HTS-SF SLUDGE 1 40-50 04/88 HTS-SF SLUDGE 3 40-60 04/88 HTS-SF SLUDGE 2 40-70 04/88 HTS-SP SLUDGE 1 40-80 04/88 HTS-SF SLUDGE 1 40-90 04/88 HTS-SF SLUDGE O 40- 100 04/88 HTS-SF SLUDGE 1 40- 110 04/88 HTS-SF SLUDGE 2 40- 120 04/88 HTS-SF SLUDGE 3 40- 130 04/88 HTS-SF SLUDGE 1 40- 140 04/88 HTS-SP SLUDGE 1 f 45-35 04/88 HTS-SF SLUDGE O r 45-45 04/88 HTS-SF SLUDGE 1 l

_. -,. ~. - _- - F1 a'rit.:1CALVERT: CLIFFS UNI! 1 . S t e a m - G e r, e : a t o r : 12 ' ~ .-Outage: 04/68. QUERY: SLUDGE,ALL INCHES, HTS-SF iALL TUPES),ALL-EL .m [ ROW-LINE ' OUTAGE ELEVATTAN INDTCAT!CM ' McHES 55. 04/88 HTS-SF SLUDGE 5 45-65' 04/3R HTS-SF SLUDGE '2 '45-75 04/88 HTS-SF SLUDGE 1 45-85 04/88 HTS-SF SLUDGE 1, 45. 95 04/88 HTS-SF SLUDGE 1 45-105 04/88 HTS-SP SLUDGE 1 45-115 04/88 HTS-SF SLUDGE 5 45-125 04/88 HTS-SP SLUDGE 1-l 45-135 04/88 HTS-SF SLUDGE 1 50-30 04/88' HTS-SF SLUDGE 1 50-70.04/88-HTS-SF -SLUDGE 1: 50-80 04/88 HTS-SF SLUDGE 'l .i 50-90' 04/88 HTS-SF SLUDGE 1 50- 100 04/88 ' HTS-SF SLUDGE 1~ i 50- 110 04/88 HTS-SF SLUDGE 4 50- 120- 04/88 HTS-SF SLUDGE 2 -l 50 130 04/88 HTS-SF SLUDGE 1 50- 140 04/88' HTS-SF SLUDGE 11 55-35 04/88 HTS-SF SLUDGE 1 55-45 04/88 HTS-ST SLUDGE 0 55 - 55 04/89. HTS-SF SLUDGE 3 55-65 04/88 HTS-SF SLUDGE 4 55-75 04/88 HTS-SF SLUDGE 2 l 55-85 04/88 HTS-SF SLUDGE J' ( 55-95 04/88 HTS-SF SLUDGE 2' 55-'105 04/88 HTS-ST SLUDGE 3 55-115 04/88 HTS-SF SLUDGE 2 1 55-125 04/88 HTS-SF SLUDGE' ] 55-135 04/88 HTS-SF SLUDGE 1 60-30 04/88 HTS-SF SLUDGE O l 60-40-04/88 HTS-ST SLUDGE 1-l 60 : 50 04/88 HTS-SP SLUDGE 1 1 '( 60-60 04/88 HTS-SF LSLUDGE 3 l .60- '7 0 04/88 HTS-SF SLUDGE 3 60-80- 04/88 HTS-SF SLUDGE 2 .60-90 04/88 HTS-SF SLUDGE-2' 60- 100 04/88 HTS-SF SLUDGE 4 60- 110 04/88 HTS-SF SLUDGE 3 60- 120 04/88 HTS-SF SLUDGE 1 1 60- 130 04/88 HTS-SF' SLUDGE I i .60-140 04/88 HTS-SF SLUDGE O 65-35 04/88 HTS-SF SLUDGE O-65-45 04/88 HTS-SF SLUDGE 1 65-55 04/88 HTS-SF SLUDGE O 65-65 04/88 _ HTS-SF SLUDGE 3 65-75 04/88 HTS-SF SLUDGE 4 65-85 04/88 HTS-SF SLUDGE 3 65-95 04/88 HTS-SF SLUDGE 4 65-105 04/88 HTS-SP SLUDGE 3 65-115 04/88 HTS-SF SLUDGE 1 65-125 04/88 HTS-SF SLUDGE 1 65-135 04/88 HTS-SF SLUDGE 1 70-30 04/88 HTS-SF SLUDGE O 70-40 04/88 HTS-SP SLUDGE 1 70-50 04/88 HTS-SF SLUDGE 'O 70-60 04/88 HTS-SP SLUDGE 1 70-70 04/88 HTS-SF SLUDGE 3 70-80 04/88 HTS-SF SLUDGE 5 70-90 04/88 HTS-SF SLUDGE 5 70- 100 04/88 HTS-SF SLUDGE 4 70- 110 04/88 HTS-SP SLUDGE 1 E 70- 120 04/88 HTS-SF SLUDGE I 70- 130 04/88 HTS-SF SLUDGE I 70- 140 04/88 HTS-SP SLUDGE O 75-35 04/88 HTS-ST SLUDGE O f I O 1

Plant: CALVERT CLIFFS UNIT 1 - S t e n :n G e r.e r a t e r : 12 ' Outage: 04/88-t .{ OUERY: SLUDGE, AL'L-INCHES, HTS-SP ~ t ALL. TUBES),' ALL-EL. 6 [

(

. ROW-LINE OUTAGE EL EV A T I M[ ' INDICATION THCHES 75 '.45 04/88 HTS-SF SLUDGE 1-754 55-04/88 HTS-ST SLUDGE. C-65 04/88 HTS-SF SLUDGE-1. 75 04/88. . HTS-SF SLUDGE 3' 75-t =75-83 04/88 HTS-SF SLUDGE 5 75-95,'04/88 HTS-SP SLUDGE 4 75-105 04/88 HTS-SF SLUDGE 1 75-115 04/88 HTS-SF SLUDGE 1-75-125 04/88 HTS-SP SLUDGE' l' '75-135 04/88 HTS-SF SLUDGE D 80-30 04/88 HTS-ST SLUDGE O 80-~ 40' 04/88 HTS-SF SLUDGE 1 80-50 04/88 HTS-SF SLUDGE 1 80-60 04/88 HTS-SF SLUDGE O 80-70 04/88' HTS-SF SLUDGE 1 80-80 04/88 HTS-SF SLUDGE 3 80-90 04/88 HTS-SF SLUDGE 4' 80- 100 04/88 HTS-SF SLUDGE 1 80- 110 04/88 HTS-SP SLUDGE O 80- 120 04/88 HTS-SF SLUDGE 2 80- 130 04/88 HTS-SF SLUDGE 1 80- 140 04/88 . HTS-ST SLUDGE O 35 04/88 HTS-SF SLUDGE O 85-45-04/88 HTS-ST SLUDGE O 85-55 04/88 HTS-SF SLUDGE 1 85-65 04/88 HTS-SP SLUDGE 1 85-75 04/88 HTS-SF SLUDGE 1 85-85 04/88, HTS-SP SLUDGE 3 85-95 04/88 HTS-SF SLUDGE 2 105 04/88 HTS-SF SLUDGE' I 85-115 04/88 HTS-SF SLUDGE 1 85-125 04/88 HTS-SF SLUDGE-2 f-85-135 04/88 HTS-SP SLUDGE O g' 90-30 04/88' HTS-SF SLUDGE O 90-40 04/88 HTS-SF SLUDGE O 90-50 04/88 HTS-SF-SLUDGE 2 90-60 04/88 HTS-SP SLUDGE 1 90-70 04/88-HTS-SF SLUDGE 1 90-80- 04/88 MTS-SF SLUDGE 1 90-90 04/88 HTS-SF SLUDGE '2 90- 100. 04/88 HTS-SF SLUDGE-2 90- 110- 04/88 HTS-SF-SLUDGE 1 90- 120 04/88 HTS-SF SLUDGE-1 90- 130 04/88 HTS-SF SLUDGE O 90- 140 04/88 HTS-SF SLUDGE O 95-35 04/88 HTS-EF SLUDGE O 95-45 '04/88 HTS-SF SLUDGE O 95-55 04/88 HTS-SF SLUDGE 1 2 95-65 04/88 HTS-SP SLUDGE 95-75 04/88 HTS-ST SLUDGE 1 95-85 04/88 HTS-SF SLUDGE 1 95-95 04/88 HTS-SF SLUDGE 1 95-105 04/88 HTS-SF SLUDGE 1 '95-115 04/88 HTS-SP SLUDGE 1 95-125 04/88 HTS-SF SLUDGE O 95-135 04/88 HTS-SF SLUDGE D 100-30 04/88 HTS-SF SLUDGE-0 100-40 04/88 HTS-SF SLUDGE 0 100-50 04/88 HTS-SF SLUDGE O 100-60 04/88 HTS-SF SLUDGE 2 100-70 04/88 HTS-SF SLUDGE 1 100-80 04/88 HTS-SF SLUDGE I 100-90 04/88 HTS-SF SLUDGE 2 100- 100- 04/88 HTS-SF SLUDGE 2 f 100- 110 04/88 HTS-SF SLUDGE 1 N.

l a ri CALVERT CLIFFS. UNI L; . Outage: 04/88. ' 1 Stear, G +.e o 4 OUERY: SLUDGE,ALL INCHES, HTS-SF (ALL TUEES1,ALL'-EL' 1 g ROW-LINE~ Of f T AGE FLEVATION IND7 CATION. Nbyrs' ....'100 120 04/88' HTS-SF SLUDGE O ~ i, 100- 130 04/88 HTS-SF SLUDGE 0- -100- 140: 04/88-HTS-SP SLUDGE O 105- .35 04/88 HTS-SF SLUDGE O 105-45 ,105-55 ~ 04/88-HTS-SF SLUDGE 0' 04/88 HTS-SF SLUDGE' O 105-65 04/88 HTS-SF' SLUDGE. 2 l .105-75 '04/88 HTS-SF. SLUDGE-O' 105-- 85 04/88 HTS-SF -SLUDGE ~2. 105-95 04/88 HTS-SP SLUDGE 1-105-105 04/88. HTS-SF SLUDGE 1 105-115 04/88 HTS-SP SLUDGE D' 105-125 04/88 HTS-SF SLUDGE 0~ 105-135 04/88 HTS-SF SLUDGE O TOTAL TUBES: 209 i. s e 4 GV 4

1l1lll ll o j!j;;l! l j ) I ,,g ,,..,, m,g ..= .,,,.,,y . ms., e,.,. s g s g g s.. s_ _. _ n_.. _ _ _. _ _ _.. _ _. _ _ _ _ _ _ _- s , i/ M (t1% j;af_; L. L i 9 _. L. l-7 9 2 1 t._ 1 5 0 8 1 2 R em E P 7 i E t I 4 S S a> S _q4 A E 8; s , L. ss e E U) e TW mc t ( Y LS u AY =s l. E TA T A G OT O -r TS a T A T p._u_. U O I i 8 _ m. p.. 8 / 1l 4 . L_ m_4 G ,.f E 1 gI l- . ; ['. __4 L iq l 1 4 b_ D 2 u l_. 1 L O e ~a m rm Y: t C i R _3_go_ 7 A: ~ O s. i { N 2 T 4 e .i s~. /. f A 1 R es q_, E es ia M'. 4._4. a4l}__q _._ ~ s N . ft s G E T: S G mm a e r_l . 4. [_ __ 4j N s4 I pi !l;

4

(

  1. _ i

} . LL. T H m_ 4 ,}. G e I a. r y, E d 9_j,!_ H 1. 6- .L E ~ D t. G 4 U g L 1 S 1 i T I N g 3 U M 3 9 4-F 0

i I

l 1 F N L p 4 t C8 I T 8 m A T/ 4 C 4 R4 rm2 M E0 74 u V a<a2 L 4 A E C L rep esI 6_ m s T. I NA ssM M E

TG uuu l

6 AT N LU 6 (ti PD ose l ; j:. , gs l g I je ,1 ,I E g E l! !tll,

N W. W uVWu -wwe a qvv- ' Plant: CALVERT CLIFFS. UNIT 1: Steam Generator: 12 Outage: 04/88 QUERY: SLUDGE,ALL INCHES, CTS-SF (ALL TUPES),ALL-EL

,. e.

{ V . ROW-LINE O'UTAGE ELFVATION INDICAT!ON~ IMCHES 10-- 30 '04/88 CTS-SF SLUDGE 1 10 - 40 04/88 -CTS-SF SLUDGE 1 10-50 04/88 CTS-SF = SLUDGE O 10-60 04/88 . CTS-ST SLUDGE 3 10- 110 04/88 CTS-SF SLUDGE 4 10- 120- 04/88 CTS-SF-SLUDGE l-10-'130 04/88 CTS-SF SLUDGE 2 10- 140 04/88 CTS-SF-SLUDGE 2 15-35 04/88 CTS-SP SLUDGE 2 15-45.04/88 CTS-ST ' SLUDGE 2 15-55 04/88 CTS-ST SLUDGE 2 15-105 04/88 CTS-SF SLUDGE 1 15-115 04/88 CTS-SF SLUDGE 3 15-125 04/88 CTS-SF SLUDGE 2 15-135 04/88 CTS-ST SLUDGE 2 20-30 04/88 CTS-SF SLUDGE 1 20-- 40 04/88 CTS-SP SLUDGE' 2 50 04/88 CTS-SF SLUDGE 1 20-- 60 04/88 CTS-SF' SLUDGE 3 20- 110 04/88 CTS-SF SLUDGE 3 120 04/88 CIS-ST SLUDGE 2 20- 130- 04/88 CTS-ST SLUDGE 1 20- 140 04/88 CTS-SF SLUDGE 1 25- :35 04/88 CTS-SF SLUDGE 1 25-45 04/88 CTS-SF SLUDGE I 25-55 04/88 CTS-SF SLUDGE 1 25-65 04/88 CTS-SF SLUDGE 2 25-105 04/88 CTS-SP SLUDGE 3 25-115 04/88 CTS-SF SLUDGE 1 ) 25-125 04/88 CTS-SF SLUDGE 1 j 25-135 04/88 CTS-SF SLUDGE 1 A 30-30 04/88 CTS-SF- -SLUDGE 1 .,f g ~ () - 30-40 04/88 CTS-SF SLUDGE 1 30-50 04/88 CTS-SF SLUDGE 1 i 30-60 04/88 CTS-SF SLUDGE 1 30-70 04/88 CTS-ST SLUDGE 2-r 30- 100 04/88 CTS-ST SLUDGE 2 30- 110 04/88 CTS-SF SLUDGE 1 30- 120 04/88 CTS-SF SLUDGE 1 { 30- 130 04/88 CTS-SF SLUDGE 1 l c 30- 140 04/88 CTS-SF SLUDGE 1 f 35-35 04/08 CTS-SF SLUDGE 1 } 35-45 04/88 CTS-SF SLUDGE 1 35-55 04/88 CTS-SP SLUDGE 1 I s 35-65 04/88 CTS-SF SLUDGE 1 ^ I 35-75 04/88 . CTS-SF SLUDGE 4 1 9 35-95 04/88 CTS-SF SLUDGE 2 l 35-105 04/88 CTS-SF SLUDGE 1 I b 1 (' 35-115 04/88 CTS-SF SLUDGE 35-125 04/88 CTS-SF SLUDGE 1 35-135 04/88 CTS-SF SLUDGE 1 40-30 04/88 CTS-SF SLUDGE 1 1 40-40 04/88 CTS-SF SLUDGE 1 p h 40-50 04/88 CTS-SF SLUDGE 1 ) 40-60 04/88 CTS SF SLUDGE 1 40-70 04/88 CTS-SF SLUDGE 1 40-80 04/88 CTS-SF SLUDGE 3 40-90 04/88 CTS-SF SLUDGE 1 40- 100 04/88 CTS-SF SLUDGE 1 i 40- 110 04/88 CTS-SF SLUDGE 1 1 40- 120 04/88 CTS-SF SLUDGE 1 h-40- 130 04/88 CTS-SF SLUDGE 1 F 40- 140 04/88 CTS-SF SLUDGE 1 n 45 - 35 04/88 CTS-SF SLUDGE 1 45-45 04/88 CTS-SF SLUDGE O

V ..i.,,,,. ,,, w w w. s. o...... 16,,i.,, s im... n w w xxe owew < m a n. _. w -~ Plant: 'CALVERT' CLIFFS UNIT 1-iSteam Generator: l' O [ ' Outage: 04/88 1 QUERY: SLUDGE, ALL' INCHES, CTS-SF ( ALL TUBES ), ALL-RL - .n + i-Q ROW-LINE OUTAGE ELEVATION INDICATION INCFES '45-55 04/88 CTS-SP SLUDGE O 45-65 04/88 CTS-ST SLUDGE 1 ~45- '75 04/88 CTS-SP-SLUDGE-1 45-85 04/88 CTS-SF SLUDGE 2 45-95 04/88 CTS-ST SLUDGE 1 45-105- 04/88 CTS-SF SLUDGE' 1 45-115 04/88 CTS-SF SLUDGE 1-L 45-125 04/88 CTS-SF . SLUDGE 1. L 45-135 04/88 CTS-SF SLUDGE 1 50-30 04/88 CTS-SP SLUDGE 1 50-50 04/88 CTS-SF SLUDGE 1-50-70 04/88 CTS-SF SLUDGE 1 50-80 04/88 CTS-SF SLUDGE 1 50-90 04/88 CTS-SF SLUDGE 1 50- 100 04/88 CTS-SF -SLUDGE 1 50- 110- 04/88 CTS-SF SLUDGE 1 50- 120 04/88 CTS-SF SLUDGE- -1 50- 130 04/88 CTS-SF SLUDGE 1 ~50-140 04/88 CTS-SF SLUDGE 1 55-35 04/88 CTS-SF SLUDGE 1 55-45 04/88 CTS-SP SLUDGE 1 55-55 04/88 CTS-SF' SLUDGE 1 55-65 04/88 CTS-SP SLUDGE 1 55-75 04/88 CTS-SF SLUDGE 1 55-85 04/88 CTS-SP SLUDGE 1 55-95 04/88 CTS-SP SLUDGE 1 55-105 04/88 CTS-SF SLUDGE 1-55-115 04/88 CTS-SF SLUDGE l' 55-125 04/88 CTS-SF SLUDGE 1 55-135 04/88 CTS-SF SLUDGE I 60-30 04/88 CTS-SF SLUDGE O O' 60 - 40 04/88 CTS-SP SLUDGE 1 1 60-50- 04/88 CTS-SF SLUDGE 1 \\ 60-60 04/88 CTS-ST SLUDGE 1 60-70 04/88 CTS-SF SLUDGE 1 60-80 04/88 CTS-SF SLUDGE 1 60-90 04/88 CTS-SF SLUDGE 1 60- 100 04/88 CTS-SF SLUDGE 1 60- 110 04/88 CTS-SF' SLUDGE 1 60- 120 04/88 CTS-SF SLUDGE 1 60- 130 04/88 CTS-SF SLUDGE 1 60- 140 04/88 CTS-SF SLUDGE O 65-35 04/88 CTS-SF SLUDGE 1 65-45 04/88 CTS-ST SLUDGE 1 65-55 04/88 CTS-SF SLUDGE 1 65-65 04/88 CTS-SP SLUDGE 1 65-75 04/88 CTS-SF SLUDGE 1 65-85 04/88 CTS-SF SLUDGE 1 65-95 04/88 CTS-SP SLUDGE 1 65-105 04/88 CTS-SF SLUDGE 1 65-115 04/88 CTS-SF SLUDGE 1 65-125 04/88 CTS-SF SLUDGE 1 65-135 04/88 CTS-SF SLUDGE O 70-30 04/88 CTS-SF SLUDGE O 70-40 04/88 CTS-SP SLUDGE 1 70-50 04/88 CTS-SF SLUDGE 1 70-60 04/88 CTS-SF SLUDGE O 70-70 04/88 CTS-SF SLUDGE 1 70-80 04/88 CTS-SF SLUDGE 1 70-90 04/88 CTS-SF SLUDGE O 70- 100 04/88 CTS-SF SLUDGE 1 70- 110 04/88 CTS-SF SLUDGE 1 70- 120 04/88 CTS-SF SLUDGE 1 70- 130 04/88 CTS-ST SLUDGE 1 70- 140 04/88 CTS-SF SLUDGE O lD V

_ - -. m._ ' Plant:' CALVERT CLIFFS UNIT 1 Steam Generator: 10 ' Outage: 04/88 l ._ QUERY: SLUDGE,ALL INCHES, CTS-SF.(ALL, TUBES),ALL-RL ROW-LINE OUTAGE ELEVATION INDICATION- 'INCHEFi 75-135 04/88 CTS-ST SLUDGE 'O 75 - '45-04/88 CTS-SF SLUDGE 1. 75 - 55' 04/88 CTS - SF-SLUDGE' 1 75-65 '04/88 CTS-SF_ SLUDGE' 1 75-75 04/88 CTS-SF SLUDGE 1 1 75-83 04/88 CTS-SF SLUDGE O 75-95 04/88-CTS-SF SLUDGE 1 75-105 04/88 CTS-SF. SLUDGE-1 75-115 04/88 . CTS-SF SLUDGE 1 75 125 04/88 CTS-SF SLUDGE 1 75-135 04/88 CTS-SF SLUDGE O 80-30-04/88 CTS-SF SLUDGE 0-80-- -40 04/88 CTS-SF SLUDGE OL 80-50 04/88' CTS-SF SLUDGE 1 80 - 60 04/88 CTS-SF SLUDGE 1 80-70 04/88 CTS-SF SLUDGE 1 80-80 04/88 CTS-SF-SLUDGE 1 80- -90 04/88 CTS-SF SLUDGE. 80- 100 04/88 CTS-SF SLUDSE 1 80- 110 04/88 . CTS-ST SLUDGE 1: 80- '120 04/88 CTS-ST SLUDGE 1 80- 130 04/88 CTS-SF SLUDGE O 80 140 04/88 CTS-SF SLUDGE O 85-35 04/88 CTS-SP SLUDGE O 85- '45 04/88 CTS-SF SLUDGF .1, 85-55-04/88 CTS-SF SLUDGE 1 85-65 04/88 CTS-ST SLUDGE 1 '85-75 04/88 CTS-SF SLUDGE 1 85-85 04/88 CTS-SP SLUDGE 1 85-95 04/88 CTS-SF SLUDGE 1 85 105 04/88-CTS-SF SLUDGE 1 85-115 04/88 CTS-SF SLUDGE l' t 85-125 04/88 CTS-SF SLUDGE O k. 85-135 04/88 CTS-SF SLUDGE O 90-30 04/88 CTS-ST SLUDGE 0 90-40 04/88 CTS-SF-SLUDGE O 90-50 04/88-CTS-SP SLUDGE 1 90-60 04/88 CTS-SF. SLUDGE 1 '90-70~.04/88 CTS-SP SLUDGE 1 90-80 04/88 CTS-SF SLUDGE 1 90-- 90 04/88 CTS-SF SLUDGE 1 90- 100 04/88 CTS-SF SLUDGE 1 90- 110 04/88 CTS-SF SLUDGE 1 90- 120 04/88 CTS-SF SLUDGE 1 90- 130 04/88 C7S-SF SLUDGE O 90- 1 00 04/88 CTS-SF SLUDGE O 95-35 04/88 CTS-SF SLUDGE O 95-45 04/88 CTS-SF SLUDGE O 95-55 04/88 CTS-SF SLUDGE-1 95-65 04/88 CTS-SF SLUDGE 1 95-75 04/88 CTS-SP SLUDGE 1 95-85 04/88 CTS-SF SLUDGE 1-95-95 04/88 CTS-SF SLUDGE 1 95-105 04/88 CTS-SF SLUDGE 1 95-115 04/88 CTS-SP SLUDGE O 95-125 04/88 CTS-SF SLUDGE O 95-135 04/88 CTS-SF SLUDGE O 100-30 04/88 CTS-SF SLUDGE O 100-40 04/88-CTS-SF SLUDGE O 100-50 04/88 CTS-SF SLUDGE O l 100-60 04/88-CTS-SF SLUDGE 1 i 100-70 04/88 CTS-SF SLUDGE 1 -100-80 04/88 CTS-SF SLUDGE 1 100-90 04/88 CTS-SF SLUDGE 1 '100- 100 04/88 CTS-ST SLUDGE 1

n, P' Plant s - CALVERT' CLIFFS. UNIT _'l = Steam G e r.e : a t o r : :12-- Outage: 04/88 p., 1,(. JOUERY: SLUDGE,ALLiINCHES,' CTS-ST-(ALL TUEES),'ALL-EL lr % M ):: ROW-LINE ? -0UTAGE -ELEVATION-INDICATION T EHES ^: ~ 10 0-- 110- ~ 0 4 '/ 8 8 CTS-SF ' SLUDGE . 'O - l100- 100_. 04/88 CTS-ST SLUDGE O- .100- 130 04/88. CTS-ST SLUDGE O 100-'140 '04/88 CTS-SF' SLUDGE' 0 105- '3504/88 -CTS-SF SLUDGE-0 '. 105-45- 04/88-CTS-SF~ SLUDGE O 105-55 04/88 CTS-ST. SLUDGE- 'O 105-'

65. 04/88 CTS-SF-SLUDGE.

'l 105-- 75 04/88 CTS-SF SLUDGE 1 105-85 04/88 -CTS-SF' SLUDGE 1 .10 5 - - 95 04/88 CTS-SF -SLUDGE -I 105-105= 04/88 CTS-SF SLUDGE 0: ' 105-'115 04/88. ' CTS-SF' . SLUDGE -0 105-125' 04/88 CTS-SF SLUDGE < 0. 105--135 04/88 CTS-SP SLUDGEJ 0 TOTAL TD' @ 210 4 O C(

1 O STEAM GENERATOR 12 H. List of Tubes Dented O S e O

p, -w w ywwv m y. v.~- x 'Plantn CALVERT' CLIFFS UNIT.1 S t e a rt. G e r.e : s t o r : 12 Outage: 04/88 .l QUERY' DENTS,ALL MILS,ALL ELEY (ALL TUEES),ALL-RL e-S %- 1( 4 y/ .--[ R O W - LI N E OUTAGE ELFVATION INDICATION WLTS_ 1-43 04/88 HTS-SF + 3.10" DENT 7 17.00" DENT 11: 04/88 HTS-SF- + 1.113. 04/88 VM DENT 16 2-134 04/88 H5 + 27.60" DENT 11 5- ~145-04/88 H5 + 35.40" -DENT 12 7-119 04/88 C6 + - 4.10" DENT 9 7-129. 04/88 C6 + 5.50" DENT 10 7 143 04/88 C6 + 5.00" DENT 10 H6 + 4.50" DENT' 14 7-'145 04/88 5.60" DENT 14 7-147 04/88 H6 - + 7-149 04/88 H6 + 5.40" DENT 15 9-51 04/88 VM DENT 5 9-56' 04/88 VM- -DENT 12 9-111 04/88 HI + 17.30" DENT 7 9-151 04/88 HI + 17.40" DENT 5 '10 - 2 04/88 H5' + 11.30" DENT 8 10 142 04/88 DH DENT 6 10- 152 04/88 Cl + 28.20" DENT 8 11-31 04/88 VM DENT 7 23.20" DENT 5 'll--121 04/88-C2 + 12-128 04/88 VM DENT 5 12-158 04/88 DC DENT 5 7.70" DENT 7 13-107 04/88' C6 + 13-109 04/88 C6 + 7.70"- DENT S 7.90" DENT 9 13-113 04/68 C6 + 13-123 04/88 .VM DENT. 7 4.40" DENT 6 13-125 04/88 DH + 13-129 04/88 VM DENT 6 04/88 H6 + 7.70" DENT 8 13-137 04/88 VM DENT 6 13 - 139 04/88 VM DENT 6 ,O 13-141 04/88 C6 + 8.10" DENT 8 / 04/88 VM DENT 6 13-143 04/88 VM DENT-5 13-145 04/88 C6 + 8.10" DENT 6 13-147 04/88 C6 + 8.00" DENT-7 13-149 04/88 C6 4 7.90" DENT ? 13-151 04/88 VM DENT 5 13-157 04/88 DC DENT 9 13-161 04/88 H3 +- 5.90" DENT 6 13-165 04/88 VM DENT 5 14-110 04/88 C6 + 8.80" DENT. 10 14-112 04/88 C6 + 8.60" DENT 11 14-164 04/88 HTS-SF + 25.30" DENT 5 14-166 04/88 VM DENT 22 04/88 VM DENT 11 15-145 04/88 HI + 7.50" DENT 8 19-139 04/88 H6 + 2.50" DENT 9 04/88 H6 + 5.20" DENT 7 20- 120 04/88 DC DENT 9 21-39 04/88 VM + 6.80" DENT 6 21-51 04/88 YM + 5.80" DENT 6 21-53 04/88 VM + 5.80" DENT 6 5.60" DENT 7 21-55 04/88 VM + 21-57 04/88 VM + 5.00" DENT 8 25-27 04/88 C6 DENT 6 27-135 04/88 H6 + 18.70" DENT 8 28-124 04/88 VM DENT-5 I 29-49 04/88 VM DENT 6 30-36 04/88 H3 DENT 12 k" 31-57 04/88 VM DENT 5 h 31-143 04/88 CTS-SF + 30.20" DENT 5 32-136 04/88 VM DENT 6 32-156 04/88 VM + 2.40" DENT 13 04/88 VM DENT 12 m I <w

Plant: CALVERT CLIFFS UNIT 1~ ' Steam Generator: 12 Cutage: 04/88 I OUERY: DENTS,ALL MILS,ALL ELEV (ALL TUBESi,ALL-RL. ROW-LINE OUTAGE ELEVATION INDICATION WLTS 33-41 04/88 VM + 9.30". DENT 8. 35-53 04/88 C6 + 13.40" DENT '10 17.60" DENT 9 35-107 04/88 H5 + 3.50" DENT 11 37-- 37 04/88 C6 + 04/88 C6 + 5.10" DENT 8-04/88 C6 + 14.40" DENT 6 37-'103 04/88 H6 + 23.60" DENT 5-04/88 H6 + 24.40" DENT. 6 04/88 H7 DENT 5 04/88 H7 + 0.80" DENT. 5 37-125 04/88-H6 + 14.40"- DENT 6 37-145 04/88 C6 + 17.70" DENT 7 04/08 C6 + 19.00" DENT 11 40- 116 04/88 C7 + 13.60" DENT 5 04/88-C7 + 21.60" DENT 5 41-=107 04/88 HTS-SF + 33.20" DENT 11 41-111 04/88 HTS-SF- + 34.10" DENT 7 04/88 HTS-SF + 34.50" DENT 6 22.70" DENT 12 41-123 04/88-H6 + 04/88 H6 + 21.50" DENT 11 04/88 H6' + 20.10" DENT 7 04/88 H6 + 18.90" DENT 5 42-12 04/88 C6 + 23.50" DENT 5 24.60" DENT 5 04/88-C6 + 25.80" DENT 8 .04/88 C6 + 04/88 C7 DENT 8 42-' 22. 04/88 VM DENT 5 23.80" DENT 6 42-24 04/88 C6 + 25.10" DENT 9 04/88 C6 + 04/88 C7' DENT 11 d 42-44-04/88 VM DENT 6 - (N 43- - 9 04/88 H7 DENT 16 '24.90" DENT 7 ' Q- ' 43-31 04/88 CTS-SF + 44-82-04/88-H6 + 12.30" DENT 16 44-126 04/88 C6 + 21.80" DENT. 8 04/88 C7 DENT ll 04/88 H6 + 12.00" DENT 11 44-138 04/88 Co + 19.00". DENT 7 04/88 C6 + 21.70" DENT 5 04/88 C6 + 23.20" DENT 8 04/88 C7 DENT 5 46-32 04/88 C7 DENT 10 20.10" DENT 6 04/88 H6 + 04/88 H6 + 21.70" DENT-25 48-46 04/88 VM DENT 13 24.20" DENT 6 48-66 04/88 HTS-SF v 51-51 04/88 H6 + 22.60" DENT 6 52-20 04/88 HTS-SF + 5.80" DENT 25 52-34 04/88 CTS-SF + 29.00" DENT 33 52-52 04/88 H6 + 22.70" DENT 7 57-107 04/88 H7 DENT 6 57-133 04/88 VM + 18.90" DENT 8 59-117 04/88 C2 + 32.90" DENT 10 62-142 04/88 VM DENT 16 63.135 04/88 C7 + 28.60" DENT 17 67-19 04/88 C7 + 20.80" DENT 6 04/88 C7 + 19.30" DENT 6 67-21 04/88 H7 + 24.60" DENT 8 04/88 H8 + 0.20" DENT ? 67-27 04/88 H7 + 19.20" DENT 7 04/88 H7 + 20.80" DENT 22 04/88 H7 + 22.10" DENT 12 04/88 DH + 30.40" DENT 6 8.40" DENT 5 04/88 VM + ( 04/88 C7 + 12.80" DENT 7 OV

Plant:.CALVERT CLIFFS UNIT 1 Stear. Generator: 12 ' Outages. 04/88 QUERY: DENTS,ALL MILS,ALL ELEY (ALL TUEES),ALL-RL ,.y -l 'FOW-LINE OUTAGE ELEVATION INDICATION VULTS 04/88 C7- + 14.20" DENT-11 15.60" DENT 13 04/8S C7 + 67-41 04/88 H7 + 23.80" ' DENT 67- .49 04/88 H7 + 10.60" DENT 12 04/88 H7 + 11.20" DENT 6 04/88 H8 + 1.30" DENT 45 67-81 04/88 DH + 13.40" DENT 8 67-97 04/88 H8 DENT 12 67 115 04/88 C7 + 1.40" DENT-5 04/88 C7 +. 8.40" DENT 6' 04/88 CB DENT 6 67-139 04/88 C7 -+ 11.00" -DENT 5 04/88 C7 + 18.00" DENT 6 04/88 C7 +-20.70" DENT 8 67-151 04/88 C7 + 17.10"' DENT 8 04/88 C8 DENT 5 04/88 C8 + 2.60" DENT 9 69-21 04/88-DH + 18.40" DENT 5 21.00" DENT 8 69-31 04/88 H7 + 69-49 04/88 DH + 14.90" DENT B 69-73 04/88 C7 + 18.00" DENT 7 04/88 C7 DENT 8 11.50" DENT 13 69-83 04/88 DH + 21.10" DENT 7 69-85 04/88 C7 + 1.00" DENT 8. 69-87 04/88 C8 + 04/88 C8 DENT 5 69-105 04/88 H5 DENT 7 16.70" DENT 12 69-115 04/88 H7 + 04/88 H8 DENT 23 69-139 04/88 H7 + 11.50" DENT 9 I 70-64 04/88 H7 + 16.70" DENT 13. 13.30" DENT 10 04/88 H7 + 04/88 H6 + 23.90" DENT 5 O 04/88 C8 DENT 6 04/88 C8 DENT 6 18.50" DENT 13 70- 132 04/88 H7 + 3.10" DENT 6 04/88 C7 + 11.80" DENT 7 70- 136 04/88 H7 + 04/88 H7 + 4.10" DENT 5 04/88 HB DENT 12 13.00" DENT 54 04/88 H8 + 04/88 DH + 2.50" DENT 37 04/88 DH + 4.90" DENT 26 04/88 VM DENT 17 71-43 04/88 VM DENT 8 71-105 04/88 C2 DENT 6 13.60" DENT 23 74-80 04/88 C8 + 04/88 C7 + 13.40" DENT 9 l 04/88 C7 + 12.80" DENT 9 1 04/88 C7 +.12.00" DENT 6 04/88 C7 + 11.60" DENT 7 76-18 04/88 VM DENT 7 76-78 04/88 C7 + 20.80" DENT 7 04/88 C7 + 18.40" DENT 6 04/88 C7 + 17.60" DENT 6 77-37 04/88 C7 + 23.20" DENT 7 l 77-93 04/88 H5 + 9.20" DENT 7 04/88 H5 + 9.70" DENT 12 l 78-42 04/88 C7 + 17.20" DENT 5 04/88 C7 + 11.40" DENT 5 04/88 C8 + 2.10" DENT 13 04/88 H7 + 22.00" DENT 7 7 78-136 04/88 H8 + 3.70" DENT 79-135 04/88 CTS-ST + 10.30" DENT 5 1.70" DENT 9 g 79-139 04/88 C8 + \\

,Plcnt: CALVERT CLIFFS UNIT 1 S t e c t. Generater: 12 " Outage: 04/88. 'OUERY': DENTS,ALL MILS,ALL ELEV.(ALL TUEES),ALL-RL p. ) ROW-LINE OUTAGE ELEVATION INDICATION Vol!1S 81-' 81 04/88-HTS-SF DENT 20 29.30" DENT-6 04/88 C2 + 81-131 04/88 C8 + 6.90" DENT 5 82-32 04/88 H7 + 13.60" DENT 9 04/88 H7 l+ 15.50" DENT 14' 04/88 H7 + 22.90" DENT-13 04/88 C7 + 16.70" DENT 6 82. 88 04/88' 'H1 + 1.50" DENT-6 82-114 04/88 H4 + 34.30"- DENT-5 85.123 04/88-C8 + 18.10" DENT 10 86-84 04/88 VH .+ 18.90" DENT 10 04/88 C8 DENT 6' 86-98 04/88 H5 + 6.40" DENT. 6 86-132 04/88 C4 + 21.50" DENT 12 86-136 04/88 C8' + 1.80" DENT 7 86-' 138 04/88 Hb + 5.80" DENT. 7 86-140 04/88 HS + 3.70" DENT 11 86-146~ 04/88 H5 + 36.80" DENT 9 87-125 04/88 VH + 10.80" DENT 10 87-131 04/88 VM + 25.40" DENT 6 90-30 04/88 Cl + 29.70" DENT 12 90-66 04/88 VM-DENT 5. 90- 108 04/88 H9 DENT 51 91- -37 04/88 H9 DENT 57 91-39 04/88 H9 DENT 50 91 - 41 04/88 H9 DENT 89 91-43 04/88 H9 DENT 20 04/08-C8 + 15.90" DENT 7 91-47 04/88 H9 DENT 41 91-51 04/88 HS + 14.80" ' DENT 6 91- .53 04/88 H9 DENT 32 91-55 04/88 H9 DENT 8' p f i 91-57 04/88 H9 DENT 8 \\j 91-59 04/88 H9 DENT 60-91-- 63- 04/88 H9 + 2.40" DENT 6 91-67 04/88. H9 DENT 41 04/88 H9 DENT 41 91-69 04/88 H9 DENT 46 2.00" DENT 10 04/88 C9 + 91-73 04/88 C9 DENT 6 04/88_ H9 DENT 17 91. 77 04/88 H9 DENT 46 04/88 C9 DENT-13 91-85 04/88 H9 DENT 29 91-87 04/88 H9 DENT 95 91-89 04/88 H9 DENT 59 91-93 04/88 H9 DENT 31 91-95 04/88 H9 DENT 93 78 91-97 04/88 H9 DENT 4 04/88 C9 DENT 17 l 91-99 04/88 H9 DENT 36 91-105 04/88 H9 DENT 90 91-107 04/88 H9 DENT 53 91-109 04/88 H9 DENT 68 91-111 04/88 H9 DENT 56 91-113 04/88 M9 DENT 22 91-115 04/88 C9 + 2.00" DENT 8 04/88 H9 DENT 38 91-117 04/88 H9 DENT 49 91-119. 04/88 H9 DENT 6 91-127 04/88 H9 DENT 32 91-129 04/88 C9 DENT 19 04/88 H9 DENT 96 91-131 04/88 H9 DENT 117 91-141 04/88 H9 DENT 6 O

Plants'CALVERT CLITFS UNITm1 Steam'Generaters.-12. = Outage:: 04/88. ~ b/' . QUERY: DENTS,ALL-MILS,ALL'-ELEV: FALL TUEES.),ALL-RL. ) k/ ROW'-LINE' OUTAGE -ELEVATION =

ND! C A TI ON' VULTS-92--

'36 -04/88 H9. DENT 13 9 2.- 38: ;04/88 ~H9-DEN"' ,72 92. 40 04/88-H9~ DENT-95 92-421 04/88 H9 -DENT-4 1 '. 92. 44 04/88-H9 DENT 37 92--

46..04/88

.C9 DENT 10 04/88 H9 -DENT .- 4 2 92-52,04/88 H9. DENT '55 92-54' 04/88 C9 DENT ~ ' 5 6 04/88: H9. DENT 51 92-- 56-.04/88 'H9 DENT 31' 92-58 04/88 .H9 DENT 29 92-60 04/88 H9 DENT 81 92-64 04/88 H9 ' DENT. 57 04/88' 'H9 DENT-42 92- '66: 04/88 H9 DENT '46 92 ' 68 04/88 H9 DENT" 63 04/88: H9 DENT 66t 92-70 '04/88 'H9 DENT-34 92. 72 104/88 H9 DENT .7 92, 74 -04/88' H9 DENT 7 92 1 76 04/88 H9 DENT 9 92- ~78 04/88 H9 -DENT 24 92. 80 04/88. H9 DENT 90 92-86. 04/88 H9 DENT 33-92-88 04/88 H9 DENT 95 92 ' 90 04/88 H9. DENT 18-92-94 ~04/88 H9 DENT 46 92-96. 04/88 H9 DENT' 122 92-98o 04/88 H9 DENT 82 E 92-100 04/88 H9 DENT 59: O 92-102 '04/88 H9 DENT 45

i 92-104 04/88 H9 DENT 50.

'd 92-106 04/88 H9 DENT' '68 92-_108 04/88 H9 DENT 86 92-110 04/88 C9 DENT 9 04/88 H9 DENT 69 92-112 04/88 H9 DENT 66 92-114- 04/88 H9 DENT 72 92-116 04/88 H9 DENT 77-92-118 04/88 H9 DENT 51 92-122- 04/88 H9 DENT 71 '92-124-'04/88 H9 DENT 21 92-126 .04/88-C9 DENT 6 92-128. 04/88 H9 DENT '148 92-130 04/88 H9 DENT 7. 92-'132 04/88 H9 DENT-67 93-' 39 04/88 H9 DENT 120 55 93-41 04/88 H9 DENT 93-43 04/88 C9 + 2.00" DENT 9 04/88 H9 DENT 24 93-45 04/88 H9 DENT 87 93-47 04/88 H9 DENT 85-93-49 04/88 H9 DENT 80 93-51 04/88 VH' DENT 6 04/88 H9 DENT 62 93-53 04/88 H9 DENT 125 93-55 04/88 H9 DENT 54 93-- 57. 04/88 H9 DENT 58 93-' 59- 04/88 H9 DENT 122 93-61 04/88 H9 DENT 34 93-~ 63 04/88 H9 DENT 41 93-65 04/88 H9 DENT 65 93- -67 04/88 H9 DENT 64 .93-1 69 04/88 H9 DENT 63 .D u

3_ mw .m - x- ' Plant: lCALVERT CLIFFS UNIT:1: .SteamlGensrater:,12 TOutage: '04/88 j g j-ag DENTS,ALL MILS,ALL ELEV-(ALL. TUBES),ALL-RL OUERY: 4 L; k.,[- ROW-LINE' OUTAGE' ELEVATION INDICATION VOLTS. (_, l4 93-71 04/88. H9 DENT- -63 93-: 73 04/88 "H 9 ' DENT 78 93- .75 -04/88 H9- . DENT 19 93 : 17 7, 04/88 H9 DENT 44 04/88- .C9 ' DENT. 15-93 ' 791 04/88 H9 DENT 33' '93- .83 --04/88, -H9 DENT 99

93-

'85 04/88-H9 DENT- "45-93-87 '04/88 'H9 DENT. 121. 93-89' 04/88, H9' DENT-59 -93..~93 04/88: H9 DENT.. .50 '93-95 04/88 H9 DENT 61 93-- 97 04/88. H9 ' DENT' 92 93-99 04/88-. 'H9 DENT.. ' 113. 93-'101 --04/88 H9 DENT. 64

93-103 04/88 H9 DENT 67' e

93-.105 04/88i -H9-DENT' 93-107' 04/88 H9- . DENT 88 93-109 04/88 ,H9 DENT 65 93.111 04/88 H9 DENT 99-93--113 04/88 H9' DENT 99 93-'115 04/88 H9: DENT 121 '93-117 04/88 H9 DENT 63 93--121 04/88-H9 DENT 71 93-123 04/88-H9 DENT 34 93-125 04/88-H9-DENT 39= H9 DENT 5 93-127' 04/88-93-129 '04/88_ H9 DENT -116 131. 04/88 'H9 DENT 49 93-133 04/88 H9 ' DENT 9 . 0 4 / 8 8' ' H9- + .1.90" DENT: 9 94-34 04/88-H9-DENT -28 7 94-36. 04/88 H9 DENT .20 D) '94-38- 04/88 H9 DENT 63 '94-40 04/88 H9 DENT 77 94-42;.04/88 H9 DENT- - 8 94-44 04/88 H9 -DENT. '38 DENT 94-46-04/88 CS. + 5.40" 6 04/88 H9 DENT 95 94-50-04/88 C7 + 25.20" DENT 10 04/88 C7 + 25.20" DENT 10 04/88 -C8 DENT-7 04/88. C8 + 9.00" DENT. 13 94-52- 04/88 H9 DENT '133 94-54' 04/88 H9 DENT 107' ' 56 04/88 H9 . DENT 38 94-58 04/88 H9 DENT 15 94-- 60 04/88 H9 DENT 87 .94-62 04/88 H9 DENT 45 94-64 04/88 H9 DENT 14 94-66 04/88 H9 DENT 43 94-68 04/88 H9 DENT 52 04/88 H9 DENT 56 94-70 04/88 H9 DENT. 58 94-72 04/88 H9 DENT 46 94-74 04/88 H9 DENT 48 94-76 04/88 H9 DENT 32 94-78 04/88-H9 DENT 64 94-80' 04/88 H9 DENT 193-94-86 04/88-H9 DENT 70-94-88 04/88 H9 ' DENT 37 94-90 04/88 H9 DENT 6 94-92 04/88 H9 DENT 40 94-94 04/88 H9 DENT 15 94- .96 04/88 H9 DENT 26 v.

-m .m Plant:.CALVERT' CLIFFS UNIT.1 Steam Generator: 12 Outage: 04/08: t L OUERY: DENTS.,ALL MILS,ALL ELEV FALL TUBES),ALL-RL-( ["y h - '\\_j ' ROW-LINE OUTAGE - ELEVATION INDICATION- 'VULTS 94-98 04/88 H9 DENT

*i

~94-11001 04/88 H9 DENT 129 94 "104 04/88 H9 DENT' 8 94 : 106' 04/88- - H9. DENT 113 94-108.04/88 H9 DENT 49-94.110 04/88' H9 DENT 124 94-112 04/88

C9

. DENT 8'. 04/88-H9 DENT 75 94-114 04/88 H9 DENT 73 94-116 '04/88 H9 DENT 89 94-118 04/88. H9' DENT 48 H9 DENT 29 94 120 04/88 ' H9 DENT-55 94-122 04/88 94 .124 04/88 H9 DENT 52-94-126 04/88 H9 DENT-92 94-128 04/88 H9 DENT 51 94-132 '04/88 H9 DENT 37: 22 95-37 04/88 H9 DENT . 143' 95-39 04/88 H9-DENT 95-43 04/88-H9 DENT-87 95-45 04/88 H9 DENT 17* 21.70" DENT 7. .04/88 H8 + 95-47 04/88 H9 DENT 82 95-' 49 04/88 H9 DENT 7 95-51 04/88 H9 DENT 32 95-.53 04/88 H9 DENT 143 95-55 04/88 H9 DENT 104 95-57 04/88 H9 DENT 69 95-59 04/88 H9 DENT = 13 95-63 04/88 H9-DENT 122 95-65 04/88 H9 DENT 72

/~~'N,

95-67 04/88 H9 DENT 118 ( J-04/88 H9 DENT 118 x/> 95-69-04/88 H9 DENT 106 95-71 04/88 H9 DENT 83 '75 04/88 H9 DENT 16 '95-77 04/88 H9 DENT 93 95-79 04/88 H9 DENT 50 95- .83 04/88 H9 DENT 82 95-85 04/88 H9 DENT 16 95-87 04/88 H9 DENT 158 95-89 04/88 H9 DENT. 95 95-. 91 04/88 H9 DENT 16 95-- 93 04/88 H9 DENT 50 95-95 04/88 H9 DENT 43 95-97 04/88 H9 DENT 6 95-99 04/88 H9 DENT 19 95- -105 04/88 H9 DENT 97 48 95-107 04/88 H9 DENT 95-109- 04/88 H9 DENT 72 95-111 04/88 H9 DENT 76 95-113 04/88 H9 DENT-81 95-115 04/88 H9 DENT 77 95-117 04/88 H9 DENT 46 95-119 04/88 H9 DENT 24 95-121 04/88 H9 DENT 72 95-123 04/88 H9 DENT 18 95-125 04/88 H9 DENT 47 95-127- 04/88 H9 DENT 68 95-129 04/88 H9 DENT 33 96-40 04/88 H9 DENT 19 96-42 04/88 H9 DENT 65 96-44 04/88 H9 DENT 59 96-46 04/88 H9 DENT 60 f 96-48 04/88 H9 DENT 70 IJ

m,-.

P1'ont
J CALVERT ' CLIFFS -UNIT 1:

Stear. Generatorst 12 l Outage: 04/88-1 OUERY: DENTS,ALL. MILS,ALL.ELEV (ALL TUBES),ALL-EL , 4: 's.I ROW-LINE OUTAGE ELEVATION ~ INDICATION Vul2S 96-50 04/88.' H9 DENT 80 ,- 52 04/88 H9 DENT .112 . 96-54 04/88 H9 DENT. 56 96-56 04/88 H9 DENT 72 58 04/88 H9 -DENT 103 96-62 04/88 H9 DENT 78-96- '64 .04/88 H9 DENT 166 04/88. H9 DENT 167 96-68 04/88-H9 DENT 88 ' 96-70 04/88 H9' DENT 213' 96-74 04/88 H9- ' DENT 105 96-76 04/88 H9 DENT 74 96-78 04/88 H9 DENT 76 96-80- 04/88 H9 DENT 138 96-84 04/88 H9 DENT '19 04/88-C9 . DENT 9 96- '86 04/88. H9 DENT. 100. 96-88 04/88-H9 DENT 126 96 - 90 04/88 H9 DENT 83 96-92 04/88 H9' DENT 44-96-94' 04/88 H9 DENT 36 96-102 04/88 H9 DENT 57 96-104 04/88 H9 DENT 75 96-106 04/88 H9 DENT 106 96-108 04/88 H9 DENT 108 112 04/88 H9 DENT 96 96-114 04/88 H9 DENT 112 96-116 04/88 H9 DENT 46 96-118 04/88 H9 DENT 89 96-120' 04/88 H9 DENT-46 ' 96-122 04/88 H9 DENT 42 .D. 96-124- 04/88 H9 , DENT 89 ( ). 96-'126 04/88 H9 DENT-65 97-37 04/88 H9 DENT 27 97-39 04/88 H9 DENT 47 97-43 04/88 H9 DENT 87 97-45 04/88 H9 DENT 56 97-47 04/88 H9 DENT 58 97-49-.04/88 H9 DENT 79' 97-51 04/88 H9-DENT 63 97-53 04/88 H9 DENT- '83 97-55 04/88 H9 DENT 18 97-57 04/88 H9 DENT-63 97-59 04/88 H9 DENT 92 97-61 04/88-H9 DENT 27 97-63' 04/88 H9 DENT 97 97-65 04/88 H9 DENT 92 97-67 04/88 H9 DENT 55 97-69 04/88 H9 DENT. 162 97-71 04/88 H9 DENT 100 97-73 04/88 H9 DENT' 50 97-77 04/88 H9 DENT 80 97-79 04/88 H9 DENT. 85 97-83 04/88 H9 DENT 21 97-85 04/68 H9 DENT 20 97-87 04/88 H9 DENT 86 97-89 04/88 H9 DENT 120 04/88 C8 + 7.50" DENT 12 97-91 04/88 H9 DENT 56 97-93 04/88 H9 DENT 18 97-95 04/88 H9 DENT 58 97-97 04/88 H9 DENT 24 97- '101 04/88 H9 DENT 56 .97 -105 04/88 H9 DENT 90 97-107 04/88 H9 DENT 107 .Iv

_g b -Plant: 'CALVERT CLIFFS UNIT 1 Steart ' Ge r e rstor: 12 [. Outage: 04/88 l OUERY: DENTS,ALL' MILS,ALL ELEV (ALL TUBES),ALL-RL A.. ' ROW-LINE OUTAGE ELEVATIOM INDICATION VULTS 97-111 04/88 H9 DENT 56 97-109 04/88 H9 DENT 68 97-113- 04/88 H9 DENT 85-97-115 -04/88 H9. DENT 67' l 97-117 04/88 H9 DENT 93 97-119. 04/88 H9 DENT 70 97-121 04/88 H9 DENT 55 97-123 =04/88 H9 ' DENT-28' 97-1125~ 04/88: H9 DENT 84 97-127 04/88. H9 DENT 72 98-36 04/88 H9 DENT 26 98 - -38 04/88 H9 DENT 20' 98-40 04/88 H9 DENT 60 98-44 04/88-H9 DENT 149 98 4 46 04/88 .H9 DENT 86 . 9 8 -' 48 04/88 H9 DENT 75 98-50 04/88 H9 DENT ' 113 98-52 04/88 H9 ' DENT 33 '04/88 H9 + 1.10" DENT B 04/88 CS + 16.70" DENT 13: 04/88 C8 + 18.20"' DENT 18 04/88 C8 + 19.40" DENT 16 04/88 CB + 20.90" DENT 10-04/88 C6 + 22.40" DENT 7' 98-54 04/88 H9 DENT 27-98-56 04/88 H9 DENT 76 98- '58. 04/88 H9 DENT 67 98-60 04/88 H9 DENT 96 98-62 04/88 H9 DENT 100 98-64 04/88 H9 DENT 90 98-66 04/88 H9 DENT 44 04/88 C9 DENT 12 . O) e 98-68 04/88 H9 DENT 125 L .04/88 HTS-SF DENT 83 98-70 04/88 HTS-SF. DENT 70 -04/88 H9 DENT 97. 98-72 04/88 HTS-SF DENT 33 04/88 H9 DENT 118' 98-74 04/88 HTS-SF DENT 14 04/88 H9 DENT 78 98-76 04/88 H9 DENT 14 04/88 HTS-SF DENT 6 98-78 04/88 HTS-SF DENT 9 04/88 H9 DENT 23 98-80 04/88 HTS-SP DENT 6: 04/88 H9 DENT -143 98-82 04/88 HTS-SF DENT 15 04/88 H9 DENT 84 98-84 04/88 HTS-SP DENT 6 04/88 H9 DENT 43 98-66 04/88 H9 DENT 88 98-88 04/88 H9 DENT 154 98-50 04/88 H9 DENT 75 98-92 04/88 H9 DENT 61 98-94 04/88 H9 DENT 106 98-96 04/88 H9 DENT 120 98-98 04/88 H9 DENT 41 98-102 04/88 H9 DENT 13 98-104 04/88 H9 DENT 12 98-108 04/88 H9 DENT 85 98-110 04/88 H9 DENT 107 98-112 04/88 H9 DENT 52 98-114 04/88 H9 DENT 53 98-'116 04/88 H9 DENT 57 98-118 04/88 H9 DENT 54 L

~~~ m ~ - - ~. Plant: CALVERT.~ CLIFFS UNIT 1 ' Steam Generator: [12 l! Outages -. 0 4 / 6 8 - e. OUERY: LDENTS,ALL MILS,ALL ELEV TALL TUEE51,ALLl-EL ~ g ,f Y. ( [ ROW-LINE -OUTAGE ELEVATION INDICATTON VOLTS = I f'

98 I20 ;04/88-H9

- DENT. 33 N 98-'122 04/88 H9 DENT - 48 - DENT 45-98 124" 04/88 H 9. - 1 98-126 04/88. H9- -DENT 54 98-128. 04/88 H9 DENT 80 798 132' 04/88 H9 . DENT 32 04/88 H8 + 19.60" ~ DENT-. 6. 04/88i HB + 20.80" DENT-12 '- -- 9 9 - 39 04/88-H9 10.20"' DENT 5 98 '142; 04/88. HTS-SE + DENT' 30 99- : 4 1. -' 0 4 / 8 8. H9-DENT 60 .99-43 's04/88~- H9-DENT 93 99-- : 4 5. 04/88-H9-DENT- '72 99- '47 04/88 H9 DENT 13 99-49 04/88 H9' DENT '72 '99-51 04/88 H9 DENT -10 99-- 53'.04/88 lH9-DENT. 56 99, 55 04/88 H9 DENT 55 99-' 57.,04/88-H9. DENT . 92 1 .99-59 04/88 H9 DENT 103 C9-61 '04/88 H9. DENT 81, 99-63 04/88f .H9 DENT 17

99-65' 04/88-H9 DENT

~77 '99-69 04/88-H9-

DENT 95 99-73: -04/88-

.H9 DENT 135-99. 75 04/88' H9 DENT 87 99. 77 04/88 H 9. DENT 54

99--.79 04/88

.H9 DENT 56 99-- 83 04/88 H9-DENT 118 99-85 04/88~ H9-DENT' 23 ',r"' 99-87 04/88 H9-DENT 100 9 9'- 89 04/88 H9-DENT 116 ('N 99-.91 04/88 H9 DENT-89 .b 04/88 H9 DENT-129 ~ 99-95 04/88-H9 DENT 118 99- .9 7 - 04/88 H9 DENT 70'- 99-99 04/88 H9 DENT '60' 101 04/88: H9 DENT 65 99.103 04/88 H9 DENT 69 99-105 04/88 H9 DENT. 75 99 .107-04/88 H9 DENT 86 99-109 04/88 H9-DENT 78 99-1111 04/88 H9 DENT 10 99-113 04/88 H9 DENT 7P 99-115 04/88 H9 DENT. 53 '99-117 04/88 H9 DENT 16 99.119 04/88-H9 DENT 71 99-121 04/88' H9 DENT 24 99 '123. 04/88 H9 DTNT ,100 '99.125-04/88 H9 DLAT 110 99-~127- 04/88 H9 DENT 87 99-129 04/88 H9 EENT 24 99-131 04/88 H9 DENT 8 100-38 04/88 H9 DENT 23 100 - 40 04/88 H9 DENT 34 100-42 04/88 H9 DENT 27

100-46 04/88 H9 DENT 74 100-48 04/88 H9 DENT 14 04/88 H9

+ 1.90" DENT 5 100-L 50' 04/88 C7 + 19.60" DENT 6 04/88 C8 + 5.'20" DENT 8 '04/88 H8 + 18.90" DENT 11 04/88 HB + 20.00" DENT 11 04/88 H8 + 20.40" DENT 7. 21.00" DENT 13 .04/88 H8 +

/%

ym s s u es. co. ..l.. ~ 3 a g i ~ T nuen aa r. un' ii_se***

  • n en n, aeo

,,. n ae **.<>. e n c o c o V enee e:n 1CALVERT CLIFFS UNIT 1 Steam. Generator: 12 h - Outagor 04/88 Plant: rv i OUERY: DENTS,ALL MILS,ALL ELEV (ALL TUEES),ALL-EL i u ' ROW-LINE OUTAGE ELEVATION INP! CATION VOLTS i,\\\\')' 22.10" DENT 20' 04/88 HB '+ 04/88 H9 DENT 18 z 100-52- 04/88 H9 DENT 75 100-54 04/88 H9 DENT. 45. 100-56 04/88 H9 DENT 81 100-' 58 04/88 H9 DENT 73 100c 60 04/88 'H9 DENT 100 100 62 04/88 H9 DENT 79 100-66 04/88 H9 DENT' 123 100-68 04/88 C8 DENT 5 04/88 H9 DENT 13 04/88 H9 DENT 6 04/88 'H9 DENT-6 '100-70 04/88 H9 -DENT 49 100-72 04/88 H9 DENT 108 100-74 04/88 H9 DENT 102 100- .76-04/88. H9 DENT 96 100-78 04/88 H9 DENT 5 100-80 04/88 H9 DENT 120 100-84 04/88 H9 + 9.30" DENT 99 100-86 04/88 P9 DENT 75 100 - 88 04/88 H9 DENT 114 100-90 04/88-H9 DENT 45' 100-92 04/88 H9 . DENT 86 100-94 04/88. H9. DENT 120 100-96 04/88 H9 DENT 152 100-98 04/88 H9 DENT 126 100- 100 04/88 .H9 DENT 64 100- 102' 04/88 H9. DENT-77 100- 104 04/88 H9 DENT 105 A'- 100- 106 04/88 H9 . DENT 145 100- 108 04/88' H9 DENT-94 6d' 100- 110 04/88 H9 DENT 92 ~ 100- 112 04/88-H9 DENT 83 100- 114 04/88 H9 DENT 95 100- 118 04/88 H9 DENT 40, 100- 120 04/88 H9 ' DENT 88 100- 122 04/88 H9 DENT' 13 100-'124-04/88 H9 DENT 75' 100- 126 04/88 H9 DENT 40 17.60" DENT. 13 100- 128 04/88 C4 + 04/88 H9 DENT 15 101-' 43 04/88 H9 DENT 35 101-47 04/88 H9 DENT 22 101-49 04/88 H9' DENT 25 101-53 04/88 H9 DENT 38 101-55 04/88 H9 DENT 39 101-57 04/88 H9 DENT 44 101-59 04/88 H9 DENT 16 101-61 04/88 H9 DENT 56 101-63 04/88 H9 DENT 26 101-65 04/88 H9 DENT 31 101-67 04/88 H9 ' DENT 15 101-69 04/88 C4 + 8.90" DENT 17 101-71 04/88 H9 DENT 18 101-73 04/88 H9 DENT 76 DENT 63 101-75 04/88 H9 101-77 04/88 H9 DENT 9 L 101-79 04/88 H9 DENT 42 101-83 04/88 H9 DENT 82 101-85 04/88 H9 DENT 26 101. 87 04/88 H9 DENT 70 101-89 04/88 H9 DENT 21 101-91 04/88 H9 DENT 19 101-93 04/88 H9 DENT 30 z-__- __.---_ --- :-_--- _ _ _--- _ - --- - _ _ ------- _ _--_ - -----_- _ ----. _ _ _ ___ _ _ _ _ --__ _ _-- - _ -- _.

Plants CALVERT CLIFFS UNIT.1 StoamTGeneratort-12 .Ou tage s. 04/88 b QUERY: DENTS,ALL MILS,ALL ELEV (ALL TUEES),ALL-RL -p l Nj ROW-LINE OUTAGE ELEVATION INDICATION 'VULTS' l 101-95 04/88 .H.9 DENT 102 l' 101-97 04/88 H9

DENT, 72 101-'

99 04/88 H9 DENT 54 101-101 04/88 H9 DENT 11 l '101 103 04/88 H9 DENT 103 101-105 04/88 H9 DENT 5& 101 107 04/88 H9-DENT 94 101-109 04/88 H9 DENT 98

101-111 04/88 H9-DENT 42 101-113 04/88 H9

, DENT" 46 101--115 04/88 H9 DENT 28 101-119 04/88 H9 DENT 58 ) 101 121 04/88. H9 DENT 64 101-123 04/88 H9 DENT 22-l 101-125- 04/88 H9 DENT 40 102-44 04/88 H9 DENT 24 l 102-46 04/88-H9 DENT 58 102-48 04/88-H9 DENT 14 102-50 04/88 H9 DENT 64 102-.52 04/88 H9 DENT 25 102-54 04/88 H9 DENT 15 102-' 56 '04/88 H9 DENT 77 102-58 04/88 H9 DENT 38 t 102-60 04/88-H9 DENT 81 l 102- '62 04/88' H9 DENT 27 l 102-66 04/88 H9 DENT 91 102-- 68 '04/88-H9 DENT .45 102-70 04/88 H9 DENT 45 l -102-74 04/88 H9 DENT 76 H 102-76 04/88 H9 DENT 43 102-78 04/88 H9 DENT c2 l Q 102-80 04/88 H9 DENT 98 9.20" DENT 123 i 102-84 04/88 H9 + IV j. 102-86 04/88 H9 DENT 49 102-' 88.04/88 H9 DENT 96 ) 102 90 04/88 H9 DENT 31 .102-92- 04/88 H9 DENT 96 j 102-94 04/88 H9 DENT 145 l 102-96 04/88 H9 DENT 67 .,102-98 04/88 H9 DENT 77 '102-.100. 04/88 H9 DENT 66 i 102-104 04/88 H9 DENT 66 102-106 04/88 H9 DENT 23 ) 102-108 04/88 H9 DENT B5 102 110 04/88 H9 DENT 31 i 102 112' 04/88 H9 DENT 49 102-114 04/88 H9 DENT 30 102-116 04/88. H9 DENT 42 102-118 04/88 H9 DENT 59 102-120 04/88 H9 DENT 91 102-124 04/88 H9 DENT 48 102-126 04/88 H9 DENT 101 103-45 04/88 H9 DENT 69 ) 103-47 04/88 H9 DENT 53 103-49 04/88 H9 DFNT 35 103-51 04/88 H9 DENT 59 J03-53 04/88 H9 DENT 40 103-55 04/88 H9 DENT 3B 103-57 04/88 H9 DENT 47-103-59 04/88 C3 + 16.20" DENT 11 04/88 H9 DENT 78 I 103-61 04/88 H9 DENT 31 103-63 04/88 H9 DENT 77 103-65 04/88 H9 DENT 94 103-67 04/88 H9 DENT 111 j 4 [). ( 1 1 l

~_ Picntt CALVERT-CLIFFS' UNIT-1 Stosm Gonorator: 10 Outcge: 04/08 h ls OUERY: DENTS,ALL MILS,ALL'ELEV.(ALL TUBES),ALL-EL f). 1 j ROW-LINE OUTAGE' ELEVATION INDICATION VOLTS 103-71 04/88 H9 DENT 82 l,

103-- 73 '04/88.

H9 DENT. 78 103-75,04/88' H9 DENT 79 103-' 77 04/88~ H9 DENT 12 103-79 04/88 H9 DENT 62 103-83 04/88 H9 DENT 56 103-85 04/88 H9 DENT' 33 -103-87 04/88 H9 DENT 65 103-89 04/88. H9 DENT 65 103-91 04/88 H9 DENT 34 103-93 04/88 H9 DENT 65 '103-95 04/88 H9 DENT 79 103-97 04/88 H9 DENT 97 103-99 04/88 H9 DENT-48 103-101' 04/88 H9 DENT 6 103-103 04/88 H9 DENT. 15 103-105 04/88 H9 DENT 48 103-107 04/88 H9 DENT '33 103-113 04/88 H9 DENT 45 103-115' 04/88 H9 DENT 21 103-117 04/80 H9 DENT 1 6-103-119 04/88 H9 DENT 29 ~103-121 04/88 H9 DENT 77 103-123 04/88 H9 DENT 2f. 103-125 04/88 H9 DENT 34 104-44 04/88 H9 DENT 8 104-48 04/88 H9' DENT 7: '104-50 04/88 H9 DENT 51 104-52 04/88 H9 DENT 90 104-54 04/88 H9 DENT 105 104-56 04/88 H9 DENT 101 104-58 04/88 H9 DENT 47 - n' 104-60 04/88 H9 DENT 42 (\\s) 104-62 04/88' H9 DENT 31 104-64 04/88 H9 DENT 74 104-66 04/88 .H9 DENT 118 104-70 04/88 H9 DENT 23 104-72 04/88 H9 DENT 44 104-74 04/88 H9 DENT 11 104-76 04/88 H9 DENT 30 104-78 04/88 H9 DENT 34 104-80 04/88 H9 DENT-163 104-84 04/88 H9 DENT 39' 104-86 04/88 H9 DENT 88 104-88-04/88 H9 DENT 83 104-90 04/88 H9 DENT 48 104-92 C4/88 H9 DENT 57 104-94 04/88 H9 DENT 60 25 104-96 04/88 H9 DENT 104-100 04/88 H9 DENT 49 104-102 04/88 H9 DENT 15 104-114 04/88 H9 DENT 61 104-116 04/88 H9 DENT 41 104-118 04/88 H9 DENT 36 104-120 04/88 H9 DENT 89 104-122 04/88 H9 DENT 15 104-124 04/88 H9 DENT 39-104-126 04/88 H9 DENT 102 105-45 04/88 H9 DENT 42 04/88 H9 DENT 41 105-47 04/88 H9 DENT 31 04/88 H9 DENT 28 105-49 04/88 H9 DENT 25 04/88 H9 DENT 23 105-51 04/88 H9 DENT 58 tu

_7 Plants CALVERT CLIFFS UNIT 1 Stoam Generator: 12 Outogo: 04/88 -r OUERY: DENTS,ALL MILS,ALL ELEV.(ALL' TUBES),ALL-RL ,)' ROW-LINE-OUTAGE ELEVATION INDICATION VULTS 04/88 H9 DENT. 56 105-53 04/88 'H9 DENT 119 105-55 04/88 H9 DENT 97 '105 - 57.04/88-H9. DENT 36 105-59 04/88. H9 DENT 42 105-63' 04/88 H9-DENT e6 105-67 04/88 H9 DENT 80 105-69 04/88 H9 DENT 22 105-71 04/88 H9' DENT 26 105-73 04/88 H9 DENT 37 105-75 04/88 H9 DENT 35 105-77 04/88 H9 DENT 20 105-79 04/88 H9 DENT 36 105-83 04/88 H9 DENT 43 105-85 04/88 H9 DENT 30 105-87 04/88 'H9 DENT 56 105'- 89 04/88-H9 DENT 32 105-91 04/88 H9 DENT 6 105-93' 04/88 H9 DENT 62 105-95 04/88 H9 DENT 50 105-97 04/88 H9 DENT 55 105- 04/88 H9 DENT 54 105-101 04/88 H9 DENT 61 105-109. 04/88 H9 DENT 41 '105-111 04/88 H9 DENT 20 105-113 04/88 H9 DENT 67 105-115 04/88 C9 DENT 9 04/88 H9 DENT 56 105-117 04/88 H9 DENT 19 105-121 04/88 H9 DENT 31 f 105-125 04/88 H9 DENT 41 f'N, 106-42 04/88 C3 DENT 5 j 106-46 04/88 H9 DENT 13 V 106-48' 04/88 H9 DENT 25 106-50 04/88 H9 DENT 25 106-52 04/88 H9 DENT 95 106-54 04/88 H9 DENT 44 106-56 04/88 H9 DENT 21 106-58 04/88 H9 DENT 26 106-60 04/88 H9 DENT 37 106* 62 04/88 H9 DENT 30 106-64 04/88 H9 DENT 53 106- '66 04/88 H9 DENT 8 85 106-68 04/88 H9 DENT' ^ 46 106-70 04/88 H9 DENT 106-74 04/88 H9 DENT 29 106-76 04/88 H9 DENT 36 106-80 04/88 H9 DENT 18 106-84 04/88 H9 DENT 11 106-88 04/88 H9 DENT 60 106-90 04/88 H9 DENT 127 106-94 04/88 H9 DENT 47 106-96 04/88 H9 DENT 67 106-98 04/88 H9 DENT 80 106.100 04/88 H9 DENT 121 .106-102 04/88 H9 DENT 56 106-104 04/88 H9 DENT 96 -106-308 04/88 H9 DENT 63 106-104 04/88 H9 DENT 58 106-11C 04/88 H9 DENT 38 106-122 04/88 H9 DENT 67 106-12J 04/88 H9 DENT 38 106-176 04/88 H9 DENT 69 107-47 04/88 H9 DENT 26 107-41 04/88 H9 DENT 62 /N

_-n h .Plcnt: CALVERT CLIFFS UNIT ^1. ' Steam Ger.erater: 12-H Outage: 04/88 V E I QUERY: DENTS,ALL MILS,ALL'ELEY (ALL TUBES),ALL'-RL' OUTAGE ELEVATION-INDICATION MJLTS ) POW-LINE _107-49 04/88 H9 DENT 21 107-51 04/88 HS + 9.00" DENT-9 04/88 .H9 DENT 50 04/88 C8. + 6.60" DENT 7 107-~ 53 04/88 H9 DENT 30 107-55 04/88 H9 DENT 78 107-57 04/88 H9 DENT-49 107-59 04/88. H9 DENT 69 107-61 04/88 -H9

DENT

'46' 107-63 04/88 H9 DENT 42 107-67. 04/88 H9 DENT 13 107-71 04/88 H9 DENT 28 .107-73 04/88 H9 DENT 16 1107-' 75 04/88 H9 DENT 63 107-77. 04/88 H9 DENT 8 107-83 04/88 H9 DENT 80 107-85 04/88 H9 DENT IO 107-87 04/88 H9 DENT 37 107-89 04/88 H9 DENT 53 107-91 04/88 H9 DENT 99 107-93 04/88 H9 DENT 37 107-95 04/88 H9 DENT 30 107 : 97 04/88 H9 -DENT 32 107-99 04/88 H9 ' DENT 32 107-101 04/88 H9 DENT 62 i 107-107 04/88. H9 DENT 62 107-109 04/88 H9 DENT 55 107-113 04/88 H9 DENT 21 107-115 04/88 H9 DENT 23 107 '119 04/88 H9 DENT 11 107-121 04/88 H9 DENT 29 ' 1 0 7 '- 123 04/88 H9 DENT 27 p, 107-125 04/88 'H9 DENT 51 J- ;V 108-40-04/88 H9 DENT 11 108-' 46 04/88 H9 ' DENT 32 108- -48 04/88 H9 DENT 24 108-50 04/88 H9 DENT 42 108-52 04/88 H9 DENT 57 108-54 -04/88 H9 DENT 46 108-56 04/88 H9 DENT 48 108-58 04/88 H9 DENT 64 l 108-60 04/88 H9 DENT-60 108-62 04/88 H9 DENT 36 108-64 04/88 H9 DENT-35 108-66 04/88 H9 DENT 46 108-68 04/88 H9 DENT 99 108-70 04/88 H9 DENT 62 .108-72 04/88 H9 DENT 12 108-74 04/88 H9 DENT 15 108-76 04/88 H9 DENT 44 p. 108-80 04/88 H9 DENT 77 108-82 04/88 H9 DENT 79 108-84 04/88 H9 DENT 37 108-88 04/88 H9 DENT 7 108-90 04/88 H9 DENT' 125 108-92 04/88 H9 DENT

  1. 3 108-94 04/88 H9 DENT 54 108-96 04/88 H9 DENT 28 108-98 04/88 H9 DENT 33 108-100 04/88 H9 DENT 27 108-102 04/88 H9 DENT 18 108-104 04/88 H9 DENT 36 108-106 04/88 H9 DENT 25 108-108 04/88 H9 DENT 40 108-112 04/88 H9 DENT 28 OV

_ E.;.... <.... .e............. veg

Plant:~CALVERT' CLIFFS UNIT 1-Steam' Generator: 12

. Outage: ~04/88 OUERY: DENTS,ALLLMILS,ALL ELEV'(ALL TUBES),ALL-RL 'M " ROW-LINE OUTAGE ELEVATION INDICATION WL75 /' t 108 E114 -04/88 H9 DENT 5 108-116 04/88 H9-DENT 59 108-118' 04/88 H9 DENT 32 1: 108--120 04/88 H9 DENT 55 '108-122 04/88 H9 ' DENT 37 108-124 04/88 H9 DENT 42 108-126 04/88 H9 DENT 20 '109-39 04/88-H9 DENT 18 3 '109 - 41-04/88 H9~ DENT 12 109- .43 04/88 H9 DENT ~30 109-45 04/88 H9 DENT 52-

109-47 04/88 H9 DENT 25 109-49 04/88 H9 DENT' 17 109-51 04/88 H9 DENT 94 109--

53 04/88 H9 DENT- ~33 109 - 55 04/88 N9 DENT: 28 109-.57 04/88 H9 DENT 104 109-59 04/88 H9 DENT 33 109-63 04/88 H9 DENT 12' 109-65'.04/88 H9 DENT 39 109-67 04/88 VC + 15.30" DENT 9 04/88 H9 DENT 41. 109-69-04/88 H9 DENT 86 109-71,04/88 H9 DENT 17 109-75 04/88 H9 DENT 39 109-77 04/88 H9 DENT. 39 '109-79 04/88 H9 DENT 31 109-83 04/88 H9 DENT 42 109-85 04/88 H9 DENT 21 109-87- 04/88. H9 DENT 61 . j-s 109-89 04/88 H9 DENT 62 4- -109-- 91 04/88 H9 DENT 28 'V 109-93 04/88-H9 DENT 25 109-. 95 04/88 H9 DENT 42 109-101 04/88 H9 DENT 53 109-105 04/88 H9 DENT 54' 109-107 04/88 H9 DENT 59 109-109 04/88 H9 DENT 41 109-111 04/88 H9 DENT ~23 [. 109-113 04/88 H9 DENT 6 109-115 04/88 H9 DENT 38 '109-117 04/88 H9 DENT 123 109-119 04/88 H9 DENT 22 109-121 04/88 H9 DENT 29 109-125 04/88 H9 DENT 35 110-44 04/88 H9 DENT 53 6 110-48 04/88 H9 DENT 110-50 04/88 H9 DENT 70 110-52 04/88 H9 DENT 80 110-' 54 04/88 H9 DENT 11 110-56 04/88 H9 DENT 72. 110-62 04/88 H9 DENT -20 8 110-64 04/88 H9 DENT 110-66 04/88 H9 DENT 97 04/88 VC + 2.90" DENT 6 71 110-68 04/88 H9 DENT 110-70 04/88 H9 DENT 114 110-72 04/88 H9 DENT 26 6 110-74 04./88 H9 DENT 83 110-76 04/88 H9 DENT 110-78 04/88 H9 DENT 17 73 110-80 04/88 H9 DENT 56 110-84 04/88 H9 DENT 110-86 04/88 H9 DENT 21 69 110-88 04/88 H9 DENT v i I

y !Outsge:

04/88- '

IW S t e a r1 Ga r.e r a t o r : 12l

Plent CALVERT' CLIFFS UNIT 3

q. ,p,.. l OUERY: DENTS,ALL MILS,ALL ELEY (ALL.TUEES(,ALL-RL' (O - 1 y L OUTAGE. ELEVATTON

INDICATION VOLTS

. b./ ; ROW-LINE "'Y L110-.90: '04/88. H9 DENT 14 110 192- 04/88 H9 DENT 63 110-94: 04/88 VHL

DENT

-11 DENT- -14' 04/88- 'H9-i ~110 100! '04/88 H9 DENT. 15 .110- 102.04/88 H9 DENT 53' " L 1 1 0. 1 0 4']- 04/88 H9-DENT .71 110 108' 04/88 H9 DENT 22 l b -110.110 04/88: H9~ DENT. 14 l .110->112 04/88 H9 DENT 29 j -110-114 >04/88. H9 DENT-46- -l t: 1110- 116- 04/88 H9 DENT 46 H 110-'118 04/88; H9 DENT '767 110- 120 04/88-H9 DENT 53, i 110 '122 04/88 H9 DENT 34 a S'

1 110- 126 04/88 H9 DENT 111-43 04/88 H9

" DENT' yh. 33 '111-45 04/88 H9 DENT. Mg 50 i 111-49 04/88 H9 DENT

  • 4 11 j

111-51 -04/88 H9. ' DENT 34 111.- 53 04/88 H9, . DENT 36 ' { '111-55 04/88 i H'T DENT 27 111-57' 04/88 -H9 DENT. '37 l 111-61 '04/88 'H9 DENT-15-l -~111-65 04/88-H9 DENT 4 6.- l 111-69 04/88' H9-DENT 67 111-71 04/88 H9 DENT 77 -i 111- '75 04/88 H9 DENT 40 111-s77-04/88 H9 DENT S?- ) l 111-83 04/88 H9. DENT 52 l 111-87 04/88. H9 DENT 62 O 111-89 04/88 H9 DENT 49-111-91 -04/88 'H9 . DENT 42 V 111. 93 04/88 H9 DENT 57 111-95 04/88 H9 DENT 18 I 111-101 04/88 H9 DENT-29 j 111-103 04/88 H9 DENT 34 .111-~105 04/88 VC DENT 8 111-107 04/88 H9 DENT 22 111-' 111 04/88 H9 DENT 7 1 l 111-115 04/88 H9 DENT 38 111-117 04/88 H9 DENT 63 111-119 04/88 H9 DENT 81 111-123 04/88 H9 DENT 43 3 112-52 04/88 H9 DENT 40 1 112-54-04/88 H9 DENT' 61 I 112-66 04/88 H9 DENT 50 J 112-60 04/88 H9 DENT 43 1 112-64 04/88 H9 DENT 22 i '112-66 04/88 H9 DENT-81 .i 112-68 04/88 H9 DENT 27 1 112-70 04/68 H9 DENT 60 1 112-' 74 04/88 H9 DENT 61 l 112-78 04/88 H9 DENT 44 112- '80 04/88 H9 DENT 29 112-' 84 04/88 H9 DENT 27 112-86 04/88 H9 DENT .35 112-88 04/88 H9 DENT '45 112-- 90 04/88 H9 DENT 62 112-92 04/88 H9 DENT 74 '112-94 04/88 H9 DENT 18 04/88 VH DENT 27 1 04/88 VH + 1.00" DENT 9 ] l'r 112. 96 04/88 H9 DENT 19 i 112-102 04/88 H9 DENT 29 O i i i I l

-____________o

-w. - m y v-i' Plant L CALVERT-CLIFFS. UNIT 1 ' Steam: Generator:'12 fi

Outages, 04/88 QUERY: DENTS,ALL MILS,ALL ELEV (ALL'TUBESj,ALL-EL gf4.

ROW-LINE OUTAGE ELEVATION INDICATION VOLTS; 112-114 04/88 H9 DENT ,11 112-116 04/88 'H9 DENT 35 t 112-118 04/88 H9 DENT 104-112-122 04/88 H9 DENT 46 113-43-.04/88 H9 DENT 28 .113-45 04/88. H9 DENT' 26 ,113-53 04/88-H9 DENT 30 ~113-55 04/88 H9 DENT 34 113-57 04/88 H9 DENT 29 113-65 04/88 H9 DENT 31 113-69 04/88 H9 DENT 22 113-71 04/88 H9 DENT 40 '113-73 04/88 H9 DENT-62 113-75 04/88 H9' DENT 30 4'. 113-77 04/88 H9 DENT 39 113- ' 79 04/88 H9 DENT. 87 113-83 04/88 'H9 . DENT 81 113-85 04/88 H9 DENT; 28 +. 113-87 04/88 H9' DENT 42 113-89 04/88 H9 DENT 56 113-91 04/88 H9 DENT 40 113 - 93' 04/88 H9 DENT .64-113-95 04/88 H9 DENT 38-113- '99 04/88 H9-DENT 23 113-101 04/88-H9-DENT 11 113-103' 04/88 H9 DENT 9 113-119 04/88 H9-DENT 7 113-123 04/88 H9 DENT 74 114-54 04.'68 H9 DENT 58 114-56 04/88 H9. DENT 6 ( 114-58 04/88 H9 DENT 6 114-64 04/88 H9 DENT 30

  1. pt 114-68 04/88 H9 DENT 49
V) 114-72 04/88 H9 DENT 32 114-74 04/88 H9 DENT 66 31.30" DENT 15 114-76 04/88 HTS-SF

+ 114-- 78 04/98 H9 DENT 55 114-80 04/88 H9 DENT 61 114-84. 04/88 H9 DENT 11 .114-86 04/88 H9 DENT 8 114-88- 04/88 H9 DENT 32 114-90 04/88 H9 DENT '39 114-92 04/88 H9 ' DENT 13 114-94 04/88 H9 DENT 56 114-96 04/88 H9 DENT 6 114-114 C4/88 H9 DENT 7 114-116 04/88 H9 DENT 13 114-118 04/88 H9 DENT 11 32 114* 122 04/88 H9 DENT o 114-124 04/88 H9 DENT 19 114-126 04/88 H9 DENT 6 114-130 04/88 VH + 30.20" DENT 5 115-55 04/88 H9 DENT 8 115-73 04/88 H9 DENT 14 i 115-75 04/88 H9 DENT 7 l 115-77 04/88 H9 DENT 23 1115-79 04/88 H9 DENT 27 115-83 04/88 H9 DENT 68 115-85 04/88 H9 DENT 47-115-87 04/88 H9 DENT 65 .115-89 04/88 H9 DENT 25 115-91 04/88 H9 DENT 10 115-115 04/88 H9 DENT 25 115-123 04/88 VH + 4.00" DENT 9 / 04/88 H9 DENT 43

7. -

w a s o **.*** nec oco n e s t co cc. '...... Vago: .M, ebeen e'us. sunaba, < h e. s. o,....e* u s u or se. sun Steam Generator:cl' Plant: CALVERT CLIFFS UNIT 1' . ? Outage: /04/88, + QUERY: DENTS,ALL. MILS,ALL'ELEY ( ALL TUBES ), ALL-RL v _ iY. ~ { t j'- ./

  • V-l ROW'-LINE OUTAGE ELEVATION INDICATION VOL7S

[, 116-- 64 04/88 C7' 4 10.00" DENT 12 ,l ' DENT' 11 72 04/88' H9 116-~. '74 04/88 H9 DENT-29 5 116-DENT 45. 116- '6' 04/88 H9 l116' 78 04/88. H9 DENT 39 DENT. 9 116-80 04/88 H9 DENT' 36-t 116 - 84 04/88 H9 53 2 116-86 04/88 H9 -DENT-116-- 88' 04/88 H9. . DENT 13 l -116-90 04/88 H9 DENT' 16 l 116-- 92 04/88-H9 -DENT 21-j ,117-- '65 04/88 H10 DENT 23 117-

83. 04/88J H9-DENT 52' 117-85 04/88 H9 DENT.

48 117-87 04/88~ H9 DENT 67 l l

117-89- 04/88 H9 DENT 33 117-91 04/88 H9 DENT 49 7

l 117-93 04/88 H10 DENT 117-105 04/88 H10 DENT 42 ( 43-118-64 04/88 H10 DENT DENT. 24 !~ 118-82- 04/88 H9. DENT 8 118- '84. 04/88 H9 DENT -18 l 04/88 H10 118-86 04/88 H9 DENT 20 3

118-90 04/88

-H9 DENT 13' l l'18-92 04/88-H9 DENT- '35 j 7 l 118-- 94 04/88 VH DENT 118-'-102 04/88 H10 DENT 34' '( 1 118---108 04/88 HIO DENT 13 119-65 04/88-H10 DENT 66 i m 119-81 04/88 H10' DENT 18 6 119-83 04/88 H9 DENT 13 ) 7 l 119' 85. 04/88' -H9 DENT l 119-87 04/88 H9 ' DENT 20 l 119-89 04/88 H9 DENT 14 l 119-91 04/88 H9 DENT 10 119-93 04/88 VH DENT 40 7 1 119-97 04/88 H10 DENT '119- '101.04/88 H10 DENT 33 I 4 i' 119-105- 04/88 H10 DENT 48 119-107 04/88 H10 DENT 13 -l 5 120-52' 04/88 H9-DENT-120-66 04/88 H10 DENT 35 { 8 120-70 04/88 H10 DENT l 120-88 04/88 H9 DENT 22 i 6 l s l 120-92 04/88 H10 DENT 120-94 04/88 H10 DENT 14 1 14 l 120-96 04/88 H10 DENT 36 l 120- 100 04/88 H10 DENT 120- 102 04/88 H10 DENT 45 i 5 120- 104 04/88 H4 + 27.40" DENT-5 121. 59 04/88 H10 DENT 35 121-63 04/88 H10 DENT fn 121-65 04/88 H10 DENT 52 121-67 04/88 H10 DENT 32 7 I s 121-79 04/88 H9 DENT 33 -l 121. 81 04/88 H10 DENT 121-89 04/88 H9 DENT 37 i t 7 L 121-93 04/88 VH DENT 10 l 121-99 04/88 H10 DENT 71 -{ 121-101 04/88 H10 DENT 5 122-66 04/88-VC + 2 00" DENT 7 122-76 04/88 H10 DENT 14 122-82 04/88 H10 DENT .20 j 122-88 04/88' H9 DENT O 1 l l L :_

e. I'~ ' Plant:.CALVERT: CLIFFS. UNIT 1 Steam-Generator: 12 Outager' 04/88 i l: QUERY:. DENTS, ALL MILS, ALL ELEV- ( ALL' TUBES ), ALL-RL . ~N l ( ROW-LINE OUTAGE ELEVATION INDICATION VOLTS j l 122 100 04/88 H10 DENT 36 ~122-?102 04/88 H10 DENT-7 122-104 '04/88 H9 DENT. 6 123-63 04/88 H10 DENT 14 123-121- 04/88 .C5 + 28.70" DENT 11 124-54 04/88 H9 DENT 5 04/88 C7 + 4.40" DENT 8 124-62 04/88 H10 DENT 13. 124-116 04/88' C9 '+ 3.10". DENT 5 125-67.04/88~ VM + 29.10" DENT 8 125-83 04/88 VM DENT 6 126-94 04/88 VH. DENT 18-128-94 04/88L VH-DENT 21 130-94 04/88 VH DENT 7-130-96 04/88 VH DENT . 10 132' 94 04/88 VH DENT 7 134-108 04/88 VH + 24.80" DENT 7 24.70" DENT-8- 135-107 04/88 VH + 138-92 04/88 DC DENT 6 TOTAL: TUBES: 1105 {O 1 O

.j i . (. 't 4 STEAM GENERATOR 12 I. List with Plot of Tubes Plugged during the April / June ~1988 Outage. l I e O

l I <- snoe ->

  • R R E 2 2 2 5 8 8 8 8 8 R R S 8 8 8 % % R R R E 5.2
  • l I

rrrrrrrrr.................... .g., N l ,s.) AYMNYM 10h -es, l E ^ I i'i: ! _,,, g a t l' l -.B. 1 l l .6 -0,, ) H M h l'- l w% 0 i l I. 0,, w gE 5 C.D 4 H-Jg -D D< N l I 4, "E O os l ) l-s so i -er, to J* l l l l l E 4 ~, - ii ';ji! l!ll, O I!.__L.c..._t j i(D I lw !.l. , l 4._ l. a _.1 ! i i ,__7 .il- -en y ? l f - d I I t, I i 9 l-l/ I i .1 4.' I I l. l.d I -80,. go I i i i lt.I I l 4 j I g .. +- t t a__-n ! n l {! - [ -m h Sj g r_ 9 ji;ili.I..oli' t s / Pu - 8 j !iI i ' t-t a! 3. r " r' {-i -!, j l 'i i ' 1 p p, " EP 3 l ..y -- b --l D = 08 1 k !.' ! ! i l s 4 - El l ! I l l W l6 I I - 91 I W f-i al. ~) g [ l," li l', ,, j,. l { t ll Q 3 . s. ",, } + i i i i i o l ' l>! l l ",l l l + l H l I o .1 l I i J l 6 l el Q. N C.D D - ar j 9 1 M g l = i 4 l ' l - 68 1 g "L $g I \\ l ~" g h l l O %I i, l t 4 $ s l w.c i i g f N ! ji i g o ' o e m - c i 1

i) b!

lii,

4I g } ,,,,,,,,,,,..,3 m,,,,.

  • m_.

g,, s, g I_ p. q m 7 9 1 q !f] ,i .s 5 7 8 2 .s R E N .a 7 G IS

S S

.a A E E B: S G U) E .a TW S A ( I T T LS AY L .a U TA A T O OT O TS T .s 4_ 8 l 8 8 8

4. I J

t / 4 _L' }L._- .a l G l 3 .a E 4 f_

s

. a , 74_:l .a D 'L .I_ l O ) (0 y .a C pl_ e 2 p t s.l iI4 N 1 I t.:3, .e [ T { O A C I R Y-f 9 . !L. c .a D O A P E T 2 e= _ _ _. a p A E A 8 G R L 8-2 e .a n u G E P D_ N I U E T. O= L. L s_ .a P I C __ L G A a. G 4_ _. q,s._ g-a r_ = .a 8 S E 7 B 4_ __ ___. _ _ L_ L. y U g-T g s _ 4: O 9_ ; F g-4 T + O g-L P g 2 1 1 g i T I G E r. g-r S l_ 7 t S F m 4 F )7 u I 2 g-L C6 e f 8 T/ H T R4 D g m E0 E V M o L c A y g C D E. 4 O e E U. T: G PO 3 .._ L_. L..- NA R _ L l_ AT g u LU .B l g-q ,,,g I g ,f g[ . gEgg3 r

-n Plants CALVERT CLIFFS UNIT l' Steam Generstor: 10 Outages' 04/88 lli -OUERY: PLUGGED - MECH-W, HTS-PF (OUT OF-SERV),ALL-EL 7 ROW-LINE-OUTAGF FLEVATION INDICATION 1-45 04/88 HTS-PF PLUGGED - MECH-W 10- 108 04/88 KTS-PF PLUGGED - MECH-W 31-41-04/88 HTS-PF PLUGGED - MECH-W 32-40: 04/88 HTS-PF PLUGGED -' MECH-W' 56-108 04/88-HTS-PF PLUGGED - MECH-W 60-58 04/88 HTS-PP PLUGGED - MECH-W 61-65 04/88 HTS-PF PLUGGED - MECH-W 61 105 04/88 HTS-PF PLUGGED - MECH-W 68-74 04/88-HTS-PF PLUGGED - MECH-W 70-84 04/88 HTS-PF-PLUGGED - MECH-W 70-96 04/88-HTS-PF PLUGGED - MECH-W 71-97 04/88 HTS-PF PLUGGED - MECH-W 73-~ 93 04/88 HTS-PF PLUGGED - MECH-W 73-97 04/88 HTS-PF PLUGGED - MECH-W 73-99 04/88 HTS-PF PLUGGED - MECH-W 74-86 04/88 HTS-PF PLUGGED . MECH-W 74- .94 04/88 HTS-PF PLUGGED - MECH-W 74. 96 04/88 HTS-PF PLUGGED - MECH-W 75-95 04/88 HTS-PF PLUGGED - MECH-W 76-90 04/88 HTS-PF PLUGGED'- MECH-W 76-92 04/88 HTS-PF PLUGGED - MECH-W. 77-85 04/88 HTS-PT PLUGGED - MECH-W 77-89 04/88 HTS-PF PLUGGED MECH-W 78-86 04/88 HTS-PF PLUGGED - MECH-W 78-- ~90. .04/88 HTS-PF PLUGGED - MECH-W 81-91-04/88 HTS-PT PLUGGED - MECH-W TOTAL TUBES: 06 i m 4 l l ( 1

O L -

-n Plant: :CALVERT CLIFFS UNIT 1 Steam Generator: 12 Outage: 04/88 QUERY: -PLUGGED - MECH-W, CTS-PF (OUT OF SERV),ALL-RL .f. jm.; i]1 ROW-LINE OUTAGE ELEVATION INDICATION ~ 1-45- 04/88 CTS-PF PLUGGED - MECH-W 10-'108 04/88 CTS-PF PLUGGED - MECH-W 31-41 04/88-CTS-PF PLUGGED - MECH-W 32-40 04/88 CTS-PF ' PLUGGED - MECH-W-56-108 04/88 CTS-PF PLUGGED - MECH-W 60-58 04/88 CTS-PF PLUGGED - MECH-W 61-65 04/88 CTS-PF PLUGGED -' MECH-W 61-105 04/88 CTS-PF PLUGGED - MECH-W 68-74 04/88 CTS-PF PLUGGED - MECH-W 70-84 04/88 CTS-PF. PLUGGED - MECH-W 70- '96 04/88 CTS-PF PLUGGED - ' MECH-W 71-97 04/88 CTS-PF PLUGGED - MECH-W 73-93 04/88 CTS-PF PLUGGED - MECH-W 73-97 04/88 CTS-PF PLUGGED - MECH-W 73-- 99 04/88 CTS-PF PLUGGED - MECH-W 74-86 04/88 CTS-PF PLUGGED - MECH-W 74. 94 04/88-CTS-PF PLUGGED - MECH-W 74-96-04/88 CTS-PF PLUGGED - MECH-W 75-95- 04/88 CTS-PF PLUGGED - MECH-W 76-90 04/88 CTS-PF PLUGGED - MECH-W 76-92 04/88 CTS-PF PLUGGED - MECH-W '77-85 04/88 CTS-PF PLUGGED - MECH-W 77-89 04/88 CTS-PF PLUGGED - MECH-W 78-86 04/88 CTS-PF PLUGGED - MECH-W 76-90 04/88 CTS-PF PLUGGED - MECH-W 81-- 91 04/88 CTS-PF PLUGGED - MECH-W 94-66 04/88 CTS-PF PLUGGED - MECH-W TOTAL TUBES: 27 i .f e V O

Pzgs 1 of 3 -/ . Steam Generator i12 Tubes Plugged During the April 1988 -( Outage: EGN LINE REASON FOR PIDGGING 1 45 Eddy Current Testing. Indication of 49% wall' loss originating on the outside diameter of the tube' at CTS-SF+0.50 inches. 31 41. Eddy current Testing Indication of 47% wall loss originating'.on' the outside diameter' of the tube at HTS-SF+0.7 0 ' inches. 32 40 Eddy Current Testing Indication' of 42% wall loss originating on.the outside diameter of the tube at HTS-SF+0.70 inches. 61 65 Eddy Current Testing Indication: of 42% wall loss originating on' the outside diameter of the tube at HTS-SF+0.70 inches. t 61 '105 Eddy Current Testing Indication of 49% [ /~' wall loss originating on the outside diameter of the tube at HTS-SF+1.00 inches. 70 84 Eddy Current Testing Indication of 145% wall loss originating on the outside diameter of the tube at HTS-SF+0.70 inches. 70 96 Eddy Current Testing Indication of 64% wall loss originating on the outside diameter of the tube at HTS-SF+0.70' inches. 71 97 Eddy Current Testing Indication of 47% wall loss originating on the outside diameter of the tube at HTS-SF+0.50 inches. 73 93 Eddy Current Testing Indication of 54% wall loss originating on the outside F. diameter of the tube at HTS-SF+0.70 inches. 74 96 Eddy Current Testing Indication of 45% f-wall loss originating on the outside diameter of the tube at HTS-SF+0.60 O inches.

Paga 2 of 3 Steam Generator $12 Tubes Plugged During the April 1988 Outage: EQH M REASON FOR PIDGGING 75 95 Eddy Current Testing Indication of 67% wall loss originating on the outside diameter of the tube at CTS-SF+0.70 l inches. 76 92 Eddy Current Testing Indication of 53% wall loss originating on the outside diameter of the tube at HTS-SF+0.60 inches. 77 85 Eddy Current Testing Indication of 52% wall loss originating on the outside 3 diameter of the tube at HTS-SF+2.70 inches. 77 89 Eddy Current Testing Indication of-43% wall loss originating on the outside diameter of the tube at HTS-SF+2.20 inches. 78 86 Eddy Current Testing Indication of 44% wall loss originating on the outside ,9 diameter of the tube at HTS-SF+0.60 inches. 78 90 Eddy Current Testing Indication of 47% wall loss originating on the outside diameter of the tube at HTS-SF+1.30 inches. 94 66 Cold leg side plugged. Cold leg tube plug found to have been installed into adjacent tube (R93 L67) during the 1986 Refueling Outage on Unit ~1. See LER 317/88-03. 10 108 Eddy Current Tacting Indication of 38% wall loss originating on the outside diameter of the tube at HTS-SF+0.80 inches. 56 108 Eddy Current Testing Indication of 31% vall loss originating on the outside diameter of the tube at HTS-SF+1.40 inches. 60 58 Eddy Currcnt Testing Indication of 16% vall loss with high voltage signal 9 originating on the outside diameter of the tube at HTS-SF+0.60 inches.

Piga.3 off3 ) i 'V { Sm Generator $12. Tubes Plugged During the April 1988 BQH LIHE REASON FOR PIRGGING 68 74 Eddy. Current Testing. Indication 'of 38% wall'1oss originating on the outside diameter of the tube at. HTS-SF+1.20 inches. 73 97 Multiple Eddy current Testing ' Indica- ~ tions of-394, 19% and 36% wall loss originating on the outside diameter of the tube at HTS-SF+1.70, +1.10, and +0.50 inches, respectively.. ) ] 73 99 Eddy Current l Testing Indication of 26%- -wall. loss originating on the 'outside diameter of the tube at HTS-SF+1.10 inches. 74 86 Eddy Current Testing Indication of 38% wall loss' with high. voltage signal originating on the outside diameter of-the tube at HTS-SF+1.40 inches. I 74 94 Multiple Eddy Current Testing Indica-tions of 33%, 28%, and 13% wall loss O 'with high voltage signal originating on the outside diameter of the tube -at HTS-SF+1.40, +1.10, and +0.50

inches, respectively.

76 90 Eddy Current Testing Indication of 28% wall loss with high voltage-signal originating on the outside diameter 'of the tube at HTS-SF+1.50 inches. 81 91 Multiple Eddy Current Testing Indica-tions of 10% and 19% wall loss with high voltage signal originating on the out-side diameter of the tube at HTS-SF+1.50 and +0.50 inches, respectively. L l l 1

,O DALTIMORE OADAND ELECTRIC J I CHARLES CENTER. P.O. BOX 1475. BALTIMORE. MARYLAND 21203 NUCLEAR OPERAflONS DEPAlmAENT vent currs muc a powan etAerr May 19, 1988 U.S. Nuclear Regulatory Commission Docket No. 50 317 Document Control Desk License No. DPR 53 Washington, DC 20555

Dear Sirs:

The attached 1.ER 88 003 is being sent to you as required by 10 CFR 50.73. Should you have any questions regardin's this report, we would be pleased to j discuss them with you. Very truly yours, } .L:n:, W J.R. 14 mons Manager - Nuclear Operations Department n JRL:

piv cc: William T. Russell Director, Office of Management Information and Program control Messrs:

J.A. Tiernan W.J. 1.irpold 'ob:: cessrs: Thcmas Mage:ce

5. E. Jones, Jr.

A h Kecorcs Center W. T. Lyons F. J. Fixnno R. L. Wenderlich T. Foley J. W. Raynor P. E. Kacy L. B. Russell J. T. Carroll E. F. Wasson f American hbclear Insurer 9

~ _ _ _.. _ _ g, App #ovtD Ohes 100 Flewes saames ereu. LICENSEE EVENT REPORT (LER) 90 Cat r Isualet A (21 par.s.3 8&CILff T anaa85 lii 015 l 0 l0 l 0 l 3111 1 1 loFl 012 alvert Cliffs. Unit.1 ra. Incorrect Ste LE Centrator Tube Plurred Due to Personnel Error ewe =T DATS tot gga asunseln tai Asp 0NTDATE(Pt OTNGR e ACiklTit$ 40fVOLVSD toe s :f 8%y'*6 ,*8 WONYu Day ygam eaCJ6tTv =amas 00Caff asvesetacss 880ertu gav vtam team ,g 01510101 0 I I I 1!2 O!9 8 6 8l 8 0 l 0l 3 0l 0 O! 5 2l 2 8l8 0 isic 0:0 i 1 i TMs5 AMi e outstTT80 '"f***'Aert 70 TMt ReeucataneurTs Of te ce A l #0hauP ens er auspe of $he _ f (f tl ^ ePehTM moos *' 6 as sim semw sessm en=> 7:sim so mewnna esawns sessmen,i 7:ssw g nei O i 010 so msanism -si sessweiw eTwea_m7 g g l- "o"m*w'"n"n"wi lii.u.$.1MbdP ' W::s s sessensensi useiniesweisi glpy's:s 6%m yge,:; v.- ,,,,,n g,, LICeBSS8 Oostf ACT POR TMe8 Lem tist tea one avueen =amt AASA COOL 31 011 2I 6l01 -1418I E 5 mc and.11 consrats ons Lins poa saen coneone=T esikvaa seeCaman in Two meeen? nai cavn er m u oo-o e=T =g;ac-a;;,a,;,*ggej.g:q jis; C.vu er m co-o. ~T ag;^c at?l",Ja!!' ~ qyt ,, 5g M iM3%s i i i i i i i i $!$hEkh M l l 1 l t i ; l l l l l l l f uo.cf. oav vaan eu,nsuewf ab as.onT emoseTso nei e,s..esio

  • ^ ' ' " ' '

"""] ves rir-twetro swnrwo= aares '"E} no g g g aseT ct<u. e.w i nei During eddy-current testing of Calvert Cliffs Steam Generator No.12 on April 23, 1988, a plug was found in the outlet tube sheet in a tube adjacent to the tube which should have been plug 5ed. Combustion Engineering (CE) had installed the plug on December 9, 1986. The cause was personnel error. Contributing factors were an inoperable tube position indicating system on the robotic arm being used and poor video monitoring clarity. Calvert Cliffs personnel, assisted by a different contractor, are being used Use of CE now and were used prior to using CE, with no incidents of this nature. in the future will depend on their response to this event. The outlet end of the defective tube has been plugged. The incorrectly plugged tube has been tested and evaluated as good. 1 y-" c".,Ysi

ua uct:an u:vsarom,so mio. e. LICENSEE EVENT REPORT ILER) TEXT CONTINUATION ..ovie o .,o eine e.o. as as e si = ooc..,.,u ..c.uv "W.it l PT.i:' i Calvert Cliffs, Unit 1 e js jo jo jo l 3;1; 7 8l8 0l0l q Og0 Og 2 or 0 l2 vint e am..nm On April 23, 1988, during eddy current examinations of the tubes in Calvert Cliffs Unit 1 Steam Generator No. 12 (EIIS SB-SG), a plug was found in the outlet of tube R93L67 that was supposed to have been in adjacent tube R94L66. Tube plugging operations in this steam generator had been performed on December 9, 1986. That operation was performed by remote control from outside the steam generator using a robotic arm manipulator with video monitoring. Combustion Engineering's (CE) personnel, equipment and Quality Assurance Program were utilized to perform the plugging under contract by Baltimore cas and An audio visual tape recording of these operations was provided by CE. Electric. Review of the tape revealed that defective tube R94L66 had not been plugged on the outlet end, the plug intended for this tube was inserted into adjacent tube R93L67. Normally, an encoded tube position indicating system on the robotic arm is an additional indication of tube location, but that system was inoperable. Also, the video monitoring clarity was poor, making remote visual verification difficult. The root cause of this event is personnel error. The inoperable position indicating system and the poor visual monitoring capability contributed to this [ personnel error. Future Combustion Engineering has been given the details of this event. contracting of Combustion Engineering for steam generator plugging services will depend on their response and corrective actions. Calvert Cliffs is presently using its own personnel and procedures with These support from another contractor for steam generator tube plugging. procedures require post installation visual verification that plugs are installed in identified locations. Locations marked for plugs are also verified by these This was the practice prior to the one-time contracting of procedures. i Combustion Engineering steam generator tube plugging services, and no incidents of mis plu5ging defective tubes have occurred previously at Calvert Cliffs. Therefore, we do not expect reoccurrence. Defective tube R94L66 has been plugged. It contained a 44 percent through wall defect during the 1986 examination, and re-examination this spring showed Tube 121 growth through the last cycle while only one tube end was plugged. R93L67 was examined and is still not defectivo. The safety consequences of this event are not significant, Mad a rupture occurred in the defective tube, the plant is designed to respond and that event

Also, is analyzed in the Final Safety Analysis Report, Chapter 14, Section 15.

the extra tube plugged did not cause the total tubes plugged to reach the analyzed limit of no grantor than 100. No similar evants have occurred. Calvert Cliffs contact for this event is Bernie Rudell, 301-260-4815. .vsesein.44u-ames ..j o.

6 l APPENDIX III STEAM GENERATOR INSPECTION INFORMATION A. Steam Generator Support Location and Nomenclature B. Steam Generator Tube Sheet Pattern and Numbering System C. Eddy Current Inspection Acronyms { 9 O

-4 e i l 1 l STEAM GENERATORS CCNPP 142 I I-l t ) .a I vtat CAL Hov/CoteLts surroats - ve + - vu + - vC + \\evitamos Tuon t ~ EpitR LeME Of 51L AM 4 (,tNL R AT OR Wy, K ) (- K + \\ + Ci. i 7% [ (98'0)' 8"'C" d g soon suPPonts ~ 2 C. vtRisC AL 1 DI AGON AL g suPPcRt 5 (DH.VM.vM vC,0C) ARE ALL 4* THICK Hg C4 26'4 f'","u."i" I Cf ,e t 2a / I as C6' e 39 ' CetD Lte Moi Ltc f SUPPORTS { SUPPoets MS CS '[ 3g* ySUPPenis1TNeouCMB \\ Amt '804 CaAft*M$lCN ese C4 39' m3 1-C3 ALL pt AsuREM(Nis

  • ARE C/L TO C/ L 39 ON TUBE SUPPOR1s l

nt C3 y SM80uD un en INI II g \\, \\ Ces "is 4 - WPF ii t 3 r il l l Flows Contacterig Supports Abose 00h TS nows se or supponta suPPont otsouroes I -9 vu a 96 35 M VM DC I asas a ter.oK vu. oc.Cr GH3 7 te.HF OH.VM DC,C7.C2 7449 9 M HB,If7. 04 WM f1C. CF. CS, VC 94115 11

14. WK HL HF. DK WW. DC, Cf.C8. WC C9 116le 13 H10. HB. WK HC MF, DK VM. DC, C1. Ca. WC, C9. CIO N

J

g wy v ,vw~ m i-- ~ ~ - - - -.- - ~ _ _ _ t' ~

a. 5 g. e. a..

g aaaea ae:eeaa ea o 4 4 s e i e a a 8 8 4 0 4 4 4 8 8 g 8 8 e a e I a e e .........ggs E l M M t10H.... ..........a..... .qgs E (s i d .................e.......... ,tt / .ggs v/ gn \\ ...........................g Hun q J j .gp j .......................................g. 1 ............................................................................................ 934 j .p3 ................................................. qnn .............................g.. pq ...................................... man H m ...........................................................* HMN ..............................e .gn .........p..... ............................... ang 4 ................................................................. 433 p. j qun j gg ,1, %gn '.M } .W 3m iD C (., (f:p). 33 I............. O H . gg 4 i 4 s / i -.W s [.J - . pg t; i s,,/ .s lH ~ me C3 t 1 . gg W J ......................................e............................................................. . gg 1 IE sg ................................................................... g3 33 33 g . pp ................................................................................................e.e ........................................................................................ gr .................................................. gg .......................e...................... ............................................. gr .................................................. g3 8 . gr l 6 ...............8 35 33 ( <g O. to g fs g s p y g y j k I %m+f 6 ~ + ~ * * = - +. - - L- .. = n a. .~. M IN 98 391 4N1 *It SW AWI.id O*8

  • W NW I M M N

- +...

- gism i -- C. EDDY CURRENT INSPECTION ACRGiarsiS I DENT = DNT PLUG PLG PERMEABILITY PV INCOMPLETE INC RETEST RT RESTRICTED RES RETEST BAD DATA RBD DISTORTED INDICATION DI UNDEFINED SIGNAL UDS INDICATION NOT FOUND INF SQUIRREL SQR POSITIVE IDENTIFICATION PID NO TEST NT COPPER CU FIXTURE FIX TEMPLATE PLUG TP BULGE BLG INSIDE DIAMETER INDICATION IDI INSIDE DIAMETER VARIATION IDV INDICATION NOT REPORTABLE INR SLUDGE SIG EXTRA HARD ROLL XHR ROLL TRANSITION INDICATION RTI ABSOLUTE POSITIVE TRACE APT NO DETECTABLE DEGRADATION NDO (. NRH NOT ROLLED HOT NOT ROLLED COLD NRC G 5/88

Q! 'j s' v: 1.. f ., C, BALTIMORE -- .i. OAS ' AND. I ELECTRIC CHARLES CENTER. P.O. BOX 1475. : BALTIMORE, MARYLAND 21203. George C.0 Creel' 'Vice President. ' Nuclear, Energy _ 4 February 2 4',, 1 9 8 9 .~U.-S.; Nuclear Regulatory Commission Washington, DC 20555' ATTENTION:' Document. Control Desk

SUBJECT:

CalvertDCliffs Nuclear Power Plant' Unit Nos.-1 & 2; Docket Nos. 50-317 & 50-318 1988 Steam Generator _ Inspection Results Report

REFERENCE:

~ (a) Unit.1 & 2 Technical Specification 6.9.1.5.b: (b) Letter to NRC from J. A. Tiernan dated July 14, 1988, Unit 1 Steam. Generator Tubes Plugged (c) Letter to NRC from J.-A. Tiernan dated August 1, 1988,. Unit 1 Steam Generator Category C-3 Results Report Gentlemen: Reference (a) requires that we report, on an annual _. basis, the--results of steam generator tube ' examinations conducted i n ' t h e _ p'a s t year. This report includes the number and ~ extent of tubes examined, imperfections noted,. and-the identity of tubes plugged.- No _ steam generator tube-exa'minations were~ conducted on Unit ~2 during 1988. Enclosed please::: find the report of steam generator tube examinations conducted on Unit i during 1988. References (b) and (c) ' submitted other reports of the Calvert Cliffs Unit 1 1988 steam generator tube examination results. q l

j,. i Document Control Desk-February.24, 1989-Page 2 Should.you have any questions regarding this matter,1please do not hesitate to contact us. Very truly yours, l / i GCC/DJVP/mic - Enclosure cc: D. A. Brune, Esquire (w/o Enclosure) J. E. Silberg, Esquire (w/o Enclosure)' R. A.-Capra, NRC-(w/o Enclosure) S. A. McNeil,' NRC W. T.-Russell, NRC V. L. Pritchett, NRC T. Magette, DNR !}}