Text
_,
f pww/nrumr.vsrfranemerunsrrutswer-wms resr.saunnernezumspresm N
NCFCNsss U.S. NUCLEAR REGULATORY CoMMISSloN I
4
+=>
l CEFITIFICATE OF COMPLIANCE i
l io can T' FOR RADIOACTIVE MATERIALS PACKAGES il i e CERTIFICATE NUMBER b AEMiON NUMBER c PACKAGE IDENTIFICATION NUMBER
- d. PAGE NUMBER e TOTAL NUMSfR PAGES g
5768 8
USA /5768/AF I
4 l
2 paEAMBLE fl d
a Thrs certificate is issued to certif y that the par,k8ecino and contents described in item 5 below, meets the apphcable safety standards set forth in Title 10. Code j
g of rederai neguiations. ear 7i. -pacnaging and Tranwonatio.i of radioactive uatensi.-
p N
This certificate does not reheve the consignor from comphance with any requirement of the regulations of tne U S Department of Transportation or other
- I D
N apphCable regulatory agenCleS. IriCheng the government of any Country through or into whlCh the package will be transported jh I
N W!
N lE 3 MS CFRhMCATE IS ISSUED ON THE 9ATS OF A SAFETY ANALYS1$ AEPOAT OF THE PACKCATiON OF aEPOnT On APPti AGE DESIGN OA APPLICATION l
a iSsuioro m.
.,, -.m o TITLE ANo iOENTiF g
Babcock & Wilcox Company Babcock & Wilcox Company application b
d P.O. Box 11f46 dated January 29, 1982, as supplemented.
I
(
Lynchburg, VA 24506 1
d i
i I
(
c oOCKET e eEn 71-5768 1
,g l
= CONOf fiONS This certificate is conditional upon fulfilhng the requirements of 10 CFR q ft 11. as appliceDie, and the conditions specified below
.l i
e i
I f
(a) Packaging l
l (1) Model No.:
88-250-2 l
4 I
(
(2) Description I
d l
l Inner container is 11-1/2" 10,16-gage steel cylinder, 63-1/2" long, p
4 with bolted and gasketed top flange closure and seal welded bottom g
plate.
Inner container is centered and supported in a 22-1/2" ID by lg ll g
minimum 74" long, 16-gage steel drum by 1/4" diameter spring steel l
(
rods and vermiculite.
The outer cover is secured by either a 12-gage jh d;'
closure ring or six (6), 1/2" diameter bolts. Maximum weight of lN
(
packaging and contents is approximately 650 pounds.
ll f
(3) Drawing
(!
l 4l' The BB-250-2 packaging is constructed in accordance with Babcock &
l W
Wilcox Drawing No. 10-F-771, Revision 5.
i 6
!f 6
\\
4l
!W Nl
!I I
lu i
I, r
I f
I
!i i
II
(
l W
I
(
l t
i I
I I
I I
jll i
87100'70142 070930 PDA ADOCK 07105760 l
I PDR I
C I
I l
l
,i l i
I I
!c Tiiiciaiiniar.musummamammpomma
j:
- - usjur y m m m u m m m mm m mmk = =m m'm m u n mm mmmmmmmm-A mmmmm mmmmm mmm m mm mmm I
/
I
'CONDmONS (continu:rd) l Page 2 - Certificate No. 5768 - Revision No. 8 - Docket No. 71-5768 I
I I
(b) Contents l
I (1) Type and form of material l
l (1) Uranium oxide enriched to a maximum 4.0 w/o in the U-235 isotope.
i Chemically-bound or. physically-bound water in mixtures is I
permitted. Slips or slurries that exhibit a visually discernible I
liquid secerid pha'se are prohibited.
I I
l 2gU/ccandenrichedkoam$xkm)um5.0w/o'intheU-235 isotop (ii) Bulk uranium oxide (U0 or V 0 i
The maximum H/U atomic < ratio, considering all sources of i
hydrogenous material within the inner container shall-not i
exceed 1.13..
q
',F.,
I
~ij p g...
I (iii) Uranium compounds which will~n'ot; decompose at temperatures up to l
7501F. Uranium may be enriched to i v.aximum 5.0 w/o in the U-235 i
isotope. The maximum H/U atomic ratio, considering all sources i
sof. hydrogenous material within the inner container shall not I
sxceed 1.5.
9 ",,
J o
l A
..gy,
I (iv')fUranium'oxidepellets,enrichedtoamaximumof4.0w/ointhe l
fU-235 isotope, The maximum 3H/U" atomic ratio, considering all-c sources of~ hydrogenous materf al?within the" inner container, shall y
not exceed 3.0.
a Li (2) Maximum quantity o} material per package i
'4 g
I (1). For the contentsTdescribed in 5(b)(1)(1)P g
,+.' -
J.1 i
iTotal contents not to exceed ~200 pounds', with the U-235 content 4
not to exceed 2.95 kg. 1he contents shall be contained within i
two-(2), 9-3/4 inch diameter by 12 inch high sealed stainless i
steel cans. Empty stainless steel. cans will beised to make up l-the remaining space within the inner container.
I (ii) Forthecontents'describehin5(b)(1)(ii):
1 Total contents not to exceed 315 nou'ndh witri the U-235' content I
~
i 8
not to exceed 6.25 kilograms. Th6 contents shall be contained l
within 9-3/4-inch diameter by 124nch high metal containers.
Empty metal cans will be used to ade up the remaining space-y within the inner container.
l l
l l
\\
I i
i i
Iq 4
.mm_.
_...._......m______,__m_ _mm_
e
'L= M - = = = = = =.-.m = =.= =_- - = = - = - - = = = = = = = = = = = = = = = = = - - - - - - = = - - -
T u
I
,X I
CoNo\\TIONS (continued)
'E I
Page 3 - Certificate No'. 5768 - Revision No. 8 - Docket No. 71-5768
!I I
I I
i f
(iii)
For the contents described in 5(b)(1)(iii) l l
l l
Total contents not to exceed 250 pounds, with the U-235 content i
I not to exceed 5.0 kilograms.
Four (4) steel drums containing not
'l I
more than 1.3 kilograms U-235 each shall be packaged in the 1
l shipping insert within the inner container as shown in Westinghouse l l
Electric Corporation Sketch SKA-252-1 and Dr& wing No. C7108D10.
li e
The steel drums shall be constructed in accordance with U.S.
i MilitaryStandardMS24347witnamaximumIDof8.5"andanominallIl 1
height of 15.4".
I I
l (iv) For the contents described in 5(b)(1)(iv):
l 1
W i
Total contentsinot>to. exceed 250 pounds, with the U-235 content i
I not to exceed 4.0 kilograms./ The contents shall be transported i
I in 9-3/4-inch diameter metal' containers. Empty metal containers I
l will be used to make up the remaining space within the inner i
l container.
8 i
i (c) Fissile Class.
II and III t
1
~
I (1) Miniinum transport index to be shown 'on I
j label for Fissile Class II.
~
'.i I
f (i)
Forthecontentsdescribedin5(b)(1)(1):.
3.0 l
i i
h (ii) For the contents describ'ed in 5(b)(1)(ii)',
i i4l
~ 5(b)(1)(111), 5(b)(l(iv):
0.5 1
i l
(2) Maximum number of packages!per shipment for E
g Fissile Class III' l
1 g
W (i) For the contents-described in 5(b)(1)(1):
30 a
4 f
(ii)
For the contents described in 5(b)(1)(ii),
5(b)(1)(iii),5(b)(2)(iv):
200 hl l
6.
The package authorized by this certificate is hereby approved for use under the f
3 general license provisions of 10 CFR 671.12.
p E
l 7.
Expiration date: January 31, 1988.
E' 4
1 i
,I N
,4
!,I W
l i
\\n>
\\
s 1
'l I
i i
H i
N i
R
............______.__...._,_..._l.
2 YQ M._ _m &
I
,1 l
}I l
coNom:Ns tcontinuw)
Page 4 - Certificate No. 5768 - Revision No. 8 - Docket No. 71-5768 I
I i
l I
i REFERENCES y
i lI I
Babcock & Wilcox Company application dated January 29, 1982.
l 1
jl l
Supplements dated: August 6 and 20, 1982.
ll l
'I q
FOR THE U.S. NUCLEAR REGULATORY COMMISSIONS I
7t i
N l
m#
l l
l Charles E. MacDonald, Chief l
l l
. Transportation Branch y
1 Division of Safeguards and l
l l
Transportation, NMSS i
I i
Date:
SEP 3 0 587 l
l I
i t
y i
- 5 s
l I
(
p p
p l
N e
n i
N i
4 l
l l
i 9
i g
i e
I s1 I
l 4
In l
n i
p E
I jH e
t li 4
N I
lv l
M l
v 5
9 N
E R
s h
5 e
c N
iN y
'N 4
E N
i i
l l',
i I
X i
R L ____________________ m _..;__ = m______________ _____ _ J!
l
- E-4s t #
'o UNITED STATES.
~,,
["
g NUCLEAR REGULATORY COMMISSION W A5HINGTON, D. C. 20656 g
1
\\,...../
Transportation Branch i
1 Approval Record Model No. BB-250-2 I
Docket No. 71-5768 Revision No. 8 o
i By application dated September 28, 1987, Babcock & Wilcox Company, Lynchburg, VA requested renewal of Certificate of Compliance No. 5768 in the absence of a request for renewal from the present certificate holder, Babcock & Wilcox Company, Apollo, PA. Babcock & Wilcox Company, Lynchburg, VA has been J
designated as the primary user of this packaging.
No changes have'been i
requested or made to the package since approval of the latest supplement dated
)
August 20, 1982.
j The certificate of compliance has been renewed until January 31, 1988 to provide the applicant time to submit complete and current sections on operating procedures, acceptance tests and maintenance programs.
wb k
+
Charles E. MacDonald, Chief Transportation Branch Division of Safeguards and Transportation NMSS
]
Date:
W 80 W 4
-l