y 7b-//f/
c' (y
RETURN 7Q 39gg
\\' N LA 87-34 Westingh0tlSe Water Reactor am 355 Electric Corporation Divisions Pittsburgh Pconsy!vania 15230 0355 June 19,1987 D. S. Nuclear Regulatory Commission eg Xk RECEIVED y@
ATTN:
Mr. Leland C. Rouse Fuel Cycle Safety Branch Division of Fuel Cycle, Medical, Jypq E u.tnucgQFcuwegy j;Dh Academic, and Commercial Use Safety Office of Nuclear Material Safety and Safeguards Anu j
N mus
/'
i Washington, DC 20555 M sutwn N
Gentlemen:
47TTD \\
REF: SNM-1107, Docket 70-1151 Plant Expansion Westinghouse hereby requests an amendment to License SNM-1107 to authorize the use of radioactive materials in the Southeast plant expansion at the Columbia Site.
An amendment request for the Southwest plant expansion will l
be submitted at a later date.
This application consists of changed p ages to Section 1
(Safety Demonstration) of the license.
All new activities shall be suoject to the existing radiological and nuclear criticality safety criteria and the effluent controls and limits in the license.
l l
l We expect to commit radioactive materials to this area by mid-August.
Consequently, we would appreciate your timely review of this application.
Enclosed is a check for $150.00.
l If you have any questions, please write to me at the above address or telephone me at (803) 776-7610, Extension 3247.
Very truly yours, 87072001G3 870619 PDR ADOCK 07001151 h
r A. J. Nardi, Manager p
NES License Administration WP1533E:3p.1 pourM b
d uttac Enclosures esg}3 g
[
b w =m.......ff.......... v. _ w. w m
s a x. m.. m 6 w
y
.f......../ f R.'. /. '.3 Amcani. Fca CD10 E %2acci..ARX.'.'
12S3 f t w e e c,.... u.........
O e <-
l 1
l '
l J
l 1
l I
'i
,l i
L:o' v"in. i j4 0. __._ _[_.".,__[!_ _ ---
.m 1
r w uku,n, n 8 9 M-v u,si R
/
..n M
uti;c.Ur UUv. __ d.:..... -....
O i b..
i em%..w.emenqg af ' f 4 whew eyr weag y<gge-w-
[N. E._,_,
[.h' U r i. -,, - - - -
{ v'$ - t 44 t
t 1:
u s
.J.L
~
mv m
( l'* lit
\\
s v 1 v _,, _
b1 L ::
,F i
DATE
.. w
\\
.,~
lif MAL _ -
' /
i I
I
~-^~~
. _ _.__________.__.____.______._.____________j
- 1.,
'1.12L Southeast Plant-Exoansion The following activities are authorized for the southeast. plant j
expansion:
(1) Metallurgical Laboratory (2) Mechanical Development Laborat.ory (3) Product' Design Test Laboratory.
(4) Health Physics Laboratory (5) Maintenance (6) Bulk Blending (7) Radioactive Material Storage (8). Radioactive Material Transfers All activities shall be subject to the existing radiological and nuclear criticality safety criteria and the effluent controls' and limits of Section 2, 3 and 4 of the license.
1.12.1 Metallurgical Laboratory Activities in this area include' sample preparation and polishing, testing and examination.
This area is limited to 1000 grams U-235.
1.12.2 Mechanical Development Laboratory Activities in this area include machining, milling,
- testing, welding, etc., associated with development projects.
I 1.12.3 Project Desinn Test Laboratory Activities in this area include fuel assembly hydraulic, vibratory.
and impact testing.
j 1.12.4 Health Physics Laboratory Activities in this area include instrument repair, calibration and testing, sample preparation and counting, respirator fit testing, urinalyses and source storage.
1.12.5 Maintenance Activities in this area include pump and valve repair and maintenance, tool room parts storage, and welding.
1.12.6 Bulk Blending Activities in this area include powder transfers,
- milling, blending and storage. All moderation control criteria descrJbed Docket No. 70-1151 Initial Submittal Date:
6/19/87 Page No.
1.12-1 License No. SNM-1107 Revision Submittal Date:
6/19/87 Revision No.
11
.in Section '2 of this license shall' apply to this area.
l 1.12.7-Radioactive Material Storage-
)
1 Activities in this area include powder, pellet. scrap and waste storage.
Nuclear criticality' safety storage criteria described'in Section 2 shall apply to this area.
1.12.8 ' Radioactive Material Transfers
)
Activities in. this area include transfers of radioactive materials to'and from process and storage areas.
.i I
i I
l l
i l
1 i
I a
Docket No. 70-1151 Initial Submittal Date:
6/19/87 Page No.
1.12-2 License No. SNM-1107 Revision Submittal Date:
6/19/87 Revision No, 11
7 l'
s l
si l
8
=
d l-E og an Iw I
y 2 2
g 1
WE i
I>%
p il E$3 pa m
aw-d Obb
[<
"~
tau.vmrwa 7
4,g.
aiz=
l
=
EEEP.,(
.)
$o$
-r i
_A n
! A..
5 g
a W3
,s I
l ew 2
ji l
02 l
s-
-m e
t 2A l
~8
[
8 aco1 sioa E$
j w =N-
/,N d~b==
==
==
sa sa g9 EiiaE i
1 4
I a]
I l
11J Illlili t ill lll111
-_4 _ _
,1T111ll1111111 111111 m.~
b k
k b
6 gj ye i
l xm m
I7 s
8 I
C i
sW EI5
/,'N I
858 I
N
- - m 3,, w i,l.+
D' NE
\\
m +,m++
Southeast Plant Expansion
~ """ inn nininnu r-Docket No. 70-1151 Initial Submittal Date:
4/30/83 Page No.
1.12-3 License No. SIM-1107 Revision Submittal Date:
6/b/67 Revision No.
11
I ELECTRIC 500 - STATION TANK FARM BOILER HOUSE 5 CALCIUM FLUORIDE LAGOON f2 CALCI F FLUORIDE PhAT D TANr W
LAGOON r1 HOUSE U Sb 70 UPDE
//
-O!L HnUSE
[( *
- COOLING TO*EAS SANITARY LAGOON
-(-
g"
$ TOLLAGE AREA i
SHIPP!Nr. CoMTalNER
,.NA
'Y.
. FUDE!SHING BLDr, "BUTLED" BUILDING S j
PROCESS WASTE LV00N5 -
,1 f,D~ -T NORTH L SOUTH di y
7 y
/
v w
o
- EXPANSION OFFICE b
SOUTHaEST ADDITION--
_ __l f,-
U[
NEw AE NK UNH STD# AGE TEMS EQUIP"ENT SNED
,co f
d WASTE TREAT"ENT 8tu!LDING HF Stepar,E TANIf
~[
MT UF6 WASHING AND DECERTIFICATION Q"
WA5TE STORME BUILDING
/
(~~[ CAFE
)
I
~ ~ ~
DANIEL C'*ST, BLDG, C
ADVANCED Wp g EATPENT i
IFP BLDG FERKING
\\
DE!ON! ZED WATER BLDG.
SOUTHE AST ADDITION l
.--)
E--- E U --i
,l HF/M P!XING BLDG.
\\
N o
ISO 300 450 600 iwa---
i SCALI OF FEET
- DETAILED COLUMBIA SITE PLAN DL4NT ENTRANCE I
Docket No. 70-1151 Initial Submittal Date:
4/30/83 Page No.
1.3-2 License No. SNM-1107. Revision Submittal Date:
6/19/87 Revision No, 11
r;
]
J q
l TABLE OF CONTENTS j
Section.
Pace Table of Contents l'
Schedule of Revisions lii l-Revision Record viii 1.
Safety Demonstration Table of Contents
.1.0-1 1.1 Introduction and Corporate Information 1.1-1 1.2 General Description of Operations 1.2-1
'I 1.3. Site Description 1.3-1
-j 1.4. Organization 1.4-1 1.5 Personnel 1.5-1 1.6 Emergency Procedures 1.6-1 l
1.7 Radiological Safety Procedures
- 1. '7-1 1.8 Nuclear Criticality Safety 1.8-1 1.9 Processing Operations 1.9-1 1.10 Off-Site Release Evaluations 1.10-1 1.11 Nonradioactive Industrial Products 1.11-1 1.12 Southeast Plant Expansion 1.12-1 2.
Minimum Specifications and Capabilities Table of Contents 2.0-1 2.1 Scope of Licensed Activities 2.1-1 2.2 Facility and Equipment Design Features 2.2-1 2.3 Nuclear Criticality Safety Limits 2.3-1 2.4 Minimum Conditions of Operation 2.4-1 2.5 Emergency Plan 2.5-1 2.6 Operating Procedures 2.6-1 2.7 Environmental Monitoring 2.7-1 2.8 Decommissioning 2.7-1 3.
Administrative and Procedural Requirements Table of Contents 3.0-1 3.1 Administrative Controls 3.1-1 I
3.2 Surveillance Requirements 3.2-1 l
3.3 Technical Qualifications 3.3-1 l
Docket No. 70-1151 Initial Submittal Date:
4/30/83 Page No, i
License No. SNM-1107 Revision Submittal Date:
6/19/87 Revision No.-
11 i
' SCHEDULE'0F-REVISIONS Page Revision Page Revision I
Number Number Number Number i
11~
1.5-3 2
I 11 10 1.5-4 2
111'
'll 1.5-5 2
iv 3
1.5-6 2
y 11-1.6-1 2
vi 10 1.7-1 2.
vii 10 1.7-2 2'
l' viii 11-1.8-1 2-1.0-1 2
1.~ 8-2 2
1.0-2 2
1.8-3 2
1.1-1 2
1.8-4 2
1.1-2 2
1.8-5 2
1.2-1 2
1.8-6 2
1.3-1 2
1.8-7 2
1.3-2 11 1.8-8 2
1.3-3 2
1.8-9 2
1.3-4 2
1.8-10 2
1.3-5 2
1.8-11 2
1.3-6 2
1.8-12 2
i 1.3-7 2
1.8 2 1.4-1 2
1.8-14 2
1.4-2 2
1.8-15 2
1.4-3 2
1.8-16 2
j 1.4-4 2
1.8-17 2
j 1.4-5 2
1.8-18 2
1.4-6 2
1.8-19 2
1.4-7 2
1.8-20 2
1.4-8 2
1.8-21 2
l 1.5-1 2
1.8-22 2
l 1.5-2 2
Docket No. 70-1151 Initial Submittal Date:
4/30/83 Page No.
iii License No. SNM-1107 Revision Submittal Date:
6/19/87-Revision No.
11 I
l L
-__z---___
-_ -__._-__j
SCHEDULE OF REVISIONS
- Page'-
Revision Page-
' Revision Number
' Number _
Number Number 1.9-49 2
1.'9-80 2
1.9-50 2
1.9-81 2
'l.9-51
,2 1.9-82 2
]
i 1.9-52 2
1.9-83 2-1.9-53 2
1.9-84" 2
l l.
1.9-54 2
1.9-85 2
1.9-55
- 2-1 9-86 2
4 1.9-56 2
1.9-87 2-l 1.9-57 2-1.9-88 2
L 1.9-58 2
1.9-89.
2
- i 1.9-59 2
1.9-90 2
1.9-60 2
1.9-91 2
1.9-61 2
1.9-92 2
1.9-62 2
1.9-93 2
1.9-63 2
1.9-94 2
i i
1.9-64 2
1.9-95 2
1.9-65 2
1.9-96 2
1.9-66 2
1.9-97 2
1.9-67 2
1.9 2 1.9-68 2
1.9-99 2
1.9-69 2
1.9-100 2
1.9-70 2
1.9-101 2
1.9-71 2
1.9-102 2
1.9-72 2
1.10-1 2
i 1.9-73
.2 1.10-2 2
1.9-74 2
1.10-3 2
1.9-75 2
1.11-1 10 1.9-76 2
1.11-2 10 1.9-77 2
1.11 10 1.9-78 2-1.11 10 1.9-79 2-1.11-5 10 l.12-1 11 1.12-2 11 1.12-3 11 Docket No. 70-1151 Initial Submittal Date:
4/30/83 Page No.
v i
License No. SNM-1107 Revision Submittal Date:' 6/19/87
' Revision No.-
11
REVISION RECORD Revision Date of l
_ Number Revision Pages Revised Revision Reason 1
12/12/83 1.9-32 through 1.9-76
. Respond to NRC questions i
inclusive, 2.2-10, in NRC letter dated 2.2-11, 2.3-1, 4.8-1 April 6,1983.
(
l 2
3/26/84 All pages' resubmitted Respond to NRC questions as Revision 2.
See in NRC letters dated wbmittal letter
. January 26, 1984 and attachment for de-February 23, 1984.
scription of changes.
3 1/4/85
.All pages resubmitted Respond to NRC as Revision 3.
See re-questions.
vision lines in right hand columns of.each page for specific changes.
4 6/25/85 New pages 2.2-12 and Licensing of uranyl 2.2-13 and revised nitrate storage tanks.
pages 2.3.1 and 2.3.'2.
See revision lines in right hand columns of each page for specific changes.
5 5/14/86 2.5-1 and 2.6-1.
Update of Emergency Plan Section.
6 8/8/86 2.2-3 Added criteria for positive:
pressure gloveboxes.
7 9/22/86 2.5-1 Update of Emergency Plan Section.
8 4/1/87 4.7-1 Added criteria for leak testing sealed plutonium sources.
9 4/20/87 4.8-1 Added criteria for disposal
.o f aqueous products.
]
10 4/24/87 New pages 1.11-1 through Added criteria for i
1.11-5 and revised page disposal of dewatered -
4.5-1.
calcium fluoride.
11 6/19/87 New pages 1.12-1 through Licensing of Southeast 1.12-3 and revised page plant expansion.
1,3-2.
Docket No. 70-1151 Initial Submittal Date:
4/30/83 Page No.
viii License No. SNM-1107 Revision Submittal Date: 6/19/87 Revision No.
11
Il' Page 1.9 Processing Operations 1.9-1 1.9.1 Conversion Operations 1.9-2.
1.9.2 Fabrication Operations 1.9-25 1.9.3 Laboratory Analysis 1.9-36 1.9.4 Scrap' Recovery Operations 1.9-36 1.9.5 Moderation-Controlled Processing Operations 1.9-42 1.9.6 Incinerator.
1.9-81 l
- 1. 9. '7 Chemical Manufacturing Development Laboratory 1.9-88 1.9.8 Purification of Contaminated Scrap through Solvent' 1.9-91 Extraction 1.9.9 UF6 Cylinder Washing and Decertification 1.9-101 1.9.10 Improved Fuel Processing Operations l.9-102 1.10 Off-site Release Evaluations
.1.10-1 1.11 Nonradioactive Industrial Products 1.11-1 1.12 Southeast Plant Expansion 1.12-1 l
l I
i j
i Docket No. 70-1151 Initial Submittal Date:
4/30/83 Page No.
1.0-2 l
License No. SNM-1107 Revision Submittal Date: 6/19/87 Revision No.
'll
WestHghouse E:ectric Corporation. Tele Computer Center, Box 2518, Pittsburgh, Pa.15230 (412) 244-2441 YOUR INVOICE OR IN voIC E PRtlGhi PRO. No DATE Cross Amoumf DISCOUNT
- E""O AMouhi T Wni 052787USC 052'/7BC55 225511 150.00 0.00' 150.00 LICENSE AME NDMENT L A 8 7 $ fle l
l M000000966 TOTALS 150.00 0.00 150.00 918sRhDous mattne @vronunst a,a m
Me. llon. Ban.k..
Pay To Order Of p
tu..
A......,<i..6 U S NUCLEAR PEGULAYOPY 05/29/87
- 150.00 COMMISSION OFFICE OF CONTPDLLEP WASHINGTON DC 20555 lieadquarters Disbursing Account - 9400
)
n' 3 7 2 G 9 t,n=
- O t. 3 30 L EO 18:
D O O a'9 5 8 9n'
*8""""""""
F 8
i
'