_ _ _ _
a *
/NEA idaho National Engineenny Laboratory June 30, 1987 Mr. Mayo Carrington U.S. Nuclear Regulatory Commission Phillips Building 7920 Norfolk Avenue i
- Bethesda, MD 20814 TRANSMITTAL OF THE FINAL TER FOR RELAP5YA CODE REVIEW - PDW-16-87 Ref: G. E. Marx ltr to S. B. Milam, " Transmittal of NRC Form 189 Revision 4 for Operating Plant Licensing Issues Program",
(MARX-289-86)
Dear Mr. Carrington:
Review of the RELAP5YA computer code, submitted by Yankee Atomic Electric Company, has-been completed. The enclosed final Technical Evaluation Report (TER) documents this effort and is for your information.
The final TER has been revised as per NRC staff comments we received.
Please contact me (583-9348) if we can be of further assistance.
Very truly y urs,
/
/ /?.
?
i
, YN w.
Philip Wheatley
/
Reactor Simulation and Analysis
Enclosure:
As Stated cc:
C. C. Graves, NRC/NRR (2)
M. W. Hodges, NRC/NRR G. L. Jones, DOE-ID J. O. Zane, EG&G Idaho, Inc. (w/o Enc.)
g. god'g 8707200057 870630 b
PDR ADOCK 05000271 P
PDn R00I h E5cG..no. sne.P.O. Box 105 Idaho Falls, ID 83415 i\\s