ML20235M518

From kanterella
Jump to navigation Jump to search
Exam Rept 50-395/OL-86-01 on 860813 & 0912.Exam Results:Two Senior Reactor Operator (SRO) (IC) Candidates Passed & One Reactor Operator Candidate Did Not.Oral & Simulator Exams Will Be Administered to Remaining SRO (IC) Candidate Later
ML20235M518
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 11/12/1986
From: Munro J, Rogers T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20235M447 List:
References
50-395-OL-86-01, 50-395-OL-86-1, NUDOCS 8710060217
Download: ML20235M518 (4)


Text

- - _ .

I 9  :

ENCLOS_URE_1 oL I EXAMINATION REPORT 395/0L-86-&r Facility Licensee: South Carolina Electric and Gas Company  ;

ATTN: Mr. D. A. Nauman, Vice President l' Nuclear Operations P. O. Box 764 (167) .

Columbia, SC 29218 Facility Name: V. C. Summer Facility Docket No.: 50-395 j Written and operating examinations were administered at V. C. Summer near Jenkinsville, South Carolina.

Chief Examiner: __

T.

dogers

//12"80 Date Signed Approved by: # tyf- pr y N - / 2 - Fr 6 olohn' . Munro( >ct'on Chief Date Signed Summary:

Examinations on August 13, 1986 and September 12, 1986.

Oral and simulator examinations were administered to three candidates; two of whom passed. Four candidates were administered written examinations; three of four candidates passed.

Based on the results described above, the one R0 candidate did not pass and the two SRO (IC) candidates did pass. Oral and Simulator examinations will be administered to the remaining SRO (IC) candidate at a later date.

l 1

l K .

8710060217 861113 PDR ADOCK 05000395 PDR l

i

_ _ _ _ _ _ _ _ _ J

-t i 1

REPORT DETAILS

1. Facility Employees Contacted:
  • J. Heilman, Associate Manager, Nuclear Operations Education and Training
  • T. Matlosz, Nuclear Operations Training Supervisor
  • M; Williams,. Manager, Nuclear Operations Education and Training
  • Attended Exit Meeting
2. . Examiners:

C. Casto J.'Munro

  • T. Rogers J. Moorman

=J. Arildsen

  • Chief Examiner
3. Examination Review Meeting .

1 At the conclusion of the written examinations, the examiners provided T. L.

Matlosz with a copy of the written examination and answer key for review.

The comments made by the facility reviewers are included as Enclosure 3 to this report, and the NRC Resolutions to these comments are listed below.

a. SRO Examination . Analogous R0 questions are in parenthesis Question 5.01 b.3.

NRC Resolution:

Utility comments not accepted. Due to insufficient detail provided in the enclosure to support the facility comment, no change to the answer key is warranted. Training materials thould be updated to reflect this information.

Question 5.13 (1.14)

NRC Resolution:

Utility comment accepted, Additional answers from Technical Specification 3/4.1.3 bases are acceptable for full credit.

V. .C. Summer Reactor Theory publications should be modified to reflect this information.

m. .

'Y $

2 Question 6.05(2.08)

A post-examination review of this question cy the examiners determined that this question should be deleted since many of the sources of water to the BRS are not." systems".as stated in the question. The utilities training material, including Systems Descriptions AB-11, should be corrected to properly categorize these sources of water.

Question- 6.06 (2.09)

NRC Resolution:  ;

Utility comment' accepted. Question deleted due to equipment removal.

Training materials have 'not . incorporated these plant.. changes. Such-materials should be modified to reflect current plant design, Question 6.14 (2.16)

NRC Resolution:

Utility comment not accepted. The utilities system description of the service water system clearly describes the capability for independent loop operation. This requires that a " specific back-up source of emergency feedwater" be identified in such a manner as to be loop i specific.

Question 7.11 NRC Resolution:

Utility comment accepted. The answer is modified not to require parameter values.

Question 7.20 NRC Resolution:

Utility comment accepted. Either "for life saving operations" or "for ,

search and rescue for KNOWN missing persons" is acceptable.

Question 7.22 (4.22)

NRC Resolution:

Utility comment accepted. Due to the lack of question specificity, either the original answer or any one of the additional answers provided for SOP-114 is acceptable for full credit. The utilities systems description, IC-5, should be modified to reflect the explicit systematic requirements.

- - i

I s t 3

Question 7.23 b. (4.23)- .,

l NRC Resolution:

The utilities procedure GOP-3 clearly

~

I Uti1ity comment not accepted.

states the review requirement of within four hours of criticality.

This will be true despite any postulated delays which may further limit the time of review. (i .e. 'The completion of the ECC calculation being

.less than three hours prior to criticality, such as could be postulated due to a recalculation required by the cr'ticality no longer expected

'to occur within the two hours of ' the initial estimated time of criticality.) Therefore, the answer remains unchanged. However, full credit will be given for a specific answer stating the requirement to

" Recalculate or reverify" the ECC if criticality will not occur within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of the estimated time of criticality (REP-109.001).

b. R0 Examination Ouestion 3.09 NRC Resolution:

Utility ' comment accepted. The additional answer from the Westinghouse Tech Manual for solid state protection system is acceptable as one of the three answers required for full credit. The utilities training material, including Systems Description IC-9, should be modified to reflect this additional information.

4, Exit Meeting At the conclusion of the site visit, the examiners met with representatives of the plant ' staff to discuss the results of the examination.

There were no generic weaknesses noted during the oral examination.

The cooperation given to the examiners and the effort to ensure an atmosphere.in the control room conducive to oral examinations was also noted and appreciated.

The licensee did not identify as proprietary any of the material provided to or reviewed by the examiners.

I l

_ _ _ _ _ __ . _ . _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . _ _ . _ _ _ _ _ . _ _ _ _ . _ . _ _ _ _ _ l