ML20235M030

From kanterella
Jump to navigation Jump to search
Forwards EGG-EA-7640, South Texas Project-1 Sqrt Rept. Rept Consists of Review of Dynamic Qualification of safety-related Electrical & Mechanical Equipment,Including Audit of Selected Equipment Items
ML20235M030
Person / Time
Site: South Texas  STP Nuclear Operating Company icon.png
Issue date: 06/10/1987
From: Obenchain C
EG&G IDAHO, INC., IDAHO NATIONAL ENGINEERING & ENVIRONMENTAL LABORATORY
To: Carrington M
Office of Nuclear Reactor Regulation
Shared Package
ML20235M032 List:
References
CON-FIN-A-6415 OBEN-86-87, NUDOCS 8707170029
Download: ML20235M030 (2)


Text

1

/N#A isano nationai togineering iaboratory June 10, 1987 g

Mr. Mayo Carrington, Project Manager Technical Assistance Management Branch Planning & Program Analysis Staff Office of Nuclear Reactor Regulation Bethesda, MD 20814 REVIEW 0F DYNAMIC QUALIFICATION OF SAFETY RELATED ELECTRICAL AND MECHANICAL l

EQUIPMENT FOR SOUTH TEXAS PROJECT NUCLEAR GENERATING STATION, UNIT 1--SQRT i

REPORT (A6415) - Oben-86-87

(

Reference:

G. E. Marx ltr to S. B. Milam, Marx-56-84, Transmittal of j

NRC Form 189 for Equipment Qualification Case Reviews (A6415),

j February 10, 1984 j

Dear Mr. Carrington:

EG&G Idaho personnel assist the Mechanical Engineering Branch (MEB) of the NRC in the review of applicants' programs for qualification of safety j

related electrical and mechanical equipment for seismic and dynamic loads.

i The review consists of:

(1) a determination of the acceptability of the i

procedures used, standard followed, and completeness of the program in general, and (2) an audit of selected equipment items to develop the basis for the staff judgment on the completeness and adequacy of the implementation of the entire scismic and dynamic qualification program. This is done by a seismic qualification review team (SQRT).

The SQRT consists of engineers from MEB and the Idaho National Engineering Laboratory (INEL).

During the week of December 16 through December 19, 1986, EG&G Idaho personnel (J. N. Singh, R. G. Rahl and 8. L. Harris) assisted the NRC i

in the SQRT audit of a sample of selected equipment for the South Texas Project Nuclear Generating Station, Unit 1.

The audit, which was performed at the plant site, consisted of field inspection of equipment, review of the qualification reports, resolution of issues, and identification of action items encountered during the review.

I i

8707170029 070610 DR ADOCK 00000498 g'g 1 1

PDR gp hEGnB,s.no,sne, P.O. Box 162S Idaho Falls, ID 8341S geol

)

su

Mr. M. Carrington June 10, 1987 Oben-86-87 Page 2 I

The enclosed report contains results of the SQRT review.

This report is completed as a part of Subtask d, Project I of FIN No. A6415.

Very truly yours, C. F. Obenchain, Manager NRR and I&E Support j

l jr i

Enclosure:

As Stated cc:

S. Hou, NRC/MEB G. L. Jones, DOE-ID L. B. Marsh, NRC/MEB J. O. Zane, EG&G Idaho (w/o Enclosure)