September 28, 1987 MEMORANDUM FOR:
Ellis W. Merschoff, Chief Vendor Inspection Branch l
Division of Reactor Inspection and Safeguards THROUGH:
James C. Stone, Chief I
Program Development and Reactive Inspection Section i
Vendor Inspection Branch Division of Reactor Inspection and Safeguards
]
4 l
FROM:
Joseph J. Petrosino Program Development and Reactive Inspection Section Vendor Inspection Branch Division of Reactor Inspection and Safeguards l
SUBJECT:
MEETING MINUTES OF AN AUGUST 11, 1987 AMERACE CORPORATION /NRC MEETING Representatives from the Amerace Corporation of New Jersey were invited and gave the NRC Staff a presentation of the differences between its Agastat nuclear grade (E-Series) and commercial grade electrical relays. The meeting was 1:
conducted in the third floor conference room in the West Tower of East West i
Towers.
l l
The Amerace Corporation (TAC) started its presentation by giving a history of its l
electrical relay product development from its initial application of military,-
I space and comercial users to t1e present day models and users.
Following, TAC discussed the differences between its general purpose control and 7000 series relays and discussed the differences in design changes,'in-process testing, and the differences in its functional testing between nuclear and commercial grade relays.
1 TAC initially started its electrical pneumatic relay production in approximately
)
1950 with its 2400 series that was replaced in 1971 by its 7000 series l
commercial grade relay. The 7000 series is similar in appearance, form, fit, i
and function to the 2400 series except for the timing delay adjusting dial.
The time delay adjusting dial is larger on the 7000 than its 2400 series predecessor.
Nuclear-The 7000 series comercial grade relays replaced the 2400 series in 1971 and are still being produced. The nuclear grade E7000 series was not introduced until January 1980, and TAC states that out of the three different 93%37h70928 RRD
Ellis W. Merschoff September 28, 1987 electrical pneumatic devices, only the E7000 series is designed, manufactured, and tested in accordance with 10 CFR Part 21, Appendix B to 10 CFR Part 50, and ANSI N45.2. Additionally, only the E7000 series relay is tested and analyzed to meet the requirement of IEEE 323, 344, and ANSI C37.98.
Development of the E7000 series started in approximately 1975 with the establishment of different drawings, design control, traceability methods, and manufacturing and testing control practices.
In summary the nuclear E7000 series has imposed the following controls as a minimum:
1.
Final Functionability tests throughout the entire operating parameters; 2.
Design, manufacture and testing are performed only at TAC Union, New l
Jersey Facility; 3.
100% product in process inspections; 4.
Design change control; and 5.
10 year projected qualified life.
Commercial grade-The 7000 series Agastat relays are identical to the E7000 FrTes in physical appearance, form, fit and function.
Commercial grade 7000 relays may be manufactured at Amerace Facilities in Mexico, Beligum, Canada or Union, New Jersey. Some of the differences noted between the commercial and nuclear grade relays are as follows:
1.
No design change or configuration controls are required; l
2.
Functionability product testing is neither as comprehensive nor documented as the comparable E7000 tests,
~
i l
3.
Internal component substitutions are not documented or controlled; 4.
The commercial grade relays can be manufactured at any of the Agastat fabrication facilities, as noted above; 5.
No projected qualified life in excess of 2 years is made by the Amerace Corporation; and 1
6.
Undocumented field modification of the relays is allowed by the distributors as they deem necessary.
Control Relays-Both Agastat commercial and nuclear grade general purpose and timing control relays are manufactured at Grafton, Wisconsin.
The previously discussed control methods are also applicable to TAC control relays.
l l
___________.______________m__
Ellis W. Merschoff September 28, 1987 Neeting' Attendees:
Joseph Ferguson,. Director, Quality Assurance, Amerace Corporation "
Ed teszczak, Product Engineer,-Amerace Corporation Jack Ramsey, Nuclear Engineer, NRR/DOEA/0GCB Joseph Petrosino, VIB,'NRR/VIB
- Thomas Cheug, Station Engineer, OSP/TVA/EB Robert Pierson, Branch Chief, OSP/TVA/PSB George Hubbard, Plant System Engineer, DSP/TVA/PSB Jim Stone, VIB, NRR/VIB Ed Baker, VIB Rector Engineer, NRR/VIB Ellis Herschoff, VIB Chief, NRR/VIB
/
w Jo eph J. Petrosino Program Development and Reactive Inspection Section Vendor Inspection Branch Division of Reactor Inspection and Safeguards i
d u n i
l
G Ellis W. lierschoff september 28, 1987 lieeting Attendees:
Joseph Ferguson, Director, Quality Assurance, Amerace Corporation Ed Leszczak, Product Engineer, Amerace Corporation Jack Ramsey, Nuclear Engineer, llRR/DOEA/0GCB Joseph Petrosino, VIB, NRR/VIB Thomas Cheug, Station Engineer, OSP/TVA/EB Robert Pierson, Branch Chief, OSP/TVA/PSB George Hubbard, Plant System Engineer, DSP/TVA/PSB Jim Stone, VIB, NRR/VIB Ed Baker, VIB Rector Engineer, NRR/VIB Ellis Merschoff, VIB Chief, NRR/VIB f
Joseph J. Petrosino Program Development and Reactive Inspection Section Vendor Inspection Branch Division of Reactor Inspection and Safeguards
. DISTRIBUTION
@fD5CodeIE:09s\\
VIB Reading DRIS Reading BGrimes JPartlow j
JStone JPetrosino 0FC
- VIB;DRIS
- 5C/VIB:DRIS
.....:....q.____._
NAME:JPh..rosino:jh:J fL DATE O M//87.......... : 9, 1
/8
._a
- 1 l
Ellis W. Merschoff
-3 September 28, 1987 j
L, l
I Meeting Attendees:
j Joseph Ferguson, Director, Quality Assurance, Amerace Corporation -
Ed Leszczak, Product Engineer, Amerson Corporation L
Jack Ramsey, Nuclear Engineer, HRR/DOEA/0GCB l
Joseph Petrosino, VIB, NRR/VIB Thomas Cheug, Station Engineer, OSP/TVA/EB Robert Pierson,. Branch Chief, OSP/TVA/PSB George Hubbard, Plant System Engineer, DSP/TVA/PSB Jim Stone, VIB, NRR/VIB Ed Baker, VIB Rector Engineer, NRR/VIB I
Ellis Merschoff, VIB Chief, NRR/VIB I
f Joseph J. Petrosino Program Development and Reactive Inspection Section Vendor Inspection Branch Division of Reactor Inspection and Safeguards
/
DISTRIBUTION RIDS Code IE:09 VIB Reading DRIS Reading BGrimes
~~
JPartlow J5 tone JPetrosino 0FC :VIB;DRIS
- 5C/VIB:DRIS :
l l NAME :
osino:jh :J e
- .....
- )..___........:k..,,' 8 l DATE :
/c9//87
. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -