Applicant Exhibit A-29,consisting of 870424 Analysis of Traffic Vol & Evacuation Data from 10:00 Am - 1:00 Pm at Intersection of Old Country Road & Broadway Route 107
ML20235E513
Person / Time
Site: Shoreham File:Long Island Lighting Company icon.png
Issue date: 07/23/1987
From:
AFFILIATION NOT ASSIGNED
To:
References
OL-3-A-029, OL-3-A-29, NUDOCS 8709280144
Download: ML20235E513 (9)


Text

?

e

~

,T fp ' 3 Q.

g9[]

~y l

b.,

y g gg

_C_/LCO_.

p

- r. -

4,..

t.-

o?5 HCM: SIGNALIZED. INTERSECTIONS D O, C,yHETED

' Pa m e-

.+++++++++e++.++++++++++ +++++**+++++**++++++++<*+d+m.*+.+++n++++

+

'g7 ggp IDENTIFYING INFORMAT*ON.= = = = = = = = = = = = = = = = = = = = = = = = = = = =

NAME OF THE EAST / WEST STREET.........OLD.COUNTRV' ROAD

, u;v NAME OF THE NOU H/ SOUTH STREET.......ERDADWAY RT/107' AREA. TYPE.............................OTHER PEDESTRIAN WAiKING SPEED.............

C (feet /sec)

NAME OF THE ANALYST..................BG DATE OF THE ANALYSIS.................4/04/S7

'/cee.-):100 TIME PERIOD. ANALYZED..'...............C~'

l' OTHER INFORMATION:

FiIe 206?

20% Evacuation t

TRAFFIC VOLUMES

======_============================e=====

=============,

EB WB NB SB LEFT 117 157 126 480 THRU 656 746 577 440 RIGHT 20'i.

1*4 421 121 RTOR 80 40 80 40 (RTOR vo l ume raus t be less than or ecual to RiGHT turn volumes.)

4 b.

t

+

~... -. -...

n.,

a. -..::.

g3 p

O PhE' l

t e

V' da i

'h i

(:

\\'

1 s

4.,\\v

\\.

\\

s

\\

[

M ~

s I

NN h

' l "g \\A t

b g

\\

d, \\ ),.\\

%eg i

p3: ip s

i

- i

g-t Pas INTERSECTION GEOMETRY

==

===u========================================

NUMBER OF LANES FER DIRECTION INCLUDING TURN BAYS:

EASTBOUND = 4 WESTBOUND = 4 NORTHBOUND =

4-SOUTHBOUND = 4 EB WB NB SB l

LANE TYPE WIDTH TYPE WIDTH TYPE WIDTH TYPE WIDTH 1

L

  • O.0 L

10.0 L

10.0 L

10.0 2

T 12.0 T

12.0 7

12.0 T

12.0 3

T 12.0 T

12.0 T

12.0 T

12.0 4

R 12.0 R

12.0 R

12.0

.R 12.0 5

12.0 12.0 12.0 12.0 6-

  • 2.0 12.0 12.0 12.0 T

- EXCLUSIVE THROUGH LANE EXCLUSIVE LEF LANE L

TR - THROUGH/RIGHT LANE LEF7/THROUGH LANE LT LIFT /RIGHT ONLY LANE R

- EXCLUSIVE RIGHT LANE

'R LTR - _ EFT /THROUGH/RIGHT LANE ADJLSi*ENT FACTORS

_=n=========================================..===_========

GRADE HEAVY VE-!. ADJACENT PKG BUSEE

(%?

(*:)

Y/N (Nrn)

(Nb)

PHF EASTBOUND O.00 2.00 N

O O

O.91 WESTBOUND O.00 2.00 N

O O

O.99 NORTHBOUND O.00 2.00 N

O O

O.99 SOUTHBOUND O.00 2.00 N

O O

O.99 Nrn = n urnb e r of parking maneuvers /br:

Nb = n utn b e r of buses stoppir CONFLICTING PEDS PEDESTRIAN BUTTON (oeds/bour)

(Y/N)

(min T)

ARRIVAL i

EASTBOUND 50 N

30.8 3

WESTBOUND 50 N

30.8 3

NORTHBOUND 50 N

30.S 3.

SOUTHBOUND 50 N

30.8 3

?

min T= m i n i rnum green time for pedestrians l

i

a n

6 SIGNAL SETTINGS - DESIGN ANALYSIS Pt

=========================================================.========4 ACTUATED LOST TIME / CYCLE

8.0 CYCL E ' LENGTH = 100.0 EAST / WEST PHASING PHASE-1 PHASE-2 PHASE-3 PHASE-4 EASTBOUND LEFT X

X THRU X

RIGHT X

PEDS X

WESTDOUND LEFT X

X THRU X

l RIGHT X

PEDS X

i l

NORTHBOUND RT SOUTHBOUND RT i

NORTH / SOUTH PHASING PHASE-1 PHASE-2 PHASE-3 PHASE-4 NCRTHBOUND i e_ r _i s,,

un s

m THRU X

RIGHT X,

PEDS X

SOUTHBOUND LEFT X

X X

THRU X

X RIGHT X

X PEDS.

X X

EASTBOUND RT X

WESTBOUND RT X

l

?

e l

l I.

I

_ _ - _. - ~ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6 EFFECTIVE GREENS - DESIGN ANALYSIS Page-

=======================================================.

EFFECTIVE GREEN, g EASTBOUND LEFT Pe rrn i t t e d 41.00 Protected 12.00 THRU 41.00 RIGHT P e r rn i t t e d 41.00 Protected

12. 00 l

WESTEGUND LEFT l

P e r rn i t t e d 41.00 Protected 12.00 THRU 41.00 RIGHT P e r rn i t t e d 41.00 Pretected 2.0.00 l

l NORTHEOUND l

LEFT Pe rrn i t t e d 47.00 Protetted 12.00 l

THRU 39.00 RIGHT P e rrn i t t e d 39.00 P otected 0.00 SOUTH 3OUNO

, -_=

c-Pe r rn i t t e d 3o.OO Protected 20.00 THRU i

4T.00 RIGHTi P e r rn'i t t e d 47.00 Protected 0.00 k

~

i i

q s

VOLUME ADJUSTMENT WCRE: SHEET Pa

==================================================================ge-

==,

i LANE LANE ADJ.

MVT.

ADJ.

LANE GRP.'NG. UTIL.

GROWTH GRP.

PROP FRO!

VOL, PHF VOL.

GRP.

.VOL. LN FACT.

FACT.

VOL.

LT RT EB l

LT 117- 0.91 144 L

144 1

1.000 1.000 144 1.00 0.0 j TH d56 0.81 810 T

810 2

1.050 1.000 850 0.00

0. 0 l RT 20e 0.81 155 A.

155 1

_1.000 1.000 155 0.00 1.0 l

~

WB LT 157 0.99 159 L'

159 1

1.000 1.000 159 1.00

0. O' TH 746 0.99 754 T

754 2

1.050 1.000 701 0.00

0. O' )

RT 194 0.99

.56 R

156 1

1.000 1.000 156 0. 0,0 1.01 NB LT 22 d.

0.99 228 L

228 1

1.000 1.000 228 1.00' O. O( !

TH 577 O.99 583 T

583 0

1.050 1.000 612 O.00 O. O'. l RT 421 0.99 744 R

744 1

1.000 1.000 844 0.00

1. O'. i SB l

LT 480 0.co 4 ':5 L

485 1

1.000 1.000 485 1.00 0.01:

1 7H 449 O.99 454 T

454 2

1.050 1.000 476 0.00 O. OC RT 121 0.09 D2 R

82 1

1.000 1.000 82 0.00

1. OC '

1

+ Denotes a Defacto Left Turn Lane Grouo i

l l

l l

1 l

L_____________._

1 1

i I

l 6

1 SATURATION FLOW ADJUSTMENT WORK 5HEET Paec :

samanzzassenssammarammze=======smze==============sumer=======merem

' 1 s

IDEAL ADJ(

SAT.

NO.

f.

f f

f f

f f

f SA7l FLOW-LNS W

HV G

p BB A

RT LT FLC.;

EB L

1800 1

0.930 0.990 1.000 1 000 1.000 1.000 1.000 0.950 157!

T 1800 2

1.000 0.990 1.000 1.000 1.000 1.000 1.000 1.000 25eI I

R 1800 1

1.000 0.090 1.000 1.000 1.000 1.000 0.838 1.000 149 WB L

1800 1

0. o30 0. 9 ~eO 1. 000 1.000 1. 000 1.000 1. 000 0. 950 15-T 1800 2

1.000 0.900 1.000 1.000 1.000 1.000 1.000 1.000 35e{

j R

1800 1

1.000 0.990 1.000 1.000 1.000 1.000 0.838 1.000 14cj 1

NB L

1800 1

0.9?O O.990 1.000 1.000 1.000 1.000 1.000 0.950 157 T

1800 2

1.000 0.990 1.000 1.000 1.000 1.000 1.000 1.000 ?56 R

1800 1

1.000 0.990 1.000 1.000 1.000 1.000 0.826, 1.000 14~!

l 5B l

L 1800 1

0.C30 0.990 1.000 1.000 1.000 1.000 1.000 0.950 157-l1 T

1800 2

1.000 0.990 1.000 1.000 1.000 1.000 1.000 1.000 25cM R

1800 1

1. 000 0. 990 1. 000 1. 000 1. 000 1. 000 0. 82d. 1. 000 147 1

1

\\

a l

t 1

l I

i

.[

i i

i

6*

~

TAPACITY ANA YSIS WORKSHEET Page-

se============================================================

ADJ.

ADJ. SAT.

FLOW LANE GROUP FLOW RATE FLOW RATE-RATIO GREEN RATIO CAPACITY v/c' (v)

(s)

(v/s)'

(9/C)

(c)

RATIO EB L ei e r rn.

84 L:, rot.

d.O 1574 0.038 0.100 157 0.382 T

850 35c4 0.239 0.342 1218 0. d.98 l

R 155 1493 0.104 0.442 ddO O.235 WB l

Lterm.

E:9 L tir o t.

TO 3574 0.044 0.100 157 0.442 T

791 35c.4 0. 2".2 0.342 1218

0. d.50 R

156 1493 0.104 0.508 759 0.2v5 NB L: e r rn.

160 L:irot.

e.8 1574 0.04?

O.100 157 0.4?2 e.12 35e4 0.172 0.?25 1158 0.528 i

R 344 1472 0.2?4 0. 3".5 478 C

'1 1 9 SE Ltierm.

244 Lprot.

241 1574 0.153 0.167 262 0 918 I 4

T 47 e.

2564 O.134 0.392 1396 O.341 R

92 1472 0.056-0.392 577 0,243

0. c.0 0 Cycie Leng;h.

C=

120.0 sec.

Sum (v/s) eritical

=

8.0 sec.

X critical = 0.651 Lest ime et C y c l e -, L

~

=

l n

I l

.e

1 i

6 LEVEL-OF-SERVICE WORK 5HEET

==========================r======================================Pa,:

==

DELAY' LANE DELAY LANE LANE DELAY LOL v/c 3C CYCLE d

GROUP d

PROG. GRP.

GRP. EY EV

/

RATIO RATIO LEN.

1 CAP.

2 FACT. DELAY LOS APP.

AP.

_______________.________________________.______j EB 1

L O.382 0.442 120.0 17.1 157 0.8 1.00 17.0 C

21.1 C

T O.693 0.342 12").O 26.0 1218 1.3 0.85 23.1 C

R O.235 0.442 1'.0.0 15.O d.d.O O.0 O.E5 13.5 B

ais i

L O.442 0.442 120.0 17.7 157 1.3 1.00 19.0 C

20.2

'C T

O.d.50 0.342 120.0

'. 5. 4 1218 0.*

O.85 22.3 C

3 R

O.205 0.508 120.0 12.3 759 0.0 0.95 10.5 B

i JB L

O.432 0.492 1'.O.0 15.0 157 1.2 1.00 16.2 C

11.9 C

T O.529 0.325 120.0 25.1 1158 0.4 0.95 21.6 C

R O.719 0.325 120.0 27.1 473 3.6 O.25 16.1 D

SE L

O.918 0.4?2 120.0 21.5 262 24.6 1.00 4d. 1 E

30.2 D

T O.341 0.392 120.0 19.5 I?96 0.1 0.85 16.6 C

R O.143 O.192 120.0 17.9 Si'7 0.0 0.85 15.2 C

Ir. ersection Deity =

23.2 (sec/ven)

Intersection LOS = C 1

)

I

..O i

--