ML20235D763

From kanterella
Jump to navigation Jump to search
Responds to Concerns Noted in Insp Rept 50-309/86-17. Corrective Actions:Security Contingency Plan Revised & Operations Dept Directive Operations in Response to Events Concerning..., Rewritten & Expanded,Per Listed Items
ML20235D763
Person / Time
Site: Maine Yankee
Issue date: 09/21/1987
From: Whittier G
Maine Yankee
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
GDW-87-222, MN-87-103, NUDOCS 8709250337
Download: ML20235D763 (2)


Text

_

m MaineYankee RELIABLE ELECTRICITY FOR MAINE SINCE 1972 EDISON DRIVE. AUGUSTA, MAINE 04330.(207) 622 4868

~

a September 21, 1987 q

MN-87-103 GDH-87-222

!$ m m

g$b E

United States Nuclear Regulatory Commission Attention:

Document Control Desk Hashington, D. C.

20555

References:

(a)

License No. DPR-36 (Docket No. 50-309)

(b) USNRC Letter to MYAPCo dated August 12, 1987 - Inspection Report 86-17 (Safeguards Information)

J l

Subject:

Response to Inspection Report No. 50-309/86-17

{

Gentlemen:

i 1

This letter outlines the actions taken and proposed by Maine Yankee to address NRC concerns about the guidance which has been provided to plant staff regarding the matters enumerated in Paragraph 2.C of subject inspection report.

The security procedures used to implement the security contingency plan l

have been revised to adequately address the responsibilities and actions of i

the security contingency plan.

Each of the eight contingencies have been addressed in matrices which list the actions of all individuals, including the Plant Shift Superintendent.

l An Operations Department directive entitled " Operations in Response to Events Concerning Deliberate Acts Directed Against Plant Equipment" has been rewritten and expanded to provide the following:

a.

Guidance to the Plant Shift Superintendents to ensure consistent responses to the contingencies addressed in the implementing security procedures.

b.

Better definition of Operations Department responsibilities and actions.

c.

Guidance to Plant Shift Superintendents to help them decide when it would be prudent to shut down the plant.

G709250337 870921'T PDR ADOCK 05000309 G

FDR l

ysot' 9120L-ECS 0

a

n MaineYankee United States' Nuclear: Regulatory Commission.

Page Two Attention: Document ~ Control Desk MN-87-103-Training was provided t'o the Plant Shif't Superintendents and'the Shift Operating. Supervisors on the revis'ed security procedures and the Operations Department directive discussed above.

1.

Training.concerning sabotage, external attack-type threats and anti-sabotage precautions will be. incorporated into the licensed operator. requalification program by December 31,.1987..

He have determined that this letter does not contain Safeguards Information 'needing protection from public disclosure as defined in 10 CFR 73.21.

He trust this information addresses the concerns expressed in Reference (b). Pleast contact me if you have any questions on the enciesed information.

Very truly yours, MAINE-YANKEE h./N hv-G. D. Whittier, Manager Nuclear Engineering and Licensing GDH/bjp Enclosure-cc: Mr. Victor Nerses Mr. Hilliam T. Russell Mr. Pat Sears Mr. Cornelius F. Holden

)

I l

1 i

9120L-ECS; l

1

>