Docket Nos.: 50-327/328 September 15,:1987 LICENSEE:-

Tennessee Valley Authority.

. FACILITIES:

Sequoyah Nuclear Plant, Units 1 and 2 1

SUBJECT:

MINUTES OF THE SEPTEMBER 11, 1987 MEETING WITH THE TENNESSEE VALLEY AUTHORITY-i q

On September 11, 1987 Mr. J. G.~ Keppler and members of the Office of Special 1

Projects, NRC. staff met with Mr. S. A. White and representatives of the Tennessee Valley Authority (TVA). The purpose of the meeting was-for the NRC staff to present.to TVA the findings from the integrated design inspection conducted by the staff on the Sequoyah Nuclear Plant. is a list of attendees. The. meeting transcription is provided as Enclosure 2.

If you should. have any questions regarding the information provided, please l

contact me at (301) 492-4835.

J i

Original Signed By Janet L. Kelly, Project Engineer l

l Sequoyah Restart Branch-i TVA Projects Division-Office of Special Projects 4

Enclosures 1

1.

Attendee List

)

2.

Transcript

-j cc: See next page s

l l

8709240001 070915 PDR ADOCK 05000327 G

PDR T

TVA:AD/P J

11y:pw JZwolinski 4/16/87 3 /i /87 6

i j#' ""'4 UNITED STATES c  % 35 *t NUCLEAR REGULATORY COMMISSION 7

E,,

\\..[.7 j WASHINGTON, D. C. 20555 W

/

+

September 15, 1987 Docket Nos.: 50-327/328 LICENSEE:

Tennessee Valley Authority FACILITIES:

Sequoyah Nuclear Plant, Units 1 and 2

SUBJECT:

MINUTES OF THE SEPTEMBER 11, 1987 MEETING WITH THE TENNLSSEE l

VALLEY AUTHORITY On September 11, 1987, Mr. J. G. Keppler and members of the Office of Sr.ecial Projects, NRC, staff met with Mr. S. A. White and representatives of the Tennessee Valley Authority (TVA). The purpose of the meeting was for the NRC staff to present to TVA the findings from the integrated design inspection conducted by the staff on the Sequoyah Nuclear Plant. is a list of attendees. The meeting transcription is provided as Enclosure 2.

If you should have any questions regarding the information provided, please contact me at (301) 492-4835.

A L \\GLg Janet L. Kelly, Project Engineer Sequoyah Restart Branch TVA Projects Division Office of Special Projects Enclosures i

1.

Attendee List 2.

Transcript l

cc: See next page 1

L___._.______--

]

J k

i 1

Mr. S. A. White i

Tennessee Valley Authority Sequoyah Nuclear Plant i

cc:

General Counsel Regional Administrator, Region II d

Tennessee Valley Authority U.S. Nuclear Regulatory Comission

]

400 West Sumit Hill Drive 101 Marietta Street, N.W.

E11 B33 Atlanta, Georgia 30323 Knoxville, Tennessee 37902 q

Resident Inspector /Sequoyah NP j

Mr. R. L. Gridley c/o U.S. Nuclear Regulatory Comission Tennessee Valley Authority 2600 Igou Ferry Road SN 157B Lookout Place Soddy Daisy, Tennessee 37379 Chattanooga, Tennessee 37402-2801 Mr. Richard King j

Mr. H. L. Abercrombie c/o U.S. GA0 i

Tennessee Valley Authority 1111 North Shore Drive j

Sequoyah Nuclear Plant Suite 225, Box 194 P.O. Box 2000 Knov.ville, Tennessee 37919 l

Soddy Daisy, Tennessee 37379 Tennessee Department of Mr. M. R. Harding Public Health Tennessee Valley Authority ATTN: Director, Bureau of Sequoyah Nuclear Plant Environmental Health Services j

P.O. Box 2000 Cordell Hull Building Soddy Daisy, Tennessee 37379 Nashville, Tennessee 37219 4

Mr. D, L. Williams Mr. Michael H. Mobley, Director Tennessee Valley Authority Division of Radiological Health 400 West Sumit Hill Drive T.E.R.R.A. Building W10 B85 150 9th Avenue North Knoxville, Tennessee 37902 Nashville, Tennessee 37203 County Judge Hamilton County Courthouse Chattanooga, Tennessee 37402 l

ENCLOSURE 1 TVA/NRC MEETING - IDI EXIT September 11, 1987 Name Organization Telephone Herbert Abercrombie Seqyoyah Nuclear Plant 615-870-7001 R. Gridley TVA Licensing 615-751-2729 C. C. Mason TVA ONP 615-751-2742 1

S. A. White TVA ONP 615-751-4770 C. H. Fox TVA ONP 615-751-4776-M. J. Ray TVA Licensing 615-751-8379 Douglas W. Wilson TVA-Chief. NEB 615-632-3063 R. H.-McFadden NRC(Consultant) 212-679-3244 H. B. Wang NRR/DRIS/RSIB 301-492-9676 R. E. Shewmaker NRC 301-492-4288 E. V. Imbro NRC 301-492-9664 R. W. Parkhill NRC/DRIS/ SIB 3M -492-4942 A. V. Dubouchet NRC/ CONS / MECH COMP 2G'.-390-8280 j

J. M. Leivo NRC Consultant 301-831-3003 B. K. Grimes NRC/DRIS 301-492-8836 l

John A. Zwolinski NRC/OSP/TVA Projects 301-492-9696 Stewart Ebneter NRC/OSP/TVA 301-492-9663 Jim Keppler NRC/0SP 301-492-7397 Jane Axelrad NRC/OSP 301-492-8177 B. D. Liaw NRC/OSP/TVA Tech. Program 301-492-9677 Gary Zech NRC/0SP/TVA Insp. Program l

L. M. Nobles TVA/ SON 615-870-6501 l

J. T. LaPoint TVA/SQN 615-870-7725 Karl S. Seidle TVA/DNE 615-632-3745 Sherry Johnson TVA/ Manager's Office 615-751-4770 B. Charlson TVA/0NP 615-751-4773 R. E. Daniels TVA/DNE 615-872-5485 Robert C. Williams TVA/DNE 615-874-5150 Kenneth L. Mogg TVA/DNE 870-4163 Charles N. Johnson TVA/DNE 874-5207 J. J. Wilder TVA/DNE 632-2043 D. E. McCloud TVA/DNSL 751-4876 M. T. Tormey TVA/DNE 632-0648 Walter E. Andrews TVA/DNQA 751-7818 Nicholas C. Kazanas TVA/DN0A 751-4929 Anothony P. Capozzi TVA/DNE 632-2247 Mike R. Harding TVA/SQN/DNSL 870-6422 T. A. 5ppolito TVA Licensin9 301-492-5718 Carol Ayers TVA/0NP 751-7804 Gerald Charnoff Shaw Pittman 202-663-8032 Deborah Bauser Shaw Pittman 202-663-8215 R. H. Buchholz TVA/0NP 870-7236 Charles A. Chandley TVA/DNE/MEB 615-632-2744 W.S. Raughley TVA/DNE/EEB 615-632-2441

Name Organization Telephone Don L. Williams TVA/DNSL/ Engineering Lic.

.615-632-7170 Bill Pennell TVA/DNE 616-632-3843 R. R. Hoesly TVA/DNE/BLEP 615-632-2316 J. C. Key TVA/DNE/SQEP 615-632-8764 A. I. Unsal NRC/HEA 201-767-4202 Owen Mallon NRC-Consultant 212-216-6375 Robert Masterson NRC-Consultant 401-732-5660 Victor Ferrarini NRC IDI Team 401-732-5660 Janet Kelly NRC/OSP/TVA Projects 301-492-4835 Barry Zaleman NRC/OSP 301-492-9042 Frank McCoy NRC/OSP 404-331-5525 S. T. Chen NRC/IDI 212-216-6237 James R. Houghton NRC/IDI Team 412-563-0536 John T. Haller NRC/IDI Team 412-561-1813 Joe Rutberg NRC/0GC 301-492-7488 Hukam Garg NRC/OSP 301-492-8736 i

Angelo Marinos NRC/OSP 301-492-9041 Glenn Walton NRC/0SP/ Watts Bar 8676 Edward Goodwin NRC/OSP 301-492-8892 Mel Fields NRC/OSP 301-492-8845 Jim Clifford NRC/0SP 301-492-9663 Frank Carr TVA/DNE/MEB 615-632-6378 Michael Gardenhire TVA/DNE/MEB 615-874-5499 Laura Simmons Knoxville News-Sentinel 615-521-1844 Kristi Umbreit AP 615-522-3963 Margaret Lillard UPI 525-3162

i. G. Chapman TVA 205-232-5836 D. A. Kulisek TVA-WBNP 615-365-3622 G. Bushnell SWEC 612-589-7168 D. T. Clift TVA 632-2342 J. E. Butt Combustion Engineering 615-752-2259 D. B. Crocker Westinghouse 615-752-4106
1. R. Williamson Westinghouse 615-752-4107 Pete Judd NUS Corp 301-258-6000 G. H. Rogers TVA ONP 615-751-5538 R. W. Cantrell TVA DNE 615-632-2651 P. R. Maudaura TVA DNE 615-632-2741 A. W. Chan SWEC 609-482-3354 K. S. Jadeja SWEC 609-482-3022 M. S. Martin TVA CSS 615-632-4241 D. H. Level TVA-DNSL 615-632-7160
1. L. Beltz TVA-DNE 615-632-2357 J. P. Willard Knoxville Journal Mike Nelson /Brud Gann WTVK-TV Knoxville 615-687-8522 Libby Wann Chattanooga Times 615-756-1234

s ca - zn /

1 l

DIST1RUBTION FOR MEETING

SUMMARY

DATED: September 15, 1987 Facility: Sequoyah Nuclear Plant, Units 1 and 2*

w/ enclosures w/o enclosures

-DocketcFile-EMcKenna J

NRC PDR MFields Local PDR Projects Rdg.

l JKeppler/JAxelrad SQN File j

SEbneter HGarg SRichardson AMarinos JZwolinski EGoodwin i

BDLiaw CJamerson JKelly FMiraglia BZalcman JPartlow OGC-Bethesda EJordan EVImbre JDonohew REShewmaker BGrimes 1

GZech FMcCoy l

JC11f ford ACRS(10)

Hon. M. Lloyd**

l Hon. J. Cooper **

Hon. A. Gore **

Hon. D. Sundquist**

Dr. Henry Myers**

-1 Mr. R. King, GA0**

)

CMiller H-1149 JHeltemes, Jr.

H-1149 CAder H-1149 JMilhoan H-1149 PGwynn H-1149 FCombs H-1159 TRehm TVA-Bethesda l

  • Copies sent to person on facility service list
    • Advance copy of transcript sent under separate cover 1

l 1

l